<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1744</title>
    <subtitle>Make anatomical information encoding in general and visible light images consistent</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2018/03/27</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para>
                    <para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/09/13</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1744</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Make anatomical information encoding in general and visible light images consistent</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3 2018a</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Rationale for Correction:</para>
                    <para>Older IODs lack a standard mechanism for including anatomic region codes equivalent to the string Body Part Examined, while more recent IODs consistently use Anatomic Region Sequence and Image Laterality. For enterprise imaging it is desirable that these be made consistent.</para>
                    <para>For visible light imaging, such as the VL Photographic IOD, Anatomic Region Sequence is included via the VL Image Module, but Image Laterality is not, which is inconsistent with the pattern established, for example, by Digital X-Ray IODs. The Image Laterality attribute is in widespread use, rather than requiring that it be sent as a modifier of Primary Anatomic Structure Sequence, which is rarely used in practice.</para>
                    <para>Add the necessary attributes as optional in the General Image Module. These are image-level attributes and cannot be added to the General Series Module.</para>
                    <para>The single site optional General Anatomy Macro is added, rather than the multiple site macro, so as not to cause conflict with IODs that include both the General Image Module and more specific Modules that already include Anatomic Region Sequence (e.g., Digital X-Ray).</para>
                    <para>In addition, common anatomy context groups are added for the VL usage, which were not defined at the time of the original VL IOD inclusion. It is expected that additional application-specific context groups will be added in future (e.g., see dermatology-related CP 1674).</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="10.5" status="2" xml:id="sect_10.5">
      <title>General Anatomy Macros</title>
      <para xml:id="para_40b3cc0e-083a-4c9e-9336-5794f2968ed7">... describe the attributes for identifying the general region of the patient anatomy examined using coded terminology, as well as the principal structure(s) within that region that is the target of the current SOP Instance. The only differences between the macros are the Type and Number of Items of the Anatomic Region Sequence (0008,2218) attribute. <xref linkend="table_10-8" xrefstyle="select: label"/> describe the attributes for the coding of the principal structure only.</para>
      <para xml:id="para_2252f1dd-c68c-4851-8841-3c899e1937af">The invocation of these macros may specify Baseline or Defined CIDs for the Anatomic Region Sequence (0008,2218), the Anatomic Region Modifier Sequence (0008,2220), and/or the Primary Anatomic Structure Sequence (0008,2228).</para>
      <para xml:id="para_5de6e6eb-3521-4d3b-901f-965a5ea5c4fd">The general region of the body (e.g., the anatomic region, organ, or body cavity being examined) is identified by the Anatomic Region Sequence (0008,2218). Characteristics of the anatomic region being examined, such as sub-region (e.g., medial, lateral, superior, inferior, lobe, quadrant) and laterality (e.g., right, left, both), may be refined by the Anatomic Region Modifier Sequence (0008,2220).</para>
      <note>
        <para xml:id="para_d18cdcc8-12e6-4998-88d3-9f85f1a2f8f7">These Attributes allow the specification of the information encoded by the Body Part Examined (0018,0015) in the General Series Module<!--<xref linkend="sect_C.7.3.1" xrefstyle="select: title"/>--> in a more robust, consistent way.</para>
      </note>
      <para xml:id="para_5a6e4711-9dc4-4db4-a1f3-b54bc673f249">The specific anatomic structures of interest within the image (e.g., a particular artery within the anatomic region) is identified by the Primary Anatomic Structure Sequence (0008,2228). Characteristics of the anatomic structure, such as its location (e.g., subcapsular, peripheral, central), configuration (e.g., distended, contracted), and laterality (e.g., right, left, both), and so on, may be refined by the Primary Anatomic Structure Modifier Sequence (0008,2230).</para>
            <note>
                <orderedlist>
                    <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">Laterality is often encoded in a separate Attribute, Image Laterality (0020,0062) or Frame Laterality (0020,9072), rather than in Anatomic Region Modifier Sequence (0008,2220) or Primary Anatomic Structure Modifier Sequence (0008,2230). The correspondence between the values is as follows:</emphasis></emphasis></para>
                        <informaltable frame="box" rules="all">
                            <thead>
                                <tr valign="top">
                                    <th align="center" colspan="1" rowspan="1">
                                        <para>Image Laterality (0020,0062) or Frame Laterality (0020,9072)</para>
                                    </th>
                                    <th align="center" colspan="1" rowspan="1">
                                        <para>Coded Modifier</para>
                                    </th>
                                </tr>
                            </thead>
                            <tbody>
                                <tr valign="top">
