DICOM PS3.3 2025b - Information Object Definitions |
---|
This Module specifies the Attributes of the Content Assessment Results Module, and describes the results of the assessment of a SOP Instance.
The type of observations that are included in the results is up to the implementation. Although all observations with the Observation Significance (0082,0008) with Value MAJOR are included, inclusion of other observation is on the discretion of the implementation.
Table C.33.1-1. Content Assessment Results Module Attributes
Identifies the set of assessments to which this assessment result belongs. |
|||
>Include Table C.17-3b “Identified Person or Device Macro Attributes” |
|||
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
|||
SOP Instance(s) used by the assessor to compare to the assessed SOP Instances. |
|||
>>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
|||
Summary of the assessment result. The relationship between the Values of Observation Type (0082,0008) found and the Assessment Summary Value is implementation dependent. Enumerated Values:
|
|||
Human-readable summary description of the assessment result. |
|||
List of Resources that contain information considered pertinent for the assessment. |
|||
Retrieval access path to resource. Includes fully specified scheme, authority, path, and query in accordance with [RFC3986]. |
|||
Observations made during the assessment. Required if Number of Assessment Observations (0082,0006) is not zero. The number of Items included in the Sequence shall equal the Value of Number of Assessment Observations (0082,0006). |
|||
The significance of this observation regarding the quality or effectiveness of the assessed SOP Instance of this observation. Enumerated Values:
|
|||
Structured Constraint(s) that were used to make this observation and description of conformance or violation. |
|||
>>Include Table 10.25-1 “Attribute Value Constraint Macro Attributes” |
|||
DICOM PS3.3 2025b - Information Object Definitions |
---|