<?xml version="1.0" encoding="utf-8" standalone="no"?>
<book xmlns="http://docbook.org/ns/docbook" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xl="http://www.w3.org/1999/xlink" label="PS3.21" version="5.0" xml:id="PS3.21">

    <title>Digital Imaging and Communications in Medicine (DICOM)</title>
    <subtitle>Sup 244 - Frame Deflate Transfer Syntax</subtitle>
    <info>
        <author>
            <orgname>DICOM Standards Committee - Working Group 4 - Compression</orgname>
            <address>
            <street>1300 N. 17th Street Suite 1752</street>
            <city>Rosslyn</city>
            <state>VA</state>
            <postcode>22209</postcode>
            <country>USA</country>
         </address>
        </author>
        <copyright>
            <year>2024</year>
            <holder>NEMA</holder>
        </copyright>
        <releaseinfo>Status: Draft after Public Comment</releaseinfo>
        <pubdate>2024/07/06</pubdate>
        <legalnotice>
            <para>This supplement is prepared pursuant to work item: 2023-10-A</para>
        </legalnotice>
    </info>

    <chapter>
        <title>Document History</title>
        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <thead>
                    <tr valign="top">
                        <th rowspan="1" colspan="1">
                            <para>Document Version</para>
                        </th>
                        <th rowspan="1" colspan="1">
                            <para>Date</para>
                        </th>
                        <th rowspan="1" colspan="1">
                            <para>Content</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td rowspan="1" colspan="1">
                            <para>01</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>2023/12/05</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>First draft for review by WG 4</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td rowspan="1" colspan="1">
                            <para>02</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>2024/01/03</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>Draft for first read by WG 6</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td rowspan="1" colspan="1">
                            <para>03</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>2024/01/09</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>After WG 6 review</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td rowspan="1" colspan="1">
                            <para>04</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>2024/03/19</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>Public Comment Draft</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td rowspan="1" colspan="1">
                            <para>05</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>2024/07/06</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>After Public Comment</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
    </chapter>

    <chapter>
        <title>To Do</title>
        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <tbody>
                    <tr>
                        <td colspan="1">
                            <para>1</para>
                        </td>
                        <td colspan="1">
                            <para>Register new Content Type for application/deflate - submitted as IANA #1367781 - awaiting response.</para>
                        </td>
                    </tr>
                    <tr>
                        <td colspan="1">
                            <para>2</para>
                        </td>
                        <td colspan="1">
                            <para>Rationalize use of "bit stream"vs. "byte stream".</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
    </chapter>

    <chapter>
        <title>Open Issues</title>
        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <tbody>
                    <tr/>
                </tbody>
            </informaltable>
        </section>
    </chapter>

    <chapter>
        <title>Closed Issues</title>
        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <tbody>
                    <tr>
                        <td colspan="1">
                            <para>1</para>
                        </td>
                        <td colspan="1">
                            <para>The scope is limited to Pixel Data (7FE0,0010) since that is the primary use case (esp. for single bit Segmentation objects) and is satisfied with minimal changes.</para>
                            <para>There is currently no Encapsulation mechanism defined for Float and Double Pixel Data, and extending support for that is beyond the scope of this Supplement.</para>
                            <para>There is no provision proposed for selectively encoding other Data Elements than those related to Pixel Data that may be large and desirable to selectively retrieve in a compressed form, whether they be bulk data (like ICC Profiles, LUTs or contour data), or sequences (like Per-Frame Function Group Sequences) and extending that for that is also beyond the scope of this Supplement.</para>
                        </td>
                    </tr>
                    <tr>
                        <td colspan="1">
                            <para>2</para>
                        </td>
                        <td colspan="1">
                            <para>Is the "deflate" value of Content-Encoding really the same as a deflated bit stream per <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc1951.html">RFC 1951</link> or is it actually using the zlib structure (defined in <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc1950.html">RFC 1950</link>) with the deflate compression algorithm require to be used?</para>
                            <para>Per the current <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc7230#section-4.2.2">RFC 7230 HTTP/1.1 Message Syntax and Encoding Section 4.2.2 Deflate Coding</link> '<emphasis role="italic">The "deflate" coding is a "zlib" data format [RFC1950] containing a "deflate" compressed data stream [RFC1951] that uses a combination of the Lempel-Ziv (LZ77) compression algorithm and Huffman coding. Note: Some non-conformant implementations send the "deflate" compressed data without the zlib wrapper.'</emphasis>. The clarifying note has apparently been added to the earlier description in <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc2616#section-3.5">RFC 2616 HTTP/1.1 Section 3.5 Content Encodings</link>.</para>
                            <para>The existing PS3.16 <xref linkend="para_b6edd5f2-5ef1-4c01-a2d6-92a913649c04" xrefstyle="template: note"/> for the existing whole-dataset transfer syntax is incorrect in this respect.</para>
                            <para>Though it could be amended to match the RFC requirement for the zlib container, as is done for the frame-level Content-Encoding, unfortunately the Content-Encoding applies to the entire multi-part stream, if the response is not a single part, and applies to the entire PS3.10 file and not just the dataset after the PS3.10 meta information, so it is not possible to simply apply a zlib container, so the offending note is clarified accordingly.</para>
                        </td>
                    </tr>
                    <tr>
                        <td colspan="1">
                            <para>3</para>
                        </td>
                        <td colspan="1">
                            <para>The frame deflate TS is added for Video to PS3.16 Table of Media Types and Transfer Syntax UIDs for Compressed Data in Bulkdata, since it has been added to the Transfer Syntax UIDs for application/dicom Media Types for Video, and these should be consistent.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td rowspan="1" colspan="1">
                            <para>1</para>
                        </td>
                        <td rowspan="1" colspan="1">
                            <para>There is not yet a standard Content Type for deflated (<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc1951.html">RFC 1951</link>) bit streams, so a request has been submitted to IANA for "application/deflate".</para>
                            <para>This is preferred over the alternative of specifying that gzip to be used as a container format, instead of deflate without a gzip; the existing "application/gzip" could be used but unfortunately gzip allows for other compression schemes than deflate to be used, which means the recipient may not have the appropriate decoder. This is the rationale used for the new media type application to IANA for deflate. See also <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc6713.html">RFC 6713</link> and <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc1952.html">RFC 1952</link> and <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.rfc-editor.org/rfc/rfc1950.html">RFC 1950</link>.</para>
                            <para>Using gzip rather than dflate would also be inconsistent with the existing (entire dataset) Deflated Explicit VR Little Endian Transfer Syntax.</para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
    </chapter>

