<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-1682</title>
  <subtitle>Defined PET Units Defined terms by reference to UCUM used in Context Group</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/09/14</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>QIICR</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
              <td rowspan="1" colspan="1" valign="top"><para>2017/01/19</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1682</para></td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Defined PET Units Defined terms by reference to UCUM used in Context Group</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.16 2017c</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                  <para>A context group equivalent to the PET Units (0054,1001) Defined Terms was added in the past, but the two were not specifically mapped.</para>
          <para>Not all of the Units defined terms are included in CID 84. Those that are intended for SUV have more specific meanings with the SUV type pre-coordinated in CID 85. Standard deviation is  challenging, because it could be the square root of any quantity.</para>
          <para>An inconsistency was observed between the Defined Terms in Table C.8-60 and Section C.8.9.1.1.3, in that CM2ML was present in the former but not the latter; add it to the latter as well as CID 84.</para>
               </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
  <chapter>
    <title/>

    <informaltable rules="all" frame="box">
      <tr>
        <td>
          <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
        </td>
      </tr>
    </informaltable>
    
    <section label="C.8.9.1" status="4" xml:id="sect_C.8.9.1">
          <title>PET Series Module</title>
          <table frame="box" label="C.8-60" rules="all" xml:id="table_C.8-60">
            <caption>PET Series Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7508cef2-d373-4cb4-ab01-16f5a978f8a5">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7b71e149-2d25-4ca6-a50d-c2ffef1e9704">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e4dcd9fd-3650-45d8-a5cd-3dfca89e99e6">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_8ce02659-d8cf-4c44-9ea0-b121b53d9bc7">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0474fd1e-b1f3-4b6b-95b4-ca32b0a63e82">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_6f095005-7b76-41f8-b194-3f4121107c93">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f209fc29-74c3-4892-b815-9dcd1f31703b">,..</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_1fb17223-c8e0-4f62-83dd-1d91c64d7b21">...</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_8dcbaade-6ec8-46f3-9a05-556c7fbc54ca">Units</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_0632ab82-5878-491d-a35e-d329924848b4">(0054,1001)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_7b6df5ab-c36e-49bd-8aed-af186acfc760">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_b0e2bd66-860d-4fa5-a148-5ad8413618d9">Pixel value units. See <xref linkend="sect_C.8.9.1.1.3" xrefstyle="select: label"/> for <emphasis role="bold"><emphasis role="strikethrough">explanation</emphasis>
                  <emphasis role="underline">Defined Terms</emphasis></emphasis>.</para>
                  <variablelist spacing="compact">
                    <title><emphasis role="bold"><emphasis role="strikethrough">Defined Terms:</emphasis></emphasis></title>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">CNTS</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_bee4d823-1583-4b76-b665-39a7da89907a"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">NONE</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_e2cea53b-efac-4201-9812-b7eb1d459c56"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">CM2</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_0bfdb8cf-eb71-4fbd-8aa4-0842e58683a2"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">CM2ML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_4a86332e-4538-46b1-9898-db05ec2adec2"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">PCNT</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_41d13a31-de50-48b3-83c5-a641a115b5b9"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">CPS</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_3d40558a-f101-4b8e-baf4-b8df6a304c45"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">BQML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_0238f42f-cd52-4c07-b4b4-a1f83628618d"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">MGMINML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_7df882cf-ecba-4415-976c-98cf34828483"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">UMOLMINML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_3aedc1f4-ebc9-48c1-a7fb-f07eb632e5f7"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">MLMING</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_610d3dc1-3399-4c1a-897a-3b0f8c0a9d23"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">MLG</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_51e7636a-9b4b-4fc9-9ce1-b172594aca24"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">1CM</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_63ced855-2584-4369-97f5-d4894030ecc6"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">UMOLML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_3090fb78-1b1f-46cd-b944-d63ee1fa2b3c"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">PROPCNTS</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_c4fb88c6-c4cd-4d8a-adc0-bc064c075f51"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">PROPCPS</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_1ef886b9-ef8b-4b59-a4e5-9357aeb5637c"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">MLMINML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_7148b77a-d8f8-4e6a-b7c8-16922a6320a6"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">MLML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_c4b19d4c-a1ca-4771-86c4-364f8a3b52fb"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">GML</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_8b265e49-5084-444b-832f-fa20517e7fd9"/>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term><emphasis role="bold"><emphasis role="strikethrough">STDDEV</emphasis></emphasis></term>
