DICOM PS3.3 2026c - Information Object Definitions

B.26.2 IOD Modules

Table B.26.2-1 lists the Modules that make up the Unified Procedure Step IOD.

Table B.26.2-1. Unified Procedure Step IOD Modules

Module

Reference

Module Description

SOP Common

C.12.1

Contains SOP common information

Unified Procedure Step Relationship

C.30.4

References the related SOPs and IEs

Unified Procedure Step Scheduled Procedure Information

C.30.2

Describes the UPS task to be performed including information about place, time, priority and input data

Unified Procedure Step Progress Information

C.30.1

Describes the progress of a UPS task

Unified Procedure Step Performed Procedure Information

C.30.3

Describes the work performed including information about status, place, time and result data

Patient Demographic

C.2.3

Describes the Patient at the time of scheduling

Patient Medical

C.2.4

Describes the Patient's medical state or history

Visit Identification

C.3.2

Attributes relevant to identifying a Visit

Visit Status

C.3.3

Attributes relevant to the Patient's stay with the healthcare provider

Visit Admission

C.3.4

Attributes relevant to admitting a Patient during a Visit


DICOM PS3.3 2026c - Information Object Definitions