<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1886</title>
    <subtitle>Add trans-rectal to ultrasound beam path context group</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/11/08</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/02/05</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1886</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add missing trans-rectal to ultrasound beam path context group.</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3 2019d</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>A trans-rectal or trans-urethral approach may be used for prostate ultrasound.</para>
                    <para>Also remove synonym in code meaning for trans-vaginal.</para>
                    <para><emphasis role="italic">[Ed.Note: SNOMED subset requests #741406, 741407.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="CID 7" status="3" xml:id="sect_CID_7">
         <title>Ultrasound Beam Path</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_860149bd-00b5-4bee-8470-43b584dfbb13">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.5.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_39fc0454-48e6-4e91-bccb-80467adc5de7">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_b048d956-d3c8-4986-8494-75fa2fdc0a15">
                            <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">20191108</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_81a07981-5852-4517-91c9-9d3cc0dff9e8">
                     <emphasis role="bold">1.2.840.10008.6.1.5</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
<table frame="box" label="CID 7" rules="all" xml:id="table_CID_7">
            <caption>Ultrasound Beam Path</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bd6c1b91-606a-4684-87c7-4d22918a189c">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1cc95350-42e0-40c1-bf14-4ff7f6975407">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_244470e8-8773-4b49-9370-bfab6edfacb8">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_562d3308-5dac-476b-a73b-1bd1d528b60f">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca2934bd-6996-4cfb-a0d5-596d9cbbd93a">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ca236650-55de-4665-9231-002123cb007e">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fce6c449-dfcf-42db-91e7-4b76318a58dc">
                        <link xl:href="http://snomed.info/id/103381007" xl:show="new">103381007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_002397e1-894e-4578-bdea-c353e74c4fa6">Trans-hepatic</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_689005da-ed9f-4d00-be95-ede3ba2fb6a9">
                        <link xl:href="http://snomed.info/id/103381007" xl:show="new">G-D027</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_565fd74b-0228-4cdc-a335-6a954da72c27">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522516" xl:show="new">C0522516</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_969d569f-b574-44e7-83c5-738ff9ff4766">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c067bef9-d276-4218-8797-7c29d41a0852">
                        <link xl:href="http://snomed.info/id/103353001" xl:show="new">103353001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_37453c04-0b98-4069-854b-a2ce63b9666a">Trans-gastric</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_32e198b8-455f-430a-a689-448f308f634d">
                        <link xl:href="http://snomed.info/id/103353001" xl:show="new">G-A1B2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ece4aecc-e698-4966-ade7-9fa700f689f5">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0442355" xl:show="new">C0442355</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a753ed56-44e2-40df-b33c-b0361337a393">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a5a6cdcb-fd0d-4c87-9570-ba3da74cbc55">
                        <link xl:href="http://snomed.info/id/103348006" xl:show="new">103348006</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_49525273-305a-4113-b82c-54afed8bc0c1">Trans-pleural</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a256f447-fe4c-4a4e-af7d-4b3190b2687a">
                        <link xl:href="http://snomed.info/id/103348006" xl:show="new">G-A1A5</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9365c474-dc2d-4f04-8587-e1d6863ef077">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522494" xl:show="new">C0522494</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9ba5cbde-8560-48fc-b2a9-3cc2e0d1dab5">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_de4acbff-6c53-46e5-8959-616a60e4ffd7">
                        <link xl:href="http://snomed.info/id/103354007" xl:show="new">103354007</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_adc8642f-fc83-49ce-8bd3-522b92c00920">Trans-mural</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e374456a-7700-4c3e-a64a-51c539485749">
                        <link xl:href="http://snomed.info/id/103354007" xl:show="new">G-A1B3</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_55b4b8e4-b56d-443b-9390-b40d93c4eb28">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522497" xl:show="new">C0522497</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_68838989-bd0f-484a-9b2c-55b01a44d00f">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b73d7277-5735-4979-9246-8062cc8de31d">
                        <link xl:href="http://snomed.info/id/129226004" xl:show="new">129226004</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_63c14d6f-5762-47ea-bd9b-a83e97038c4a">Trans-orbital</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bd5d7472-a9fb-4329-94d2-162ac8f74ad0">
                        <link xl:href="http://snomed.info/id/129226004" xl:show="new">G-D065</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_09ab29e9-d6b6-4343-a2a0-1d5cbe2c595b">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0442367" xl:show="new">C0442367</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ab3dd666-de1b-479c-90f4-1f0f2f0876d8">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5914f8df-55dd-46fb-aa7e-6b61093cd6c0">
                        <link xl:href="http://snomed.info/id/103349003" xl:show="new">103349003</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_0f8646b4-81f1-4e1a-a265-69830eabe69e">Trans-pancreatic</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f12ef9d0-ad41-4d1f-964a-56fac2566094">
                        <link xl:href="http://snomed.info/id/103349003" xl:show="new">G-A1A6</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8778e64f-f20d-4565-8e1f-3fae9dcd23d4">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522495" xl:show="new">C0522495</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/6706003" xl:show="new"><emphasis role="bold"><emphasis role="underline">6706003</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Trans-rectal</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/6706003" xl:show="new"><emphasis role="bold"><emphasis role="underline">G-D028</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205518" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0205518</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_fe96917e-1d8e-4fde-85db-c673293d0ffa">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c75a3100-ca00-44d4-9c13-2aede9c8614d">
