    <title>CP-2236</title>
    <subtitle>Need to be able to select optical path in advanced blending presentation state</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/01/19</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Markus Daniel Herrmann</para><para><link
                    xl:href="mailto:MDHERRMANN@MGH.HARVARD.EDU"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2022/06/02</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2236</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Need to be able to select optical path in advanced blending presentation state</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3 2022e</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>It is currently not possible to reference a particular optical path in a VL Whole Slide Microscopy Image instance that contains more than one optical path.</para>
                    <para>In order to specify the blending of different optical paths, the Referenced Optical Path Identifier is added.</para>
                    <para>Only a single optical path may be specified, and it is required to be present if there is more than one optical path in the referenced image(s).</para>
                    <para>The reference is inserted as a sibling of the Image SOP Instance Reference Macro, invocation, rather than within it, since the reference to the optical path would not be appropriate for many invocations of the macro, especially in the bulk microscopy annotations where the attribute already exists at a different place in the IOD.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
      <section label="C.11.33" status="3" xml:id="sect_C.11.33">
                <title>Advanced Blending Presentation State Module</title>
                <section label="C.11.33.1" status="3" xml:id="sect_C.11.33.1">
                    <title>Advanced Blending Presentation State Module Attributes</title>
                    <table frame="box" label="C.11.33-1" rules="all" xml:id="table_C.11.33-1" width="1222">
                    <caption>Advanced Blending Presentation State Module Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ab5ff56e-0711-4ded-a949-fd52fad348de">Attribute Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2bafb6e-47d6-4342-aef0-3bbbb4dead81">Tag</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ac0a9ad-3de6-4431-8d51-c40714c4ec24">Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5d930fc2-bf28-4add-b7cb-c4d899d9d7dd">Attribute Description</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0be2c5cf-d4bc-43cd-81e2-5a416d5df0c6">Advanced Blending Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e761556f-079c-40b2-826c-8f440f63f593">(0070,1B01)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1b89367-bbbc-46bd-b27e-3a8e1fd34713">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71cd464a-4a8e-48e0-8492-fc85ecc104d8">A Sequence of Items identifying the inputs and describing transformations of them.</para>
                                <para xml:id="para_c37b26fb-3245-4063-8b9e-e5ccfb1f4743">One or more Items shall be included in this Sequence.</para>
                                <para xml:id="para_43be7394-845e-4cbb-b9ba-1eae570fc6da">See <xref linkend="sect_C.11.33.1.1" xrefstyle="select: label"/>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_118a3aad-ca17-4050-94fa-e4d32ccf66a3">&gt;Blending Input Number</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2298f437-2c6c-450a-836a-c890fcb07ee6">(0070,1B02)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_96663a71-317c-4338-9671-90e5d0f0ddb8">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5fab946-0f1e-4bee-b549-e565ff0484f3">Identification number of the input. Values shall be ordinal numbers starting from 1 and monotonically increasing by 1 within the Advanced Blending Presentation State Instance.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1012b696-75ef-4246-96b5-f744455a8c62">&gt;Study Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_326c3b02-59ba-4089-9d8e-df11dec4f478">(0020,000D)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9314c7b3-aa10-41d8-976e-922a9778cdb2">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a98d8f7f-a337-4370-9f79-2a2029d0a3b7">Unique identifier for the Study.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4a5e800-3a94-4c81-95b2-1d4f7f5b9d56">&gt;Series Instance UID</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cccf15d0-0f37-4ab4-9226-34f3b2c724e8">(0020,000E)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03fc6a8e-0166-4226-9d0a-4833d5bed282">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_218c6076-248a-413a-b03c-72acb7d0bb30">Unique identifier of a Series that is part of the Study defined by the Study Instance UID (0020,000D)</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0e6c2e84-f3d8-4f67-b93a-14c9653776a8">&gt;Referenced Image Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6572fd00-da42-413f-b9f8-854d4640c2a0">(0008,1140)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_49b11f0b-98bb-4920-966e-84283ff00a8a">1C</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65ccfa74-d054-41b8-8925-c9bb44e703fc">The set of images comprising this input. One or more Items shall be included in this Sequence.</para>
                                <para xml:id="para_8dd972dd-5b82-4c89-a545-b347f3ba2f55">Required if the input is not the entire set of Instances in the Series.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="3" rowspan="1">
                                <para xml:id="para_695e19e7-42d6-42ef-9f1a-1e556b3cd148">
                                    <emphasis role="italic">&gt;&gt;Include <xref linkend="table_10-3" xrefstyle="select: label quotedtitle"/>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edc4a695-07ea-4fcd-86b2-bfb526a1bc5d">
                                    <emphasis role="italic"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;Referenced Optical Path Identifier</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(006A,000E)</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1C</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">A single value that identifies the optical path that is the input.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">Refers to the value in Optical Path Identifier (0048,0106) within the Optical Path Sequence (0048,0105) in the images to which this Presentation State applies.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">Required if more than one Optical Path is present in the images to which this Presentation State applies.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2943a62-3acf-4109-a56b-d801baca80a4">&gt;Referenced Spatial Registration Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea4ed2b5-8f4c-4c28-b00f-40679c790898">(0070,0404)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e4f1441-e75f-4ffd-86fd-9627bfb6ec69">1C</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e395a4f-bac7-415b-a9d2-75f040a58e61">A reference to a Spatial Registration Instance that is used to register the referenced inputs.</para>
                                <para xml:id="para_485f6b4a-9443-4f59-a2d7-484b028f1fe3">Only one Item shall be included in this Sequence.</para>
                                <para xml:id="para_9d1e96e8-d97a-4182-8021-8319f7ef7b20">Required if the Frame of Reference UID (0020,0052) value of the Images referenced by the Referenced Image Sequence (0008,1140) of this Item does not match the Frame of Reference UID (0020,0052) value of this Presentation State Instance. May be present otherwise.</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para>...</para>
                            </td>
                            <td align="center" colspan="1"/>
                            <td align="center" colspan="1"/>
                            <td align="left" colspan="1"/>
                        </tr>
                    </tbody>
                </table>
                </section>
            </section>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">DICOM PS3.3 for reference unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="C.37.1.2" status="4" xml:id="sect_C.37.1.2">
                        <title>Microscopy Bulk Simple Annotations Module</title>
                        <table frame="box" label=" C.37.1-2" rules="all" xml:id="table_C.37.1-2">
                            <caption>Microscopy Bulk Simple Annotations Module Attributes</caption>
                            <thead>
                                <tr valign="top">
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_9e12a06f-365a-4318-81e4-50a46c77254b">Attribute Name</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_c3cf0870-a9fa-40e4-bdad-2a408bf45c07">Tag</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_449a60e6-d73f-4829-8de4-9d27d3e5e230">Type</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_0ba2a913-6824-4cd0-a7ce-719a636e19c5">Attribute Description</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0b1ab4de-a8f3-4711-afde-1dcf3521b423">...</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_641ba884-6bc1-4955-959a-3da35c215c1f"/>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_0ee3249b-404f-413a-b281-27eae9f8f2ba"/>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_37448ced-197f-4a97-b3cf-02a2e59e1445"/>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_0291a4fc-c59d-45f1-851c-faa5f8adc64d">Referenced Image Sequence</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_0cb1dcdc-7f7f-48c0-9b39-69de3c100e45">(0008,1140)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_79c47171-8ef0-4808-a120-dcd8ba1af35d">1C</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_14e0c12c-b76f-4662-aa08-6ff5904a8e9a">The image to which this Annotation object applies.</para>
                                        <para xml:id="para_803fb313-4df0-4800-b09e-cb02f5be15ce">Only a single Item shall be included in this Sequence.</para>
                                        <para xml:id="para_c22550b9-4470-491d-88da-7c4fe2097954">Required if Annotation Coordinate Type (006A,0001) is 2D. May be present otherwise.</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="3" rowspan="1">
                                        <para xml:id="para_86c7a1f7-2660-43a3-9a87-48aa8c78e5be">
                                            <emphasis role="italic">&gt;Include <xref linkend="table_10-3" xrefstyle="select: label quotedtitle"/>
                                            </emphasis>
                                        </para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_f1b5cd8e-b9d7-46a8-86ab-0713c51de3bf">
                                            <emphasis role="italic"/>
                                        </para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1b783a9f-09b8-4942-8334-5452e5b86a4f">Annotation Group Sequence</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_8511d0f1-92e2-42e8-82df-fa8b4699a336">(006A,0002)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_f009647d-67aa-4730-b65a-6c34e48d6ba4">1</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b60ced3d-a3a3-460e-9c04-50cfe4aefcee">Groups of Annotations sharing common characteristics, such as graphic type, properties or measurements.</para>
                                        <para xml:id="para_0af6e48d-ba27-4d67-9f8d-7d90e2bb95be">One or more Items shall be included in this Sequence.</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5cc929ea-1d7e-4861-8893-296b1b59b267">...</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_82a31d66-12c2-48ce-97e9-ee7fdc568c1c"/>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_530b2f95-b4e1-44dd-9c3b-cb4132c587b5"/>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_ca8eaaae-6b98-4820-9d24-04a979b931e2"/>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_3f9fe3df-a514-4596-bf05-00fbc1bd6df8">&gt;Referenced Optical Path Identifier</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_7878ea1a-a768-496e-acda-2391176e6b2c">(006A,000E)</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_740d055a-a62f-4201-8c64-d9d1a184e25c">1C</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2113537a-8a1b-4e9c-aad7-18e4b9c141c1">Identifies one or more optical paths to which this Annotation applies.</para>
                                        <para xml:id="para_d65837b9-2722-4ef4-8481-60acc05c24ec">Refers to the same value in Optical Path Identifier (0048,0106) within the Optical Path Sequence (0048,0105) in the images to which this Annotation applies.</para>
                                        <para xml:id="para_0025e684-c3dc-4cc5-95af-1472e7399fa3">More than one value may be present if the Annotations apply to more than one (but not all) Optical Paths.</para>
                                        <para xml:id="para_60cebe61-f768-4dc6-a5c5-5178ca221b80">Required if Annotation Applies to All Optical Paths (006A,000D) is NO.</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d5328d81-83a3-4113-9db6-83fde0f3b392">...</para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_1a50b57e-d19e-47e9-bd8d-c7710534d0f6"/>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para xml:id="para_306193ca-21e6-46d4-8295-1d70a22508a8"/>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_2e7787cd-1e83-45d2-9428-132ec497eb6e"/>
                                    </td>
                                </tr>
                            </tbody>
                        </table>
                    </section>
        
