| DICOM PS3.3 2026c - Information Object Definitions |
|---|
The following Study IE Modules are common to all Composite IODs that reference the Study IE. These Modules contain Attributes of the Patient and Study that are needed for interpretation of the Composite Instances. They contain Attributes that are also in the Section C.2 Patient Modules and the Section C.4 Study Modules.
Table C.7-3 specifies the Attributes, which identify and describe the Study performed upon the Patient.
Table C.7-3. General Study Module Attributes
|
>Include Table 10-1 “Person Identification Macro Attributes” |
|||
|
Identification of the consulting physician(s). One or more Items are permitted in this Sequence. If more than one Item, the number and order shall correspond to the Value of Consulting Physician's Name (0008,009C), if present. |
|||
|
>Include Table 10-1 “Person Identification Macro Attributes” |
|||
|
A departmental Information System generated number that identifies the Imaging Service Request. |
|||
|
Identifier of the Assigning Authority that issued the Accession Number. |
|||
|
>Include Table 10-17 “HL7v2 Hierarchic Designator Macro Attributes” |
|||
|
Institution-generated description or classification of the Study performed. |
|||
|
Names of the physician(s) who are responsible for overall Patient care at time of Study (see Section C.7.3.1 for Performing Physician). |
|||
|
Identification of the physician(s) who are responsible for overall Patient care at time of Study. One or more Items are permitted in this Sequence. If more than one Item, the number and order shall correspond to the Value of Physician(s) of Record (0008,1048), if present. |
|||
|
>Include Table 10-1 “Person Identification Macro Attributes” |
|||
|
Identification of the physician(s) reading the Study. One or more Items are permitted in this Sequence. If more than one Item, the number and order shall correspond to the Value of Name of Physician(s) Reading Study (0008,1060), if present. |
|||
|
>Include Table 10-1 “Person Identification Macro Attributes” |
|||
|
Institutional department, unit or service where the request initiated. |
|||
|
Institutional department, unit or service where the request initiated. |
|||
|
A Sequence that provides reference to a Study. One or more Items are permitted in this Sequence. See Section 10.6.1. |
|||
|
>Include Table 10-11 “SOP Instance Reference Macro Attributes” |
|||
Both Requesting Service (0032,1033) and Requesting Service Code Sequence (0032,1034) are defined in this table; the latter is preferred, but the former may be copied from an HL7 message whether or not there is also the ability to map it to a coded form (e.g., with only ORC-17 component 1 valued).
Requesting Service (0032,1033) and/or Requesting Service Code Sequence (0032,1034) may be used in the absence of a specific request or order, to describe the service involved or associated with acquiring the Study.
The model used for application of Attributes related to different functions of Physicians involved in the care of a Patient is shown in Figure C.7.2-1. Figure C.7.2-1 shows some of the relationships and information flows between physician roles that might be present in some healthcare business models.
There can be an overlap of functions provided by any given physician. In this case, the various Attributes specifying the different roles would convey the same physician name.
| DICOM PS3.3 2026c - Information Object Definitions |
|---|