    <chapter>
        <title>Scope and Field of Application</title>
        <para>This Supplement adds a new Transfer Syntax primarily for single bit segmentation encoding, which is otherwise not well supported.</para>
        <para>There is a need to be able to store and transfer encoded single frames (such as for DICOMweb) rather than the entire dataset for those applications where only selected frames of a multi-frame object are required (such as for selected tiles at selected resolutions for whole slide images that have been segmented, or multi-organ segmentations of large volumetric CT or MR datasets).</para>
        <para>Currently, the DICOM standard supports a means of single bit representation of binary segmentations with a Bits Stored and Bits Allocated of 1, and these can grow extremely large, especially when segmenting at the full resolution of the underlying image (e.g., for whole slide imaging). If compressed, they need to be mathematically reversibly (losslessly) compressed. The existing Deflate Transfer Syntax (algorithm used in zip and gzip) is reasonably effective, but applies to the entire data set (including the "metadata" and all the frames treated as a single stream).</para>
        <para>Frame-based pixel data compression schemes currently in the standard generally do not support single-bit, with the exception of RLE and J2K (CP 2301), neither of which achieves as high a compression ratio as Deflate does for segmentation data.</para>
        <para>Other alternative lossless compression codecs designed for single bit use (such as for fax using CCITT Group 4 (ITU-T T.6), JBIG, or JBIG2) were considered, which though they compress more effectively, were not considered widely enough supported to justify the complexity for this use case at this time. Other general purpose compressors do slightly better than Deflate, but again, not so much better that they justify their addition to the standard at this time, though they may be considered in future if other use cases justify them.</para>
    </chapter>


    <chapter label="PS3.2" status="1" xml:id="chapter_PS3.2">
        <title>DICOM PS3.2 - Conformance</title>
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.2 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <para><emphasis role="italic">Add new Transfer Syntax and Media Type to appropriate tables when finalized.</emphasis></para>
        
    </chapter>
    
    <chapter label="PS3.5" status="1" xml:id="chapter_PS3.5">
        <title>DICOM PS3.5 - Data Structures and Encoding</title>
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.5 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="2" status="1" xml:id="chapter_2">
            <title>Normative References</title>
            <bibliography>
                <title/>
                
        <biblioentry xml:id="biblio_RFC_1951">
            <abbrev>RFC1951</abbrev>
            <author>
                <orgname>IETF</orgname>
            </author>
            <title>DEFLATE Compressed Data Format Specification version 1.3</title>
            <bibliosource>
                <link xl:href="http://tools.ietf.org/html/rfc1951"/>
            </bibliosource>
        </biblioentry>
        
            </bibliography>
        </section>
        <section label="8" status="1" xml:id="chapter_8">
            <title>Encoding of Pixel, Overlay and Waveform Data</title>
            <para>...</para>
            <section label="8.2" status="2" xml:id="sect_8.2">
                <title>Native or Encapsulated Format Encoding</title>
                <para xml:id="para_f9b54410-31ad-4044-9be0-651dd86c84b3">Pixel data conveyed in the Pixel Data (7FE0,0010) may be sent either in a Native (uncompressed) Format or in an Encapsulated Format (e.g., compressed).</para>
                <para xml:id="para_1767d1f2-fcf4-46b9-a6fa-21b2e61e9b5d">...</para>

                <section label="8.2.n" status="3" xml:id="sect_8.2.n">
                    <title><emphasis role="underline">Deflated Image Frame Compression</emphasis></title>
                    <para><emphasis role="bold"><emphasis role="underline">DICOM provides a mechanism for supporting the use of Deflate compression of each individual image frame separately using the Encapsulated Format. Deflate is a byte oriented lossless compression scheme used with the Encapsulated Format.</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline"><xref linkend="sect_A.4.n" xrefstyle="select: label"/> defines a Transfer Syntax that uses the Deflate algorithm defined in <xref linkend="biblio_RFC_1951"/> to compress the pixel data of each image frame as a separate compressed bit stream.</emphasis></emphasis></para>
                    <note>
                        <orderedlist>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression is only applicable to pixel data conveyed in the Pixel Data (7FE0,0010) Data Element.</emphasis></emphasis></para>
                            </listitem>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">Though it uses the same compression scheme, the Deflated Image Frame Compression Transfer Syntax is distinct from the DICOM Deflated Little Endian Transfer Syntax (Explicit VR) Transfer Syntax defined in <xref linkend="sect_A.5" xrefstyle="select:label"/>, which compresses the entire Data Set as a single compressed bit stream.</emphasis></emphasis></para>
                            </listitem>
                        </orderedlist>
                    </note>
                    <para><emphasis role="bold"><emphasis role="underline">The use of the DICOM Encapsulated Format to support Deflated Image Frame Compression of Pixel Data requires that the Data Elements that are related to the Pixel Data encoding (e.g., Photometric Interpretation, Samples per Pixel, Planar Configuration, Bits Allocated, Bits Stored, High Bit, Pixel Representation, Rows, Columns, etc.) shall contain Values that are consistent with the compressed data.</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">Since the Deflate algorithm compresses byte streams regardless of their content and is not inherently specific to images, there are no restrictions on the values of Pixel Data Related Attributes.</emphasis></emphasis></para>
                    <note>
                        <para><emphasis role="bold"><emphasis role="underline">One application of Deflated Image Frame Compression is the lossless compression of bilevel (Bits Allocated (0028,0100) == 1) Segmentation images, but the mechanism is generic and not limited to any particular characteristics of the Pixel Data arrangement or values.</emphasis></emphasis></para>
                    </note>
                </section>
            </section>
        </section>
        
        <section label="10" status="1" xml:id="chapter_10">
            <title>Transfer Syntax</title>
            <para xml:id="para_a7227269-53ea-4926-a43e-fbd914dc4b43">...</para>
            <section label="10.n" status="2" xml:id="sect_10.n">
                <title>Transfer Syntax for Deflated Image Frame Compression</title>
                <para><emphasis role="bold"><emphasis role="underline">One Transfer Syntax is specified for Deflated Image Frame Compression. There is no default or baseline specified (other than as described in Section 10.1<!--<xref linkend="sect_10.1" xrefstyle="select: label"/>-->).</emphasis></emphasis></para>
                <orderedlist numeration="loweralpha">
                    <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">Since this is a lossless (reversible) Transfer Syntax, an Application Entity issues an A-ASSOCIATE request where any offered Abstract Syntaxes is associated in one or more Presentation Context(s) with Deflated Image Frame Compression Transfer Syntax, at least one of the Presentation Contexts that include this Abstract Syntax, shall include the DICOM Default Little Endian Transfer Syntax (uncompressed).</emphasis></emphasis></para>
                    </listitem>
                </orderedlist>
            </section>
            
