<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2410</title>
    <subtitle>Formally define Attribute Value</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/22</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier</para><para><link
                    xl:href="mailto:dicom@jriesmeier.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/03/04</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2410</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Formally define Attribute Value</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3 2024e</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The term value is used throughout PS3.3 without definition. Define it, related it to the PS3.5 Data Element Value, and capitalize appropriately when used.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis>
                        for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="3" status="1" xml:id="chapter_3">
            <title>Definitions</title>
            <glossary>
                <glossdiv label="3.3" status="2" xml:id="sect_3.3">
                    <title>DICOM Introduction and Overview Definitions</title>
                    <para xml:id="para_557ab9f6-e31b-47f5-a4dc-b245a6dce24c">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.1" targetptr="PS3.1" xrefstyle="select: labelnumber"/>:</para>
                    <glossentry xml:id="glossentry_Attribute" xreflabel="Attribute">
                        <glossterm>Attribute</glossterm>
                        <glossdef>
                            <para xml:id="para_ba24e26a-8a3f-4b79-b2a5-b108bb0f2220">
                                <olink targetdoc="PS3.1" targetptr="glossentry_Attribute" xrefstyle="template:See %t in %o"/>.</para>
                        </glossdef>
                    </glossentry>
                </glossdiv>
                <glossdiv label="3.5" status="2" xml:id="sect_3.5">
                    <title>DICOM Data Structures and Encoding</title>
                    <para xml:id="para_1b4e328a-0193-4636-88c9-079655a44d01">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.5" targetptr="PS3.5" xrefstyle="select: labelnumber"/>:</para>
                    <glossentry xml:id="glossentry_DataElement" xreflabel="Data Element">
                        <glossterm>Data Element</glossterm>
                        <glossdef>
                            <para xml:id="para_c4150cce-8779-42dc-9e17-d1d9f54aaf94">
                                <olink targetdoc="PS3.5" targetptr="glossentry_DataElement" xrefstyle="template:See %t in %o"/>.</para>
                        </glossdef>
                    </glossentry>
                    <glossentry xml:id="glossentry_Value" xreflabel="Value">
                        <glossterm><emphasis role="bold"><emphasis role="underline">Value</emphasis></emphasis></glossterm>
                        <glossdef>
                            <para><emphasis role="bold"><emphasis role="underline">See Value in PS3.5</emphasis></emphasis><!--<olink targetdoc="PS3.5" targetptr="glossentry_Value" xrefstyle="template:See %t in %o"/>-->.</para>
                        </glossdef>
                    </glossentry>
                </glossdiv>
                <glossdiv label="3.8" status="2" xml:id="sect_3.8">
                    <title>DICOM Information Object</title>
                    <glossentry xml:id="glossentry_AttributeTag" xreflabel="Attribute Tag">
                        <glossterm>Attribute Tag</glossterm>
                        <glossdef>
                            <para xml:id="para_01097f45-9322-40e0-9452-a3560606348b">A unique identifier for an Attribute of an Information Object composed of an ordered pair of numbers (a Group Number followed by an Element number).</para>
                        </glossdef>
                    </glossentry>
                    <glossentry xml:id="glossentry_AttributeValue" xreflabel="Attribute Value">
                        <glossterm><emphasis role="bold"><emphasis role="underline">Attribute Value</emphasis></emphasis></glossterm>
                        <glossdef>
                            <para><emphasis role="bold"><emphasis role="underline">A Value of the Data Element corresponding to the Attribute of an Information Object.</emphasis></emphasis></para>
                        </glossdef>
                    </glossentry>
                    
                </glossdiv>
            </glossary>
        </section>
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference DICOM PS3.1 unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="3" status="1" xml:id="chapter_3">
            <title>Definitions</title>
            <glossary>
                <title/>
                <glossentry xml:id="glossentry_Attribute" xreflabel="Attribute">
                    <glossterm>Attribute</glossterm>
                    <glossdef>
                        <para xml:id="para_6918bd83-fed4-4a97-882a-3e200b3c2878">A property of an Information Object. An Attribute has a name and a value that are independent of any encoding scheme.</para>
                    </glossdef>
                </glossentry>
                <glossentry xml:id="glossentry_DataElement" xreflabel="Data Element">
                    <glossterm>Data Element</glossterm>
                    <glossdef>
                        <para xml:id="para_fb6c4bfb-93ea-4500-8c94-2ea10f3a26a6">A unit of information as defined by a single entry in the data dictionary.</para>
                    </glossdef>
                </glossentry>
            </glossary>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference DICOM PS3.5 unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="3" status="1" xml:id="chapter_3">
            <title>Definitions</title>
            <glossary>
                <glossdiv label="3.10" status="2" xml:id="sect_3.10">
                    <title>DICOM Data Structures and Encoding Definitions</title>
                    <para xml:id="para_830e2aa0-d7e3-4b32-badb-0ddba3f9cf4f">The following definitions are commonly used in this Standard:</para>
                    <glossentry xml:id="glossentry_DataElement" xreflabel="Data Element">
                        <glossterm>Data Element</glossterm>
                        <glossdef>
                            <para xml:id="para_a01acd74-4023-4cef-b617-e715f63e30e8">A unit of information as defined by a single entry in the data dictionary. An encoded Information Object Definition (IOD) Attribute that is composed of, at a minimum, three fields: a Data Element Tag, a Value Length, and a Value Field. For some specific Transfer Syntaxes, a Data Element also contains a VR Field where the Value Representation of that Data Element is specified explicitly.</para>
                        </glossdef>
                    </glossentry>
                    <glossentry xml:id="glossentry_DataElementTag" xreflabel="Data Element Tag">
                        <glossterm>Data Element Tag</glossterm>
                        <glossdef>
                            <para xml:id="para_25347c36-b9fa-4e24-b101-228b9e78b02c">A unique identifier for a Data Element composed of an ordered pair of numbers (a Group Number followed by an Element Number).</para>
                        </glossdef>
                    </glossentry>
                    <glossentry xml:id="glossentry_Value" xreflabel="Value">
                        <glossterm>Value</glossterm>
                        <glossdef>
                            <para xml:id="para_29381285-d983-4e26-84c9-9927044af3a1">A component of a Value Field. A Value Field may consist of one or more of these components.</para>
                        </glossdef>
                    </glossentry>
                    <glossentry xml:id="glossentry_ValueField" xreflabel="Value Field">
                        <glossterm>Value Field</glossterm>
                        <glossdef>
                            <para xml:id="para_412e145d-ca68-402e-8e39-007a7d3d1329">The field within a Data Element structure that contains the Value(s) of that Data Element.</para>
                        </glossdef>
                    </glossentry>