    <title>CP-1859</title>
    <subtitle>Distinguish Middle from Median</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/05/24</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>QIICR</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/10/14</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1859</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Distinguish Middle from Median</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16 2019b + CP 1858</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Anatomically, the term "median" is reserved for the mid-sagittal plane rather than being a generic qualifier meaning in the middle of some larger region regardless of orientation.</para>
                    <para>There is a need to distinguish "median" versus "middle" for various uses in the standard (e.g., to distinguish middle part of something from inferior/superior or anterior/posterior parts), even though SNOMED CT considers these synonyms.</para>
                    <para>Retire the use of the single SNOMED CT concept for middle/median/mid-longitudinal and use distinct clearly defined codes.</para>
                    <para>Also, add the concepts medial, median and middle to the Generic Anatomic Location Modifiers context group that is created by CP 1858.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID 2" status="3" xml:id="sect_CID_2">
         <title>Anatomic Modifier</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_f79bfe2d-c731-462b-bc87-562511d7f00e">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_2.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_2.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_2.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_49fff8bd-28af-4b8e-8147-3f6a707881c2">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_1f9d5e1e-e22c-4c79-9334-d0fc855fb49e">
                            <emphasis role="bold"><emphasis role="strikethrough">20190118</emphasis><emphasis role="underline">20190524</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_01f68e19-ed20-4d72-9402-1d4703778571">
                     <emphasis role="bold">1.2.840.10008.6.1.1</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 2" rules="all" xml:id="table_CID_2">
            <caption>Anatomic Modifier</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_3a9b23fd-5068-4717-9bf6-d3f02d125c4f">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2cba04db-6aad-491f-9535-9cb6ddcb7b49">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e264bd53-699c-449c-a651-3c58f2dd829c">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f5bdf765-9837-42df-891b-110329d322b8">
                        <emphasis role="bold">SNOMED-RT ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f7cb246a-b6f8-4cdc-a2df-639ec7208bc9">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_ee1bb2ec-9dea-4be6-b684-550523b47167"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">DCM</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f015ec93-971e-4864-9bb8-7fe07fbacb78">
                         <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                         <link linkend="DCM_130290" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">130290</emphasis></emphasis></link>
                            </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_f968de47-6324-42f3-80d7-9932e7c3ce94"><emphasis role="bold"><emphasis role="underline">Median</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_360520d6-b2dc-4cd5-80f3-1c8908a7377d">
                         <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">R-4081A</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f012cacd-d7cb-4fb0-8c1e-497d7eb721c2">
                         <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2939193" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C2939193</emphasis></emphasis></link>
                     </para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
        
        <section label="CID 245" status="3" xml:id="sect_CID_245">
            <title>Laterality with Median</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a61d554f-aa98-44f9-b7dc-3a0ec898eb64">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_245.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_245.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_245.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1267.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_50284886-a40f-4fcb-b735-d07d07503170">
                            <emphasis role="bold">Non-Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7d2e847f-0067-4565-961e-6172971f0b5e">
                            <emphasis role="bold"><emphasis role="strikethrough">20190118</emphasis><emphasis role="underline">20190524</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_12540ea0-ff55-43c2-88dc-a96fbaa21b44">
                            <emphasis role="bold">1.2.840.10008.6.1.1267</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 245" rules="all" xml:id="table_CID_245">
                <caption>Laterality with Median</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d7ef47f-9a79-4ace-95c4-622bb0148cfc">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1faf76b4-c363-4b09-93e6-c7a8bfba9ed5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44947743-56ed-4bd5-91eb-a1c2e24d5b03">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b16e0c96-7b35-4f66-87c8-223a2f74eea0">
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba214c3b-52dc-4955-86d9-db428ff23fcb">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b4d428a-12e0-4786-b6db-cd275e63f543"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bb92242-ec6f-4af3-9409-92a81226214d">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                                <link linkend="DCM_130290" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">130290</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5b351b96-5b45-4273-889c-6b6f0006b6cc"><emphasis role="bold"><emphasis role="underline">Median</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ab1f146-fbe5-4367-b89e-ce121753a3e5">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">R-4081A</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f050c948-1d93-4016-8946-273a4856dc39">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2939193" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C2939193</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 6025" status="3" xml:id="sect_CID_6025">
