    <title>CP-1763</title>
  <subtitle>Source Instance Sequence for Images in Encapsulated Document IODs</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/09/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top">
                  <para>Don Van Syckle <link xl:href="mailto:don.van@dvsconsult.com"/></para>
                  <para>Régis Deshayes <link xl:href="mailto:regis.deshayes@zeiss.com"/></para>
                  <para>Patrick Nast <link xl:href="mailto:patrick.nast@zeiss.com"/></para>
                  <para>WG9</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2018/01/22</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1763</para></td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Source Instance Sequence for Images in Encapsulated Document IODs</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.16 2018c</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>In Eye Care, devices generate PDF reports that are stored/displayed to users. This is a common feature that has been implemented for years by many vendors. These devices create reports often based on OP or OPT images and they have used Source Instance Sequence to reference those images, since the IOD did not contain Source Image Sequence.</para>
                  <para>Changes introduced by CP1681 break Eye Care implementations and break DICOM backward compatibility of the Encapsulated PDF IOD.</para>
                  <para>Specifically:</para>
                  <orderedlist>
                    <listitem>
                      <para>CP1575 (Add Purpose of Reference for Source Instance Sequence) and CP1559 (Add the General Reference Module) were simultaneously integrated in the standard in release 2016d.</para>
                    </listitem>
                    <listitem>
                      <para>Both General Reference module and Encapsulated Document module were then assigned the same Defined CID 7013 Source Instance Purpose of Reference,
                        which included (121324, DCM, "Source Image").</para>
                    </listitem>
                    <listitem>
                      <para>The definition of the Source Instance Sequence is different in the two modules: it does not exclude image composite SOP instances in the Encapsulated Document Module - the older definition - whereas it does exclude image composite SOP instances in the General Reference Module.</para>
                    </listitem>
                    <listitem>
                      <para>CP1681 renamed CID 7013 to “Non-Image Source Instance Purposes of Reference” and removed (121324, DCM, "Source Image"),
                        in order to avoid replication of the function of Source Image Sequence.</para>
                    </listitem>
                  </orderedlist>
                  <para>Now that Source Instance Sequence and CID 7013 no longer include images, Eye Care devices that produce Encapsulated Document IODs appear non-compliant.</para>
          <para>Create a new context group referenced from the Encapsulated Document Module that includes images, and note the inconsistency is for backward compatibility.</para>
                    <para>This CP was already incorporated into 2018b as part of Supplement 205 Final Text, which specifically referenced this CP; only minor editorial changes to the note text remain.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
      <section label="A.19.4" status="3" xml:id="sect_A.19.4">
        <title>RT Structure Set IOD Content Constraints</title>
        <para xml:id="para_5d2e536b-f6f6-4e8b-8999-7c619c17ead4">The Defined CID for Purpose of Reference Code Sequence (0040,A170) within Source Instance Sequence (0042,0013) in the General Reference Module shall be
          <xref linkend="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle nopage"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle"/>-->.</para>
      </section>
      
      <section label="A.51.4" status="3" xml:id="sect_A.51.4">
        <title>Segmentation IOD Content Constraints</title>
        <para xml:id="para_e912144a-88b2-43b9-8cc7-bc9fa4eea774">...</para>
        <para xml:id="para_61a37ab1-94da-46d1-8cf7-7735bd0dc51b">The Defined CID for Purpose of Reference Code Sequence (0040,A170) within Source Instance Sequence (0042,0013) in the General Reference Module shall be
          <xref linkend="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle nopage"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle"/>-->.</para>
      </section>
      
      <section label="A.57.4" status="3" xml:id="sect_A.57.4">
        <title>Surface Segmentation IOD Content Constraints</title>
        <para xml:id="para_78a09c72-63b1-489c-bef8-2b53a6276250">The Defined CID for Purpose of Reference Code Sequence (0040,A170) within Source Instance Sequence (0042,0013) in the General Reference Module shall be
          <xref linkend="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle nopage"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle"/>-->.</para>
      </section>
      
