| DICOM PS3.3 2026d - Information Object Definitions |
|---|
Table C.8-46. RT Prescription Module Attributes
|
Identification number of the Dose Reference. The Value of Dose Reference Number (300A,0012) shall be unique within the RT Plan in which it is created. |
|||
|
A unique identifier for a Dose Reference that can be used to link the same entity across multiple RT Plan objects. |
|||
|
Purpose(s) for which dose values in this Sequence Item are provided. Defined Terms: See Section C.8.8.10.1 and Section C.8.8.14.7. |
|||
|
Interpretation of the dose values. See Section C.8.8.10.1 and Section C.8.8.14.7. |
|||
|
Uniquely identifies ROI representing the dose reference specified by ROI Number (3006,0022) in Structure Set ROI Sequence (3006,0020) in Structure Set Module within RT Structure Set in Referenced Structure Set Sequence (300C,0060) in RT General Plan Module. Required if Dose Reference Structure Type (300A,0014) is POINT or VOLUME. |
|||
|
Coordinates (x,y,z) of Reference Point in the Patient-Based Coordinate System described in Section C.7.6.2.1.1 (mm). Required if Dose Reference Structure Type (300A,0014) is COORDINATES. |
|||
|
Dose (in Gy) from prior treatment to this Dose Reference (e.g., from a previous course of treatment). |
|||
|
Defined Terms:
|
|||
|
Relative importance of satisfying constraint, where high values represent more important constraints. |
|||
|
The dose (in Gy) that when reached or exceeded should cause some action to be taken. |
|||
|
The maximum dose (in Gy) that can be delivered to the dose reference. |
|||
|
Minimum permitted dose (in Gy) to Dose Reference if Dose Reference Type (300A,0020) is TARGET. |
|||
|
Prescribed dose (in Gy) to Dose Reference if Dose Reference Type (300A,0020) is TARGET. |
|||
|
Maximum permitted dose (in Gy) to Dose Reference if Dose Reference Type (300A,0020) is TARGET. |
|||
|
Maximum permitted fraction (in percent) of Target to receive less than the Target Prescription Dose if Dose Reference Type (300A,0020) is TARGET and Dose Reference Structure Type (300A,0014) is VOLUME. See Section C.8.8.10.1. |
|||
|
Maximum dose (in Gy) to entire Dose Reference if Dose Reference Type (300A,0020) is ORGAN_AT_RISK and Dose Reference Structure Type (300A,0014) is VOLUME. |
|||
|
Maximum permitted dose (in Gy) to any part of Dose Reference if Dose Reference Type (300A,0020) is ORGAN_AT_RISK and Dose Reference Structure Type (300A,0014) is VOLUME. |
|||
|
Maximum dose (in Gy) to non-overdosed part of Dose Reference if Dose Reference Type (300A,0020) is ORGAN_AT_RISK and Dose Reference Structure Type (300A,0014) is VOLUME. |
|||
|
Maximum permitted fraction (in percent) of the Organ at Risk to receive more than the Organ at Risk Maximum Dose if Dose Reference Type (300A,0020) is ORGAN_AT_RISK and Dose Reference Structure Type (300A,0014) is VOLUME. |
| DICOM PS3.3 2026d - Information Object Definitions |
|---|