            <title>Depth from BI-RADS®</title>
            <note>
                <para xml:id="para_2b79b39f-bc74-46e9-b342-e15f11ab52f9">From BI-RADS® Third Edition (National Mammography Database, E99)</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e400c234-30f9-4d92-afcf-b54a061f40f1">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6025.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_6025.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_6025.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.355.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_48ac7d84-1f84-425b-a5b8-e26c41bdc11a">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f928e8e8-ad14-4726-8326-178dffc2fb2e">
                            <emphasis role="bold"><emphasis role="strikethrough">20160405</emphasis><emphasis role="underline">20190524</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_75f09b75-9775-49d3-86e1-d3452706a26b">
                            <emphasis role="bold">1.2.840.10008.6.1.355</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6025" rules="all" xml:id="table_CID_6025">
                <caption>Depth from BI-RADS®</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1be643f-3841-4d4e-8102-578a168ba0e7">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f157169-8a39-4fb0-b6fd-9f26d46945ae">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7c7e9cc-d683-4ad9-accb-9ebef8834749">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3f3ba1d-0279-47bf-abf7-0f909ce958f8">
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bbf0c697-a19a-4ba6-850d-5cf9293acdfe">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9f11d33-a6c1-4c4a-aae1-7581c704465b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40b92efa-329b-45d8-9820-1d9bf358e6b4">
                                <link xl:href="http://snomed.info/id/255549009" xl:show="new">R-404CC</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e49161a0-5ca5-498c-9c5e-1681df726a5b">Anterior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_acd5f1da-e51e-449a-afae-46ae158870b0">
                                <link xl:href="http://snomed.info/id/255549009" xl:show="new">255549009</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8450438a-6784-450a-8477-c63ff240349b">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1704448" xl:show="new">C1704448</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f10a157-baf0-482f-84fc-e9943cccab62"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">NCIt</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ef7d115-6930-4a9c-a98b-6abad02ef81a">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8fea9b1-3fec-4e24-84c4-b088a091c82a">Middle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b0fea10-4664-4b3b-a8d1-375988fa4be0">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">R-4081A</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85285fc3-393f-4538-a7c8-c494ee9ffb07">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2939193" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C2939193</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0444598" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0444598</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de6c8787-49fe-4b0e-ad4b-51312dc6fbf7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c1361b5-0701-4b01-86e0-5b6d16a9952d">
                                <link xl:href="http://snomed.info/id/255551008" xl:show="new">R-404CE</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_738006f5-9e13-4ea4-bf10-c2b13258b44e">Posterior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2064bab-0c65-47bd-9eff-d69f86ea7df6">
                                <link xl:href="http://snomed.info/id/255551008" xl:show="new">255551008</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ac17794-7bc6-4f54-b18f-609ae64a24ba">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205095" xl:show="new">C0205095</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 12116" status="3" xml:id="sect_CID_12116">
            <title>Vessel Segment Modifiers</title>
            <para xml:id="para_8cec932e-02ad-4da8-a608-430e9c0af6c5">This context group is the set of modifiers that specify the position along a vessel segment.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_707d0317-d1e3-490a-8251-9b2aa4ad5c17">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12116.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12116.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12116.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.583.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a26838ee-82c5-409d-a677-9b8373a9f1dc">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_691773d2-91d7-4415-8373-c4beb6f6196f">
                            <emphasis role="bold"><emphasis role="strikethrough">20050110</emphasis><emphasis role="underline">20190524</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7555f80e-217a-4b5e-aaa6-83fad83e9ab8">
                            <emphasis role="bold">1.2.840.10008.6.1.583</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 12116" rules="all" xml:id="table_CID_12116">
                <caption>Vessel Segment Modifiers</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59be19d3-4078-499a-8d51-293e9cad2e95">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f42674b6-169e-4360-9c58-0b00b07565c0">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e45929d-2a7a-416a-9f37-71739bc7ef3a">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60ef716d-f607-4cbb-b75a-7265b6c1bdef">
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f385860-45b8-48a1-b88d-19afcce60781">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_02ad54cf-7e50-46f1-8b0d-3a8b02d54a8e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0ea3600-9c49-4198-8f53-d622a17cfcb5">
                                <link xl:href="http://snomed.info/id/46053002" xl:show="new">46053002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6ec790ee-c77a-4e9e-a180-cb22da71f5b9">Distal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4eee5d5c-8403-4313-9d3e-113719a37a10">
