C.7.3.2 Clinical Trial Series Module

Table C.7-5b specifies the Attributes of the Clinical Trial Series Module, which identify a Series in the context of a clinical trial or research.

Table C.7-5b. Clinical Trial Series Module Attributes

Attribute Name

Tag

Type

Attribute Description

Clinical Trial Coordinating Center Name

(0012,0060)

2

The name of the institution that is responsible for coordinating the medical imaging data for the clinical trial or research. See Section C.7.3.2.1.1.

Clinical Trial Series ID

(0012,0071)

3

An identifier of the Series in the context of a clinical trial or research. See Section C.7.3.2.1.2.

Issuer of Clinical Trial Series ID

(0012,0073)

3

Identifier of the Assigning Authority that issued the Clinical Trial Series ID.

Clinical Trial Series Description

(0012,0072)

3

A description of the Series in the context of a clinical trial or research. See Section C.7.3.2.1.2.


C.7.3.2.1 Clinical Trial Series Module Attribute Descriptions
C.7.3.2.1.1 Clinical Trial Coordinating Center Name

The Clinical Trial Coordinating Center Name (0012,0060) identifies the institution responsible for coordinating the collection of images and associated data for subjects enrolled in the clinical trial or research.

C.7.3.2.1.2 Clinical Trial Series Identifier and Description

The Clinical Trial Series ID (0012,0071) and Clinical Trial Series Description (0012,0072) can be used to identify and describe a Series within the context of a clinical trial or research without requiring the replacement of the Values in Series Number (0020,0011) and Series Description (0008,103E) in the General Series Module, whose manufacturer or user provided values may be relevant and important to retain.