DICOM PS3.16 2026d - Content Mapping Resource

CID 12304 Cardiovascular Measured Property

The Units column contains the proper UCUM representation of the recommended units for the measured property

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

CardiovascularMeasuredProperty

FHIR Keyword:

dicom-cid-12304-CardiovascularMeasuredProperty

Type:

Extensible

Version:

20240920

UID:

1.2.840.10008.6.1.1145

Table CID 12304. Cardiovascular Measured Property

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

Units

LN

20168-1

Acceleration Time

C0802983

(ms, UCUM, "ms")

LN

59130-5

Alias Velocity

C2923486

(m/s, UCUM, "m/s")

SCT

1483009

Angle

G-A160

C0205143

(deg, UCUM, "deg")

SCT

42798000

Area

G-A166

C0205146

(cm2, UCUM, "cm2")

SCT

75367002

Blood Pressure

F-31000

C0005823

(mm[Hg], UCUM, "mmHg")

SCT

70822001

Cardiac Ejection Fraction

F-32070

C0232174

(%, UCUM, "%")

SCT

82799009

Cardiac Output

F-32100

C0007165

LN

20217-6

Deceleration Time

C0803032

(ms, UCUM, "ms")

SCT

81827009

Diameter

M-02550

C1301886

(cm, UCUM, "cm")

LN

59120-6

dP/dt by US

C2923468

(mm[Hg]/s, UCUM, "mmHg/s")

DCM

125325

Dyssynchrony Index

(ms, UCUM, "ms")

DCM

125326

Effective Orifice Area

(cm2, UCUM, "cm2")

LN

59093-5

Epicardial Area

C2923421

(cm2, UCUM, "cm2")

DCM

125327

Excursion Distance

(cm, UCUM, "cm")

LN

59132-1

Fractional Shortening

C2923490

(%, UCUM, "%")

LN

59090-1

Internal Dimension

C2923417

(cm, UCUM, "cm")

SCT

385673002

Interval

G-D217

C1272706

(ms, UCUM, "ms")

SCT

410668003

Length

G-D7FE

C1444754

(cm, UCUM, "cm")

SCT

118538004

Mass

G-D701

C1306372

(g, UCUM, "g")

DCM

125328

Maximum Orifice Area

(cm2, UCUM, "cm2")

SCT

6797001

Mean Blood Pressure

F-31150

C0428886

(mm[Hg], UCUM, "mmHg")

LN

20352-1

Mean Blood Velocity

C0803167

(m/s, UCUM, "m/s")

LN

20256-4

Mean Gradient [Pressure] by Doppler

C0803071

(mm[Hg], UCUM, "mmHg")

SCT

131188004

Minor Axis

G-A194

C1295724

(cm, UCUM, "cm")

LN

59099-2

Myocardial Performance Index (Tei)

C2923433

(1, UCUM, "no units")

DCM

125329

Peak Blood Pressure

(mm[Hg], UCUM, "mmHg")

LN

20355-4

Peak Blood Velocity

C0803170

(m/s, UCUM, "m/s")

LN

20247-3

Peak Gradient [Pressure]

C0803062

(mm[Hg], UCUM, "mmHg")

LN

34141-2

Peak Instantaneous Flow Rate

C1316604

(ml/s, UCUM, "ml/s")

DCM

125330

Peak Tissue Velocity

(cm/s, UCUM, "cm/s")

DCM

131013

Peak Velocity Index

DCM

125331

PISA Radius

(cm, UCUM, "cm")

LN

20280-4

Pressure Half Time

C0803095

(ms, UCUM, "ms")

LN

12008-9

Pulsatility Index

C0552113

SCT

399301000

Regurgitant Fraction

G-0390

C1302309

(%, UCUM, "%")

DCM

125332

Regurgitation Jet Area

(cm2, UCUM, "cm2")

DCM

125333

Regurgitation Jet Width

(cm, UCUM, "cm")

LN

12023-8

Resistivity Index

C0552128

SCT

90096001

Stroke Volume

F-32120

C0038455

(ml, UCUM, "ml")

LN

59089-3

Thickness

C2923416

(cm, UCUM, "cm")

SCT

251271006

Vascular Resistance

F-02692

C0429119

(dyn.s/cm5, UCUM, "dyn.s/cm5")

LN

20354-7

Velocity Time Integral

C0803169

(cm, UCUM, "cm")

DCM

125334

Vena Contracta Width

(cm, UCUM, "cm")

SCT

118565006

Volume

G-D705

C0449468

(ml, UCUM, "ml")

LN

33878-0

Volume Flow Rate

C1316341

(ml/s, UCUM, "ml/s")

Include CID 12311 “Echo Measured Strain Property”


DICOM PS3.16 2026d - Content Mapping Resource