                                <link xl:href="http://snomed.info/id/46053002" xl:show="new">G-A119</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87080483-7dc6-499f-b2d1-db8d6eef43f1">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205108" xl:show="new">C0205108</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e93b1fb4-90f6-4044-817c-6028729293a7"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">NCIt</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf22e00a-ddb1-443f-8dde-4c6b829f0213">
                                <link xl:href="http://snomed.info/id/103342007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">103342007</emphasis></emphasis></link>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b7bb9c0a-7577-4227-87d7-7cc064333e1b"><emphasis role="bold"><emphasis role="strikethrough">Mid-longitudinal</emphasis><emphasis role="underline">Middle</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_745ebc3d-61e3-4c19-9e6b-d54689a513dc">
                                <link xl:href="http://snomed.info/id/103342007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">G-A188</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c330d0f-b7d8-41f8-ac00-40576fd1f04f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522490" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C0522490</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0444598" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0444598</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_169ea348-a40e-40ab-b27e-4dd087997b84">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f58fb9de-cd4d-4187-b90c-586684218fff">
                                <link xl:href="http://snomed.info/id/397421006" xl:show="new">397421006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_634aa87d-545f-4e70-b1e0-d1dedd2c4613">Origin of vessel</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f24100a3-be05-470f-baa3-fb7f3de98aef">
                                <link xl:href="http://snomed.info/id/397421006" xl:show="new">G-036A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e9a1e421-97cd-429e-a17b-5c0f471a00bd">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1301415" xl:show="new">C1301415</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63f56846-e3a5-4538-baa2-058ad4c74976">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8002db62-fd3e-45ac-96da-aca4f12f5330">
                                <link xl:href="http://snomed.info/id/40415009" xl:show="new">40415009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c0498282-aa59-45a0-961d-f176d3a947fb">Proximal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9e54c24-d893-420f-8f4c-e17e9d0c42bd">
                                <link xl:href="http://snomed.info/id/40415009" xl:show="new">G-A118</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f35875e-559c-41a1-9eff-012ad765b515">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205107" xl:show="new">C0205107</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_007ba61e-4e7d-431c-8fc6-9866b42d168f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24acf4f6-894c-4afd-bc8d-bf2eaf756d86">
                                <link xl:href="http://snomed.info/id/413996005" xl:show="new">413996005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c4c80d49-cf3f-4769-9759-47091a29ed96">Dilated portion of segment</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dcd2eeb0-0793-47b6-8fc1-1dd0254691f7">
                                <link xl:href="http://snomed.info/id/413996005" xl:show="new">R-1025B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_272eea4d-2bf6-4dcd-8f93-9ea39857c6db">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1531687" xl:show="new">C1531687</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 12117" status="3" xml:id="sect_CID_12117">
            <title>Vessel Branch Modifiers</title>
            <para xml:id="para_d5d2db52-a061-4c25-b2b6-94ebe97f320d">This context group is the set of modifiers to specify a particular vessel segment or branch.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_32438605-24cd-4a69-8c07-d2d0af59f330">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12117.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12117.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12117.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.584.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_97b8e785-cd11-4e07-b3c0-0cf12ea21b11">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_dee6b5ac-1ca5-4701-a892-e919cb4dde0d">
                            <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">20190524</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6166a87c-5e43-4040-85e6-10f65255b2ab">
                            <emphasis role="bold">1.2.840.10008.6.1.584</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 12117" rules="all" xml:id="table_CID_12117">
                <caption>Vessel Branch Modifiers</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c499e2b-0d3b-413b-85ef-1bbf610448b4">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c50abe7-d4db-4e3b-93f8-06bbdda82da8">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d297d4b-82be-4924-bdb4-bc0a024ad884">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e179d06b-cc60-42f2-833a-474a6cba1a71">
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6397a251-a4d7-4381-8c53-bfa9ee444087">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c23b0f6-e073-441d-827f-238435ee1aba">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e1163c8-dc97-4010-85c4-59c0cf5c9f81">
                                <link xl:href="http://snomed.info/id/397406000" xl:show="new">397406000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6a9382fb-44a0-4b66-b9da-6406886c6c8a">Collateral branch of vessel</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84682c18-4511-49df-96ab-eda7746531c1">
                                <link xl:href="http://snomed.info/id/397406000" xl:show="new">G-035D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_707e1f23-81b8-47a0-92ab-b1bb1fd02ed0">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1275670" xl:show="new">C1275670</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d90fbc7-07f9-45e2-8fbd-00465275edd4">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e54a68d-70d0-42c1-9447-8aac6b7699bc">