        </section>

        <section label="A" status="1" xml:id="chapter_A">
            <title>Transfer Syntax Specifications (Normative)</title>
            <para>...</para>
            <section label="A.4" status="2" xml:id="sect_A.4">
      <title>Transfer Syntaxes For Encapsulation of Encoded Pixel Data</title>
      <para xml:id="para_637df8e8-3ec9-4054-accf-ac88bdd73f9d">These Transfer Syntaxes apply to the encoding of the entire DICOM Data Set, even though the image Pixel Data (7FE0,0010) portion of the DICOM Data Set is the only portion that is encoded by an encapsulated format.
        These Transfer Syntaxes shall only be used when Pixel Data (7FE0,0010) is present in the top level Data Set, and hence shall not be used when Float Pixel Data (7FE0,0008) or Double Float Pixel Data (7FE0,0009) are present.
        This implies that when a DICOM Message is being encoded according to an encapsulation Transfer Syntax the following requirements shall be met:</para>
      <orderedlist>
        <listitem>
          <para xml:id="para_c3892865-4597-489d-8746-df46215fe7d8">...</para>
        </listitem>
        <listitem>
          <para xml:id="para_4ac11983-1da9-45a8-903a-e690df481c85">...</para>
        </listitem>
        <listitem>
          <para xml:id="para_b5e2af39-f545-4a58-bd8a-faef00bfac1c">The encoding of the Data Elements of the Data Set shall be as follows according to their Value Representations:</para>
          <itemizedlist>
            <listitem>
              <para xml:id="para_2f69630f-745c-44ad-8013-d58d1e40abc4">...</para>
            </listitem>
            <listitem>
              <para xml:id="para_428d2f48-a706-43e0-bb3d-2bc775291d51">For the Value Representations OB, OL, OV and OW, the encoding shall meet the following specification depending on the Data Element Tag:</para>
              <itemizedlist>
                <listitem>
                  <para xml:id="para_d11882a9-2d96-4239-8809-1d7343f9f6f6">Pixel Data (7FE0,0010) may be encapsulated or native.</para>
                  <para xml:id="para_6666f793-ab61-4d3f-8686-142a1fd52846">It shall be encapsulated if present in the top-level Data Set (i.e., not nested within a Sequence Data Element).</para>
                  <note>
                    <para xml:id="para_fe1716f0-299b-425e-b3e6-33276fe7e59b">The distinction between defined Value Length (native) and undefined Value Length (encapsulated) is present so that the top level Data Set Pixel Data can be compressed (and hence encapsulated), but the Pixel Data within an Icon Image Sequence may or may not be compressed.</para>
                  </note>
                  <para xml:id="para_0775e8a7-768d-4792-830a-d498233a93ef">...</para>
                  <para xml:id="para_5755baf8-0054-4d4e-a46b-0d8c389d2cf5">If encapsulated, it has the Value Representation OB and is an octet-stream resulting from one of the encoding processes. ...</para>
                  <itemizedlist>
                    <listitem>
                      <para xml:id="para_97c429e3-6c06-424d-9bce-7c3148ba1324">...</para>
                    </listitem>
                    <listitem>
                      <para xml:id="para_24cbd6af-a8d0-4517-b73f-2fc42dae65ee">All items containing an encoded fragment shall be made of an even number of bytes greater or equal to two. The last fragment of a frame may be padded, if necessary, to meet the sequence item format requirements of the DICOM Standard.</para>
                      <note>
                        <orderedlist numeration="arabic">
                          <listitem>
                            <para xml:id="para_ae87ec68-d4d2-4819-8c38-1cf9cbe9c9c8">Any necessary padding may be added in the JPEG or JPEG-LS compressed data stream as per ISO 10918-1 and ISO 14495-1 such that the End of Image (EOI) marker ends on an even byte boundary, or may be appended after the EOI marker, depending on the implementation.</para>
                          </listitem>
                          <listitem>
                                                            <para xml:id="para_38bee48b-cd28-447b-be96-241c669b2359">ISO 10918-1 and ISO 14495-1 define the ability to add any number of padding bytes FFH before any marker (all of which also begin with FFH). It is strongly recommended that FFH padding bytes not be added before the Start of Image (SOI) marker.</para>
                                                        </listitem>
                                                        <listitem>
                                                            <para><emphasis role="bold"><emphasis role="underline">The end of a deflated bit stream will be indicated by the delimiter that will occur before any necessary padding with a single trailing NULL byte.</emphasis></emphasis></para>
                                                        </listitem>
                        </orderedlist>
                      </note>
                    </listitem>
                    <listitem>
                                                <para xml:id="para_468b80cc-d9c5-4d78-83d6-867548ed4e61">The first Item in the Sequence of Items before the encoded Pixel Data Stream shall be a Basic Offset Table item. ...</para>
                                            </listitem>
                                            <listitem>
                                                <para>...</para>
                                            </listitem>
                  </itemizedlist>
                </listitem>
                <listitem>
                  <para xml:id="para_972ccef9-9624-4ca5-8a18-5d7c3574a7c5">...</para>
                </listitem>
              </itemizedlist>
            </listitem>
          </itemizedlist>
        </listitem>
      </orderedlist>
      <para>...</para>
                
                <section label="A.4.n" status="3" xml:id="sect_A.4.n">
                    <title><emphasis role="underline">Deflated Image Frame Compression</emphasis></title>
                    <para><emphasis role="bold"><emphasis role="underline">The DICOM Transfer Syntax for Deflated Image Frame Compression encodes a stream of one or more frames of compressed pixel data as Encapsulated Fragments. This Transfer Syntax is identified by a UID of "1.2.840.10008.1.2.1.uu".</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">If the object allows multi-frame images in , then each frame shall be encoded separately.</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">Each frame shall be encoded​ in one and only one Fragment (see <xref linkend="sect_8.2" xrefstyle="select: label"/>).</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">The pixel data byte stream of each frame is separately compressed using the Deflate algorithm defined in <emphasis role="underline"><xref linkend="biblio_RFC_1951"/></emphasis>.</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">If the Deflate algorithm produces an odd number of bytes then a single trailing NULL byte shall be added after the last byte of the deflated bit stream for each frame.</emphasis></emphasis></para>
                </section>
                
