    <title>CP-2406</title>
    <subtitle>Clarify Series and Frame of Reference relationship for Whole Slide Microscopy Images</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/21</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/03/16</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2406</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Clarify Series and Frame of Reference relationship for Whole Slide Microscopy Images</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3 2024e</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The real-world model specifies that a Series is spatially defined by a single Frame of Reference and there is a specific statement in the Frame of Reference Module that each Series shall have a single Frame of Reference UID.</para>
                    <para>However, whole slide microscopy image series typically contain a mixture of images that may not be spatially related, such as label and overview (macro) images distinct from the pyramid layers, and it may be difficult if not impossible to establish their spatial relationship to the pyramid (and without purpose in the case of the label image).</para>
                    <para>Since the single Frame of Reference in a Series constraint has been long standing and may be required for some implementations, relax the requirement to include the Frame of Reference for WSI image types that are not spatially related.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis>
                        for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="7" status="1" xml:id="chapter_7">
            <title>DICOM Model of the Real World</title>
            <para xml:id="para_defe6fd0-b268-411f-bd92-52ae35979d7d">
                <xref linkend="figure_7-1a" xrefstyle="select: label"/>, <xref linkend="figure_7-1b" xrefstyle="select: label"/> and <xref linkend="figure_7-3" xrefstyle="select: label"/> depict the DICOM view of the Real-World that identifies the relevant Real-World Objects and their relationships within the scope of the DICOM Standard. It provides a common framework to ensure consistency between the various Information Objects defined by the DICOM Standard.</para>
            <para xml:id="para_f53afe55-447a-4c09-8d7e-58880b99f7f2">
                <figure label="7-1a" pgwide="1" xml:id="figure_7-1a">
                    <title>DICOM Model of the Real World</title>
                    <mediaobject>
                        <imageobject>
                            <imagedata fileref="cp2406_Series_FrameOfReference_WSI/PS3.3_7-1a.svg"/>
                            <!--<imagedata fileref="figures/PS3.3_7-1a.svg"/>-->
                            <!--<imagedata fileref="part03_fromword_files/image008.png"/>-->
                        </imageobject>
                    </mediaobject>
                </figure>
            </para>
            <note>
                <para><emphasis role="bold"><emphasis role="underline">Though typically a single Series is spatially defined by a single Frame of Reference, there may be situations in which a Series contains some Instances without a defined Frame of Reference.</emphasis></emphasis></para>
            </note>
        </section>
        