                                <link xl:href="http://snomed.info/id/261089000" xl:show="new">261089000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e51c971d-6872-4c51-a630-9d9355d61218">Inferior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_865a0e6f-7300-4fa4-a833-31865bdd4d19">
                                <link xl:href="http://snomed.info/id/261089000" xl:show="new">R-4094A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3cb07112-37ec-4291-96f0-420afd62da77">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0542339" xl:show="new">C0542339</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70fe8231-fec2-49e9-9b1e-1d6bc3eba538">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3c9974ae-713a-4388-ba2d-1dbb2572a593">
                                <link xl:href="http://snomed.info/id/49370004" xl:show="new">49370004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd8dc896-db49-4fd5-a44b-b5715180a427">Lateral</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_867d4e1b-c23d-46f4-9200-e8601469dbb1">
                                <link xl:href="http://snomed.info/id/49370004" xl:show="new">G-A104</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_34c55f1d-132b-452d-8b66-9a7f52122cd5">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205093" xl:show="new">C0205093</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5e0c545-c3b8-49ac-a608-cf06d6cfb0c2">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1abaf96d-f692-4fcb-b171-024e9b7dce43">
                                <link xl:href="http://snomed.info/id/7771000" xl:show="new">7771000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c50d3b8a-2321-4df0-b19d-bda6b6a657ca">Left</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a453232-19a9-4b7b-bcac-fcf3dddf7603">
                                <link xl:href="http://snomed.info/id/7771000" xl:show="new">G-A101</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d170d7b-6b6a-4ff3-973f-cb63a91fa350">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205091" xl:show="new">C0205091</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bdf789ba-8af2-4053-a0b3-770ffd77db06">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_55b03a4a-ef0c-413a-b38b-c65a8633b0bf">
                                <link xl:href="http://snomed.info/id/63161005" xl:show="new">63161005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_29f3676a-d3e7-4dee-a4bc-98f4435a70ab">Main</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6d94f89a-420e-4999-9632-ba140e9cc0aa">
                                <link xl:href="http://snomed.info/id/63161005" xl:show="new">G-A332</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b4708f1-a9ae-4387-86ed-2f826eadd261">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205225" xl:show="new">C0205225</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc084369-0105-4024-89a4-176a06af70af">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f683ff4-ecc5-45c7-8afd-c680603f0159">
                                <link xl:href="http://snomed.info/id/255561001" xl:show="new">255561001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_42ffa89a-6969-4287-ab3e-508bd52e05fa">Medial</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c7f19ea-6381-43be-83ce-352a53d5c839">
                                <link xl:href="http://snomed.info/id/255561001" xl:show="new">R-404D5</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5afb2f4-baf0-4639-bb90-73a568024b4e">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205098" xl:show="new">C0205098</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Middle</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0444598" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0444598</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c559c564-323c-43cf-ac06-10866c19afc8">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61c799a6-36f8-4801-8982-b368277a5b68">
                                <link xl:href="http://snomed.info/id/24028007" xl:show="new">24028007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dce4b605-8944-4765-92e8-dc9e11f04b41">Right</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d7fe50b-331f-4e4e-abdf-2d374b8f0f77">
                                <link xl:href="http://snomed.info/id/24028007" xl:show="new">G-A100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed7d2b08-d5fb-4765-9f49-10193a5b25e2">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205090" xl:show="new">C0205090</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38d90a82-baad-473f-ab4f-d2200c17bc1e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_890152c7-71d9-4b42-a6d7-3c3fdc0a0106">
                                <link xl:href="http://snomed.info/id/264217000" xl:show="new">264217000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_703fa5f5-defe-4c6a-92f3-00605d87a2ad">Superior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_792822bc-0ffd-41ba-a19a-2c89325820d5">
                                <link xl:href="http://snomed.info/id/264217000" xl:show="new">R-42191</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03fab933-74fc-4f51-b7a4-d7f251b0c062">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1282910" xl:show="new">C1282910</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        <section label="CID 12281" status="3" xml:id="sect_CID_12281">
            <title>Cardiac Ultrasound Target Site Modifiers</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c38e0a39-3e0a-401e-85b3-3e4e6803adb6">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12281.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_12281.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_12281.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.861.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1771317e-a705-4cc3-9b41-ba9d9bc2b3f7">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b880086f-41a8-4c99-ae07-c68c187d0df0">
                            <emphasis role="bold"><emphasis role="strikethrough">20160405</emphasis><emphasis role="underline">20190524</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_bc3f3e06-a0df-4c9b-813a-c6c4b816b99e">