        <section label="10.3" status="2" xml:id="sect_10.3">
      <title>Image SOP Instance Reference Macro</title>
      <table frame="box" label="10-3" rules="all" xml:id="table_10-3">
        <caption>Image SOP Instance Reference Macro Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_c004ece0-f1f7-4597-b689-6669d88c6579">Attribute Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_bd9d5b65-657d-40b0-b455-18d7b573e06f">Tag</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_89897585-548c-4f02-8dc6-0f4380e6e794">Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_7018df71-786b-45ee-8068-23e2bd049403">Attribute Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_ae25377d-28bd-43a9-8653-b600c99dd819">
                <emphasis role="italic">Include <xref linkend="table_10-11" xrefstyle="select: label quotedtitle"/>
                </emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_88a4c8be-9e35-40b3-86f7-19d6dd498365"/>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_2789c5e8-a253-4237-8d95-72cdc43d1edf">Referenced Frame Number</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_58e622b7-4a47-4938-96dd-d3073aeea4b0">(0008,1160)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_6acdc911-a087-43b4-a068-a8e756eaa132">1C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_26b17b47-2064-4754-a98d-288d36b104d8">Identifies the frame numbers within the Referenced SOP Instance to which the reference applies. The first frame shall be denoted as frame number 1.</para>
              <note>
                <para xml:id="para_68450e47-9448-4ac5-82e8-4015a854968a">This Attribute may be multi-valued.</para>
              </note>
              <para xml:id="para_01a320b0-09fc-4c2e-a478-1eaa82de3416">Required if the Referenced SOP Instance is a multi-frame image and the reference does not apply to all frames, and Referenced Segment Number (0062,000B) is not present.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bbb881e3-b0b5-4a6d-bcb5-f4ffd5fbe837">Referenced Segment Number</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_d69702bd-c6a6-4cbd-86e0-7d71a791dc6c">(0062,000B)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_3a684360-c4f6-4da5-bd83-8eb296e386d2">1C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d27bd98a-7385-426d-baa4-2fb5d7572d0c">Identifies the Segment Number to which the reference applies.</para>
              <para xml:id="para_435cfa21-4755-4a64-847f-643b0ac2f953">Required if the Referenced SOP Instance is a Segmentation or Surface Segmentation and the reference does not apply to all segments and Referenced Frame Number (0008,1160) is not present.</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
        
