DICOM PS3.2 2022d - Conformance
G.4.2.4.2 Association Policies
G.4.2.4.2.1 General

MOVE-SCU initiates but never accepts associations.

Table G.4.2-21. Maximum PDU Size Received as a SCP for MOVE-SCU

Maximum PDU size received

Unlimited


G.4.2.4.2.2 Number of Associations

Table G.4.2-27. Number of Associations as a SCP for MOVE-SCU

Maximum number of simultaneous associations

1


G.4.2.4.2.3 Asynchronous Nature

MOVE-SCU will only allow a single outstanding operation on an Association. Therefore, MOVE-SCU will not perform asynchronous operations window negotiation.

G.4.2.4.2.4 Implementation Identifying Information

Table G.4.2-23. DICOM Implementation Class and Version for MOVE-SCU

Implementation Class UID

1.2.840.999999.3.6

Implementation Version Name

Viewer1.0


DICOM PS3.2 2022d - Conformance