<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1892</title>
    <subtitle>Correct code meanings for body surface area codes</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/11/08</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Wim Corbijn van Willenswaard</para><para><link
                    xl:href="mailto:wim.corbijn.van.willenswaard@philips.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/02/14</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1892</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct code meanings for body surface area codes.</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16 2019d</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The code meanings contain spurious spaces, inconsistent use of multiplier symbol (*, sometimes elided), and in some cases are inconsistent with their definitions.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="CID 3663" status="3" xml:id="sect_CID_3663">
            <title>Body Surface Area Equations</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_811cd8d8-9495-426d-bf2d-8b060554580b">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3663.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_3663.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_3663.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.180.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_78bdd59b-6388-43bc-9776-35011ecd80ae">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_57b412c4-17e2-44a3-bd52-3d2734a23574">
                            <emphasis role="bold">20100609</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_48c63094-2545-4bb1-9426-8f2558e265c6">
                            <emphasis role="bold">1.2.840.10008.6.1.180</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 3663" rules="all" xml:id="table_CID_3663">
                <caption>Body Surface Area Equations</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72cb8d0b-be39-4da9-a7a5-be6f9531be47">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f4afc50d-493b-46de-b578-5680056fa384">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f62eace2-3117-44c4-b75a-2076785c7658">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a28c9d95-8937-46f9-88c4-907f29825334">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3c20e17b-3dea-483f-b2f9-c35396e6c9a4">
                                <link linkend="DCM_122240" xrefstyle="select: nopage">122240</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_31104db7-c1dd-4e73-b2af-9aec9ca398fb">BSA = 0.003207*WT^(0.7285-0.0188<emphasis role="bold"><emphasis role="strikethrough"> </emphasis><emphasis role="underline">*</emphasis></emphasis>log<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>(WT))<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*HT^0.3</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_26af4a99-98b9-4afe-a1a6-8a38f2d7b21a">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_74760574-80fb-4f74-9d18-b0ce81240365">
                                <link linkend="DCM_122241" xrefstyle="select: nopage">122241</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f4c4f318-207b-4cc9-9442-89363b6571dc">BSA = 0.007184*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.425*HT^0.725</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c34d402-0d2f-4b32-b97b-eb24890305f2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddcc734c-9b9c-464e-8216-ec251ca7c34a">
                                <link linkend="DCM_122242" xrefstyle="select: nopage">122242</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a6e7f212-3470-423b-9461-dc4f47911eb8">BSA = 0.0235*WT^0.51456*HTcm^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.42246</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e57e25e5-6b13-4621-8cce-04c0e254ccad">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11273c0c-d661-4c29-868a-863a1986182d">
                                <link linkend="DCM_122243" xrefstyle="select: nopage">122243</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c43a2fcf-e7e7-45de-a7bb-526f37e015a3">BSA = 0.024265*WT^0.5378*HTcm^0.3964</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25a11dc2-1cb5-482a-93b9-52fc11ca96f5">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16eebd44-01e4-4881-bcfc-352dfe577f9d">
                                <link linkend="DCM_122244" xrefstyle="select: nopage">122244</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f8d3d43d-8ff7-4fe4-8535-047d1839b6dd">BSA = (HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT/36)<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^0.5</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f8b93d9b-18ff-40a9-9a01-9d675250fa7f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad935650-6e67-4b4b-b1d0-10d0f5474bc6">
                                <link linkend="DCM_122245" xrefstyle="select: nopage">122245</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_330d3cb7-6549-4e59-9c92-41c94c97b943">BSA = 1321+0.3433*WT</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc33131b-99cf-445a-87e6-461d44655827">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_589b774a-15fa-45ac-b4a0-157c6b70690c">
                                <link linkend="DCM_122246" xrefstyle="select: nopage">122246</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ea372b0b-2c1c-49a3-a023-c6854f6552be">BSA = 0.0004688*WT^(0.8168-0.0154*log(WT))</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c592c89-6f9c-495c-8654-e8a0bd1b8d1b">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe278cce-91b2-47c0-972e-250233ead9f5">
                                <link linkend="DCM_122266" xrefstyle="select: nopage">122266</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fe84c195-0fc4-43a9-8fb9-b6b95cd1dde6">BSA = 0.007358*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.425*HT^0.725</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9fdd8184-035b-4f67-b2ae-53b08dd36830">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2159f5c-73bc-4dea-af7c-9258bbbc0db0">
                                <link linkend="DCM_122267" xrefstyle="select: nopage">122267</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ac4e859-e54f-41fc-b4c1-ea2f0be46a6d">BSA = 0.010265*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.423*HT^0.651</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6fcb017-a959-473c-a1eb-091c3e6e609d">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c6c21b4b-61e7-4db5-a5b0-e75cb497ede5">
                                <link linkend="DCM_122268" xrefstyle="select: nopage">122268</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4255a56b-b966-4c99-915b-9b2eb538ed8f">BSA = 0.008883*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.444*HT^0.663</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b30d7600-54b4-408e-b574-279e9e9bccc6">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a152392-692d-442a-850c-d3080d23e5aa">
                                <link linkend="DCM_122269" xrefstyle="select: nopage">122269</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dd4c3f0c-e217-445f-b091-605d8d6315ce">BSA = 0.038189*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.423*HT^0.362</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f7b8b32-1c07-4ddc-8c54-fb43daddd542">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbb8e7dc-9e6f-4c5a-8bc1-f28fbd1968d9">
                                <link linkend="DCM_122270" xrefstyle="select: nopage">122270</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f2bf996b-d34e-4676-b8f0-05906bed5f38">BSA = 0.009568*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.473*HT^0.655</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <para xml:id="para_3cce97e2-c3f2-4dcd-bd55-9bf6bc7f7f2a">This Annex specifies the meanings of codes defined in DICOM, either explicitly or by reference to another part of DICOM or an external reference document or standard.</para>
            <para xml:id="para_89a5e18f-1781-4007-be8c-654d60de917b">The contents of this table are available in OWL format at
                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/ontology/dcm/dcm.owl" xl:show="new"/>
                and in <link xl:href="https://bioportal.bioontology.org/ontologies/DCM" xl:show="new">Bioportal</link>.</para>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
        
