DICOM PS3.2 2022b - Conformance |
---|
This AE complies with Section 10.6 in PS3.18 , specification for QIDO-RS.
Table K.4.2-1. QIDO-RS Search for Studies Specification
Restricted to "multipart/related; type=application/dicom+xml" or "application/dicom+json" |
|
See Table K.4.2-1a |
|
See Table K.4.2-1a |
|
Literal, case insensitive. Section K.4.2.2 “Extended Negotiation”. |
Types of Matching (see Section C.2.2.2 “Attribute Matching” in PS3.4 ) :
"S" indicates the identifier attribute uses Single Value Matching
"L" indicates UID List Matching
"U" indicates Universal Matching.
If only Universal Matching is supported for an attribute then that attribute can only be passed as an "includefield" query key
"*" indicates wild card matching
"SEQUENCE" indicates Sequence Matching
"NONE" indicates that no matching is supported, but that values for this Element requested will be returned with all requests
"UNIQUE" indicates that this is the Unique Key for that query level, in which case Universal Matching or Single Value Matching is used depending on the query level (see Section C.2.2.1.1 “Unique Keys” in PS3.4 ).
Table K.4.2-2. QIDO-RS Search for Series Specification
Restricted to "multipart/related; type=application/dicom+xml" or "application/dicom+json" |
|
See Table K.4.2-2a |
|
See Table K.4.2-2a |
|
Types of matching: Section K.4.2.1.1 “QIDO-RS Search for Studies”.
Table K.4.2-3. QIDO-RS Search for Instances Specification
Restricted to "multipart/related; type=application/dicom+xml" or "application/dicom+json" |
|
See Table K.4.2-3a |
|
See Table K.4.2-3a |
|
Types of matching: Section K.4.2.1.1 “QIDO-RS Search for Studies”.
EXAMPLE-QIDO-SERVICE limits the number of simultaneous RS requests. Additional requests will be queued after the HTTP connection is accepted. When an earlier request completes, a pending request will proceed.
The EXAMPLE-QIDO-SERVICE shall provide a response message header containing the appropriate status code indicating success, warning, or failure as shown in Table K.4.2-5.
Table K.4.2-5. HTTP Standard Response Codes
DICOM PS3.2 2022b - Conformance |
---|