| DICOM PS3.3 2026c - Information Object Definitions |
|---|
The relative URI reference within encapsulated document Value shall be encoded as a relative URI reference [RFC3986], with the following restrictions:
The base path (URI) to which the reference is relative is the location where the referencing file would hypothetically be written, were it to be unencapsulated and written to a file, such that the set of related encapsulated documents share the same base path.
The path shall not refer to a higher level in the file system hierarchy (i.e., use of ".." is not permitted).
File name extensions corresponding to executable file types (exe, dll, etc.) are not permitted.
The following are examples of valid relative URI references:
The following are examples of invalid relative URI references:
| DICOM PS3.3 2026c - Information Object Definitions |
|---|