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122240">122240</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_5ada4123-aa66-4189-aa1d-252fdcdc1e80">BSA = <emphasis role="bold"><emphasis role="underline">0.00</emphasis></emphasis>3<emphasis role="bold"><emphasis role="strikethrough">.</emphasis></emphasis>207*WT^(0.7285-0.0188<emphasis role="bold"><emphasis role="strikethrough"> </emphasis><emphasis role="underline">*</emphasis></emphasis>log<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>(WT))<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*HT^0.3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_5b316754-a66b-456b-ad93-4cc851062151">Body Surface Area computed from patient height and weight: BSA = <emphasis role="bold"><emphasis role="underline">0.00</emphasis></emphasis>3<emphasis role="bold"><emphasis role="strikethrough">.</emphasis></emphasis>207*WT[g]^(0.7285-0.0188<emphasis role="bold"><emphasis role="strikethrough"> </emphasis><emphasis role="underline">*</emphasis></emphasis>log<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>(WT[g]))<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.3 [Boyd E, The growth of the surface area of the human body. Minneapolis: University of Minnesota Press, 1935, eq. (36) ].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_871a303d-8617-4542-bf9a-3467823f75ff"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122241">122241</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_f6ed269a-8e55-4a5d-8184-bec97f80c2fd">BSA = 0.007184*WT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.425*HT^0.725</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_55f365ef-cf5c-4d75-9e76-7e9e6b2bd47b">Body Surface Area computed from patient height and weight: BSA = 0.007184*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.425*HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.725 [Dubois and Dubois, Arch Int Med 1916 17:863-71].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_83cf6397-adeb-4cc9-93e3-109dd6234c6e"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122242">122242</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_bb5a71ca-bac8-4e38-a609-dfd932111fe2">BSA = 0.0235*WT^0.51456*HT^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.42246</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_9736f5b7-1801-4544-bd35-254009a53560">Body Surface Area computed from patient height and weight: BSA = 0.0235*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^0.51456*HT[cm]^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.42246</para>
                <para xml:id="para_6f207220-a60e-4255-bf23-29646837027f">[Gehan EA, George SL, 'Estimation of human body surface area from height and weight', Cancer Chemother Rep 1970 54:225-35].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_9a9f93c3-2491-4a53-88a4-a0f5f18ba0fa"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122243">122243</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_4e7867bc-1d7f-4bd9-92a7-17d80dcf9dbd">BSA = 0.024265*WT^0.5378*HT^0.3964</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_564b01c7-0593-429d-b011-71c1dc999ccf">Body Surface Area computed from patient height and weight: BSA = 0.024265<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.5378<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.3964</para>
                <para xml:id="para_8b0696b6-a1e4-46cb-9c35-44777008c8af">[Haycock G.B., Schwartz G.J., Wisotsky D.H. 'Geometric method for measuring body surface area: A height weight formula validated in infants, children and adults.' The Journal of Pediatrics 1978 93:1:62-66].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_57086927-c0d7-4670-a39d-ab552b47d598"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122244">122244</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_f1ab287a-c879-4ec4-9703-7d73a570fe76">BSA = (HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT/36)<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^0.5</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_d2c371cf-10ab-4eff-9b5c-7dcf1b9f6fcb">Body Surface Area computed from patient height and weight: BSA = (HT[m]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg] / 36)<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.5</para>
                <para xml:id="para_8437da7b-58ec-49be-8bc9-c3537c92b548">[Mosteller, R.D. 'Simplified Calculation of Body Surface Area.' N Engl J Med 1987 Oct 22;317(17):1098].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_61c4b080-d7d0-4465-a7d3-2ddb6b271ecc"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122245">122245</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ca1adf11-60ae-488b-811a-10388649cb5d">BSA = 1321+0.3433*WT</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_34893e09-025d-43b4-ac04-a019278e4c9d">Body Surface Area computed from patient weight:BSA = 1321 + 0.3433<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg] (for pediatrics 3-30 kg) [Current, J.D. 'A Linear Equation For Estimating The Body Surface Area In Infants And Children', <emphasis role="italic">The Internet Journal of Anesthesiology</emphasis>. 1998. 2:2].</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_31850e64-9106-44f2-a567-7fc81f0579cb"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_122246">122246</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_7240a40f-4469-4418-8a87-392d997d2b4c">BSA = 0.0004688<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>(0.8168<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>-<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.0154<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>log(WT))</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_a4b68390-b5f9-4004-bc10-2b4587548ea9">BSA = 0.0004688<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>(1000<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT)<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>(0.8168<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>-<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.0154<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>log(1000<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT))</para>
