<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1824</title>
    <subtitle>Add more PMSA Targeting Radiopharmaceuticals</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2019/01/234</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
           <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>Roberto Maass-Moreno</para>
                 <para><link xl:href="mailto:rmaass@cc.nih.gov"/></para></td>
           </tr>
           <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2018/05/10</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1824</para></td>
            </tr>
            <tr>
               <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add more PMSA Targeting Radiopharmaceuticals</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16 2018e</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                   <para>A code is need for F18 prostate-specific membrane antigen (PSMA).</para>
               <para>CP1741 added only a Ga68 agent.</para>
               <para>There are also non-PET PSMA agents.</para>
                   
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        <section label="CID 25" status="3" xml:id="sect_CID_25">
         <title>Radiopharmaceuticals</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_88b043b9-c459-46b8-8100-6df018e3a17e">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_25.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_25.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_25.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.17.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_7d6c0511-f8b7-4435-bbca-9197e3906c1c">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_c7608099-4037-4634-9e20-602f9fc5138d">
                            <emphasis role="bold"><emphasis role="strikethrough">20160314</emphasis><emphasis role="underline">20190124</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_594b7096-e586-4616-bd69-7fbfde9afae3">
                     <emphasis role="bold">1.2.840.10008.6.1.17</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 25" rules="all" xml:id="table_CID_25">
            <caption>Radiopharmaceuticals</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_8865e443-5043-44dd-9744-0ec44b4b3deb">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f16d3311-799a-4055-846b-0950f8d8253d">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c3098be5-74fe-4656-8e31-7cbfc4d2879c">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_02463cd1-4699-41ea-8e97-7dc9ac11a621">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_536ae27d-5ea9-4e6e-bb60-f7d70d7906d3">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_09759726-71dd-4cbc-a5dd-d8535aeb906e">
                        <emphasis role="bold"><emphasis role="strikethrough">Trade name (Informative)</emphasis><emphasis role="underline">Other Names</emphasis></emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>

 
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_d4f8ca7d-2049-46d1-a999-d67c3abb6780">SRT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_09c598e8-1d75-446a-84ea-84ce3086e6c7">
                        <link xl:href="http://snomed.info/id/447126009" xl:show="new">C-163BA</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_ca506c41-f38c-4cd2-a2fd-67f8a9474af8">Technetium^99m N-pyridoxyl-5-methyltryptophan</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_0bea3793-a6c8-46b7-a476-51ad78bcfbcd">
                        <link xl:href="http://snomed.info/id/447126009" xl:show="new">447126009</link>
                     </para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_9973f09d-80d9-4f25-8b56-e489d88676eb">
                        <link xl:href="http://uts.nlm.nih.gov/metathesaurus.html?cui=C3897370" xl:show="new">C3897370</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_b8e5bb9d-eb33-4ee5-8048-134771bb3c76">Hepatimage</para>
                  </td>
               </tr>
               
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C116887" xl:show="new"><emphasis role="bold"><emphasis role="underline">C116887</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">Technetium^99m Trofolastat</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C3899042" xl:show="new">C3899042</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">MIP 1404</emphasis></emphasis></para>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>
       
                    <section label="CID 4021" status="3" xml:id="sect_CID_4021">
         <title>PET Radiopharmaceutical</title>
         <variablelist spacing="compact">
            <varlistentry>
               <term>
                  <emphasis role="bold">Resources:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_7acfb90b-1332-42e6-a333-59cca3e4b25e">
                     <emphasis role="bold">
                        <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4021.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_4021.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_4021.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.305.xml" xl:show="new">IHE SVS XML</link>
                     </emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Type:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_975ea8ef-40ed-48a3-9c64-59e5093f6222">
                     <emphasis role="bold">Extensible</emphasis>
                  </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">Version:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_3aaadcf2-0d4e-40c2-9732-208545d28a7d">
                            <emphasis role="bold"><emphasis role="strikethrough">20180327</emphasis><emphasis role="underline">20190124</emphasis></emphasis>
                        </para>
               </listitem>
            </varlistentry>
            <varlistentry>
               <term>
                  <emphasis role="bold">UID:</emphasis>
               </term>
               <listitem>
                  <para xml:id="para_bf9fdd09-f9be-4af6-a5d9-ec24078f6729">
                     <emphasis role="bold">1.2.840.10008.6.1.305</emphasis>
                  </para>
               </listitem>
            </varlistentry>
         </variablelist>
         <table frame="box" label="CID 4021" rules="all" xml:id="table_CID_4021">
            <caption>PET Radiopharmaceutical</caption>
            <thead>
               <tr valign="top">
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_10c25d91-27c7-4d01-8385-d861df10f3e9">
                        <emphasis role="bold">Coding Scheme Designator</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_91b0c5d5-92b3-4d5a-bbf8-82648fa7f2f4">
                        <emphasis role="bold">Code Value</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_5e15bdd4-8016-4671-943b-9eb55cc94f74">
                        <emphasis role="bold">Code Meaning</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_ba3d73d7-fa36-4c62-9ff4-fbe923c664cd">
                        <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_c644999a-3fd9-43d8-a332-2a157201aeca">
                        <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                     </para>
                  </th>
                  <th align="center" colspan="1" rowspan="1">
                     <para xml:id="para_50d15cd9-82b5-4c18-a066-1a071bfe4e04">
                        <emphasis role="bold">Other Names</emphasis>
                     </para>
                  </th>
               </tr>
            </thead>
            <tbody>
               