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">L</emphasis></emphasis></para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">(G-A101, SRT, "Left")</emphasis></emphasis></para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">R</emphasis></emphasis></para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">(G-A100, SRT, "Right")</emphasis></emphasis></para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">(G-A103, SRT, "Unilateral")</emphasis></emphasis></para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">B</emphasis></emphasis></para>
                                    </td>
                                    <td align="center" colspan="1" rowspan="1">
                                        <para><emphasis role="bold"><emphasis role="underline">(G-A102, SRT, "Right and left")</emphasis></emphasis></para>
                                    </td>
                                </tr>
                            </tbody>
                        </informaltable>
                        <para><emphasis role="bold"><emphasis role="underline">The codes illustrated are from CID 244 "Laterality"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_244" xrefstyle="select: labelnumber quotedtitle"/>-->.</emphasis></emphasis></para>
                    </listitem>
                    <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">Whether or not various anatomical structures may be paired or unpaired (have laterality) is illustrated in Table L-5 in PS3.17<!--<olink targetdoc="PS3.17" targetptr="table_L-5" xrefstyle="template:Table %n “%t” in PS3.17"/>-->.</emphasis></emphasis></para>
                    </listitem>
                </orderedlist>
            </note>
            <para>...</para>
      <table frame="box" label="10-7" rules="all" xml:id="table_10-7">
        <caption>General Anatomy Optional Macro Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_6193ccef-2e89-45ce-ab8f-76b31dcd7002">Attribute Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_c7a9e509-99f1-4558-b1d0-4f9a4e242f67">Tag</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_282b2777-0033-4af3-be31-8ae9c579cc34">Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_66cdf02f-68e6-45df-8786-662e68dcdefc">Attribute Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_bcacde1c-235c-45e9-8dc8-ef2e24efd493">Anatomic Region Sequence</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_40df9dab-8bc8-42a9-8353-9650d740ed92">(0008,2218)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_1acd0337-be6a-4853-b136-db305df14a85">3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_47377de6-60aa-42b9-8694-5c94bc39a671">Sequence that identifies the anatomic region of interest in this Instance (i.e., external anatomy, surface anatomy, or general region of the body).</para>
              <para xml:id="para_28d437ed-a1e3-456d-9c54-65fd06202952">Only a single Item is permitted in this Sequence.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_e309f960-ebcf-406d-ad60-1df7e21370b3">
                <emphasis role="italic">&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5c333e8b-bd61-47f8-b9ee-3f7e9033fad4">Context ID may be defined in the macro invocation.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b4761952-636e-4653-8f10-aadbb9624568">&gt;Anatomic Region Modifier Sequence</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_ff080979-52a3-48a0-8e0c-bfde404aabc5">(0008,2220)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_47ff12bc-f016-42c0-a78a-cd084a7e94b5">3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_29ee33e9-1d79-467f-8418-5e3ba1903d41">Sequence of Items that modifies the anatomic region of interest of this Instance</para>
              <para xml:id="para_fc9dbdd5-5a60-48fc-ae5a-f4a55882ba6c">One or more Items are permitted in this Sequence.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_d5ed1915-e8da-438f-ad70-0d0c45ef8d36">
                <emphasis role="italic">&gt;&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b07cffaf-f43d-4829-ad3a-0855545e8d23">Defined CID 2 "Anatomic Modifier"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_2" xrefstyle="select: labelnumber quotedtitle"/>-->, unless otherwise defined in the macro invocation.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_381f8374-2a87-4f87-a326-9c7c3a207f9e">
                <emphasis role="italic">Include <xref linkend="table_10-8" xrefstyle="select: label quotedtitle"/>
</emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_21452d3c-3844-4521-bc0e-687c945ed648">Context ID may be defined in the macro invocation.</para>
            </td>
          </tr>
        </tbody>
      </table>
      <para>...</para>
      <table frame="box" label="10-8" rules="all" xml:id="table_10-8">
        <caption>Primary Anatomic Structure Macro Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_188962e4-09ab-416c-ad41-bd4b926a1808">Attribute Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_01d3aeb1-2aba-40e4-94bf-3abbf6374d3b">Tag</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_5350aa94-ac62-4152-9d3c-d55b95265b75">Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_725e3311-fdda-4ae6-b401-cfabdccb1726">Attribute Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_e32ffbcf-5658-45e5-b1e1-4ad2a782695c">Primary Anatomic Structure Sequence</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_6a6be467-e6f0-483e-a236-5f98375fe3e5">(0008,2228)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_80b4886c-aee3-4452-84e0-4f4eb8d59a86">3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_fc7003cc-8039-4fde-b4bd-3c3d4ed02f9c">Sequence of Items that identifies the primary anatomic structure(s) of interest in this Instance.</para>