                <para xml:id="para_f825cca7-41ff-4491-98f9-1d3132fbbf0c">Where (WT is weight in kilogram)</para>
                <para xml:id="para_6703ea5e-e15b-41cc-8c22-2770e21b0022">Units = m2</para>
                <para xml:id="para_3f564c36-666c-4c46-9384-87edba30a77f">Boyd, Edith. <emphasis role="italic">The Growth of the Surface Area of the Human Body</emphasis>(originally published in 1935 by the University of Minnesota Press), Greenwood Press, Westport, Connecticut, 1975, p. 102.Equation (35).</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_baf9bcb5-a06e-4d0c-990d-ac1699cc3235"/>
            </td>
        </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_122266">122266</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b7f9fcc6-6df4-4139-8c1a-b8860232a536">BSA = 0.007358<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.425<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.725</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e134fede-7f06-4010-9a6c-47a51f2d43e6">Body Surface Area computed from patient height and weight: BSA = 0.007358<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.425<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.725</para>
                            <para xml:id="para_ad8ca6d7-b4dc-4cfc-8463-1db02f33f6fa">(for East Asian adult, aged 15+ years) [Kanai Izumi, Masamitsu Kanai, 'Clinical examination method summary'].</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9623a8dc-7a8b-4507-8721-c8d22c5e4223"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_122267">122267</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fc8b5f87-7a18-447d-acb0-9b71532e76a7">BSA = 0.010265<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.423<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.651</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a3e0d076-275e-4bb7-ae8e-fff5ddbe4381">Body Surface Area computed from patient height and weight: BSA = 0.010265<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.423<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.651 (For East Asian child aged 12-14 years).</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c9be0be3-70e5-427b-a432-beacf27b3325"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_122268">122268</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_09d3ac1c-dd28-45e3-b44d-8d65b924ad4a">BSA = 0.008883<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.444<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.663</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bba39201-bc3f-4189-b6ed-2f6d6c09f1c4">Body Surface Area computed from patient height and weight: BSA = 0.008883*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.444<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.663 (For East Asian child aged 6-11 years).</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a2333119-030d-4654-9262-3a7745946c61"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_122269">122269</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a5c8570d-64f9-4b3c-8754-6eafa9c05b2c">BSA = 0.038189<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.423<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.362</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ca97cb4e-730c-4792-b98b-600d87bf980f">Body Surface Area computed from patient height and weight: BSA = 0.038189<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.423<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.362 (For East Asian child aged 1-5 years).</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1b66d5cb-676c-408a-a403-1132617ddc4d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_122270">122270</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2649b54b-3af1-480a-aec8-5f898f001bed">BSA = 0.009568<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.473<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.655</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e162723d-0693-49e8-a51b-e80911cd650b">Body Surface Area computed from patient height and weight: BSA = 0.009568*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>WT[kg]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.473<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>*<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>HT[cm]<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>^<emphasis role="bold"><emphasis role="strikethrough"> </emphasis></emphasis>0.655 (For East Asian child aged 0-12 months).</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7b46331a-c6f5-44e8-8e77-2fa3f2ef3c3c"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
      


        
        
        
        
          
        
         
    </chapter>
</book>