| DICOM PS3.3 2025e - Information Object Definitions |
|---|
The following sections contain Functional Group Macros specific to the VL Whole Slide Microscopy Image IOD.
The Attribute descriptions in the Functional Group Macros are written as if they were applicable to a single Frame (i.e., the Macro is part of the Per-Frame Functional Groups Sequence). If an Attribute is applicable to all Frames (i.e., the Macro is part of the Shared Functional Groups Sequence) the phrase "this Frame" in the Attribute description shall be interpreted to mean "for all Frames".
Table C.8.12.6.1-1 specifies the Attributes of the Plane Position (Slide) Macro.
Table C.8.12.6.1-1. Plane Position (Slide) Macro Attributes
|
Describes position of Frame in the Total Pixel Matrix and in the Slide Coordinate System Frame of Reference. |
|||
|
The column position of the top left hand pixel of the Frame in the Total Pixel Matrix (see Section C.8.12.4.1.1). The column position of the top left pixel of the Total Pixel Matrix is 1. |
|||
|
The row position of the top left hand pixel of the Frame in the Total Pixel Matrix (see Section C.8.12.4.1.1). The row position of the top left pixel of the Total Pixel Matrix is 1. |
|||
|
The X offset in mm from the Origin of the Slide Coordinate System. See Figure C.8-16. |
|||
|
The Y offset in mm from the Origin of the Slide Coordinate System. See Figure C.8-16. |
|||
|
The Z offset in µm from the Origin of the Slide Coordinate System, nominally the surface of the glass slide substrate. See Figure C.8-17 |
| DICOM PS3.3 2025e - Information Object Definitions |
|---|