                      <listitem>
                        <para xml:id="para_bb9588b8-9fa2-4fc4-8e37-82a043bfdf86"/>
                      </listitem>
                    </varlistentry>
                  </variablelist>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_d7e96cbb-906b-4f3c-a711-9b7414f4ba65">SUV Type</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_e96eebfc-a7ea-4c2d-87c7-d5aa08ac6db2">(0054,1006)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_9f173004-d315-4903-8f0e-70adffed0a06">3</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c1d928f9-845e-4c0d-b091-2cee8e17ab56">Type of Standardized Uptake Value (SUV).</para>
                  <variablelist spacing="compact">
                    <title>Enumerated Values:</title>
                    <varlistentry>
                      <term>BSA</term>
                      <listitem>
                        <para xml:id="para_1f09a3e1-fb52-4bb3-8725-22f2fc8a9d2b">body surface area</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>BW</term>
                      <listitem>
                        <para xml:id="para_590e6719-78d0-46fb-8df7-b0470b715f57">body weight</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>LBM</term>
                      <listitem>
                        <para xml:id="para_56343d9d-0b3b-41d7-b5a4-30d9c20ef0b5">lean body mass by James method</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>LBMJAMES128</term>
                      <listitem>
                        <para xml:id="para_2401d9cd-d936-4a40-bf5e-939c41807e4e">lean body mass by James method using a multiplier of 128 for males</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>LBMJANMA</term>
                      <listitem>
                        <para xml:id="para_7155a374-5732-4791-bb24-48e6acff512c">lean body mass by Janmahasatian method</para>
                      </listitem>
                    </varlistentry>
                    <varlistentry>
                      <term>IBW</term>
                      <listitem>
                        <para xml:id="para_97cd396e-2b1c-45c6-8b21-dc75dc7b6c76">ideal body weight</para>
                      </listitem>
                    </varlistentry>
                  </variablelist>
                  <para xml:id="para_c1200938-84b8-4a3a-b0f4-fe43359e9b7e">If absent, and the Units (0054,1001) are GML, then the type of SUV shall be assumed to be BW.</para>
                  <note>
                    <para xml:id="para_522db716-4502-4fd7-875c-607fc7291ca6">The type of SUV cannot reliably be deduced from the units alone, i.e., SUVbw, SUVibw and SUVlbm (James or Janmahasatian) all have units of GML.</para>
                  </note>
                </td>
              </tr>
              
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
              </tr>
            </tbody>
          </table>
      <note>
        <para xml:id="para_6dc98ecd-8792-4a35-91c7-e817b2988a3e">The formulas for the determination of SUVbw, SUVbsa, SUVlbm (James) and SUVibw are defined in Sugawara et al. 
          <emphasis role="italic">Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.</emphasis> Radiology, 1999 at 
          <link xl:href="http://radiology.rsna.org/content/213/2/521"/>.</para>
        <para xml:id="para_803b6876-82e6-4505-8b3c-97094cd79ebe">Unfortunately, Sugawara used a parameter of 120 rather than 128 for males, propagating an error in
          Morgan DJ, Bray KM. Lean Body Mass as a Predictor of Drug Dosage: Implications for Drug Therapy. Clinical Pharmacokinetics. 1994;26(4):292–307,
          which misquoted the original LBM definition that used 128 in
          James WPT, Waterlow JC. Research on Obesity: A Report of the DHSS/MRC Group. London: Her Majesty’s Stationery Office; 1976.
          Implementations differ in whether they have used 120 or 128 when the DICOM Defined Term is LBM.
          See Kelly M. SUV: Advancing Comparability and Accuracy. Siemens; 2009.
          Available from: <link xl:href="http://www.mpcphysics.com/documents/SUV_Whitepaper_Final_11.17.09_59807428_2.pdf"/>.</para>
        <para xml:id="para_b4de5dbc-d639-48c8-bc66-6aca0575f125">The Janmahasatian LBM formula is defined in <emphasis role="italic">Janmahasatian et al. Quantification of Lean Bodyweight. Clin Pharmacokinet. 2005 Oct 1;44(10):1051–65.</emphasis> at <link xl:href="http://dx.doi.org/10.2165/00003088-200544100-00004"/>
          and its role in SUVlbm(Janma) calculation is discussed in <emphasis role="italic">Tahari et al. Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging. Journal of Nuclear Medicine. 2014 Sep 1;55(9):1481–4. </emphasis> at <link xl:href="http://jnm.snmjournals.org/content/55/9/1481"/>.