            </section>
            <section label="A.5" status="2" xml:id="sect_A.5">
                <title>DICOM Deflated Little Endian Transfer Syntax (Explicit VR)</title>
                <para xml:id="para_7b1a24ad-0034-4dc1-9361-8a4beae65b11">This Transfer Syntax applies to the encoding of the entire DICOM Data Set.</para>
                <para xml:id="para_c0061611-6d14-4a0e-a67e-e53581003d9a">The entire Data Set is first encoded according to the rules specified in Section A.2<!--<xref linkend="sect_A.2" xrefstyle="select: label"/>-->.</para>
                <para xml:id="para_60020ba1-725e-4c20-bebd-5206f16dbcb7">The entire byte stream is then compressed using the <emphasis role="bold"><emphasis role="strikethrough">"</emphasis></emphasis>Deflate<emphasis role="bold"><emphasis role="strikethrough">"</emphasis></emphasis> algorithm defined in <emphasis role="bold"><emphasis role="strikethrough">Internet RFC 1951</emphasis><emphasis role="underline"><xref linkend="biblio_RFC_1951"/></emphasis></emphasis>.</para>
                <note>
                    <para><emphasis role="bold"><emphasis role="underline">Though it uses the same compression scheme, the DICOM Deflated Little Endian Transfer Syntax (Explicit VR) Transfer Syntax is distinct from the Deflated Image Frame Compression Transfer Syntax defined in <xref linkend="sect_A.4.n" xrefstyle="select:label"/>, which compresses the pixel data of each image frame as a separate compressed bit stream and uses the Encapsulated Format encoding.</emphasis></emphasis></para>
                </note>
                <para xml:id="para_66fed7f1-4f6c-4b6f-88fd-a3db95e03916">If the <emphasis role="bold"><emphasis role="strikethrough">d</emphasis><emphasis role="underline">D</emphasis></emphasis>eflate algorithm produces an odd number of bytes then a single trailing NULL byte shall be added after the last byte of the deflated bit stream.</para>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_2c450bfd-49ab-4db9-9bc7-9b72dd52859d">The Pixel Data in Pixel Data (7FE0,0010), Float Pixel Data (7FE0,0008) or Double Float Pixel Data (7FE0,0009) is not handled in any special manner. The pixel data is first encoded as sequential uncompressed frames without encapsulation, and then is handled as part of the byte stream fed to the "deflate" compressor in the same manner as the Value Field of any other Data Element.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_4601a1d2-e004-43f4-a04c-4c7de6e616b7">This Transfer Syntax is particularly useful for compression of objects without pixel data, such as structured reports. It is not particularly effective at image compression, since any benefit obtained from compressing the non-pixel data is offset by less effective compression of the much larger pixel data.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_17f16857-2181-4d32-9562-9489e2735fc1">A freely available reference implementation of the "deflate" compressor may be found in the zlib package, which may be downloaded from <link xl:href="http://www.zlib.net/"/>.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_c57d3f48-11e5-4b70-ae0e-913a8afcbfef">Although the encoded stream may be padded by a trailing NULL byte, the end of the deflated bit stream will be indicated by the delimiter that will occur before the padding.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_388e73ba-5381-4d1f-a295-8fc80abd79b9">In order to facilitate interoperability of implementations conforming to the DICOM Standard that elect to use this Transfer Syntax, the following policy is specified:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_6c4b9d15-b230-4bee-8543-001de8d2b954">Any implementation that has elected to support the Deflated Explicit VR Little Endian Transfer Syntax for any Abstract Syntax, shall also support the Explicit VR Little Endian Transfer for that Abstract Syntax.</para>
                    </listitem>
                </itemizedlist>
                <note>
                    <orderedlist numeration="arabic">
                        <listitem>
                            <para xml:id="para_8e52de53-8fe1-476e-a825-7bd000722d5f">This requirement to support the (uncompressed) Explicit VR Little Endian Transfer Syntax is in order to ensure full-fidelity exchange of VR information in the case that the Association Acceptor does not support the Deflated Explicit VR Little Endian Transfer Syntax. The requirement specified in Section 10.1<!--<xref linkend="sect_10.1" xrefstyle="select: label"/>--> of this Part, that the Default Implicit VR Little Endian Transfer Syntax be supported by all implementations except those that only have access to lossy compressed pixel data, is not waived. In other words, an implementation must support all three Transfer Syntaxes.</para>
                        </listitem>
                        <listitem>
                            <para xml:id="para_cc946581-9067-494a-8f18-a84588d2b88e">There are no such "baseline" requirements on media, since such requirements are at the discretion of the Media Application Profile. Furthermore, sufficient object "management" information should be present in the DICOMDIR even if an individual application cannot decompress an instance encoded with the deflated Transfer Syntax.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_1c96a663-1315-45ab-9b63-1a6c1873a135">This DICOM Deflated Explicit VR Little Endian Transfer Syntax shall be identified by a UID of Value "1.2.840.10008.1.2.1.99".</para>
            </section>
        </section>
        
    </chapter>

    
    <chapter label="PS3.6" status="1" xml:id="chapter_PS3.6">
        <title>DICOM PS3.6 - Data Dictionary</title>
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.6 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="A" status="1" xml:id="chapter_A">
            <title>Registry of DICOM Unique Identifiers (UIDs) (Normative)</title>
            
            <table frame="box" label="A-1" rules="all" xml:id="table_A-1">
                <caption>UID Values</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89103697-fd54-4c3f-abbe-5655ae35308b">
                                <emphasis role="bold">UID Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb5b6b8a-9aec-44f2-8cdc-800a7cd327b7">
                                <emphasis role="bold">UID Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_013510c8-4f44-4131-9319-6e72c777418c">
                                <emphasis role="bold">UID ​Keyword</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08eb5599-7f50-4d17-bd10-6617063c6e31">
                                <emphasis role="bold">UID Type</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42e221e9-efb2-49d7-8712-69266c9bc2d4">
                                <emphasis role="bold">Part</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c30480f1-f961-4d6d-9f8a-c3ebc3c35684">1.2.840.10008.1.2.​1.​99</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8a634539-5388-47d4-a5f1-7732d1583383">Deflated Explicit VR Little Endian</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e8e25b31-dbcf-4f4a-9daf-25710a6dbd66">Deflated​Explicit​VR​Little​Endian</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c9daa363-f982-4b0f-8abe-f0a7c99b6621">Transfer Syntax</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2eb531e-95da-4869-b5d5-0d265b41137b">
                                <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>
                            </para>
                        </td>
                    </tr><tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.​1.​uu</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Deflated​Image​Frame​Compression</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Transfer Syntax</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
    