      <section label="C.12.4" status="3" xml:id="sect_C.12.4">
        <title>General Reference Module</title>
        <table frame="box" label="C.12-10" rules="all" xml:id="table_C.12-10">
          <caption>General Reference Module Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_9050c9fd-7eda-4001-8b6e-1129c0a431de">Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_9b10aae6-46fb-4b32-a101-0aa4c10601a9">Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_b1ef16d8-f1d5-462c-8f4f-4fd77c1edfc0">Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_1c396602-83bb-4d9f-b546-54d596289c39">Attribute Description</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_99d8949c-5229-40f4-a7bd-578eb2784a80">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_ca4f8d0a-c30b-48a4-a7be-8b804132e130">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_1078d0b9-ce30-4aae-bb0f-dee9224a1853">...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_92e1396a-c970-4997-b1e5-f1f82abc5c12">...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c4f3f599-0bce-4017-9835-beaa2091e751">Source Image Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_4ef558d7-3e59-43b6-82bb-2a5756656953">(0008,2112)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_6e9d55d6-bf18-4fad-abbe-b5e3d9fca673">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_af74d55c-cc63-466d-98d3-8c924a604f8e">The set of Image SOP Class/Instance pairs of the Images that were used to derive this Image.</para>
                <para xml:id="para_7ef45d93-9f01-42a1-b9ca-1e2540605778">One or more Items are permitted in this Sequence.</para>
                <para xml:id="para_19837571-595c-453e-be64-f0880dfe76f8">See <xref linkend="sect_C.12.4.1.2" xrefstyle="select: label"/> for further explanation.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_291c0657-775a-4aea-ac7e-c93ad176dc1e">
                  <emphasis role="italic">&gt;Include Table 10-3 "Image SOP Instance Reference Macro Attributes"<!--<xref linkend="table_10-3" xrefstyle="select: label quotedtitle"/>-->
                  </emphasis>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c12df47c-dc38-447e-87ca-0fe26000e7d5"/>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c255e4b1-fca8-4aac-934e-57cedbe75eae">&gt;Purpose of Reference Code Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_64c2d075-ca4b-474f-bd42-3d813a744f4d">(0040,A170)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_40f7f3a6-f362-4985-bd43-751396103655">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_bb73913c-057f-42a6-b93e-8d00cb98a845">Describes the purpose for which the reference is made, that is what role the source image or frame(s) played in the derivation of this image.</para>
                <para xml:id="para_f5ddda73-dc64-4ac6-9d06-48d3ee1bd463">Only a single Item is permitted in this Sequence.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_4d778ca4-b312-4cf4-9962-f6bc3044a0c8">
                  <emphasis role="italic">&gt;&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
                  </emphasis>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_f99e237f-73f7-4cf6-9f6e-b15d834d8ec2">
                  <emphasis role="italic">Defined <xref linkend="sect_CID_7202" xrefstyle="select: labelnumber quotedtitle nopage"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7202" xrefstyle="select: labelnumber quotedtitle"/>-->.</emphasis>
                </para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_0ef03779-ffcb-4886-a996-12abb1ac4540">&gt;Spatial Locations Preserved</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_47c1f944-4204-469b-99d9-5d07974de2dd">(0028,135A)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_7a897fe2-8ae7-4ff6-b2e1-dce5e04a9093">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_1ebf595f-0ecb-4598-b007-cf9cc03fc9c4">The extent to which the spatial locations of all pixels are preserved during the processing of the source image that resulted in the current image</para>
                <variablelist spacing="compact">
                  <title>Enumerated Values:</title>
                  <varlistentry>
                    <term>YES</term>
                    <listitem>
                      <para xml:id="para_55b98087-0481-4b63-b7ff-21f2634606e0"/>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>NO</term>
                    <listitem>
                      <para xml:id="para_a68435b8-d5e9-474c-b3f8-d8e5e10b1fcd"/>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>REORIENTED_ONLY</term>
                    <listitem>
                      <para xml:id="para_32ef595d-7af5-4643-b879-7066198ea1a8">A projection radiograph that has been flipped, and/or rotated by a multiple of 90 degrees</para>
                    </listitem>
                  </varlistentry>
                </variablelist>
                <note>
                  <orderedlist numeration="arabic">
                    <listitem>