              <para xml:id="para_9e678547-6183-4a79-a3d5-5c9566e34e95">One or more Items are permitted in this Sequence.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_76726d45-5476-4add-8558-9b2e9fd7d512">
                <emphasis role="italic">&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cdb338bd-9a36-45c6-a1fb-e246b321b08d">Context ID may be defined in the macro invocation.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5d9289b5-91cd-4892-92c6-889a9792caba">&gt;Primary Anatomic Structure Modifier Sequence</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_740ceb97-e57f-466c-bccb-76dfd8bbe4e5">(0008,2230)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_c6da1105-4259-4bed-afc5-38612dbf241c">3</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_29da9abf-f3de-4030-8fb2-ec3b93c4c67c">Sequence of Items that modifies the primary anatomic structure of interest in this Instance.</para>
              <para xml:id="para_9713a8de-250f-4496-83ba-eff55bce7ca7">One or more Items are permitted in this Sequence.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_50e6ad5e-e8bd-4abe-bd29-eb0ae8abde61">
                <emphasis role="italic">&gt;&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a5541adf-4ae2-4f05-9c98-e583627e3deb">
                  <emphasis role="italic">Defined Defined CID 2 "Anatomic Modifier"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_2" xrefstyle="select: labelnumber quotedtitle"/>-->.</emphasis>
              </para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
        
        
        <section label="C.7.3.1" status="4" xml:id="sect_C.7.3.1">
          <title>General Series Module</title>
          <table frame="box" label="C.7-5a" rules="all" xml:id="table_C.7-5a">
            <caption>General Series Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_04100f31-5424-4105-b397-e81ea26cab1a">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9f6ee2bc-0c72-4acc-bd8a-3b63e075406c">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7be1655a-1548-4c66-a4a3-2f62a8898dc2">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_28b73666-093e-4904-b24e-ab760754d7a0">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cdb6f0e9-188b-4fda-bc33-00244b78db42">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_573048aa-6706-44a7-b7a9-56c1d9580215">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_d64d0571-7bc4-4d9d-b327-23b378fde0d4">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_181afb38-9c62-4435-a027-a593e36049d8">...</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2a731560-4ba7-4a59-b3dc-45acdf3a9766">Laterality</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_56fe38ec-b90a-414b-a876-14be09a57ae2">(0020,0060)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9e0285d1-e4f4-49f6-879f-da838f83f133">2C</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_306706fe-7bb9-4a66-b49c-7cfe7a3cdb1b">Laterality of (paired) body part examined. Required if the body part examined is a paired structure and Image Laterality (0020,0062) or Frame Laterality (0020,9072) or Measurement Laterality (0024,0113) are not present.</para>
                  <variablelist spacing="compact">
                    <title>Enumerated Values:</title>
                    <varlistentry>
                      <term>R</term>
                      <listitem>
                        <para xml:id="para_accaa589-433e-4de4-a2f7-cf283b8a0c36">right</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>L</term>
                      <listitem>
                        <para xml:id="para_79d869ff-3e78-4f82-9ca8-cb93814b5bf1">left</para>
                      </listitem>
                    </varlistentry>
                  </variablelist>
                  <note>
                    <orderedlist>
                      <listitem>
                        <para xml:id="para_46e9d782-b47b-4339-b6ff-a11691e830db">Some IODs support Image Laterality (0020,0062) at the Image level or Frame Laterality (0020,9072) at the Frame level in the Frame Anatomy functional group macro or Measurement Laterality (0024,0113) at the Measurement level, which can provide a more comprehensive mechanism for specifying the laterality of the body part(s) being examined.</para>
                      </listitem>
                      <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">There is no value for both left and right, for which Image Laterality (0020,0062) at the Image level or Frame Laterality (0020,9072) may be used instead.</emphasis></emphasis></para>
                      </listitem>
                    </orderedlist>
                  </note>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8f5b6232-1f6b-44ac-9c12-72b2c8cd7c1b">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7be95d2f-c767-4b94-ad50-67e08573df81">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5cfd6f14-70e8-47db-aa04-38b7079e2bad">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_2dba68c6-c0b1-401b-a411-d2b91b8ad50e">...</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_fe5a37ab-4874-45d7-b948-3298d29da4ef">Body Part Examined</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a03bcf96-ec79-4867-953d-319dde596002">(0018,0015)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_69a304a2-5bb0-4084-af5a-7d67d158fb7c">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8a7abed0-49f7-4ab2-827c-bd95feaa58de">Text description of the part of the body examined. See PS3.16 Annex L "Correspondence of Anatomic Region Codes and Body Part Examined Defined Terms”<!--<olink targetdoc="PS3.16" targetptr="chapter_L" xrefstyle="template:Annex %n “%t” in PS3.16"/>--> for Defined Terms</para>
                  <note>
