DICOM PS3.16 2026a - Content Mapping Resource

CID 12015 Fetal Growth Equation/Table

These terms specify biometric growth parameter of a population distribution as a function of gestational age. The term may also specify the population's distribution, and so enable calculating a percentile rank or Z-score relative to the distribution.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Keyword:

FetalGrowthEquationTable

FHIR Keyword:

dicom-cid-12015-FetalGrowthEquationTable

Type:

Extensible

Version:

20210120

UID:

1.2.840.10008.6.1.563

Table CID 12015. Fetal Growth Equation/Table

Coding Scheme Designator

Code Value

Code Meaning

UMLS Concept Unique ID

LN

33145-4

AC by GA, ASUM 2000

C1315616

LN

33146-2

AC by GA, Hadlock 1984

C1315617

LN

33147-0

AC (measured) by GA, Chitty 1994

C1315618

LN

33546-3

AC (derived) by GA, Chitty 1994

C1316015

LN

33148-8

AC by GA, Merz 1988

C1315619

LN

33149-6

AC by GA, Shinozuka 1996

C1315620

LN

33150-4

AxT by GA, Shinozuka 1996

C1315621

LN

33151-2

BPD by GA, ASUM 2000

C1315622

LN

33198-3

BPD by GA, Hadlock 1984

C1315669

LN

33556-2

BPD outer-inner by GA, Chitty 1994

C1316025

LN

33152-0

BPD outer-outer by GA, Chitty 1994

C1315623

LN

33153-8

BPD by GA, Jeanty 1982

C1315624

LN

33154-6

BPD by GA, Merz 1988

C1315625

LN

33155-3

BPD by GA, Rempen 1991

C1315626

LN

33156-1

BPD by GA, Shinozuka 1996

C1315627

LN

33157-9

Cephalic Index by GA, Chitty 1994

C1315628

LN

33158-7

Cephalic Index by GA, Hadlock 1981

C1315629

LN

33159-5

CRL by GA ASUM 2000

C1315630

LN

33160-3

CRL by GA, Rempen1991

C1315631

LN

33161-1

CRL by GA, Shinozuka 1996

C1315632

LN

33162-9

EFW by GA, Hadlock 1991

C1315633

LN

33163-7

EFW by GA, Hansmann 1986

C1315634

LN

33164-5

Fibula by GA, Jeanty 1983

C1315635

LN

33165-2

FL by GA, ASUM 2000

C1315636

LN

33166-0

FL by GA, Hadlock 1984

C1315637

LN

33167-8

FL by GA, Chitty 1994

C1315638

LN

33168-6

FL by GA, Jeanty 1982

C1315639

LN

33169-4

FL by GA, Merz 1988

C1315640

LN

33170-2

FL by GA, Shinozuka 1996

C1315641

LN

33171-0

GS by GA, Rempen 1991

C1315642

LN

33172-8

HC by GA, ASUM 2000

C1315643

LN

33173-6

HC by GA, Hadlock 1984

C1315644

LN

33174-4

HC derived by GA, Chitty 1994

C1315645

LN

33175-1

HC by GA, Jeanty 1982

C1315646

LN

33176-9

HC by GA, Merz 1988

C1315647

LN

33177-7

Humerus Length by GA, ASUM 2000

C1315648

LN

33178-5

OFD by GA, ASUM 2000

C1315649

LN

33179-3

OFD by GA, Chitty 1994

C1315650

LN

33180-1

Radius by GA, Jeanty 1983

C1315651

LN

33181-9

TCD by GA Goldstein 1987

C1315652

LN

80416-1

HC/AC by GA, Campbell 1977

C4069376


DICOM PS3.16 2026a - Content Mapping Resource