                            <emphasis role="bold">1.2.840.10008.6.1.861</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 12281" rules="all" xml:id="table_CID_12281">
                <caption>Cardiac Ultrasound Target Site Modifiers</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_239f777b-7c5b-4c14-a3c8-b3e29e2fd4cb">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8538a61c-bb08-4943-9d10-7e40879c68e4">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2394fe76-97e7-44a0-a28c-d29552099b9c">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_201aa0fa-516c-463d-a332-fb6fdf9a68d8">
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2e4506b-c04c-4d6c-ac0c-d340f5394c85">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e90e278b-656a-46fb-80c4-b16eca27530c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61c0bc19-067d-4de5-a358-f7946c483210">
                                <link xl:href="http://snomed.info/id/49370004" xl:show="new">49370004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5aab8250-c704-4044-bd7c-edbfb760e885">Lateral</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6c1c6e8-af9c-47da-a0af-f4c9d3d53b4a">
                                <link xl:href="http://snomed.info/id/49370004" xl:show="new">G-A104</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0f881dbc-c690-42d2-a9fc-54b195a27008">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205093" xl:show="new">C0205093</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_274afda1-277a-485d-b807-1077e32f5909">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_212b637f-7e54-47e7-9274-0991c29335d4">
                                <link xl:href="http://snomed.info/id/255561001" xl:show="new">255561001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e28e9f77-a537-4222-ab43-4b3721ab35c8">Medial</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee88dc97-78b8-48ca-9e95-bca3b72539fa">
                                <link xl:href="http://snomed.info/id/255561001" xl:show="new">R-404D5</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76bf5db3-611a-44e9-8b11-6405623c02b7">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205098" xl:show="new">C0205098</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ab09e53-c545-414a-8587-9398e34d6f9f"><emphasis role="bold"><emphasis role="strikethrough">SRT</emphasis><emphasis role="underline">NCIt</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b99e673-0ad2-4cab-bf20-f7c0aa882a95">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fca8581b-ae1b-462f-b67c-2a5158f50bbc">Middle</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_654e3fcf-ecd4-4a50-85a7-b443beb63c19">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">R-4081A</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_923af747-a30a-4890-9ad4-1d16df4a8385">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C2939193" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">C2939193</emphasis></emphasis></link>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0444598" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0444598</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4bd8675-fe8f-4512-ab0b-a9a51f6de0df">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e950105-3ed7-46db-8abd-244d528c5c38">
                                <link xl:href="http://snomed.info/id/255549009" xl:show="new">255549009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f45714e8-ad5e-48cb-81e7-38a2ad2a460e">Anterior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6756cef2-3cd9-4e36-9bc8-6a2bcb6978f7">
                                <link xl:href="http://snomed.info/id/255549009" xl:show="new">R-404CC</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57bf64f3-cdbe-4808-814d-5f5d6be798b8">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1704448" xl:show="new">C1704448</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf742145-ce85-4c07-bca0-74904eebab6a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b50faaac-2256-4ec9-bcf3-3df06acce580">
                                <link xl:href="http://snomed.info/id/255551008" xl:show="new">255551008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bec9491d-d275-4ffc-ab9c-c937c01ca9c5">Posterior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d7f4654-dad1-4341-8b54-0e5105132c25">
                                <link xl:href="http://snomed.info/id/255551008" xl:show="new">R-404CE</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4bb1c4c7-a98c-4a1e-9b63-31c4d00aa537">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205095" xl:show="new">C0205095</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62cb8f0f-b738-45fe-89d4-3d642d8bee06">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b7bfcb7-3f2f-4460-a275-72d18c62564e">
                                <link xl:href="http://snomed.info/id/261089000" xl:show="new">261089000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ef157e8-73ec-4511-91d0-0a24923f1c38">Inferior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_498e389a-be93-4c9b-9914-63b960436dba">
                                <link xl:href="http://snomed.info/id/261089000" xl:show="new">R-4094A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31988a3e-1a8a-40d5-98e1-2459644eeb9f">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0542339" xl:show="new">C0542339</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98e25fb7-09e6-461e-8d35-6839117296e3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64856b1b-88de-427a-9a65-fdeb4642c5c4">
                                <link xl:href="http://snomed.info/id/46053002" xl:show="new">46053002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0b3c1127-40ec-4754-8ce7-b46f50049d1a">Distal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa9bfaa1-0dbf-48de-8952-8a50f8004f5d">
                                <link xl:href="http://snomed.info/id/46053002" xl:show="new">G-A119</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d6c42d6e-2774-4f8f-8c42-da2b92a39aaf">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205108" xl:show="new">C0205108</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_382fce96-776b-467e-a6e6-6853dd864f06">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c815450-943f-4754-ba73-7fef0f248ecc">