                    <para xml:id="para_c8ff54a1-69e9-4623-abb8-672af78baddf">Some IODs support the Anatomic Region Sequence (0008,2218), which can provide a more comprehensive mechanism for specifying the body part being examined.</para>
                  </note>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
                <section label="C.7.6.1" status="4" xml:id="sect_C.7.6.1">
          <title>General Image Module</title>
          <para xml:id="para_9244cf78-0bc0-4b3d-8bca-7c65053edad8">
<xref linkend="table_C.7-9" xrefstyle="select: label"/> specifies the Attributes that identify and describe an image within a particular series.</para>
          <table frame="box" label="C.7-9" rules="all" xml:id="table_C.7-9">
            <caption>General Image Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8401777e-d9c1-4d22-8011-9a1bf0fbcea4">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_afde5dfc-2829-42bf-8491-b3bd6c747d8e">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6cd2c26f-14d7-4ff6-9db5-9a9f34361a8a">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_452e431a-5c40-49fc-be7c-dfb46dcd6833">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0e9c35d5-34f9-42ab-8812-46d1e9959ed7">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a37c85dc-6fb9-4c16-85be-260eae301ed3">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e66e3e7a-ac0e-4189-a83c-8e2d09c7725d">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_74eb8d2e-2502-4f2b-b666-dd99e518a978">...</para>
                </td>
              </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Image Laterality</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">(0020,0062)</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">Laterality of (possibly paired) body part (as described in Anatomic Region Sequence (0008,2218)) examined.</emphasis></emphasis></para><variablelist spacing="compact">
                                <title><emphasis role="bold"><emphasis role="underline">Enumerated Values:</emphasis></emphasis></title>
                                <varlistentry>
                                    <term>R</term>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">right</emphasis></emphasis></para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>L</term>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">left</emphasis></emphasis></para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>U</term>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">unpaired</emphasis></emphasis></para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>B</term>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">both left and right</emphasis></emphasis></para>
                                    </listitem>
                                </varlistentry>
                            </variablelist>
                        <para><emphasis role="bold"><emphasis role="underline">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230) and/or Laterality (0020,0060), if present.</emphasis></emphasis></para>
                      <note>
                        <para><emphasis role="bold"><emphasis role="underline">Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series, hence it must be absent if Image Laterality (0020,0062) has different values for Images in the same Series</emphasis></emphasis>.</para>
                      </note>
                                </td>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="3" rowspan="1">
                        <para>
                            <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">Include <xref linkend="table_10-7" xrefstyle="select: label quotedtitle"/>
                            </emphasis></emphasis></emphasis>
                        </para>
                    </td>
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Baseline CID for the Anatomic Region Sequence is CID 4031 "Common Anatomic Regions"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_4031" xrefstyle="select: labelnumber quotedtitle"/>--> for humans and CID 7483 "Common Anatomic Regions for Animals"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_7483" xrefstyle="select: labelnumber quotedtitle"/>--> for animals.</emphasis></emphasis></para>
                    </td>
                </tr>
            </tbody>
          </table>
        </section>
      
      <section label="C.7.6.16.2.8" status="6" xml:id="sect_C.7.6.16.2.8">
        <title>Frame Anatomy Macro</title>
        <table frame="box" label="C.7.6.16-9" rules="all" xml:id="table_C.7.6.16-9">
          <caption>Frame Anatomy Macro Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_709f1142-e305-4e66-b2a9-cff3b48978b7">Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_ee4e4a4f-4aa8-49b4-9314-3377fba1f418">Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_8ea588ce-0f1d-4b40-84d7-db505b52edef">Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_af189e79-fdb2-418d-85a0-89d654b7770b">Attribute Description</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c5755a66-c17c-4f96-be29-2e8f4c4e4c86">Frame Anatomy Sequence</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_f6e3b395-1bc8-480f-9644-2e99b2b2ec58">(0020,9071)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_e06e995f-5c94-4e40-a685-f1bc5fabcee0">1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_2dca8ab2-814e-4d3b-a789-4ae4854b72cb">Identifies anatomic characteristics of this frame.</para>
                <para xml:id="para_f96a515e-5030-4131-b855-457de2391d82">Only a single Item shall be included in this Sequence.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_184068b3-615c-4e68-862e-33aa1c1d3ed1">&gt;Frame Laterality</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_9bf2787c-581a-409f-a0d4-e9e624784ad0">(0020,9072)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_6dcd21a7-9414-4fce-b544-b3986ccacc1c">1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_aa4626e7-f213-427b-85c8-feb68f013cd2">Laterality of (possibly paired) body parts (as described in Anatomic Region Sequence (0008,2218)) examined.</para>