                      <para xml:id="para_9976bb70-d841-4a34-8a47-46d189fa9d3b">This applies not only to images with a known relationship to a 3D space, but also to projection images. For example, a projection radiograph such as a mammogram that is processed by a point image processing operation such as contrast enhancement, or a smoothing or edge enhancing convolution, would have a value of YES for this attribute. A projection radiograph that had been magnified or warped geometrically would have a value of NO for this attribute. A projection radiograph that has been flipped, and/or rotated by a multiple of 90 degrees, such that transformation of pixel locations is possible by comparison of the values of Patient Orientation (0020,0020) would have a value of REORIENTED_ONLY. This attribute is typically of importance in relating images with Presentation Intent Type (0008,0068) values of FOR PROCESSING and FOR PRESENTATION.</para>
                    </listitem>
                    <listitem>
                      <para xml:id="para_2b403f53-2ffb-4cb8-b283-851c3cce981b">When the value of this attribute is NO, it is not possible to locate on the current image any pixel coordinates that are referenced relative to the source image, such as for example, might be required for rendering CAD findings derived from a referenced FOR PROCESSING image on the current FOR PRESENTATION image.</para>
                    </listitem>
                  </orderedlist>
                </note>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_470b5f93-01d2-49fc-925f-8a33f0d8f25a">&gt;Patient Orientation</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_43f532be-01f8-42c9-ae9a-e37d9c263788">(0020,0020)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_3f918f6f-e0b9-4e09-ad6f-3aa551cafaba">1C</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ffb13521-8513-441c-810e-be44a4b89ab4">The Patient Orientation values of the source image.</para>
                <para xml:id="para_185d7df6-01ee-44dc-95ba-28306baeb740">Required if the value of Spatial Locations Preserved (0028,135A) is REORIENTED_ONLY.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_a6ac71d2-cd67-4b62-be50-014d53681350">Source Instance Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_ccf936af-4793-4848-87e1-453a51dc264e">(0042,0013)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_2cc292c7-cbc9-4ee2-b4ca-cffcfaa6a581">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b01ae368-f122-498f-81ad-1e98c8d783ee">The set of non-image composite SOP instances that were used to derive this instance.</para>
                <para xml:id="para_b925b93e-86b4-4322-b074-2cea5a989f62">One or more Items are permitted in this Sequence.</para>
                <para xml:id="para_9bbf43ad-2c9c-44f4-8cf1-5ae619754806">See <xref linkend="sect_C.12.4.1.2" xrefstyle="select: label"/> for further explanation.</para>
               </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_b9464ac4-c1bc-4c50-bdc3-7bd03ca9524c">
                  <emphasis role="italic">&gt;Include Table 10-11 "SOP Instance Reference Macro Attributes"<!--<xref linkend="table_10-11" xrefstyle="select: label quotedtitle"/>-->
                  </emphasis>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_99f3a6a1-5bb9-4834-860f-2b830264ee31"/>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c679f089-ae4f-498c-b159-eaa79e1f21e2">&gt;Purpose of Reference Code Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_1e1f534b-3fe6-4f82-93a6-7de9b03c5a52">(0040,A170)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_29bed6b6-8e7c-43a2-aac6-a85b90458459">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_41b76810-8d01-40ff-b06f-76f9958cc621">Describes the purpose for which the reference is made, that is what role the source instance(s) played in the derivation of this instance.</para>
                <para xml:id="para_24935abf-fef8-44da-ad0c-e430a77d2835">Only a single Item single Item is permitted in this Sequence.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_9f420238-512b-48be-b0b0-9474f2cfb0a0">
                  <emphasis role="italic">&gt;&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
                  </emphasis>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_2c2a8427-9802-4d45-9a46-dbfe2747019f">
                  <emphasis role="italic">Defined <xref linkend="sect_CID_7013" xrefstyle="select: labelnumber quotedtitle nopage"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7013" xrefstyle="select: labelnumber quotedtitle"/>-->.</emphasis>
                </para>
              </td>
            </tr>
          </tbody>
        </table>
        <section label="C.12.4.1" status="4" xml:id="sect_C.12.4.1">
          <title>General Reference Module Attributes</title>
          <section label="C.12.4.1.2" status="5" xml:id="sect_C.12.4.1.2">
            <title>Source Image Sequence</title>
            <para xml:id="para_f9f0bee7-9d85-4b0c-9e33-9d5d738ec062">If an Image is identified to be a Derived Image (see Section C.7.6.1.1.2<!--<xref linkend="sect_C.7.6.1.1.2" xrefstyle="select: label quotedtitle"/>-->), Source Image Sequence (0008,2112) is an optional list of
              source images used to create the Derived image.
