The following Multi-Resolution Pyramid IE Modules are common to all Composite Image IODs that reference the Multi-Resolution Pyramid IE.
Table C.7.11.1-1 specifies the Attributes that identify and describe general information about a Multi-Resolution Pyramid.
Table C.7.11.1-1. Multi-Resolution Pyramid Module Attributes
Attribute Name |
Tag |
Type |
Attribute Description |
---|---|---|---|
Pyramid UID |
(0008,0019) |
1 |
Unique identifier of a multi-resolution representation of an image. |
Pyramid Label |
(0020,0027) |
3 |
User-defined label identifying a multi-resolution representation of an image. |
Pyramid Description |
(0008,1088) |
3 |
User-defined description of a multi-resolution representation of an image. |