                <variablelist spacing="compact">
                  <title>Enumerated Values:</title>
                  <varlistentry>
                    <term>R</term>
                    <listitem>
                      <para xml:id="para_a4fd24a9-db95-41d8-9acb-2b9ce9a95f1c">right</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>L</term>
                    <listitem>
                      <para xml:id="para_84de153c-0d34-40e3-a9a8-409f8061646d">left</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>U</term>
                    <listitem>
                      <para xml:id="para_0ffef469-2f03-445f-8749-3511bb3fa15e">unpaired</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>B</term>
                    <listitem>
                      <para xml:id="para_edd5449b-a60f-49ab-9ef9-6b27a9ee5a9e">both left and right</para>
                    </listitem>
                  </varlistentry>
                </variablelist>
                <note>
                  <para xml:id="para_108e5f4e-0a18-4e4f-9779-b3c419e18be0">This Attribute is mandatory, in order to ensure that frames maybe positioned correctly relative to one another for display.</para>
                </note>
                <para xml:id="para_5cdc1960-e915-4ea0-8785-61b7654258dc">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230), if present.</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="3" rowspan="1">
                <para xml:id="para_a1679cf8-1537-47d2-9416-a7caf8412ce3">...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_8e3e9168-b4c8-413b-a374-7da5b67747a3">...</para>
              </td>
            </tr>
          </tbody>
        </table>
      </section>

        
        <section label="C.8.11.2" status="4" xml:id="sect_C.8.11.2">
            <title>DX Anatomy Imaged Module</title>
            <para xml:id="para_8a481f97-5448-4851-9e95-517d6c50ebff">
                <xref linkend="table_C.8-69" xrefstyle="select: label"/> contains IOD Attributes that describe the anatomy contained in a DX IOD.</para>
            <table frame="box" label="C.8-69" rules="all" xml:id="table_C.8-69">
                <caption>DX Anatomy Imaged Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d0518db-109b-42a5-b0e0-e9f80ef14160">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_897a745c-8d9b-4add-8ed6-be9276503b9e">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fa0134c-c789-49aa-99a9-0e15e1b617c8">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb4882bc-0981-4543-b5b3-fd14371c263c">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_47cce44a-0dc2-4c08-8cb9-0005f817dcc0">Image Laterality</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b017f86-5409-4efb-aec0-e87e912beddb">(0020,0062)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2606bf56-fa16-4f6a-b63c-678bc6b6a99d">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7f270713-6f48-47e8-a870-bf8fb1d724de">Laterality of (possibly paired) body part (as described in Anatomic Region Sequence (0008,2218)) examined.</para>
                            <variablelist spacing="compact">
                                <title>Enumerated Values:</title>
                                <varlistentry>
                                    <term>R</term>
                                    <listitem>
                                        <para xml:id="para_c26b7ef3-aeb1-402e-b718-8a24b8119248">right</para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>L</term>
                                    <listitem>
                                        <para xml:id="para_04c80a7a-6be4-45e3-9f6e-49231620865a">left</para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>U</term>
                                    <listitem>
                                        <para xml:id="para_4e079060-2ff4-4222-a11c-3af70f1c960f">unpaired</para>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>B</term>
                                    <listitem>
                                        <para xml:id="para_b16e04e1-7bc7-4db5-abb8-214182dd5057">both left and right</para>
                                    </listitem>
                                </varlistentry>
                            </variablelist>
                            <note>
                                <para xml:id="para_776d2cd5-6b5b-43c6-9fb6-2e81e1975c4b">This Attribute is mandatory, in order to ensure that images may be positioned correctly relative to one another for display.</para>
                            </note>
                            <para xml:id="para_9bc1d224-d42d-42eb-b55d-e1d71cb928e2">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230), if present.</para>
                            <note>
                                <para xml:id="para_0b49e79c-de47-4131-8838-d61b70618829">Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series, hence it must be absent<emphasis role="bold"><emphasis role="underline"> if Image Laterality (0020,0062) has different values for Images in the same Series</emphasis></emphasis>.</para>
                            </note>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_256621e0-ae20-4741-bb04-2af5ea7d62e8">
                                <emphasis role="italic">Include Table 10-6 "General Anatomy Required Macro Attributes"<!--<xref linkend="table_10-6" xrefstyle="select: label quotedtitle"/>-->