          See also <xref linkend="sect_CID_85" xrefstyle="select: labelnumber quotedtitle"/><!--<olink targetdoc="PS3.16" targetptr="sect_CID_85" xrefstyle="select: docname labelnumber quotedtitle"/>-->.</para>
      </note>
          <section label="C.8.9.1.1" status="5" xml:id="sect_C.8.9.1.1">
            <title>PET Series Attribute Descriptions</title>
            <section label="C.8.9.1.1.3" status="6" xml:id="sect_C.8.9.1.1.3">
              <title>Units</title>
              <para xml:id="para_8f0a650f-bf44-4793-bffc-af957979ed7d">The units of the pixel values obtained after conversion from the stored pixel values (SV) (Pixel Data (7FE0,0010)) to pixel value units (U), as defined by Rescale Intercept (0028,1052) and Rescale Slope (0028,1053).</para>
              <variablelist spacing="compact">
                <title>Defined Terms:</title>
                <varlistentry>
                  <term>CNTS</term>
                  <listitem>
                    <para xml:id="para_5a670af9-2fda-47bb-9bf7-050ac7f3f448">counts<emphasis role="bold"><emphasis role="underline"> ({counts}, UCUM, "Counts")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>NONE</term>
                  <listitem>
                    <para xml:id="para_42b3cc3b-8967-4b70-93d7-966925cada8c">unitless<emphasis role="bold"><emphasis role="underline"> (1, UCUM, "no units")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>CM2</term>
                  <listitem>
                    <para xml:id="para_2aba16bf-5c81-481e-a035-3509ecfa4e15">centimeter**2<emphasis role="bold"><emphasis role="underline"> (cm2, UCUM, "Centimeter**2")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>CM2ML</term>
                  <listitem>
                    <para><emphasis role="bold"><emphasis role="underline">centimeter**2/milliliter (cm2/ml, UCUM, "Centimeter**2/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>PCNT</term>
                  <listitem>
                    <para xml:id="para_b6016c10-b20b-44c6-aa90-e331760fb616">percent<emphasis role="bold"><emphasis role="underline"> (%, UCUM, "Percent")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>CPS</term>
                  <listitem>
                    <para xml:id="para_759bc7a3-90db-4d3b-b26f-624f22ddc74d">counts/second<emphasis role="bold"><emphasis role="underline"> ({counts}/s, UCUM, "Counts per second")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>BQML</term>
                  <listitem>
                    <para xml:id="para_39cd110c-b1fa-41bc-b28b-6e47a386e653">Becquerels/milliliter<emphasis role="bold"><emphasis role="underline"> (Bq/ml, UCUM, "Becquerels/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>MGMINML</term>
                  <listitem>
                    <para xml:id="para_48ca3b97-5db7-463f-a4b8-e48d222115ea">milligram/minute/milliliter<emphasis role="bold"><emphasis role="underline"> (mg/min/ml, UCUM, "Milligrams/minute/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>UMOLMINML</term>
                  <listitem>
                    <para xml:id="para_b9ee2950-56e4-4d43-a318-3b4b338aaa4b">micromole/minute/milliliter<emphasis role="bold"><emphasis role="underline"> (umol/min/ml, UCUM, "Micromole/minute/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>MLMING</term>
                  <listitem>
                    <para xml:id="para_f90efd8f-67ce-489c-bbbe-d459648ac2d3">milliliter/minute/gram<emphasis role="bold"><emphasis role="underline"> (ml/min/g, UCUM, "Milliliter/minute/gram")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>MLG</term>
                  <listitem>
                    <para xml:id="para_b698b943-7b1f-4b78-968a-3b881ffb7347">milliliter/gram<emphasis role="bold"><emphasis role="underline"> (ml/g, UCUM, "Milliliter/gram")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>1CM</term>
                  <listitem>
                    <para xml:id="para_0e4852cd-4eda-42e5-a3a3-a22fbcf61d1c">1/centimeter<emphasis role="bold"><emphasis role="underline"> (/cm, UCUM, "/Centimeter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>UMOLML</term>
                  <listitem>
                    <para xml:id="para_1a2e2b82-0451-465b-ab38-d727d96d0870">micromole/milliliter<emphasis role="bold"><emphasis role="underline"> (umol/ml, UCUM, "Micromole/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>PROPCNTS</term>
                  <listitem>
                    <para xml:id="para_d08e6b6d-59c4-44e6-8c9c-be4045d15499">proportional to counts<emphasis role="bold"><emphasis role="underline"> ({propcounts}, UCUM, "Proportional to counts")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>PROPCPS</term>
                  <listitem>