              Source Instance Sequence (0042,0013) is an optional list of non-image source instances that were used to create this instance.
              Source Image Sequence (0008,2112) and/or Source Instance Sequence (0042,0013) may be used whether or not there is a description of the way the instance was derived in Derivation Description (0008,2111) or Derivation Code Sequence (0008,9215).</para>
            <para xml:id="para_4c66dce4-2bb1-4aa8-b3a6-2d625d561d2a">Images shall not be referenced by Source Instance Sequence (0042,0013).</para>
            <note>
              <para xml:id="para_33af043f-8aa5-4998-a7e4-0239081dbd04">Multiple Items may be present within Source Image Sequence (0008,2112) and/or Source Instance Sequence (0042,0013), in which case either:</para>
              <orderedlist numeration="loweralpha">
                <listitem>
                  <para xml:id="para_6de9d442-4173-41a8-a896-bc59b9872552">those instance were combined to make the derived instance (e.g., multiple source images to make an MPR or MIP), or</para>
                </listitem>
                <listitem>
                  <para xml:id="para_97c3ea55-dcc0-4207-a316-b5a63d5ef0cb">each of the items represents a step in the successive derivation of an instance (e.g., when an image has had successive lossy compression steps applied to it), </para>
                </listitem>
                <listitem>
                  <para xml:id="para_4cbfd9e3-30bd-47c5-8847-6f69178536e0">some combination of the above.</para>
                </listitem>
              </orderedlist>
              <para xml:id="para_a9cabddf-cf34-4250-ae0c-f9026aaf0ec1">The Purpose of Reference Code Sequence (0040,A170) and the Attributes within the referenced instances themselves may be used to determine the history of the derivation, which is not otherwise explicitly specified.</para>
            </note>
          </section>
        </section>
      </section>
      
      <section label="C.24.2" status="3" xml:id="sect_C.24.2">
        <title>Encapsulated Document Module</title>
        <table frame="box" label="C.24-2" rules="all" xml:id="table_C.24-2">
          <caption>Encapsulated Document Module Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_44998267-ad2b-4859-ae25-ce1cfa0061fa">Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_4bb25235-6a0d-4080-af36-40d4ca5a41a1">Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_4dd47b47-e637-416b-9e41-fa6767feb699">Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_9557e1c8-721b-4b45-ba9c-b34abce7c587">Attribute Description</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_2dc2cebc-df70-4c3f-9a5f-4d00e6fb81fb">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_f03e1215-2273-46fe-a9b9-62aa79a4ecf0">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_3b046ed5-83ab-4782-8c75-3aafa546d394">...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_f3474394-d8ac-4a27-ac60-68a5b39bf425">...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_93da3f27-1d16-4265-9fa3-2a426779e5ab">Source Instance Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_e85044ce-b126-44e3-802e-d5000018448a">(0042,0013)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_dc4a1421-97d1-4efc-b602-381b57df4151">1C</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b8b7e187-1982-4ac2-b4d3-f5a599e49923">A sequence that identifies the set of Instances that were used to derive the encapsulated document.</para>
                <para xml:id="para_25d07b4a-4fbb-45ac-9f08-e5708403317d">One or more Items shall be included in this Sequence.</para>
                <para xml:id="para_d4cd0582-e5dc-4e05-ba5f-638c7f3df3df">Required if derived from one or more DICOM Instances. May be present otherwise.</para>
              <note>
                  <para xml:id="para_d1941b71-7041-4f37-8165-6b26ddabfc4f">Unlike other uses of Source Instance Sequence (0042,0013), such as in the General Reference Module, references to images are permitted in this Module<emphasis role="bold"><emphasis role="strikethrough">, which</emphasis><emphasis role="underline">This Module</emphasis></emphasis> does not include the Source Image Sequence (0008,2112)<emphasis role="bold"><emphasis role="strikethrough">, and t</emphasis><emphasis role="underline">T</emphasis></emphasis>he Defined Context Group for Purpose of Reference Code Sequence (0040,A170) includes an appropriate concept.</para>
              </note>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_d16883e2-98db-4ae5-9247-7ac112e1af2a">