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_18fa5774-acd2-4586-ac90-6fea0729ed15">Defined CID for the Anatomic Region Sequence is CID 4009 ""<!--<olink targetdoc="PS3.16" targetptr="sect_CID_4009" xrefstyle="select: labelnumber quotedtitle"/>--> for humans, and CID 7482 "DX Anatomy Imaged for Animals"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_7482" xrefstyle="select: labelnumber quotedtitle"/>--> for animals. This is the anatomic region that is placed on the table or bucky for examination.</para>
                            <note>
                                <para xml:id="para_890e3b94-c82d-4f5f-bdc4-08d2c2dad2f0">It is strongly recommended that Anatomic Region Sequence (0008,2218) be present with a value, in order to ensure that images may be positioned correctly relative to one another for display.</para>
                            </note>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="C.8.11.2.1" status="5" xml:id="sect_C.8.11.2.1">
                <title>DX Anatomy Imaged Attribute Descriptions</title>
                <para xml:id="para_1e185d66-2278-4025-8799-e620f5870481">The Attributes in this Module extend the function of Body Part Examined (0018,0015) as used in other IODs, and are intended to be used to facilitate the management of images and series in terms of routing, storage and display, as well as to dictate certain Conditions on Attributes and Modules in the DX IOD.</para>
            </section>
        </section>
        
        <section label="C.8.11.7" status="4" xml:id="sect_C.8.11.7">
          <title>Mammography Image Module</title>
          <table frame="box" label="C.8-74" rules="all" xml:id="table_C.8-74">
            <caption>Mammography Image Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6ffbf382-97d0-4ea9-9f74-97082a3905f2">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6d282b23-e344-47a6-b460-a376cdcfa072">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_cd752113-42c5-4990-b184-d24dc5c9efb9">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_83e883d1-1437-44e4-ae01-dfa98c6f6879">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d8007da2-8e54-4760-98bf-80926bc25c63">Image Laterality</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_91d7a9f4-cce3-4863-8996-7cb4ba6b4091">(0020,0062)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9416a16f-4cfa-4f47-84e4-3bc776b387a0">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_f1391428-0a46-4964-a62f-d6ddb59bd8de">Laterality of the region examined.</para>
                  <variablelist spacing="compact">
                    <title>Enumerated Values:</title>
                    <varlistentry>
                      <term>R</term>
                      <listitem>
                        <para xml:id="para_7fc1397d-0c45-4e2f-afda-2a8c4f6b3c45">right</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>L</term>
                      <listitem>
                        <para xml:id="para_c26d3a61-9e16-49ca-83b1-73662d81ba74">left</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>B</term>
                      <listitem>
                        <para xml:id="para_445f46d7-e152-40bc-a796-94b9c7394d47">both (e.g., cleavage)</para>
                      </listitem>
                    </varlistentry>
                  </variablelist>
                  <para><emphasis role="bold"><emphasis role="underline">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230) and/or Laterality (0020,0060), if present.</emphasis></emphasis></para>
                  <note>
                    <para><emphasis role="bold"><emphasis role="underline">Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series, hence it must be absent if Image Laterality (0020,0062) has different values for Images in the same Series</emphasis></emphasis>.</para>
                  </note>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
      
      <section label="C.8.11.9" status="4" xml:id="sect_C.8.11.9">
        <title>Intra-Oral Image Module</title>
        <table frame="box" label="C.8-76" rules="all" xml:id="table_C.8-76">
          <caption>Intra-Oral Image Module Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_6d1d3e6f-ae62-477c-905c-c9f437c2a72f">Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_11909b20-a94c-4883-a197-a313ebea60f7">Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_d93de723-d138-4451-80a6-5f3f9a095a9d">Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_b5069eb8-fae5-4ece-8249-b892f534c430">Attribute Description</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b87f801c-159a-434c-91bc-5bfd6b47da7a">Image Laterality</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_03060dbb-5679-4ad1-8ca7-704c00d5f0fb">(0020,0062)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_7218c21d-1690-422b-8f7e-802fec76751e">1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_1b4fbc11-46cd-4f33-8aba-cce0bc2519ee">Laterality of the region examined.</para>
                <variablelist spacing="compact">
                  <title>Enumerated Values:</title>
                  <varlistentry>
                    <term>R</term>
                    <listitem>
                      <para xml:id="para_e228bd29-8159-4e3a-bc46-465e00b4f51c">right</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>L</term>
                    <listitem>
                      <para xml:id="para_c0213ab0-23d4-467c-943e-236305ffea06">left</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>B</term>
                    <listitem>
                      <para xml:id="para_3680eeee-8376-4d6c-ae8e-a40fae1faa37">both (i.e., midline)</para>
                    </listitem>
                  </varlistentry>
                </variablelist>
                <para><emphasis role="bold"><emphasis role="underline">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230) and/or Laterality (0020,0060), if present.</emphasis></emphasis></para>
                <note>
