DICOM PS3.3 2022b - Information Object Definitions |
---|
Table C.4-10. Scheduled Procedure Step Module Attributes
One or more Scheduled Procedure Steps for one Requested Procedure. |
||
The AE title of the modality on which the Scheduled Procedure Step is scheduled to be performed. |
||
An institution defined name for the modality on which the Scheduled Procedure Step is scheduled to be performed. |
||
The location at which the Procedure Step is scheduled to be performed. |
||
Defined Procedure Protocol Instance(s) specified for the Scheduled Procedure Step. |
||
Prior Performed Procedure Protocol Instance(s) that is to be repeated for the Scheduled Procedure Step. |
||
Date on which the Scheduled Procedure Step is scheduled to start. |
||
Time at which the Scheduled Procedure Step is scheduled to start. |
||
Date on which the Scheduled Procedure Step is scheduled to end. |
||
Time at which the Scheduled Procedure Step is scheduled to end. |
||
Name of the physician scheduled to administer the Scheduled Procedure Step. |
||
Identification of the physician scheduled to administer the Scheduled Procedure Step. Only a single Item shall be included in this Sequence. |
||
>>Include Table 10-1 “Person Identification Macro Attributes” |
||
Institution-generated description or classification of the Scheduled Procedure Step to be performed. |
||
Sequence describing the Scheduled Protocol following a specified coding scheme. One or more Items shall be included in this Sequence. |
||
Sequence that specifies the context for the Scheduled Protocol Code Sequence (0040,0008) Item. One or more Items shall be included in this Sequence. See Section C.4.10.1. |
||
>>>Include Table 10-2 “Content Item Macro Attributes” |
||
Sequence that specifies modifiers for a Protocol Context Content Item. One or more Items shall be included in this Sequence. See Section C.4.10.1. |
||
>>>>Include Table 10-2 “Content Item Macro Attributes” |
||
A Real World condition that may affect the selection of the Scheduled Procedure Step. |
||
Type of device, process or method for which the Scheduled Procedure Step is scheduled. See Section C.7.3.1.1.1 for Defined Terms. |
||
Contrast agent requested for use in the Scheduled Procedure Step. |
||
Medication to be administered at the beginning of the Scheduled Procedure Step, e.g., Nuclear Medicine radiopharmaceutical. |
||
The anatomical orientation type appropriate for this Patient. |
||
Sequence of Items identifying specimens to be imaged in the identified Scheduled Procedure Step(s), with their characteristics. |
||
Barcode interpreted from a scanned label. Note
|
The Protocol Context Sequence (0040,0440) allows the specification of parameters that further qualify the scheduled protocol, provided through a set of generic name/value pairs of context Content Items.
This allows the specification of clinical, acquisition, or procedural qualifiers for the scheduled protocol, such as a specific body part, imaging technique, or parameters of a preparatory event (e.g., radionuclide injection). Specific uses of this Sequence may be documented in a Template defined in accordance with PS3.16.
DICOM PS3.3 2022b - Information Object Definitions |
---|