                  <emphasis role="italic">&gt;Include Table 10-11 "SOP Instance Reference Macro Attributes"<!--<xref linkend="table_10-11" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b079aa5e-d328-4beb-b814-477b1f575690"/>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_d137ae60-18ef-47bf-bced-e47b04b576db">&gt;Purpose of Reference Code Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_be1643ed-6710-41d7-b5b6-3d046f28dc19">(0040,A170)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_bd91e58e-87b5-41e9-b5fc-7c713f90e3d7">3</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_01ba8455-966d-4d1a-92a9-2164f7713be2">Describes the purpose for which the reference is made, that is what role the source instances played in the derivation of this encapsulated document</para>
                <para xml:id="para_dddd3221-f293-4a64-9309-ec16ab80204e">Only a single Item single Item is permitted in this Sequence.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_b6ba4bf0-5b57-4ecb-b7eb-f686ffa5ee01">
                  <emphasis role="italic">&gt;&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
                  </emphasis>
                </para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_8807e536-df7c-4a31-9d89-31fe84459534">
                  <emphasis role="italic">Defined <xref linkend="sect_CID_7060" xrefstyle="select: labelnumber quotedtitle nopage"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_7060" xrefstyle="select: labelnumber quotedtitle"/>-->.</emphasis>
                </para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_505e9358-5c66-4405-aad6-b17ee10a54f2">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_944f7941-07ec-4adc-ad67-1e52c4daaa4b">...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_6211e57c-9c32-4c9d-966c-162f2f433204">...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_bb44ac3d-29fc-4a5c-8284-cc01a3aca129">...</para>
              </td>
            </tr>
          </tbody>
        </table>
      </section>
      
      
       
        
      
        
        
        
        
      
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">For reference, DICOM PS3.16 as already amended by Sup 205:</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="CID 7013" status="3" xml:id="sect_CID_7013">
            <title>Non-Image Source Instance Purposes of Reference</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5a1f9d02-4114-44a7-b67f-47287c646162">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7013.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7013.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7013.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1134.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e06e804d-71ef-4799-8561-7e3ace9e4b88">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_23982da9-2d8a-41c4-99fa-acd246577fb6">
                            <emphasis role="bold">20170914</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_780fa825-71c8-442b-964e-e6255f98e7a4">
                            <emphasis role="bold">1.2.840.10008.6.1.1134</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7013" rules="all" xml:id="table_CID_7013">
                <caption>Non-Image Source Instance Purposes of Reference</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ef81430-84a1-4677-b1e1-2fef3730b851">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_67751ad6-f854-421c-93a8-b6c8b233d781">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d36b9e39-711e-414a-a58d-9e1ffdae426f">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11de0f1b-6697-4a42-aeab-ef15db1b276f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e5339aaf-34dc-42ba-9a61-21446d95bde5">
                                <link linkend="DCM_128224" xrefstyle="select: nopage">128224</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c1682f30-7221-4453-a225-a39101a51db1">Source measurement</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f26a154-7565-484e-82e7-c4845a8a796f">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99c39afa-0cab-4f13-a376-c5dc4bbf8406">
                                <link linkend="DCM_128225" xrefstyle="select: nopage">128225</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3fadafbd-4be7-4b88-83ef-297060f4a86a">Source report</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b78a35c-533d-4857-85ed-04325013c421">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f73f8a95-0f83-4d30-8967-5fc8a697b507">
                                <link linkend="DCM_128226" xrefstyle="select: nopage">128226</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7c50c2a1-1f62-4d00-8315-efef574a67a8">Source raw data</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_4a56e3f0-f68a-4caa-89e5-6a5daffe3f05">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <note>