                                <link xl:href="http://snomed.info/id/40415009" xl:show="new">40415009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_28d7e16d-937f-4a34-a06a-c6badb301611">Proximal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06f7b9aa-8d7e-481e-b358-03d2f6bf1089">
                                <link xl:href="http://snomed.info/id/40415009" xl:show="new">G-A118</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19edff28-3b30-420e-b71f-3677301e71bc">
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205107" xl:show="new">C0205107</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 212" status="3" xml:id="sect_CID_212">
            <title>Generic Anatomic Location Modifiers</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_212.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_212.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_212.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1287.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">20190524</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1287</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 212" rules="all" xml:id="table_CID_212">
                <caption>Generic Anatomic Location Modifiers</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">SNOMED-RT ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255549009" xl:show="new">255549009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Anterior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255549009" xl:show="new">R-404CC</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205094" xl:show="new">C0205094</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/26216008" xl:show="new">26216008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Central</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/26216008" xl:show="new">G-A110</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205099" xl:show="new">C0205099</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/46053002" xl:show="new">46053002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Distal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/46053002" xl:show="new">G-A119</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205108" xl:show="new">C0205108</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/261089000" xl:show="new">261089000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Inferior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/261089000" xl:show="new">R-4094A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205104" xl:show="new">C0205104</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/49370004" xl:show="new">49370004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Lateral</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/49370004" xl:show="new">G-A104</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205093" xl:show="new">C0205093</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255561001" xl:show="new"><emphasis role="bold"><emphasis role="underline">255561001</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Medial</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255561001" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-404D5</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205098" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0205098</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_130290" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">130290</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Median</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Middle</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0444598" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0444598</emphasis></emphasis></link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/103342007" xl:show="new">103342007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Mid-longitudinal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/103342007" xl:show="new">G-A188</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0522490" xl:show="new">C0522490</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255551008" xl:show="new">255551008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Posterior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/255551008" xl:show="new">R-404CE</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205095" xl:show="new">C0205095</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/40415009" xl:show="new">40415009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Proximal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/40415009" xl:show="new">G-A118</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C0205107" xl:show="new">C0205107</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/264217000" xl:show="new">264217000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Superior</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/264217000" xl:show="new">R-42191</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C1282910" xl:show="new">C1282910</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            
            
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_130290"><emphasis role="bold"><emphasis role="underline">130290</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Median</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Towards the mid-sagittal plane of the body.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="E" status="1" xml:id="chapter_E">
      <title>French Language Meanings of Selected Codes Used in the DCMR (Normative)</title>
      <table frame="box" label="E-1" rules="all" xml:id="table_E-1">
         <caption>French Language Meanings of Selected Codes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_090f9188-a249-49a9-82d7-0a9851688cea">
                     <emphasis role="bold">Coding Scheme Designator</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_238a2497-22be-41cd-af6f-3df3a3689ee9">
                     <emphasis role="bold">Coding Scheme Version</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0467362d-e7f7-4d4d-a1aa-8a096bbb1a7b">
                     <emphasis role="bold">Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b2226261-7655-49c3-a0bc-c0295572a723">
                     <emphasis role="bold">Code Meaning English Language</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_036bfbde-f73b-46a0-883b-c655056c459f">