                        <link xl:href="http://snomed.info/id/103347001" xl:show="new">103347001</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_3f3a3565-843b-4508-b1b3-141160efb0d6">Trans-renal</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c2137e59-85c4-4b03-bd02-642b513a5227">
                        <link xl:href="http://snomed.info/id/103347001" xl:show="new">G-A1A4</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5cb47b69-06c2-42c2-b5d2-aea0110ee86d">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522493" xl:show="new">C0522493</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c603e2b7-1c92-4996-92da-cabacb41ac11">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_78aced6f-3a1a-4e67-b504-676bdbe5115d">
                        <link xl:href="http://snomed.info/id/103382000" xl:show="new">103382000</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_2c606cbc-57d1-4842-9531-76b6902d6d62">Trans-temporal</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6d0dcf81-284e-49d0-a2f0-2da24accee75">
                        <link xl:href="http://snomed.info/id/103382000" xl:show="new">G-D032</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3d0ec4db-860e-44e8-b8a9-03f7a862e2fc">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522517" xl:show="new">C0522517</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3ba0f88f-ed0e-489f-ad3a-4d7b51044fad">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_972aca18-d04c-4e41-92ac-0e173fdb6edf">
                        <link xl:href="http://snomed.info/id/103345009" xl:show="new">103345009</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_08fa7867-7b07-4cb4-ba0d-3097560175fb">Trans-thecal</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ecc02f7c-b1cb-4e4b-ab2b-b63e5b2e935d">
                        <link xl:href="http://snomed.info/id/103345009" xl:show="new">G-A1A2</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3f8c64ee-fc70-44f0-b6c4-5f400f2af9e8">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522492" xl:show="new">C0522492</link>
                     </para>
                  </td>
               </tr>
                <tr valign="top">
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/57257006" xl:show="new"><emphasis role="bold"><emphasis role="underline">57257006</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Trans-urethral</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://snomed.info/id/57257006" xl:show="new"><emphasis role="bold"><emphasis role="underline">G-D003</emphasis></emphasis></link>
                        </para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para>
                            <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205497" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0205497</emphasis></emphasis></link>
                        </para>
                    </td>
                </tr>
                <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d78cdc15-d5ff-4847-ab1c-6ab6799763d8">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9edd6d04-d486-4203-aaf0-d16ecbd0a00b">
                        <link xl:href="http://snomed.info/id/103344008" xl:show="new">103344008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_7cb6900d-24ce-4fd9-8f46-b83528a48f86">Trans-vesical</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0c04e5bb-ab25-451e-a05b-6f58ad6772d2">
                        <link xl:href="http://snomed.info/id/103344008" xl:show="new">G-A1A1</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_bcb7f6b5-8fdb-459f-8c46-410ff44e5a4e">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0442393" xl:show="new">C0442393</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_06c55316-7bf9-4784-8d78-42e70beff320">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_75c770a8-fe57-4879-a3c2-9e7b92f4dce8">
                        <link xl:href="http://snomed.info/id/103346005" xl:show="new">103346005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_32f710ee-af1d-4ad1-b9b6-90847ea82276">Trans-splenic</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_6c947a3e-f9d3-47db-8315-e6ddc8402b84">
                        <link xl:href="http://snomed.info/id/103346005" xl:show="new">G-A1A3</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_1aef7b82-f963-4ebd-b5f6-e45682cf42a9">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0589466" xl:show="new">C0589466</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0f48b00b-df58-4902-92a4-a373c7551efc">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c5c91420-9cfe-4109-8b4c-cd12b8795713">
                        <link xl:href="http://snomed.info/id/103383005" xl:show="new">103383005</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_20c6f539-d4ab-4d17-86e0-2c0da8647732">Trans-esophageal</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3452afae-f32c-43b9-b62f-d15107d87565">
                        <link xl:href="http://snomed.info/id/103383005" xl:show="new">G-D033</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9dc2de84-9d21-4d2c-af11-52004d2f9af2">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522518" xl:show="new">C0522518</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b7670dc7-d86d-4b8c-a65c-4ab2f6f72439">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c073404f-f54f-4c23-8824-ac2f5edbb05c">
                        <link xl:href="http://snomed.info/id/66739002" xl:show="new">66739002</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_735ff8b3-2455-4667-948e-8584f7e5c305">Trans-abdominal</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_27625ed4-cc8e-4256-b836-7973f9c081b5">
                        <link xl:href="http://snomed.info/id/66739002" xl:show="new">G-D001</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_97d44609-a6c2-498f-9e03-d08fdcec5ce8">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205496" xl:show="new">C0205496</link>
                     </para>
                  </td>
               </tr>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f59b812b-62fa-44cd-9fbc-fa313d307936">SCT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_837c07b6-5df1-4ec5-84db-90ce3b03a03c">
                        <link xl:href="http://snomed.info/id/54300008" xl:show="new">54300008</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_fb85ceca-0bdf-4bbe-a913-6901d3ceac6e">Trans-vaginal<emphasis role="bold"><emphasis role="strikethrough"> (endovaginal)</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d76acea9-88c6-4fb4-9a3d-9c280858e8c2">
                        <link xl:href="http://snomed.info/id/54300008" xl:show="new">G-D002</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9eea46fa-bb5c-44d3-b2d0-a79ea08163c0">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0175672" xl:show="new">C0175672</link>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
        </section>
        
        
          
        
         
    </chapter>
</book>