        <section label="A.32.8" status="3" xml:id="sect_A.32.8">
                <title>VL Whole Slide Microscopy Image IOD</title>
                <section label="A.32.8.3" status="4" xml:id="sect_A.32.8.3">
                    <title>VL Whole Slide Microscopy Image IOD Module Table</title>
                    <table frame="box" label="A.32.8-1" rules="all" xml:id="table_A.32.8-1">
                        <caption>VL Whole Slide Microscopy Image IOD Modules</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_eb33a04a-73c0-41fc-a4fe-7c8fb9316e64">IE</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7e383b2d-2788-4ee5-97e6-4bbf5959a5e8">Module</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0c39971c-5a9c-4692-9c43-97d2ca3b6275">Reference</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8fb856bb-dd94-4d2c-9d27-5ff66fca97fc">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_320c6918-9632-4a00-ae8a-5fb4b28e4d1a">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4a504b48-eab1-4980-a5b1-14019f96c3b6">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_41913b79-c971-46d9-baaa-e77ca219a2db">
                                        <xref linkend="sect_C.7.1.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_74e501ee-5c6b-4c35-afa4-2bb1a787e3e1">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5f24067a-a59a-447f-bf04-122394e66f26">Clinical Trial Subject</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e60dd6db-f988-4b4f-be9f-57e925fada8b">
                                        <xref linkend="sect_C.7.1.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3534f6a1-531a-495d-b610-1d1dcc6e85e8">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="3">
                                    <para xml:id="para_aeb48a77-9cb3-43fe-bfd7-53fa15c55b28">Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b675d7b-e7ec-448f-8279-e4a1b13bb774">General Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_68e8bbdb-c271-4881-9e2e-6b8c7336b0ef">
                                        <xref linkend="sect_C.7.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_be0da7ff-d024-4d35-b8b5-690a7122f8ed">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d4b5c158-89e5-4b7a-9d0b-c842f4228811">Patient Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fbf22541-795b-4447-8581-07f30ffc2a37">
                                        <xref linkend="sect_C.7.2.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_29c732e8-5042-4973-b160-e852dad1058d">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8bb0c4c-6b28-4c08-b099-16a8be6a3aa5">Clinical Trial Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e44eae31-157d-44e4-ba12-8a7a7484e54b">
                                        <xref linkend="sect_C.7.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_96ca5359-cd14-454b-9a9d-723afde6720b">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="3">
                                    <para xml:id="para_33b60570-e731-4d59-8d44-275339bf4891">Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f4d3383-6770-469d-b743-63e10616c06b">General Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ce2364eb-8390-4f0b-be8c-078a3d1c02af">
                                        <xref linkend="sect_C.7.3.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1c662022-0e24-448e-8cec-e9ea997ccd32">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dddf9296-1c3e-44d2-b8a8-45f6b15e6bd9">Whole Slide Microscopy Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9cfd56fe-cf65-47a0-9a54-dcdc6e0657e7">
                                        <xref linkend="sect_C.8.12.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_20cfb123-d696-41fc-92bf-fcf0acae9f62">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_95c0ab6b-7540-4e4d-9b95-337bb933a4b7">Clinical Trial Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_42678f44-4fd0-4fd1-a132-5f6557e1af4d">
                                        <xref linkend="sect_C.7.3.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6f950102-c4bb-4fe5-84ec-60a04683ca05">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d9957255-a01a-4661-8cd3-05818063f693">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1d08a784-8e38-45b4-917d-17875f6cf8e7">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c577f627-7be7-478b-bbd7-7eaed25fba03">
                                        <xref linkend="sect_C.7.4.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f108cea2-c2e5-47f9-a045-3a3e2aa4296e"><emphasis role="bold"><emphasis role="strikethrough">M</emphasis><emphasis role="underline">C - Required if Image Type Value 3 is VOLUME or THUMBNAIL. May be present otherwise.</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_5a145364-25f8-4ed7-b90b-1ad6f5adca85">Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7b5fbb2b-65f7-4e83-a9d3-f106d6befa62">General Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8486f4a6-56f9-44e7-9d0f-92e42a405d25">
                                        <xref linkend="sect_C.7.5.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91bab745-911c-4f5e-bb62-a6be7121a701">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_24325e10-ce95-4553-a3b8-b1d711c8bd51">Enhanced General Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c3d610bc-f1ae-4252-bae6-fece2cad0dc6">
                                        <xref linkend="sect_C.7.5.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_030bb10c-f0d6-4f07-85ae-258cdd38d92b">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a69f3132-83a5-4ef7-ac14-26b30e736162">Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d5f98bd9-5ddc-427e-a8d4-fa23b8d0aaca">General Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_58a18627-a213-4b1c-b46c-0bb81c7e9235">
                                        <xref linkend="sect_C.7.10.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d380cebf-1f31-4491-a339-d3f817a4dc98">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_62fcfdd7-e75f-4b32-ba6a-864ac108f1ce">Multi-Resolution Pyramid</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fea47fbf-4859-46e9-aebe-a6579a660710">Multi-Resolution Pyramid</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_05051387-cd69-4668-89d3-22fe6dbd278e">
                                        <xref linkend="sect_C.7.11.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_16dca78e-36ab-419d-95e4-6e65220fba98">U - Shall be present only if Image Type Value 3 is VOLUME or THUMBNAIL.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="14">
