    <title>CP-2042</title>
    <subtitle>Add SV and UV Selector Attributes</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/10/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier <link xl:href="mailto:dicom@jriesmeier.com>"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2020/04/02</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2042</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add OV, SV and UV Selector Attributes</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.6 2020d</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The "OV" (Other 64-bit Very Long), "UV" (Unsigned 64-bit Very Long) and "SV" (Signed 64-bit Very Long) added in CP 1819 do not have selector attributes.</para>
                    <para>The definition of Selector Attribute VR (0072,0050) does not need updating, because the list of its enumerated values is already de-referenced to PS3.5.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.3 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="10.26" status="2" xml:id="sect_10.26">
      <title>Attribute Value Macro</title>
      <table frame="box" label="10.26-1" rules="all" xml:id="table_10.26-1">
        <caption>Attribute Value Macro Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_3bd27fea-40c0-4e6b-aeb0-594b7b13b5c4">Attribute Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_08439df6-505d-417d-9161-25dc9d1d6b18">Tag</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_3d225a09-cbea-4b23-ae4c-be77b5e4418d">Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_c99108d8-f479-4bfc-9313-a6be665f7e3b">Attribute Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
                        <td>..</td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_67522a8b-6708-451c-a2b0-f98e434393c0"/>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_b0b022f1-7ae1-45c8-98ac-88e8e9fe8f2b"/>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_abb5af2b-09ef-4229-9970-0b7d9a049745"/>
            </td>
          </tr>

            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">Selector OV Value</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">(0072,0081)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">1C</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">The value of the Attribute identified by Selector Attribute (0072,0026).</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">Required if Selector Attribute VR (0072,0050) is present and the value is OV.</emphasis></emphasis></para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">Selector SV Value</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">(0072,0082)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">1C</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">The value of the Attribute identified by Selector Attribute (0072,0026).</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">Required if Selector Attribute VR (0072,0050) is present and the value is SV.</emphasis></emphasis></para>
                </td>
            </tr>
            <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">Selector UV Value</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">(0072,0083)</emphasis></emphasis></para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                    <para><emphasis role="bold"><emphasis role="underline">1C</emphasis></emphasis></para>
                </td>
                <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">The value of the Attribute identified by Selector Attribute (0072,0026).</emphasis></emphasis></para>
                    <para><emphasis role="bold"><emphasis role="underline">Required if Selector Attribute VR (0072,0050) is present and the value is UV.</emphasis></emphasis></para>
                </td>
            </tr>
        </tbody>
      </table>
    </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new Data Elements to PS3.6 as follows:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="6" status="1" xml:id="chapter_6">
            <title>Registry of DICOM Data Elements</title>
            <table frame="box" label="6-1" rules="all" xml:id="table_6-1">
                <caption>Registry of DICOM Data Elements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e8c52d5-3582-4ec4-a7e6-acd7604caf32">
                                <emphasis role="bold">Tag</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac298c3b-bcdd-462b-9240-c38e738bfb7c">
                                <emphasis role="bold">Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99f6b0ff-e1b0-484e-83b5-c3003d61704c">
                                <emphasis role="bold">Keyword</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42b3621d-8b30-46eb-8992-10bb21310ac7">
                                <emphasis role="bold">VR</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_551ea829-a949-4bfd-a201-bb102024e64c">
                                <emphasis role="bold">VM</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a18713f-2e81-4664-b9a1-e4e3d41957ab"/>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>(0072,0081)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Selector OV Value</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Selector​OV​Value</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>OV</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>(0072,0082)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Selector SV Value</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Selector​SV​Value</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>SV</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>(0072,0083)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Selector UV Value</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Selector​UV​Value</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>UV</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
                 
         



         
         

    </chapter>
</book>