                  <para><emphasis role="bold"><emphasis role="underline">Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series, hence it must be absent if Image Laterality (0020,0062) has different values for Images in the same Series</emphasis></emphasis>.</para>
                </note>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
          </tbody>
        </table>
      </section>
      
        <section label="C.8.12.1" status="4" xml:id="sect_C.8.12.1">
          <title>VL Image Module</title>
          <para xml:id="para_c41fccb9-e99b-4503-a7c2-609d65e5d3c7">
<xref linkend="table_C.8-77" xrefstyle="select: label"/> specifies the Attributes that describe a VL Image produced by Endoscopy (ES), General Microscopy (GM), Automated-Stage Microscopy (SM), External-camera Photography (XC), or other VL imaging Modalities.</para>
          <table frame="box" label="C.8-77" rules="all" xml:id="table_C.8-77">
            <caption>VL Image Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_dec2f23f-1fde-4683-a558-cfb56cd497a8">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_1dacf9cc-f3a1-4997-a1ad-0d0784b32b2d">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8c38b926-1485-4b1b-bc04-c3040119f4ca">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6bd5f013-7752-4bc1-a387-31db253a8168">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_71135779-03fd-48a4-8507-a4dca86b7c53">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ec148011-0b3a-4b3c-9aa5-1065c2c21550">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3602f94b-e7e1-4b0a-8eef-e3461c789116">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_822dab06-44fd-45a4-a960-a7d14f24529a">...</para>
                </td>
              </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Image Laterality</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">(0020,0062)</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                    </td>
                    <td align="left" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">Laterality of (possibly paired) body part (as described in Anatomic Region Sequence (0008,2218)) examined.</emphasis></emphasis></para>
                      <variablelist spacing="compact">
                        <title><emphasis role="bold"><emphasis role="underline">Enumerated Values:</emphasis></emphasis></title>
                        <varlistentry>
                            <term>R</term>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">right</emphasis></emphasis></para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>L</term>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">left</emphasis></emphasis></para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>U</term>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">unpaired</emphasis></emphasis></para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>B</term>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">both left and right</emphasis></emphasis></para>
                            </listitem>
                        </varlistentry>
                    </variablelist>
                        <para><emphasis role="bold"><emphasis role="underline">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230) and/or Laterality (0020,0060), if present.</emphasis></emphasis></para>
                      <note>
                        <para><emphasis role="bold"><emphasis role="underline">Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series, hence it must be absent if Image Laterality (0020,0062) has different values for Images in the same Series</emphasis></emphasis>.</para>
                      </note>
                    </td>
                </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ae6134bd-6798-4be7-a7a6-637cfeb1619c">Anatomic Region Sequence</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_3266e6c7-2f1e-4d5d-ad5b-1c1dfbfbed27">(0008,2218)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_778e1ca2-2117-4f2f-8e06-266b008146e5">1C</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_82a5786c-cf3f-4c37-80b5-7408247ef22c">Sequence that identifies the anatomic region of interest in this image (i.e., external anatomy, surface anatomy, or general region of the body).</para>
                  <para xml:id="para_d89278ed-1ad2-428a-8e1d-acc63e6c0691">Only a single Item shall be included in this Sequence.</para>
                  <para xml:id="para_0e8bef10-fc71-4503-903b-794ae7ce2459">Required if Number of Frames (0028,0008) is present and Specimen Description Sequence (0040,0560) is absent. May be present otherwise.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="3" rowspan="1">
                  <para xml:id="para_95df2d93-c33d-4dc7-899d-59b3527d2bfb">
                    <emphasis role="italic">&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
                  </para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                    <para xml:id="para_4a64887d-cd99-4c9c-9eea-f4f93834ff18">Defined CID 4040 "Endoscopy Anatomic Regions"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_4040" xrefstyle="select: labelnumber quotedtitle"/>--> is defined for the Video Endoscopic IOD.</para>
                  <para xml:id="para_1c2be47a-75c3-4f7f-8a14-f872efc31eb7"><emphasis role="bold"><emphasis role="strikethrough">For other IODs, no Context ID is defined.</emphasis></emphasis></para>