                <para xml:id="para_03b2b843-d8ff-40d3-bfa9-0f035dfa9af9">This context group previously contained a code for "source image", which has been removed.</para>
            </note>
        </section>
      
      
        <section label="CID 7019" status="3" xml:id="sect_CID_7019">
            <title>Segmentation Non-Image Source Purposes of Reference</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2f19c293-b5de-4b90-a6d8-730e3405ad05">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7019.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7019.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7019.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1183.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_97d842df-705c-4724-a566-bc3f6bfa7095">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d091c886-ada9-415c-b47d-a490a8f2ed34">
                            <emphasis role="bold">20170914</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5c290cb5-80b3-48eb-a2cb-7a6e3449d500">
                            <emphasis role="bold">1.2.840.10008.6.1.1183</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7019" rules="all" xml:id="table_CID_7019">
                <caption>Segmentation Non-Image Source Purposes of Reference</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d9290e1-d48e-419d-9695-e5c5d23c335c">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_27148331-5e2a-4610-abea-5bc7972d9150">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e23d81a-9038-43f4-949b-05bd25445951">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_018859d0-8ed2-411e-b4ba-66b9288be435">
                                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31e75eca-82f4-4071-a303-6d421827ad1a">
                                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_662c7c7c-966e-4ed1-8474-f224347168b3">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c61085df-b094-41a4-a020-df85e9f1c0ae">
                                <link linkend="DCM_128227" xrefstyle="select: nopage">128227</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1beffa8a-3aea-448f-b02c-eb51c27a8a45">Source real world value map</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e91ebd71-b5a6-446e-bee0-18fcbec75083"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d797c6a4-3204-40eb-8fae-f97143cd9c8f"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
      
        <section label="CID 7202" status="3" xml:id="sect_CID_7202">
            <title>Source Image Purposes of Reference</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2ed9bd94-5998-4d63-9274-5f01168f507d">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7202.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7202.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7202.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.509.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7ab3922b-6eba-48d1-8771-d110788a9cfc">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_82bdef1d-a670-44d1-965e-8f99fa098cd2">
                            <emphasis role="bold">20170405</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1628feb9-0a87-418f-9dbd-a31359f1bd13">
                            <emphasis role="bold">1.2.840.10008.6.1.509</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7202" rules="all" xml:id="table_CID_7202">
                <caption>Source Image Purposes of Reference</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3036fb1-70a3-46c5-8a67-6e6434673674">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8cbbb03-85b8-4616-9cd7-d9f85fdd8ebd">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5dfa2dce-2692-43ed-907e-d31b1228e965">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e57a961-868f-4099-8aac-fd91db9e91f2">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_604cea36-9e85-4cb6-b5a1-0cbc02576cba">
                                <link linkend="DCM_121320" xrefstyle="select: nopage">121320</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b3061dc4-d594-43fa-bc60-6a7bfc41b850">Uncompressed predecessor</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bac1824b-f382-4e55-a8b7-67640bdb296c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7107a299-bd6f-4c85-936c-0eb76285f497">
                                <link linkend="DCM_121321" xrefstyle="select: nopage">121321</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e2250a97-707b-4297-bc2d-d1a955886568">Mask image for image processing operation</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6eaeeb64-cec5-4238-995b-ae89ec5298e1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff8954c4-52c5-46f5-81af-3893e045466f">