                     <emphasis role="bold">Code Meaning French Language</emphasis>
                  </para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                   <para xml:id="para_3a022115-f40f-44a1-bf61-6791380d7838"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">DCM</emphasis></emphasis></para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_62a0da21-e8e5-4bed-8479-69ead8cab927"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_bcdd03dc-7f0b-41f1-96b2-bb5ac87c451d">
                      <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="strikethrough"><emphasis role="underline">260528009</emphasis></emphasis></link>
                      <link linkend="DCM_130290" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">130290</emphasis></emphasis></link>
                  </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_90e4a2c0-fd3d-45bb-9d05-1a554fca04e6">Median</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_319e32d3-3fa2-4b89-bc6c-1219bba99daa" xml:lang="fr">Médian</para>
               </td>
            </tr>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0acc1276-703f-4598-a20d-988ee94e621f"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">NCIt</emphasis></emphasis></para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_91dfee04-9dc8-4534-8362-a05f642c9844"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_53675c4e-a9da-4302-beb4-eba01f1fdbbc">
                      <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5aba6fd6-83a5-4704-997e-92d78b26469e">Middle</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_40ba2a5c-7428-4dc2-b745-c2a7c2e882a6" xml:lang="fr">Milieu</para>
               </td>
            </tr>
                </tbody>
            </table>
        </section>
        
        <section label="F" status="1" xml:id="chapter_F">
      <title>Japanese Language Meanings of Selected Codes Used in The DCMR (Normative)</title>
      <table frame="box" label="F-1" rules="all" xml:id="table_F-1">
         <caption>Japanese Language Meanings of Selected Codes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0a2ebcad-b99b-4ed7-abb6-1044db248781">
                     <emphasis role="bold">Coding Scheme Designator</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_72126191-efa7-4aef-81a7-3e4ab94ce310">
                     <emphasis role="bold">Coding Scheme Version</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d41965ca-6e67-4f76-80aa-514d54300e66">
                     <emphasis role="bold">Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_799e56ce-9686-474e-98c4-b95f6d408b86">
                     <emphasis role="bold">Code Meaning English Language</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ed2ca850-ba13-4e52-b40a-dc809e58b83f">
                     <emphasis role="bold">Code Meaning Japanese Language</emphasis>
                  </para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_73bdeb60-c295-47a7-ac1e-54f17616fcf1"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis><emphasis role="underline">NCIt</emphasis></emphasis></para>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_270bbda6-f1ad-45b0-b868-ee395d8e3993"/>
               </td>
               <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b412507f-ae20-4402-aad5-416129725ece">
                      <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new"><emphasis role="bold"><emphasis role="underline">C25569</emphasis></emphasis></link>
                            </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_6b9ff4a8-5bd4-4c21-aca1-a0da0d10e00a">Middle</para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5f01bf31-e561-45e1-8330-26f8f5455cd9" xml:lang="ja"><emphasis role="bold"><emphasis role="strikethrough">中央の</emphasis><emphasis role="underline">中間</emphasis></emphasis></para>
               </td>
            </tr>
         </tbody>
      </table>
   </section>
        <section label="G" status="1" xml:id="chapter_G">
      <title>English Code Meanings of Selected Codes (Normative)</title>
      <table frame="box" label="G-1" rules="all" xml:id="table_G-1">
         <caption>English Code Meanings of Selected Codes</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_37309cee-1fc3-4a9c-94ea-8ef8cdbaa5bb">
                     <emphasis role="bold">Coding Scheme Designator</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_149479f8-a549-4f0a-a8ed-d301cfbe996b">
                     <emphasis role="bold">Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a650cc21-6a0a-4bce-8340-4c616facbb36">
                     <emphasis role="bold">Code Meaning</emphasis>
                  </para>
               </th>
            </tr>
         </thead>
         <tbody>
            <tr valign="top">
               <td align="center" colspan="1" rowspan="2">
                  <para xml:id="para_8b831fec-a9b3-4d21-ad60-60591735ca8f"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
               </td>
               <td align="center" colspan="1" rowspan="2">
                  <para xml:id="para_92786fca-dd71-4a5c-97dc-cf20f0cb9be3">
                      <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                            </para>
               </td>
               <td align="left" colspan="1" rowspan="1">
                   <para xml:id="para_6a239f60-e42e-4e6b-a482-0a4d87238ee4"><emphasis role="bold"><emphasis role="strikethrough">Median</emphasis></emphasis></para>
               </td>
            </tr>
            <tr valign="top">
               <td align="left" colspan="1" rowspan="1">
                   <para xml:id="para_dc66e89b-df37-4af3-8f1a-937d5fd0a3aa"><emphasis role="bold"><emphasis role="strikethrough">Middle</emphasis></emphasis></para>
               </td>
            </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="2">
                     <para xml:id="para_101f8f80-d117-4c0e-90f7-088b6f624e07"><emphasis role="bold"><emphasis role="strikethrough">SCT</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="2">
                     <para xml:id="para_82f84b1b-cb4b-49f0-8c4a-6cd0a4cc733f">