                  <para><emphasis role="bold"><emphasis role="underline">Baseline CID for the Anatomic Region Sequence is CID 4031 "Common Anatomic Regions"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_4031" xrefstyle="select: labelnumber quotedtitle"/>--> for humans and CID 7483 "Common Anatomic Regions for Animals"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_7483" xrefstyle="select: labelnumber quotedtitle"/>--> for animals.</emphasis></emphasis></para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_bb52ef22-cb45-4c61-be0c-7b35aa749d68">&gt;Anatomic Region Modifier Sequence</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a4d3f001-43fa-4497-b01a-dedf01af926b">(0008,2220)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_bf88aef7-b8c7-4002-b3e6-2144c9cd253b">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_04fd8de0-a03e-45e7-8c5a-13549e67ca31">Sequence of Items that modifies the anatomic region of interest of this image</para>
                  <para xml:id="para_995d151c-80b4-4bb3-bac2-55dc6bc33c93">One or more Items are permitted in this Sequence.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="3" rowspan="1">
                  <para xml:id="para_af16ff11-57d4-4943-809c-f1cf67b990c2">
                    <emphasis role="italic">&gt;&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
</emphasis>
                  </para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0ce44d8f-16c5-4ec8-96a1-197d23b0a228">
                      <emphasis role="italic">Baseline CID 2 "Anatomic Modifier"<!--<olink targetdoc="PS3.16" targetptr="sect_CID_2" xrefstyle="select: labelnumber quotedtitle"/>-->.</emphasis>
                  </para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="3" rowspan="1">
                  <para xml:id="para_95f34a1a-c6b1-4e12-85f8-e6c5f70ada07">
                    <emphasis role="italic">Include <xref linkend="table_10-8" xrefstyle="select: label quotedtitle"/>
</emphasis>
                  </para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_af5cd744-6591-4928-b2b6-ee1f2774aa0d">No Context ID is defined. These Type 3 Attributes are not appropriate when Specimen Description Sequence (0040,0560) is present, as it includes the Primary Anatomic Structure Macro for each specimen in the image.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_cd2a4235-dc44-48a6-9d85-b4598bedebb4">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_b069233b-887c-44b5-83ca-185694e03f26">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ac832e5c-87fe-4fce-870d-859afac94125">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_ad8a7355-304c-427c-8631-4e48ed04c865">...</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>
        
      <section label="C.8.17.5" status="4" xml:id="sect_C.8.17.5">
        <title>Ocular Region Imaged Module</title>
        
        <table frame="box" label="C.8.17.5-1" rules="all" xml:id="table_C.8.17.5-1">
          <caption>Ocular Region Imaged Module Attributes</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_af55b37e-a1bf-45db-a3dd-322c25d93d95">Attribute Name</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_7a00a15d-7198-478b-9326-183ca4fd2e60">Tag</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_0d6e9821-5dbf-4332-bbce-b15b16d43b1c">Type</para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_ff39458d-ad27-4411-b3fc-0c8e10e8bc92">Attribute Description</para>
              </th>
            </tr>
          </thead>
          <tbody>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_76e45c24-1332-426c-a59a-76115e579019">Image Laterality</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_5f5ca1fc-e87f-4d4b-95a0-c05eaa4f1c86">(0020,0062)</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para xml:id="para_e8912b11-da5e-423f-bf00-5e37b379db32">1</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_67c629f9-dc10-437b-8d88-e300a9ac4e09">Laterality of object imaged (as described in Anatomic Region Sequence (0008,2218)) examined.</para>
                <variablelist spacing="compact">
                  <title>Enumerated Values:</title>
                  <varlistentry>
                    <term>R</term>
                    <listitem>
                      <para xml:id="para_83c63b9f-09d4-4af7-a1ba-9b251e3f4c04">right eye</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>L</term>
                    <listitem>
                      <para xml:id="para_bc73c725-5c04-479c-8c1e-13af0a8bedb7">left eye</para>
                    </listitem>
                  </varlistentry>
                  <varlistentry>
                    <term>B</term>
                    <listitem>
                      <para xml:id="para_d9797457-0517-4753-a770-5ee8bc090f14">both left and right eye</para>
                    </listitem>
                  </varlistentry>
                </variablelist>
                <para xml:id="para_07adb870-242c-414d-8a97-5f8f052171fa">Shall be consistent with any laterality information contained in Primary Anatomic Structure Modifier Sequence (0008,2230), if present.</para>
                <note>
                  <para xml:id="para_837225a0-5580-420e-8930-120a51d8485c">Laterality (0020,0060) is a Series level Attribute and must be the same for all Images in the Series<emphasis role="bold"><emphasis role="underline">, hence it must be absent if Image Laterality (0020,0062) has different values for Images in the same Series</emphasis></emphasis>. Since most Ophthalmic Photographic Image <emphasis role="bold"><emphasis role="strikethrough">Studies</emphasis><emphasis role="underline">Series</emphasis></emphasis> contain images of both eyes, the Series level Attribute will rarely be present.</para>
                </note>
              </td>
            </tr>
            <tr valign="top">
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="center" colspan="1" rowspan="1">
                <para>...</para>
              </td>
              <td align="left" colspan="1" rowspan="1">
                <para>...</para>
              </td>
            </tr>
          </tbody>
        </table>
        
      </section>
    </chapter>
</book>