C.8.35.4 Confocal Microscopy Functional Group Macros

The following section contain Functional Group Macros specific to the Confocal Microscopy Image IOD and the Confocal Microscopy Tiled Pyramidal Image IOD.

C.8.35.4.1 Confocal Microscopy Image Frame Type Macro

Table C.8.35.4.1-1specifies the Attributes of the Confocal Microscopy Image Frame Type Macro

Table C.8.35.4.1-1. Confocal Microscopy Image Frame Type Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Confocal Microscopy Image Frame Type Sequence

(0048,0116)

1

Identifies the characteristics of this Confocal Microscopy Image Frame.

Only a single Item shall be included in this Sequence.

>Frame Type

(0008,9007)

1

Type of Frame. A multi-valued Attribute analogous to Image Type (0008,0008). Enumerated Values and Defined Terms are the same as those for the four Values of Image Type (0008,0008). See Section C.8.35.1.1.1.