DICOM PS3.2 2022d - Conformance

D.4.2.2 STORAGE-SCP

D.4.2.2.1 SOP Classes

STORAGE-SCP provide Standard Conformance to the following SOP Class(es) :

Table D.4.2-6. SOP Classes Supported By STORAGE-SCP

SOP Class Name

SOP Class UID

SCU

SCP

Stored Print Storage

1.2.840.10008.5.1.1.27

No

Yes

Hardcopy Grayscale Image Storage

1.2.840.10008.5.1.1.29

No

Yes

Hardcopy Color Image Storage

1.2.840.10008.5.1.1.30

No

Yes

Computed Radiography Image Storage

1.2.840.10008.5.1.4.1.1.1

No

Yes

Digital X-Ray Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.1.1

No

Yes

Digital X-Ray Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.1.1.1

No

Yes

Digital Mammography X-Ray Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.1.2

No

Yes

Digital Mammography X-Ray Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.1.2.1

No

Yes

Digital Intra-oral X-Ray Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.1.3

No

Yes

Digital Intra-oral X-Ray Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.1.3.1

No

Yes

CT Image Storage

1.2.840.10008.5.1.4.1.1.2

No

Yes

Ultrasound Multi-frame Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.3

No

Yes

Ultrasound Multi-frame Image Storage

1.2.840.10008.5.1.4.1.1.3.1

No

Yes

MR Image Storage

1.2.840.10008.5.1.4.1.1.4

No

Yes

Enhanced MR Image Storage

1.2.840.10008.5.1.4.1.1.4.1

No

Yes

MR Spectroscopy Storage

1.2.840.10008.5.1.4.1.1.4.2

No

Yes

Standalone Modality LUT Storage

1.2.840.10008.5.1.4.1.1.10

No

Yes

Standalone VOI LUT Storage

1.2.840.10008.5.1.4.1.1.11

No

Yes

Grayscale Softcopy Presentation State Storage

1.2.840.10008.5.1.4.1.1.11.1

No

Yes

X-Ray Angiographic Image Storage

1.2.840.10008.5.1.4.1.1.12.1

No

Yes

X-Ray Radiofluoroscopic Image Storage

1.2.840.10008.5.1.4.1.1.12.2

No

Yes

X-Ray Angiographic Bi-Plane Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.12.3

No

Yes

Nuclear Medicine Image Storage

1.2.840.10008.5.1.4.1.1.20

No

Yes

Raw Data Storage

1.2.840.10008.5.1.4.1.1.66

No

Yes

VL Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.77.1

No

Yes

VL Multi-frame Image Storage (Retired)

1.2.840.10008.5.1.4.1.1.77.2

No

Yes

VL Endoscopic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.1

No

Yes

VL Microscopic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.2

No

Yes

VL Slide-Coordinates Microscopic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.3

No

Yes

VL Photographic Image Storage

1.2.840.10008.5.1.4.1.1.77.1.4

No

Yes

Basic Text SR

1.2.840.10008.5.1.4.1.1.88.11

No

Yes

Enhanced SR

1.2.840.10008.5.1.4.1.1.88.22

No

Yes

Comprehensive SR

1.2.840.10008.5.1.4.1.1.88.33

No

Yes

Mammography CAD SR

1.2.840.10008.5.1.4.1.1.88.50

No

Yes

Key Object Selection Document

1.2.840.10008.5.1.4.1.1.88.59

No

Yes

Positron Emission Tomography Image Storage

1.2.840.10008.5.1.4.1.1.128

No

Yes

Standalone PET Curve Storage

1.2.840.10008.5.1.4.1.1.129

No

Yes

RT Image Storage

1.2.840.10008.5.1.4.1.1.481.1

No

Yes

RT Dose Storage

1.2.840.10008.5.1.4.1.1.481.2

No

Yes

RT Structure Set Storage

1.2.840.10008.5.1.4.1.1.481.3

No

Yes

RT Beams Treatment Record Storage

1.2.840.10008.5.1.4.1.1.481.4

No

Yes

RT Plan Storage

1.2.840.10008.5.1.4.1.1.481.5

No

Yes

RT Brachy Treatment Record Storage

1.2.840.10008.5.1.4.1.1.481.6

No

Yes

RT Treatment Summary Record Storage

1.2.840.10008.5.1.4.1.1.481.7

No

Yes


DICOM PS3.2 2022d - Conformance