                         <link xl:href="http://snomed.info/id/103342007" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">103342007</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_6dfdc5a1-d0c6-4673-b84b-eff46ac05430"><emphasis role="bold"><emphasis role="strikethrough">Mid-Longitudinal</emphasis></emphasis></para>
                 </td>
             </tr>
             <tr valign="top">
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_017ed7c0-706e-487b-871c-88062c52cec2"><emphasis role="bold"><emphasis role="strikethrough">Mid</emphasis></emphasis></para>
                 </td>
             </tr>
         </tbody>
      </table>
   </section>
        
        <section label="J" status="1" xml:id="chapter_J">
      <title>SNOMED Retired Codes</title>
      <table frame="box" label="J-1" rules="all" xml:id="table_J-1">
         <caption>SNOMED Codes Retired from DICOM Use</caption>
         <thead>
            <tr valign="top">
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ba15f948-561c-4cf6-a7c8-451b15b4d601">
                     <emphasis role="bold">Retired Code Value</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_64a0b043-59fc-410d-a39e-81671a662f04">
                     <emphasis role="bold">Code Meaning</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a1e2c06a-1e64-4fd5-9ffb-0da12a76aeb2">
                     <emphasis role="bold">Replacement Code</emphasis>
                  </para>
               </th>
               <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_246a7171-2a92-45ac-80b1-7ed33ffc877b">
                     <emphasis role="bold">Notes</emphasis>
                  </para>
               </th>
            </tr>
         </thead>
         <tbody>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0aa91b0e-93f7-4dc5-87c1-df409d18301d">G-A109</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ef765ee9-1be0-417a-904d-57ae2dfe8ec3">Medial</para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_7b471dc7-a16a-46e4-b686-201ee3a8dbda">
                         <link xl:href="http://snomed.info/id/255561001" xl:show="new">255561001</link>
                     </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b4982466-0ce1-430b-8978-2f08d2f6c5a1">Replacement code has meaning of "Medial (qualifier value)".</para>
                     <para xml:id="para_71010027-dbb0-4095-87e8-98ed717f5f70">Retired code is inactive in SNOMED CT (Ambiguous).</para>
                 </td>
             </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5ef2de13-5df3-4e36-bf75-f07c6cc3088e">G-A109</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_487888eb-3f72-4813-9ec5-c569f76ff984">Median</para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e875c4a9-7e1b-4a98-8aeb-e585068bc701">
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_9e5a7866-08cc-4b9e-b70c-eaf76ed0c891"><emphasis role="bold"><emphasis role="strikethrough">Replacement code has meaning of "Median (qualifier value)".</emphasis><emphasis role="underline">No replacement SNOMED code exists.</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline"><link linkend="DCM_130290" xrefstyle="select: nopage">(130290, DCM. "Median")</link> may be used instead.</emphasis></emphasis></para>
                     <para xml:id="para_08996dc0-ec2c-4d62-ac21-fe99d0dea8fb">Retired code is inactive in SNOMED CT (Ambiguous).</para>
                 </td>
             </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f925971c-6f6b-47ee-a8ac-42482d2c457e">G-A109</para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_22d5211a-d568-4284-8e46-ce3b454c1d18">Middle</para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_a458e5bd-f6ea-4091-9146-7a0d54973d5e">
                         <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="strikethrough">260528009</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_e60db308-4cf2-4f0d-b928-c13274f32e74"><emphasis role="bold"><emphasis role="strikethrough">Replacement code has meaning of "Median (qualifier value)".</emphasis><emphasis role="underline">No replacement SNOMED code exists.</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline"><link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new">(C25569, NCIt, "Middle")</link> may be used instead.</emphasis></emphasis></para>
                     <para xml:id="para_53fae8c9-25f0-41ca-9088-109fc50c1757">Retired code is inactive in SNOMED CT (Ambiguous).</para>
                 </td>
             </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para>
                                <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-4081A</emphasis></emphasis></link>
                            </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Median</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para/>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">No replacement SNOMED code exists.</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline"><link linkend="DCM_130290" xrefstyle="select: nopage">(130290, DCM. "Median")</link> may be used instead.</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline">Retired code is ambiguous since it has synomyms of "middle" and "median".</emphasis></emphasis></para>
                 </td>
             </tr>
             <tr valign="top">
                 <td align="center" colspan="1" rowspan="1">
                     <para>
                         <link xl:href="http://snomed.info/id/260528009" xl:show="new"><emphasis role="bold"><emphasis role="underline">R-4081A</emphasis></emphasis></link>
                     </para>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Middle</emphasis></emphasis></para>
                 </td>
                 <td align="center" colspan="1" rowspan="1">
                     <para/>
                 </td>
                 <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">No replacement SNOMED code exists.</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline"><link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C25569" xl:show="new">(C25569, NCIt, "Middle")</link> may be used instead.</emphasis></emphasis></para>
                     <para><emphasis role="bold"><emphasis role="underline">Retired code is ambiguous since it has synomyms of "middle" and "median".</emphasis></emphasis></para>
                 </td>
             </tr>
             
         </tbody>
      </table>
   </section>
        