        <section label="10.8" status="2" xml:id="sect_10.8">
            <title>SOP Instance Reference Macro</title>
            <table frame="box" label="10-11" rules="all" xml:id="table_10-11">
                <caption>SOP Instance Reference Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a42bead-86fd-4f7b-8207-2e881965ab73">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70ae57b5-e439-4067-bc95-e80d14d1fa04">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d34eb0c1-3332-4ca0-a083-ab76f3cb6533">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1de58578-d160-4168-9c8c-d2466626ce85">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_01f3f1cd-dd4d-471c-b080-9961faf6d1fb">Referenced SOP Class UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2fab2a1-95b0-4b70-a566-6d84cf79331f">(0008,1150)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc719629-f544-459b-93f4-ea556d10f880">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_63809a86-e616-4736-811b-d8de9a2a076c">Uniquely identifies the referenced SOP Class.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ee639991-ef92-4300-9a16-339d6e7d18b0">Referenced SOP Instance UID</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbe8fcac-5c05-4c18-ae71-d9bb8875962b">(0008,1155)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_917913b4-a3fa-45eb-ab44-e0d4142b5626">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e163fe69-a141-4d4a-8f47-dfaa443fdddb">Uniquely identifies the referenced SOP Instance.</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        

        
        
        
        
        
        
        
        
    </chapter>
</book>