    </chapter>
    
    <chapter label="PS3.18" status="1" xml:id="chapter_PS3.18">
        <title>DICOM PS3.18 - Web Services</title>
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.18 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="2" status="1" xml:id="chapter_2">
            <title>Normative References</title>
            <bibliography>
                <bibliodiv label="2.1" status="2" xml:id="sect_2.1">
                    <title>International Organization for Standardization (ISO) and International Electrotechnical Commission (IEC)</title>
                    <biblioentry xml:id="biblio_ISOIEC10918-1">
                        <abbrev>ISO/IEC 10918-1</abbrev>
                        <author>
                            <orgname>ISO/IEC</orgname>
                        </author>
                        <date>1994</date>
                        <title>JPEG Standard for digital compression and encoding of continuous-tone still images. Part 1 - Requirements and implementation guidelines</title>
                    </biblioentry>
                </bibliodiv>
                <bibliodiv label="2.2" status="2" xml:id="sect_2.2">
                    <title>Internet Engineering Task Force (IETF) and Internet Assigned Names Authority (IANA)</title>
                    <biblioentry xml:id="biblio_RFC_7230">
                        <abbrev>RFC7230</abbrev>
                        <author>
                            <orgname>IETF</orgname>
                        </author>
                        <date>June 2014</date>
                        <title>Hypertext Transfer Protocol (HTTP/1.1): Message Syntax and Routing</title>
                        <bibliosource>
                            <link xl:href="http://tools.ietf.org/html/rfc7230"/>
                        </bibliosource>
                    </biblioentry>
                </bibliodiv>
            </bibliography>
        </section>
        
        <section label="8.7.3.1" status="4" xml:id="sect_8.7.3.1">
                    <title>Instance Media Types</title>
                    <para xml:id="para_47a6547d-80ef-453a-82e6-2adc550f82db">The application/dicom media type specifies a representation of Instances encoded in the DICOM File Format specified in <olink targetdoc="PS3.10" targetptr="chapter_7" xrefstyle="template:Section %n “%t” in PS3.10"/>.</para>
                    <para xml:id="para_500a6fa6-1823-4929-905f-a9fdc2ff988c">...</para>
                    <table frame="box" label="8.7.3-2" rules="all" xml:id="table_8.7.3-2">
                        <caption>Transfer Syntax UIDs for application/dicom Media Types</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7ba28fa3-4cb7-464c-afbe-0b4693771288">Category</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_95d35ffd-d5e7-43b2-a0bd-1a8d81e2c085">Transfer Syntax UID</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4f36c4f7-667f-49cc-af7f-7d3981022110">Transfer Syntax Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a9174cee-b820-4d78-8aa0-4de7f0f12936">Optionality</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="4">
                            <para xml:id="para_81301422-2f37-4af8-a162-e0510c654a0f">Single Frame Image</para>
                        </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_262b6fc9-089e-4c9b-b4ce-82106b83879b">1.2.840.10008.1.2.1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ebe50c83-1e02-4bd1-a897-c14b8d9dce17">Explicit VR Little Endian</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a5cc9add-6e4f-4a41-8eff-d58dde41ca80">D</para>
                                </td>
                            </tr>
                    <tr>
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.1.uu</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">O</emphasis></emphasis></para>
                        </td>
                    </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_565fcd1f-97b4-4d79-9a41-ff6143b65616">1.2.840.10008.1.2.4.70</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_02ec73e5-2c33-4b1f-aee6-daad26c73ab6">JPEG Lossless, Non-Hierarchical, First-Order Prediction(Process 14 [Selection Value 1]): Default Transfer Syntax for Lossless JPEG Image Compression</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_be656b08-d398-4b49-9c1f-6224305daafe">O</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fbc9e71-a805-4f35-a4bf-52d6acb573a8">...</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99dedbab-077c-4149-8683-4d6d745bdbca"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2b0424e7-d8a7-454b-8816-288b1a9d5e08"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="4">
                            <para xml:id="para_0e238099-831d-4651-a463-db14a6e67cf6">Multi-frame Image</para>
                        </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0941aca4-dba5-42cc-8ab3-77ecfef272e5">1.2.840.10008.1.2.1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb397a36-09e9-47a0-b149-dd686be9b429">Explicit VR Little Endian</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2ef08400-9d37-4ced-8c34-3bda87eadf87">D</para>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.1.uu</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">O</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_76ab2c44-9160-4b50-94f4-bfb275aa4f3b">1.2.840.10008.1.2.4.90</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3c4f5a70-45b8-4cc0-9af8-386f519c44b1">JPEG 2000 Image Compression (Lossless Only)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3afca3a0-937a-4da8-9726-24cddcfa6b38">O</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bf0b6949-1956-4ce9-bc96-8e1874f04a37">...</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f7a015ae-0e37-4b0f-a031-c132953246be"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_988ce086-9923-4481-949a-9bd93d8b1dee"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="4">
                            <para xml:id="para_35596624-6724-4346-9666-43dea9252dcd">Video</para>
                        </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dba2dd58-c749-4f33-a94c-f5325c9f721a">1.2.840.10008.1.2.1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f383fc94-e036-4a12-942e-b3cca6fb5d63">Explicit VR Little Endian</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_91f03550-a63f-46d7-8804-537af132ad23">D</para>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.1.uu</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">O</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2789b547-5be0-4e6e-9a51-21a53b2273ef">1.2.840.10008.1.2.4.100</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f2a2f8a7-629d-492b-b30d-e267a20aabf0">MPEG2 Main Profile @ Main Level</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_fa80d456-c11e-4927-9ef4-2ef52fdc80d8">O</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ef46357c-7df6-447b-a9b0-38d004376cc3">...</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6505b6b3-6324-41e5-887c-cf090a3f32f1"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_36345536-da66-4bb3-b58f-dbfb18d0949a"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_255fe5b2-d3ac-42d7-8f10-b24d4be03f38">Text</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7328dfc5-ff13-4588-8329-a50a815ce651">1.2.840.10008.1.2.1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cdb0448e-8194-4a55-93f0-3862bc989e95">Explicit VR Little Endian</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8519a66a-613d-4037-96b4-355b6fb00985">D</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c204a964-0626-4a2f-936d-cf0592ce61c8">Other</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_26013b21-b5e4-4ba7-89a8-119696bc22f3">1.2.840.10008.1.2.1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6ead09c6-8278-461a-95a8-55c21a33c43d">Explicit VR Little Endian</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5ea162c4-a84f-47e3-a2e7-039cd3fda28f">D</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <note>
                        <para xml:id="para_95ecc4f8-d814-45ec-92e8-fce715062074">The Transfer Syntaxes used in a DICOM-RTV Metadata Flow are not included, since they are not used to produce a representation of an Instance encoded in the DICOM File Format.</para>
                    </note>
                </section>
        
