Stored Print Storage
|
1.2.840.10008.5.1.1.27
|
Yes
|
No
|
Hardcopy Grayscale Image Storage
|
1.2.840.10008.5.1.1.29
|
Yes
|
No
|
Hardcopy Color Image Storage
|
1.2.840.10008.5.1.1.30
|
Yes
|
No
|
Computed Radiography Image Storage
|
1.2.840.10008.5.1.4.1.1.1
|
Yes
|
No
|
Digital X-Ray Image Storage - For Presentation
|
1.2.840.10008.5.1.4.1.1.1.1
|
Yes
|
No
|
Digital X-Ray Image Storage - For Processing
|
1.2.840.10008.5.1.4.1.1.1.1.1
|
Yes
|
No
|
Digital Mammography X-Ray Image Storage - For Presentation
|
1.2.840.10008.5.1.4.1.1.1.2
|
Yes
|
No
|
Digital Mammography X-Ray Image Storage - For Processing
|
1.2.840.10008.5.1.4.1.1.1.2.1
|
Yes
|
No
|
Digital Intra-oral X-Ray Image Storage - For Presentation
|
1.2.840.10008.5.1.4.1.1.1.3
|
Yes
|
No
|
Digital Intra-oral X-Ray Image Storage - For Processing
|
1.2.840.10008.5.1.4.1.1.1.3.1
|
Yes
|
No
|
CT Image Storage
|
1.2.840.10008.5.1.4.1.1.2
|
Yes
|
No
|
Ultrasound Multi-frame Image Storage (Retired)
|
1.2.840.10008.5.1.4.1.1.3
|
Yes
|
No
|
Ultrasound Multi-frame Image Storage
|
1.2.840.10008.5.1.4.1.1.3.1
|
Yes
|
No
|
MR Image Storage
|
1.2.840.10008.5.1.4.1.1.4
|
Yes
|
No
|
Enhanced MR Image Storage
|
1.2.840.10008.5.1.4.1.1.4.1
|
Yes
|
No
|
MR Spectroscopy Storage
|
1.2.840.10008.5.1.4.1.1.4.2
|
Yes
|
No
|
Standalone Modality LUT Storage
|
1.2.840.10008.5.1.4.1.1.10
|
Yes
|
No
|
Standalone VOI LUT Storage
|
1.2.840.10008.5.1.4.1.1.11
|
Yes
|
No
|
Grayscale Softcopy Presentation State Storage
|
1.2.840.10008.5.1.4.1.1.11.1
|
Yes
|
No
|
X-Ray Angiographic Image Storage
|
1.2.840.10008.5.1.4.1.1.12.1
|
Yes
|
No
|
X-Ray Radiofluoroscopic Image Storage
|
1.2.840.10008.5.1.4.1.1.12.2
|
Yes
|
No
|
X-Ray Angiographic Bi-Plane Image Storage (Retired)
|
1.2.840.10008.5.1.4.1.1.12.3
|
Yes
|
No
|
Nuclear Medicine Image Storage
|
1.2.840.10008.5.1.4.1.1.20
|
Yes
|
No
|
Raw Data Storage
|
1.2.840.10008.5.1.4.1.1.66
|
Yes
|
No
|
VL Image Storage (Retired)
|
1.2.840.10008.5.1.4.1.1.77.1
|
Yes
|
No
|
VL Multi-frame Image Storage (Retired)
|
1.2.840.10008.5.1.4.1.1.77.2
|
Yes
|
No
|
VL Endoscopic Image Storage
|
1.2.840.10008.5.1.4.1.1.77.1.1
|
Yes
|
No
|
VL Microscopic Image Storage
|
1.2.840.10008.5.1.4.1.1.77.1.2
|
Yes
|
No
|
VL Slide-Coordinates Microscopic Image Storage
|
1.2.840.10008.5.1.4.1.1.77.1.3
|
Yes
|
No
|
VL Photographic Image Storage
|
1.2.840.10008.5.1.4.1.1.77.1.4
|
Yes
|
No
|
Basic Text SR
|
1.2.840.10008.5.1.4.1.1.88.11
|
Yes
|
No
|
Enhanced SR
|
1.2.840.10008.5.1.4.1.1.88.22
|
Yes
|
No
|
Comprehensive SR
|
1.2.840.10008.5.1.4.1.1.88.33
|
Yes
|
No
|
Mammography CAD SR
|
1.2.840.10008.5.1.4.1.1.88.50
|
Yes
|
No
|
Key Object Selection Document
|
1.2.840.10008.5.1.4.1.1.88.59
|
Yes
|
No
|
Positron Emission Tomography Image Storage
|
1.2.840.10008.5.1.4.1.1.128
|
Yes
|
No
|
Standalone PET Curve Storage
|
1.2.840.10008.5.1.4.1.1.129
|
Yes
|
No
|
RT Image Storage
|
1.2.840.10008.5.1.4.1.1.481.1
|
Yes
|
No
|
RT Dose Storage
|
1.2.840.10008.5.1.4.1.1.481.2
|
Yes
|
No
|
RT Structure Set Storage
|
1.2.840.10008.5.1.4.1.1.481.3
|
Yes
|
No
|
RT Beams Treatment Record Storage
|
1.2.840.10008.5.1.4.1.1.481.4
|
Yes
|
No
|
RT Plan Storage
|
1.2.840.10008.5.1.4.1.1.481.5
|
Yes
|
No
|
RT Brachy Treatment Record Storage
|
1.2.840.10008.5.1.4.1.1.481.6
|
Yes
|
No
|
RT Treatment Summary Record Storage
|
1.2.840.10008.5.1.4.1.1.481.7
|
Yes
|
No
|