                    <para xml:id="para_44e3cd27-0838-4b1c-aeab-346a93eab83d">proportional to counts/sec<emphasis role="bold"><emphasis role="underline"> ({propcounts}/s, UCUM, "Proportional to counts per second")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>MLMINML</term>
                  <listitem>
                    <para xml:id="para_aff20282-3ad4-4957-9dd3-117442de3e4d">milliliter/minute/milliliter<emphasis role="bold"><emphasis role="underline"> (ml/min/ml, UCUM, "Milliliter/minute/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>MLML</term>
                  <listitem>
                    <para xml:id="para_1f8d7ae4-1185-4066-9b50-5e3f9f5e20a7">milliliter/milliliter<emphasis role="bold"><emphasis role="underline"> (ml/ml, UCUM, "Milliliter/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>GML</term>
                  <listitem>
                    <para xml:id="para_6f623976-4cf0-417a-8749-9f100f1034e7">grams/milliliter<emphasis role="bold"><emphasis role="underline"> (g/ml, UCUM, "Gram/milliliter")</emphasis></emphasis></para>
                  </listitem>
                </varlistentry>
                <varlistentry>
                  <term>STDDEV</term>
                  <listitem>
                    <para xml:id="para_e8a2b49c-8855-41d2-94f1-c117c4754229">standard deviations</para>
                  </listitem>
                </varlistentry>
              </variablelist>
            <note>
              <para><emphasis role="bold"><emphasis role="underline">The majority of these defined terms are equivalent to PS3.16 CID 84 PET Units. Those that are used for SUV are not qualified by the type of SUV, which is encoded separately as SUV Type (0054,1006).</emphasis></emphasis></para>
            </note>
            </section>
          </section>
        </section>
    
    
    <informaltable rules="all" frame="box">
      <tr>
        <td>
          <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
        </td>
      </tr>
    </informaltable>
    
    <section label="CID 84" status="3" xml:id="sect_CID_84">
      <title>PET Units</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para xml:id="para_d2513e41-d059-43a3-bf65-46d14ecb6f78">
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para xml:id="para_74089d91-8980-49d8-88c2-7733d3063c89">
              <emphasis role="bold"><emphasis role="strikethrough">20141110</emphasis>20170914</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table frame="box" label="CID 84" rules="all" xml:id="table_CID_84">
        <caption>PET Units</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_97268f5e-8292-4bfb-82d9-a1b1706fbaac">
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_0b987147-1a61-460a-ae8c-8ae6344de823">
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_1657b646-4e16-44bc-a40a-6ba15d283775">
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="3" rowspan="1">
              <para xml:id="para_b22ef7d3-e1f7-454d-ab82-dd08aefb5e7f">
                <emphasis role="italic">Include <xref linkend="sect_CID_85" xrefstyle="select: labelnumber quotedtitle nopage"/>
                </emphasis>
              </para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_0b06214c-36c6-41c1-b11b-4c7ee7de0002">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_217e5d63-53e8-42c4-b275-1a9acac890c5">{counts}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_e9ea1163-5a61-4a93-b36f-9ff78834f652">Counts</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_0be0367a-971b-4818-82d4-a56d4c627cef">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_c99c5a25-ef51-4800-b315-50320672dce2">{counts}/s</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_8c6d0a85-7aef-44e7-8b84-99ab379fa907">Counts per second</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_6643bb83-0b2c-4768-b000-73dffb5aaa9b">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_eebff1cf-81fe-46e1-95a8-b96f21d52cea">{propcounts}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d1105f6d-042a-4315-aa0a-ba0f6d81cce7">Proportional to counts</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_d0256b98-7443-4045-bd71-6efe144a09a1">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_cf3df64f-cbfa-4ce6-b1d3-3043664da53b">{propcounts}/s</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_54a5796d-4691-4f90-9157-ce545f520700">Proportional to counts per