        <section label="8.7.3.3.2" status="5" xml:id="sect_8.7.3.3.2">
                        <title>Compressed Bulkdata Media Types</title>
                        <para xml:id="para_4a815773-da08-472a-bead-e64f98d8ea73">Compressed Bulkdata contains only the compressed octet stream without the fragment delimiters.</para>
                        <para xml:id="para_2eb98375-ba81-4176-a87a-ddf67c0e7247">...</para>
                        <table frame="box" label="8.7.3-5" rules="all" xml:id="table_8.7.3-5">
                            <caption>Media Types and Transfer Syntax UIDs for Compressed Data in Bulkdata</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_5fd9cca7-3acb-4293-b95f-4caa231206ff">Resource Category</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_7994e4ec-de50-4bac-a223-7923d706906a">Media Type</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_35f736eb-8025-4acb-8cdd-c5b3e2c24571">Transfer Syntax UID</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_2433f27b-6a17-423c-80bc-e01ae8f5689f">Transfer Syntax Name</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_559f0040-7781-4fd1-86dc-f6c4dbdbaa6f">Optionality</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="15">
                            <para xml:id="para_37816794-0fa7-4ae4-99cd-487c93d22587">Single Frame Image</para>
                        </td>
                                    <td align="left" colspan="1" rowspan="4">
                                        <para xml:id="para_73bae70b-4bb0-4bfe-9f0a-4a52c4787f1b">image/jpeg</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f149b419-0058-4d54-a803-3897e2b408c8">1.2.840.10008.1.2.4.70</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_729afcb1-9049-4642-900f-d4ebea6fabe7">JPEG Lossless, Non-Hierarchical, First-Order Prediction(Process 14 [Selection Value 1]) :Default Transfer Syntax for Lossless JPEG Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_4a17b11a-d87a-4128-bd63-3621417695b4">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_9f8f9015-6cdc-425b-ad40-ff55dce3a40d">1.2.840.10008.1.2.4.50</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_9ed8aa32-51c8-446f-893e-681828bcdf0b">JPEG Baseline (Process 1) :Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_f7b6ee7f-946f-4739-a0df-7e2b06c74daa">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_05282080-91b0-4f24-b1cc-22440cd18a0f">1.2.840.10008.1.2.4.51</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7b4a27fb-a540-4c0c-8549-00f9240f0c9e">JPEG Extended (Process 2 &amp; 4) :Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_fcc1cbe3-b2fa-47c9-816f-4b9f77d7c6fd">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6cd17789-e8c1-4712-9b78-1c53dab8186f">1.2.840.10008.1.2.4.57</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e7e00c96-4296-4917-9c02-ad7e77b95ea6">JPEG Lossless, Non-Hierarchical (Process 14)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_21b8f4b8-bc1e-488e-96f7-cfb2963dd048">O</para>
                                    </td>
                                </tr>
                    <tr>
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">application/vnd.dicom-deflate</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.1.uu</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                        </td>
                    </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_929b4f80-7c5b-4ae0-bceb-a2acdff917a6">image/dicom-rle</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_430320f8-8a09-47f0-adf3-a654b91b49d9">1.2.840.10008.1.2.5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_17f54b07-a63f-441c-a7cf-003307f5b7a5">RLE Lossless</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_8437e9ee-c93f-49bd-937a-356874d74a6d">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                                        <para xml:id="para_79c26c30-e953-41ad-a21e-3c5f10795dcc">image/jls</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d5db8f5c-7a8d-4a78-915a-d12d6859b7ea">1.2.840.10008.1.2.4.80</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_97c5a63b-a09f-4f00-a3ec-cb10cc4870e4">JPEG-LS Lossless Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_9270505b-49be-4481-b562-57a9bacb9143">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_555cad95-2dca-4d42-a736-08f178a72a65">1.2.840.10008.1.2.4.81</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2d11a04f-04df-4a12-8703-e5f5c9557290">JPEG-LS Lossy (Near-Lossless) Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_679fa971-4336-4d55-abb6-637c3da8453e">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                                        <para xml:id="para_75ad33e4-6058-42c5-86c0-1a56036d8c18">image/jp2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8b5ca864-1d0e-4508-a5bb-30840fa53175">1.2.840.10008.1.2.4.90</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_153b6fd3-6f78-4fe8-a41e-cfadc6c588b1">JPEG 2000 Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_b531fdc4-a42e-4b03-8f1e-020b9a2b8dbf">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8210264d-270f-49b6-bd8d-940c926422d5">1.2.840.10008.1.2.4.91</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2244e4d6-1c28-40f4-857b-d6df37df37f5">JPEG 2000 Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_022bacd5-9bb8-41b3-b56e-13d1fd4bc86a">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                                        <para xml:id="para_66bff052-8ae7-460c-8e67-14c85c5b6638">image/jpx</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b478a4d0-4205-44d7-83e4-6210c326831a">1.2.840.10008.1.2.4.92</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4bb5f574-c051-4fde-ad82-b50aba4cf672">JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_1be6e09a-7650-4c2f-9640-ac36812b0c40">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b910e78e-9ef1-41e8-8535-62809d5f9231">1.2.840.10008.1.2.4.93</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1fc57e87-8b60-4b9a-93a2-bb6adefae179">JPEG 2000 Part 2 Multi-component Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_2f37b5e6-a7cc-406d-b6f2-732b28cca933">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="3">
                                        <para xml:id="para_410691e0-ca5b-47c3-8ad2-43aacbb7ef00">image/jphc</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a2ef5893-b80d-4f88-95a2-377d46967792">1.2.840.10008.1.2.4.201</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4c3aad18-fd73-4168-850d-7222cd5e4499">High-Throughput JPEG 2000 Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_a6e8b8fd-2068-415b-8602-6e8c5f1284ad">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d83ac38b-07d2-46ba-9ea1-d5cff6e8ccc0">1.2.840.10008.1.2.4.202</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c76fe476-e8ec-48a0-a196-c945f6a50196">High-Throughput JPEG 2000 with RPCL Options Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_5241adca-7925-4454-bcd7-6e24583338f0">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f4aaddf7-d89e-4172-abea-9407815ebb63">1.2.840.10008.1.2.4.203</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_86b6eae4-a9dc-4a4f-9c1a-90f2c11f84d1">High-Throughput JPEG 2000 Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_627b9e3f-5143-45c8-9e13-72464ac396a0">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="15">
                            <para xml:id="para_58fe479a-19a3-499c-97c4-99f37c8b6d93">Multi-frame Image</para>
                        </td>
                                    <td align="left" colspan="1" rowspan="4">
