Scheduled Procedure Step
|
Scheduled Procedure Step Sequence
|
(0040,0100)
|
|
|
|
>Scheduled Station AE Title
|
(0040,0001)
|
|
|
DICOMRis generated
|
>Scheduled Procedure Step Start Date
|
(0040,0002)
|
Quantity/Timing
|
ORM OBR:27
|
DICOMRis generated
|
>Scheduled Procedure Step Start Time
|
(0040,0003)
|
Quantity/Timing
|
ORM OBR:27
|
DICOMRis generated
|
>Modality
|
(0008,0060)
|
|
|
DICOMRis generated
|
>Scheduled Performing Physician's Name
|
(0040,0006)
|
Technician
|
ORM OBR:34
|
|
>Scheduled Procedure Step Description
|
(0040,0007)
|
|
|
DICOMRis generated
|
>Scheduled Station Name
|
(0040,0010)
|
|
|
DICOMRis generated
|
>Scheduled Procedure Step Location
|
(0040,0011)
|
|
|
DICOMRis generated
|
>Scheduled Protocol Code Sequence
|
(0040,0008)
|
|
|
|
>>Code Value
|
(0008,0100)
|
|
|
DICOMRis generated
|
>>Coding Scheme Designator
|
(0008,0102)
|
|
|
DICOMRis generated
|
>>Code Meaning
|
(0008,0104)
|
|
|
DICOMRis generated
|
>Pre-Medication
|
(0040,0012)
|
|
|
DICOMRis generated
|
>Scheduled Procedure Step ID
|
(0040,0009)
|
|
|
DICOMRis generated
|
>Requested Contrast Agent
|
(0032,1070)
|
|
|
DICOMRis generated
|
>Scheduled Procedure Step Status
|
(0040,0020)
|
|
|
DICOMRis generated
|
>Comments on the Scheduled Procedure Step
|
(0040,0400)
|
|
|
DICOMRis generated
|
Requested Procedure
|
Requested Procedure ID
|
(0040,1001)
|
|
|
DICOMRis generated
|
Requested Procedure Description
|
(0032,1060)
|
|
|
DICOMRis generated
|
Requested Procedure Code Sequence
|
(0032,1064)
|
|
|
|
>Code Value
|
(0008,0100)
|
Universal Service Id
|
ORM OBR:44
|
The value in the HL7 attribute is mapped to one or more procedure codes in the DICOMRis database. The mapping is configurable
|
>Coding Scheme Designator
|
(0008,0102)
|
Universal Service Id
|
ORM OBR:44
|
Maps to a site-defined Coding Scheme, the LOINC Coding Scheme or the DICOMRis internal Coding Scheme
|
>Code Meaning
|
(0008,0008)
|
|
|
DICOMRis generated
|
Study Instance UID
|
(0020,000D)
|
|
|
DICOMRis generated
|
Referenced Study Sequence
|
(0008,1110)
|
|
|
|
>Referenced SOP Class UID
|
(0008,1150)
|
|
|
DICOMRis generated
|
>Referenced SOP Instance UID
|
(0008,1155)
|
|
|
DICOMRis generated
|
Requested Procedure Priority
|
(0040,1003)
|
|
ORM OBR:27
|
|
Patient Transport Arrangements
|
(0040,1004)
|
|
ORM OBR:30
|
|
Reason for the Requested Procedure
|
(0040,0040)
|
|
|
DICOMRis generated
|
Imaging Service Request
|
Accession Number
|
(0008,0050)
|
|
|
DICOMRis generated
|
Requesting Physician
|
(0032,1032)
|
|
ORM OBR:16
|
|
Referring Physician's Name
|
(0008,0090)
|
|
ORM PV1:8
|
|
Reason for the Imaging Service
Request
|
(0040,2001)
|
Reason for Study
|
ORM OBR:31
|
|
Order Entered By
|
(0040,2008)
|
Entered By
|
ORM ORC:10
|
|
Order Enterer's Location
|
(0040,2009)
|
Entering Organization
|
ORM ORC:17
|
|
Visit Identification
|
Admission ID
|
(0038,0010)
|
|
ADT PID:3
|
|
Admitting Diagnosis Description
|
(0008,1080)
|
|
ADT DG1:4
|
|
Admitting Diagnoses Code Sequence
|
(0008,1084)
|
|
|
|
>Code Value
|
(0008,0008)
|
|
ADT DG1:3
|
|
>Coding Scheme Designator
|
(0008,0008)
|
|
ADT DG1:2
|
|
>Code Meaning
|
(0008,0008)
|
|
|
|
Patient Identification
|
Patient's Name
|
(0010,0010)
|
|
ADT PID:5
|
|
Patient ID
|
(0010,0020)
|
|
ADT PID:3
|
|
Patient Demographics
|
Patients Birth Date
|
(0010,0030)
|
|
ADT PID:7
|
|
Patient's Sex
|
(0010,0040)
|
|
ADT PID:8
|
|
Patient's Weight
|
(0010,1030)
|
|
ADT OBX:5
|
|
Ethnic Group
|
(0010,2160)
|
|
ADT PID:10
|
|
Patient Comment
|
(0010,4000)
|
|
ORM NTE:3
|
|
Patient Medical
|
Patient State
|
(0038,0500)
|
Danger Code
|
ORM OBR:12
|
|
Pregnancy Status
|
(0010,21C0)
|
Filler Field 1
|
ORM OBR:20
|
|
Medical Alerts
|
(0010,2000)
|
Relevant Clinical Information
|
ORM OBR:13
|
|
Allergies
|
(0010,2110)
|
|
ADT AL1:3
|
|
Last Menstrual Date
|
(0010,21D0)
|
Filler Field 1
|
ORM OBR:20
|
|