DICOM PS3.2 2022d - Conformance

D.4.2.3 STORAGE-SCU

D.4.2.3.1 SOP Classes

STORAGE-SCU provide Standard Conformance to the following SOP Class(es) :

Table D.4.2-12. SOP Classes Supported By STORAGE-SCU

SOP Class Name

SOP Class UID

SCU

SCP

Stored Print Storage

1.2.840.10008.5.1.1.27

Yes

No

Hardcopy Grayscale Image Storage

1.2.840.10008.5.1.1.29

Yes

No

Hardcopy Color Image Storage

1.2.840.10008.5.1.1.30

Yes

No

Computed Radiography Image Storage

1.2.840.10008.5.1.4.1.1.1

Yes

No

Digital X-Ray Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.1.1

Yes

No

Digital X-Ray Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.1.1.1

Yes

No

Digital Mammography X-Ray Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.1.2

Yes

No

Digital Mammography X-Ray Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.1.2.1

Yes

No

Digital Intra-oral X-Ray Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.1.3

Yes

No

Digital Intra-oral X-Ray Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.1.3.1

Yes

No

CT Image Storage

1.2.840.10008.5.1.4.1.1.2

Yes

No

Ultrasound Multi-frame Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.3

Yes

No

Ultrasound Multi-frame Image Storage

1.2.840.10008.5.1.4.1.1.3.1

Yes

No

MR Image Storage

1.2.840.10008.5.1.4.1.1.4

Yes

No

Enhanced MR Image Storage

1.2.840.10008.5.1.4.1.1.4.1

Yes

No

MR Spectroscopy Storage

1.2.840.10008.5.1.4.1.1.4.2

Yes

No

Standalone Modality LUT Storage

1.2.840.10008.5.1.4.1.1.10

Yes

No

Standalone VOI LUT Storage

1.2.840.10008.5.1.4.1.1.11

Yes

No

Grayscale Softcopy Presentation State Storage

1.2.840.10008.5.1.4.1.1.11.1

Yes

No

X-Ray Angiographic Image Storage

1.2.840.10008.5.1.4.1.1.12.1

Yes

No

X-Ray Radiofluoroscopic Image Storage

1.2.840.10008.5.1.4.1.1.12.2

Yes

No

X-Ray Angiographic Bi-Plane Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.12.3

Yes

No

Nuclear Medicine Image Storage

1.2.840.10008.5.1.4.1.1.20

Yes

No

Raw Data Storage

1.2.840.10008.5.1.4.1.1.66

Yes

No

VL Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.77.1

Yes

No

VL Multi-frame Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.77.2

Yes

No

VL Endoscopic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.1

Yes

No

VL Microscopic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.2

Yes

No

VL Slide-Coordinates Microscopic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.3

Yes

No

VL Photographic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.4

Yes

No

Basic Text SR

1.2.840.10008.5.1.4.1.1.88.11

Yes

No

Enhanced SR

1.2.840.10008.5.1.4.1.1.88.22

Yes

No

Comprehensive SR

1.2.840.10008.5.1.4.1.1.88.33

Yes

No

Mammography CAD SR

1.2.840.10008.5.1.4.1.1.88.50

Yes

No

Key Object Selection Document

1.2.840.10008.5.1.4.1.1.88.59

Yes

No

Positron Emission Tomography Image Storage

1.2.840.10008.5.1.4.1.1.128

Yes

No

Standalone PET Curve Storage

1.2.840.10008.5.1.4.1.1.129

Yes

No

RT Image Storage

1.2.840.10008.5.1.4.1.1.481.1

Yes

No

RT Dose Storage

1.2.840.10008.5.1.4.1.1.481.2

Yes

No

RT Structure Set Storage

1.2.840.10008.5.1.4.1.1.481.3

Yes

No

RT Beams Treatment Record Storage

1.2.840.10008.5.1.4.1.1.481.4

Yes

No

RT Plan Storage

1.2.840.10008.5.1.4.1.1.481.5

Yes

No

RT Brachy Treatment Record Storage

1.2.840.10008.5.1.4.1.1.481.6

Yes

No

RT Treatment Summary Record Storage

1.2.840.10008.5.1.4.1.1.481.7

Yes

No


DICOM PS3.2 2022d - Conformance