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C96234" xl:show="new"><emphasis role="bold"><emphasis role="underline">C96234</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">DCFBC F^18^</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C2604127" xl:show="new"><emphasis role="bold"><emphasis role="underline">C2604127</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">N-​[N-​[(S)-​1,3-​dicarboxypropyl]​carbamoyl]​-​4-​fluorobenzyl-​l-​cysteine F^18^</emphasis></emphasis></para>
                  </td>
               </tr>
               
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C116352" xl:show="new"><emphasis role="bold"><emphasis role="underline">C116352</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">DCFPyL F^18^</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C3492634" xl:show="new"><emphasis role="bold"><emphasis role="underline">C3492634</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">2-​(3-​(1-​carboxy​-5-​[(6-​fluoro-​pyridine-​3-​carbonyl​)-​amino​]-​pentyl​)-​ureido)​-​pentanedioic acid F^18^</emphasis></emphasis></para>
                  </td>
               </tr>
              
               
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link linkend="DCM_126758" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">126758</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">PSMA-1007 F^18^</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>

               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_b58f4085-e7f3-4ee3-b493-2ddde5e47f7d">NCIt</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_e36bc5c8-f834-40a6-a795-b6daa76cddd0">
                        <link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C118961" xl:show="new">C118961</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_c137b5a7-64e6-4391-95ba-d10f9db3d784">PSMA<emphasis role="bold"><emphasis role="underline">-11</emphasis></emphasis> Ga^68^</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_2635c428-7898-4c90-b203-394196b62a81"/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para xml:id="para_f3a71b8e-705b-451c-9f3c-6e45107c968d">
                        <link xl:href="https://uts.nlm.nih.gov/metathesaurus.html?cui=C3899042" xl:show="new">C3899042</link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_28715ab4-d045-4939-b39e-d220950c9d8d">Glu‑NH‑CO‑NH‑Lys(Ahx)-HBED‑CC Ga^68^</para>
                  </td>
               </tr>
               
               <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para>
                        <link linkend="DCM_126759" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">126759</emphasis></emphasis></link>
                     </para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para><emphasis role="bold"><emphasis role="underline">PSMA-617 Ga^68^</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                     <para/>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                     <para/>
                  </td>
               </tr>
            </tbody>
         </table>
      </section>


        
      
       <section>
          <table rules="all" frame="box" label="D-1">
             <caption>DICOM Controlled Terminology Definitions</caption>
             <thead>
                <tr valign="top">
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Code Value</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Code Meaning</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Definition</emphasis>
                      </para>
                   </th>
                   <th align="center" colspan="1" rowspan="1">
                      <para>
                         <emphasis role="bold">Notes</emphasis>
                      </para>
                   </th>
                </tr>
             </thead>
             <tbody>
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126758"><emphasis role="bold"><emphasis role="underline">126758</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">PSMA-1007 F^18^</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">A PET radiotracer targeting PMSA used for prostate cancer imaging.</emphasis></emphasis></para>
                      <para><emphasis role="bold"><emphasis role="underline">See Giesel FL, Hadaschik B, Cardinale J, Radtke J, Vinsensia M, Lehnert W, et al. F-18 labelled PSMA-1007: biodistribution, radiation dosimetry and histopathological validation of tumor lesions in prostate cancer patients. Eur J Nucl Med Mol Imaging. 2017 Apr 1;44(4):678–88. doi:10.1007/s00259-016-3573-4.
                         <link xl:href="http://link.springer.com/article/10.1007/s00259-016-3573-4"/></emphasis></emphasis></para></td>
                   <td align="left" colspan="1" rowspan="1">
                      <para/>
                   </td>
                </tr>
                
                <tr valign="top">
                   <td align="center" colspan="1" rowspan="1">
                      <para xml:id="DCM_126759"><emphasis role="bold"><emphasis role="underline">126759</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">PSMA-617 Ga^68^</emphasis></emphasis></para>
                   </td>
                   <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">A PET radiotracer targeting PMSA used for prostate cancer imaging.</emphasis></emphasis></para>
                      <para><emphasis role="bold"><emphasis role="underline">See Afshar-Oromieh A, Hetzheim H, Kratochwil C, Benesova M, Eder M, Neels OC, et al. The Theranostic PSMA Ligand PSMA-617 in the Diagnosis of Prostate Cancer by PET/CT: Biodistribution in Humans, Radiation Dosimetry, and First Evaluation of Tumor Lesions. J Nucl Med. 2015 Nov 1;56(11):1697–705. doi: 10.2967/jnumed.115.161299.
                         <link xl:href="http://jnm.snmjournals.org/content/56/11/1697"/></emphasis></emphasis></para></td>
                   <td align="left" colspan="1" rowspan="1">
                      <para/>
                   </td>
                </tr>
                
             </tbody>
          </table>
       </section>
      
      
      


    </chapter>
</book>