                                        <para xml:id="para_adc35b66-eadd-4436-855c-aab9f508f98c">image/jpeg</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4bae6f21-03f0-49f9-b7ba-e473f32ba57f">1.2.840.10008.1.2.4.70</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d779645d-e772-4438-8a2d-2b4fc3904419">JPEG Lossless, Non-Hierarchical, First-Order Prediction(Process 14 [Selection Value 1]) :Default Transfer Syntax for Lossless JPEG Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_b56d9b67-1a60-42ca-8f5c-bffbd75ec279">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e404ecf2-a0b9-45fc-b674-e3b07c02b096">1.2.840.10008.1.2.4.50</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_feeb029c-1851-4046-9033-fb932708f9d2">JPEG Baseline (Process 1) :Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_77cf0b93-9466-407b-ba80-ceb1a3cd3843">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_379ce70d-4354-42d7-82e7-b414effb960b">1.2.840.10008.1.2.4.51</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_09d5e444-72dd-4484-9fad-71f85c05c493">JPEG Extended (Process 2 &amp; 4) :Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_ae944277-ac66-4adc-9562-be790459a0f1">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c8e3254f-145f-47ef-af4a-38ae8ac6970c">1.2.840.10008.1.2.4.57</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4d3374a3-ce08-436e-b224-73f84aaccf3e">JPEG Lossless, Non-Hierarchical (Process 14)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_c8000700-e326-48c9-bf2c-3bec71a6be52">O</para>
                                    </td>
                                </tr>
                                <tr>
                                    <td align="left" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">application/vnd.dicom-deflate</emphasis></emphasis></para>
                                    </td>
                                    <td align="left" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.1.uu</emphasis></emphasis></para>
                                    </td>
                                    <td align="left" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                                    </td>
                                    <td align="center" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b2ea5284-ef22-4286-a6ee-e26eea1242c6">image/dicom-rle</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1932b145-3462-485b-b74c-a90cbfb02683">1.2.840.10008.1.2.5</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ce9181a5-4c6c-4a25-873f-27b451f5be95">RLE Lossless</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_a7def47b-4933-4b79-9693-037d39d93e81">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                                        <para xml:id="para_2bd0959b-7852-427c-92a7-5e78431f8460">image/jls</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_37209b09-8bd8-409f-8e32-7a36612f4100">1.2.840.10008.1.2.4.80</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4056b470-886b-470b-9de2-9b6770b1631b">JPEG-LS Lossless Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_24696ad4-b0eb-452e-8df4-0171665d8d53">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_93472667-e928-40c4-bf0a-aba2bd15e788">1.2.840.10008.1.2.4.81</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_90fe69e3-3e1b-4984-8375-91c2c7724e48">JPEG-LS Lossy (Near-Lossless) Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_5bbf20e2-4998-4ca5-974a-f57d423b1beb">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                                        <para xml:id="para_53de1bb7-a5b7-42ca-8dce-4f2dcf9f0ccb">image/jp2</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e89dd310-c546-48ff-8489-e1ac8907d995">1.2.840.10008.1.2.4.90</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f777e5c2-9cef-4107-bd7a-95aaa35a4302">JPEG 2000 Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_9adc9a5c-49fb-4292-aba4-e8d80db1485d">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_bc1995ec-3d3b-4acb-8ee4-7a50e4e7e8ec">1.2.840.10008.1.2.4.91</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3e5b7f0d-4ba8-4b5e-8ccb-88c6bd862480">JPEG 2000 Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_77f6d3ae-3893-4f7f-9445-1d1c8e1621fa">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                                        <para xml:id="para_d99770d4-0040-42f5-a032-492de2236a51">image/jpx</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b0f0ccd5-9e7f-4ab3-acb7-97b649df46fc">1.2.840.10008.1.2.4.92</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4b849a1e-93e0-4b2f-b5e1-dd3eafc57178">JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_e4740c68-a1fb-4553-9e2d-2559ef37bc5f">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e3cab1d8-4962-4217-9cfd-69101205e2ac">1.2.840.10008.1.2.4.93</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_4195388a-4d09-4f7c-9682-5c7b4a461f54">JPEG 2000 Part 2 Multi-component Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_3994de5f-c94c-44ff-8d58-9db46c8ed6e9">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="3">
                                        <para xml:id="para_d60dfda3-3ee8-4f01-935f-5362cc072b15">image/jphc</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_37129abb-0b7b-471a-a1ab-69956bc0598c">1.2.840.10008.1.2.4.201</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c71bc359-3b7d-4456-87d6-57ef922ad999">High-Throughput JPEG 2000 Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_67c8d9b4-23b3-4e92-9bf0-ae1f71bc1a54">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f56476f7-86d0-478b-9bf6-183819fdb893">1.2.840.10008.1.2.4.202</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_bcc9073a-8643-416f-b8a6-a39c433014f7">High-Throughput JPEG 2000 with RPCL Options Image Compression (Lossless Only)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_59932f8f-bb95-446f-ae7c-4f8e3f330824">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_01231395-4439-47da-90d2-b12de036fbb5">1.2.840.10008.1.2.4.203</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_861eddd9-a7da-48dd-bfe3-1ac2000b9090">High-Throughput JPEG 2000 Image Compression</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_99392066-ffe9-4423-8d0a-0a2065c80f17">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="17">
                            <para xml:id="para_d21bae35-e651-455e-9e53-d22810cfc834">Video</para>
                        </td>
                                    <td align="left" colspan="1" rowspan="4">
                                        <para xml:id="para_e6695c7b-e1cc-4c44-b542-972386186b11">video/mpeg</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_cfd64a72-e8ec-4305-80be-797fe23b9c6a">1.2.840.10008.1.2.4.100</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_bb5c95dc-b3a7-47fb-8717-aacdf54e4d22">MPEG2 Main Profile @ Main Level</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_197d343d-2acb-40ae-b2f9-2978ecfa49f6">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                   <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7a828493-99b7-4566-bd2c-c1bb85ad4458">1.2.840.10008.1.2.4.100.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_003f876d-8eb7-4ca4-8def-1db0fd04f1e4">Fragmentable MPEG2 Main Profile @ Main Level</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_5502863d-1151-46d2-bb89-306c13a9e54b">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_15185835-33be-4043-8e42-9e3a34359846">1.2.840.10008.1.2.4.101</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8113dbe8-0901-4af2-a66d-affc66b4ea90">MPEG2 Main Profile @ High Level</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_c572abd6-3567-454b-9502-9d6442fafc17">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_62eae9b7-dce3-4591-bc3b-59de63b8877d">1.2.840.10008.1.2.4.101.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_e669dbd1-c3c9-470e-a92b-1e252e2710c8">Fragmentable MPEG2 Main Profile @ High Level</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_22d8a63c-255f-428b-ba92-abe860c4eb64">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="10">