                                <link linkend="DCM_121322" xrefstyle="select: nopage">121322</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7a7ad646-c576-4be8-8f83-7a800649191b">Source image for image processing operation</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4daeff22-3c89-4a61-8e76-ada800ee0cb7">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0bc3a862-a5eb-4fe5-8b48-5129ed32a91e">
                                <link linkend="DCM_121329" xrefstyle="select: nopage">121329</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_488e2a10-6e20-4d3d-a4b9-94760051e357">Source image for montage</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33df4130-9605-47a1-8548-d5434ba87bb4">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0aa89c2-000a-4430-8061-555ea6b17576">
                                <link linkend="DCM_121330" xrefstyle="select: nopage">121330</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a297ffa2-9284-496c-9dc8-9a53d9ab30e9">Lossy compressed predecessor</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d4e4c0a-e9d9-404f-ae86-9da862a8292c">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5c264f00-61f0-4d12-a3dd-eae2dedd38ea">
                                <link linkend="DCM_121358" xrefstyle="select: nopage">121358</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_36f17b31-02f1-4d0e-b3a7-f97aeba9a42c">For Processing predecessor</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e7172ba-8d45-40c0-a80e-b5f4c745bd98">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64395f86-ba3b-4647-b143-574f22150978">
                                <link linkend="DCM_113130" xrefstyle="select: nopage">113130</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d1f0dd9f-f122-4060-bd5f-56e75dc8cefe">Predecessor containing group of imaging subjects</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_00a4f7bb-59e6-4e42-aab8-e739bbcb90a1">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31ab3dbc-8518-4ed0-b86b-372fe19c5fd0">
                                <link linkend="DCM_128250" xrefstyle="select: nopage">128250</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f3457e42-0494-47c0-b86d-7de7c7fd9e52">Structural image for image processing</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7749cd39-04dc-49a9-bc75-3c2e9f9e0ade">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_706b4882-5798-4dee-af4f-1d897895efec">
                                <link linkend="DCM_128251" xrefstyle="select: nopage">128251</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ed947b04-be99-4302-9292-706d2b5c7cbd">Flow image for image processing</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
      
        <section label="CID 7060" status="3" xml:id="sect_CID_7060">
            <title>Encapsulated Document Source Purposes of Reference</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_be9af2e3-c466-42da-bfdc-821d1ed96da8">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7060.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/CID_7060.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/CID_7060.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.494.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_b5026fc0-9f83-429a-a89f-4ed0c542ec5e">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_995b3a0b-b173-4838-bb09-539fd78b92f0">
                            <emphasis role="bold">20180403</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_0ff80e46-a8ad-4bed-ab74-eff11c7b141b">
                            <emphasis role="bold">1.2.840.10008.6.1.1201</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7060" rules="all" xml:id="table_CID_7060">
                <caption>Encapsulated Document Source Purposes of Reference</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc6159d5-1222-4ebd-b157-7c44af4ef32e">
                                <emphasis role="bold">Coding Scheme Designator</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f658941b-a123-47de-8e3d-fd972950470b">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fae2f40-3136-449e-893e-1872cfff8cae">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ecdc6859-91a9-4ea8-bbe6-21e7ff3b8a65">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84bdbe1c-af04-416d-9ba6-1c227017492a">
                                <link linkend="DCM_121324" xrefstyle="select: nopage">121324</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0662b492-b84c-46ef-9d64-55f92bfcbf57">Source image</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_aa51ea7b-df2a-49c4-ac80-6db4c9161cb8">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7013" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
    </chapter>
</book>