                                    <para xml:id="para_7375a25a-5403-4de8-9a4c-45b30c5be07a">Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f20a33ce-5b09-4dd7-8c69-37b2e0cda0b6">General Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_790b103c-7a37-4517-b467-f6f1108da467">
                                        <xref linkend="sect_C.7.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c162cc7-ae32-4a46-aa06-cb620d26a27d">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_97029079-24ab-4cd7-b101-6fdcd1b04311">General Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b827e86f-6eab-4903-847c-7e7a930817bc">
                                        <xref linkend="sect_C.12.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b78b86fa-c8f3-4b34-b17d-a67d81538aa3">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8d3ca43f-22a2-429c-bc3b-584f6d069f26">Microscope Slide Layer Tile Organization</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7203fdfa-486f-4d76-8243-4d42aec609ac">
                                        <xref linkend="sect_C.8.12.14" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c261e83d-13b5-497f-b0e9-25e75b538130">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2f883737-c2c7-4972-a4da-e70c019fb143">Image Pixel</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ca7e8f1a-ac02-49ed-bba3-289fe0435f40">
                                        <xref linkend="sect_C.7.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ced6afa9-37df-405c-bdba-a9c4b151166d">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d4596786-626f-462f-a32e-9c49a173f46c">Acquisition Context</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2f12e8ec-1ec0-41c6-999c-57d7a20cb2d0">
                                        <xref linkend="sect_C.7.6.14" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_84afd14d-b896-48db-88b3-b5530817cf37">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e15cd9e7-d68f-44eb-953d-540e0b4ca2b2">Multi-frame Functional Groups</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4f172328-99c9-4000-87c4-b2cb77ec3a3f">
                                        <xref linkend="sect_C.7.6.16" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_731c5a92-fd45-4ec9-8ac9-85d315abb765">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_746402a4-0af5-4630-a9d1-a654727e401c">Multi-frame Dimension</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5f895da2-3484-4b6b-8008-873c5d81f575">
                                        <xref linkend="sect_C.7.6.17" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_13e00028-3e42-4eeb-9157-802f96ca1b58">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_528f7ec0-77fc-4cf0-9971-08a704e580bf">Specimen</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0e13a989-972f-4c62-8eb0-96fee82f9373">
                                        <xref linkend="sect_C.7.6.22" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e7e7ae9-7986-48d2-be21-07cd491fe8d3">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5e1d6075-346d-4a57-b0ec-52a2234b92d7">Whole Slide Microscopy Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1bf64cff-c4c1-4e6b-853f-855bad364810">
                                        <xref linkend="sect_C.8.12.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_611700fc-a735-4464-840b-c66d18d3e095">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e3fc080-f518-4077-bb11-b7441c9a9925">Optical Path</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7cd0f9d8-1e96-48b0-8974-f999d7b841d6">
                                        <xref linkend="sect_C.8.12.5" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8b664085-1c72-494f-86b2-01c05d2f0f50">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0e07c6e5-9797-4dc6-9608-243b0158ab26">Slide Label</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f1a66d7-35a2-437a-8173-f706055c2da0">
                                        <xref linkend="sect_C.8.12.8" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4d77831d-26a2-466b-bd25-e8d29fb6b64a">C - Required if Image Type (0008,0008) Value 3 is LABEL; may be present otherwise</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fc1ca4b1-fd53-4b9d-8561-fcb30736d654">SOP Common</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_61998379-8957-42bf-bebe-8e94117a357b">
                                        <xref linkend="sect_C.12.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1a13a5e7-473a-4374-ab8a-733114bd3046">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb5e5f65-414e-4d97-ae1c-0f9ed2c6d328">Common Instance Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d0c8a88f-45dc-4b94-a7c1-a5359f24d54c">
                                        <xref linkend="sect_C.12.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dbbe92a1-082f-44a3-9342-abf8eb64720c">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_974f541e-478d-4fd4-a949-41ded223a630">Frame Extraction</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ff7e5cab-f99e-4551-9727-0755e020d958">
                                        <xref linkend="sect_C.12.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f14b76a7-69e2-4628-b35e-b9425325544c">C - Required if the SOP Instance was created in response to a Frame-Level retrieve request</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <note>
                        <orderedlist>
                            <listitem>
                                <para xml:id="para_a73cd9bb-02cf-4a83-868d-dcff93d35a40">The <xref linkend="sect_C.8.12.7" xrefstyle="select: title"/> was previously included in the Image IE for this IOD but has been retired. See <link xl:href="http://dicom.nema.org/medical/dicom/2021c/output/pdf/part03.pdf">PS3.3-2021c</link>.</para>
                            </listitem>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">In prior releases, the Frame of Reference Module had a Usage of M; see <link xl:href="http://dicom.nema.org/medical/dicom/2024e/output/pdf/part03.pdf">PS3.3-2024e</link>. However, since a single Series is spatially defined by a single Frame of Reference, to allow for Images within the same Series that may not be spatially related to the Images of the Multi-Resolution Pyramid, such as some LABEL and OVERVIEW images, the inclusion now has Conditional Usage.</emphasis></emphasis></para>
                            </listitem>
                        </orderedlist>
                    </note>
                </section>
            </section>
        
        
        
        
        
        
        
    </chapter>