                                        <para xml:id="para_1de32ec0-f9f7-4de7-aeab-b683397a521d">video/mp4</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5c984017-0366-4ee0-a973-97da7bf6711a">1.2.840.10008.1.2.4.102</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_cab56a01-70c4-434b-9237-8659da9404b6">MPEG-4 AVC/H.264 High Profile / Level 4.1</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_0bf15820-49e5-4a08-b695-9c3db0c7071c">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_fb1438ea-4096-4f03-9c41-6ec87e6355b6">1.2.840.10008.1.2.4.102.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_82c71c72-28a2-4b83-8fdf-1b6aaea1adc8">Fragmentable MPEG-4 AVC/H.264 High Profile / Level 4.1</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_2d85c0c7-ab39-4b2f-bd21-458a96d7aadb">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_26e68688-a821-4ccb-a8a5-eae15722b2bc">1.2.840.10008.1.2.4.103</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6a957a7c-5eab-4dce-9a10-5ba763dd34bc">MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_38997403-c863-488c-a591-9fbffa66261f">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_96b4526e-4832-4df7-bcfc-d92925a38b93">1.2.840.10008.1.2.4.103.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_456fa15f-0db3-41e2-a325-47f3710c91ae">Fragmentable MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_6a5e3689-3cb7-42fd-bfa7-f12d1027ee22">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_debd94db-0da1-4a3f-88bd-5acef3a6bf51">1.2.840.10008.1.2.4.104</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_64c8e62b-b96c-4a1a-b1ef-5c7066d6428b">MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_6d945cae-784f-49ef-8e99-2e4d4e91c497">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5ca4f791-1edb-4b30-bd3c-b63948fe9b36">1.2.840.10008.1.2.4.104.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6a76b5b1-3277-4bdf-88c6-3983d38b3796">Fragmentable MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_c3b794ad-99b1-4e4d-bc29-7ce1cec39b3f">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_907ca0c7-923a-457d-a198-b09d324ede6b">1.2.840.10008.1.2.4.105</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_c6f0582d-92ec-4fd8-bc72-06bee5fc4dcc">MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_016af1d9-7b6b-4778-9d23-dd82a547fd05">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a720df0e-c418-48cf-b8fe-f0a9860ba65e">1.2.840.10008.1.2.4.105.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_88a6b14c-34ff-4003-b74a-c80a1be24277">Fragmentable MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_3e45a6b2-3570-46ab-8b58-d955a155edf8">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2ee3e897-394f-41a1-9db7-808e711c18bf">1.2.840.10008.1.2.4.106</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_eae7fa55-46ae-4ea1-b857-d9cb34d320b2">MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_16b8183e-17fb-4b2e-9cd9-90aed9d1d817">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_df407c8f-67d0-4fc2-b161-1b4013bed3fa">1.2.840.10008.1.2.4.106.1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_36dd177b-dab1-4435-8607-6558d4a12f83">Fragmentable MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_59a70cc3-966b-437e-92e6-1d6bde213724">O</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="2">
                            <para xml:id="para_6dc05685-e11c-49cb-b281-1876f1599f52">video/H265</para>
                        </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_6ff17c8c-bf7d-4365-8318-c7173cb189b2">1.2.840.10008.1.2.4.107</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_8a889180-8dbd-497d-910a-04fb46ddaae8">HEVC/H.265 Main Profile / Level 5.1</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_5cec4533-36fe-4d9a-a80f-d88aff387911">D</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_82c9a921-821b-49b8-85d7-daf492dd759e">1.2.840.10008.1.2.4.108</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_158d3a67-f934-48b9-a1e3-66e93527dae1">HEVC/H.265 Main 10 Profile / Level 5.1</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_f00420f2-cc4a-4538-b570-6b4dca5c1bf6">O</para>
                                    </td>
                                </tr>
                                <tr>
                                    <td align="left" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">application/vnd.dicom-deflate</emphasis></emphasis></para>
                                    </td>
                                    <td align="left" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">1.2.840.10008.1.2.1.uu</emphasis></emphasis></para>
                                    </td>
                                    <td align="left" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">Deflated Image Frame Compression</emphasis></emphasis></para>
                                    </td>
                                    <td align="center" colspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">D</emphasis></emphasis></para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_57f5457e-edce-4c67-b27b-6b4be391c29c">Text</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1"/>
                                    <td align="left" colspan="2" rowspan="1">
                                        <para xml:id="para_4853f230-c07c-472d-a7aa-a376a18617b9">N/A (no defined compression transfer syntaxes for Text)</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1"/>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d2d5e4d2-b7f0-4ef4-9fdd-f0d372784002">Other</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1"/>
                                    <td align="left" colspan="2" rowspan="1">
                                        <para xml:id="para_9dca728b-0e51-4f58-93e8-55e3efbcfe20">N/A (no defined compression transfer syntaxes for Other)</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1"/>
                                </tr>
                            </tbody>
                        </table>
                        <para xml:id="para_9799cecd-066e-438d-b50e-bd9b6f8d6f05">...</para>
                        <note>
                            <orderedlist>
                                <listitem>
                                    <para xml:id="para_b6edd5f2-5ef1-4c01-a2d6-92a913649c04">The resource on the origin server may have been encoded in the Deflated Explicit VR Little Endian (1.2.840.10008.1.2.1.99) Transfer Syntax.
                                        If so, the origin server may inflate it, and then convert it into an Acceptable Transfer Syntax. A<emphasis role="bold"><emphasis role="strikethrough">lternatively, if the user agent allowed a</emphasis></emphasis> Content-Encoding header field of 'deflate'<emphasis role="bold"><emphasis role="strikethrough">, then</emphasis><emphasis role="underline"> cannot be used to transfer</emphasis></emphasis> the deflated bytes<emphasis role="bold"><emphasis role="strikethrough"> may be transferred</emphasis></emphasis> unaltered<emphasis role="bold"><emphasis role="strikethrough">, but the Transfer Syntax parameter in the response should be the Explicit VR Little Endian Transfer Syntax</emphasis><emphasis role="underline"> since the required <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/> File Meta
                                    Information is not included in the deflated bytes, and the Content-Encoding applies to the entire multipart stream, not each part within it individually</emphasis></emphasis>.</para>
                                    <para><emphasis role="bold"><emphasis role="underline">The resource on the origin server may have been encoded in the Deflated Image Frame Compression (1.2.840.10008.1.2.1.uu) Transfer Syntax.
                                        If so, the origin server may return the compressed bit stream if it is an Acceptable Transfer Syntax, or the origin server may inflate it, and then convert it into an Acceptable Transfer Syntax. Alternatively, if the user agent allowed a Content-Encoding header field of 'deflate', then the deflated bytes may be transferred after adding a zlib container per <xref linkend="biblio_RFC_7230"/> Section 4.2.2, but the Transfer Syntax parameter in the response should be the Explicit VR Little Endian Transfer Syntax.</emphasis></emphasis></para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_1dd25561-647c-4831-8daa-4d287120d428">...</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </section>
    </chapter>
</book>