second</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_c483c81f-1ddf-44e7-9d43-0a6c5811c2d1">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_8b0b0c61-c6e3-46fa-a89b-86b5dfa62847">cm2</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9ff23dc6-d4b2-4141-8384-ecf95325f486">Centimeter**2</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">UCUM</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">cm2/ml</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Centimeter**2/milliliter</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_a72c4cf4-5be4-469e-bf5f-34ddee025008">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_6cdab932-83ef-4c12-adf7-54a3e117ddcf">%</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3bfe2fdb-c986-4920-85de-3f3bec4da4f4">Percent</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_530a306d-3a9c-461b-99b0-79f988aed2ae">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_583c7120-2619-4b0a-8e52-22c3f2b1a5d0">Bq/ml</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_051a1b6f-2f42-48f5-8227-51f906c7ca48">Becquerels/milliliter</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_93f2a2cf-65c6-465c-9477-453faf6d2488">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_e3687263-62a5-4d33-bbd1-4f8fba052752">mg/min/ml</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_8d576d8e-eddc-40f0-a657-311cd0f757a4">Milligrams/minute/milliliter</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_a439a427-1b64-4ab4-b50a-64a25f9dbfa9">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_9fbc37b1-2079-47be-8596-3cc7d4644a12">umol/min/ml</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3fd5a00e-d606-44cf-9e3f-dca1feb5e714">Micromole/minute/milliliter</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_bf53b92d-b899-4078-a8a4-597b7e8e3113">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_06f51eb4-4880-4e4a-bdeb-c3a6aa20338e">ml/min/g</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cc9aec0e-ab40-4091-bb34-24021a4b177c">Milliliter/minute/gram</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_2e6b5c36-c592-49aa-9da6-a4e91f41d23e">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_b220766b-a09b-4df8-9256-784f13b2c386">ml/g</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_62a29e61-e158-468d-9851-92624c076cea">Milliliter/gram</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_34dd648f-be65-43b5-a50d-94705ad6948c">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_3f91d833-bc38-42d4-9efe-c247ab6c4a49">/cm</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cd83501a-8e91-4bc5-9307-253fed2ed385">/Centimeter</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_c6724ff0-456c-425a-86d1-4cb8cad82a1c">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_0a7167d0-5e5f-42b3-a6b3-ccf15d77e404">umol/ml</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_3705ca3e-fab3-4408-a7c2-402ebacfe269">Micromole/milliliter</para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    
    <section label="CID 85" status="3" xml:id="sect_CID_85">
      <title>SUV Units</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para xml:id="para_1233c115-159e-4923-8177-2fdfb7e5fd11">
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para xml:id="para_798e4c11-1fcc-41c5-8d20-a5ad53ead4d8">
              <emphasis role="bold">20161106</emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table frame="box" label="CID 85" rules="all" xml:id="table_CID_85">
        <caption>SUV Units</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_64d64317-1a6a-41a2-9031-58566be0d9e2">
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_8bc22f66-ffc5-4b2b-a04a-88a43bcd6e00">
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_2d06eea7-6f2e-4033-82d0-190fe081f18e">
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_7461633a-9d61-4a97-9940-69e4b4ead6a3">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_0dfd9e64-7a63-436d-a0a8-66d978db7743">g/ml{SUVbw}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cf9c6c61-7a52-4c20-b7a6-306e42f5a88d">Standardized Uptake Value body weight</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_6d949794-0fb2-4cd3-95e8-0ead381dd70c">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_4742fa17-0d2f-49b1-9a90-59d067bfff04">g/ml{SUVlbm}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_a7fd7d41-fca4-4957-b0c5-0bcfb58cfe86">Standardized Uptake Value lean body mass (James)</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_84ba11c0-4946-4490-829f-1dccb1bb0ff8">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_6d6f4b03-3c05-4a5c-915a-48f57b4d4751">g/ml{SUVlbm(James128)}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c47aaf8d-1990-4893-8398-b3c6d2be08ef">Standardized Uptake Value lean body mass (James 128 multiplier)</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_3c0f0b0e-6ef8-4999-904a-042e7a5a72a8">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_c935b0a8-2e2c-4866-8ebd-9b1b7aca6f92">g/ml{SUVlbm(Janma)}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_9d2ad1fd-28ce-468e-9f38-1f67a7015431">Standardized Uptake Value lean body mass (Janma)</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_c5ae4cd9-1735-42fd-89ef-6256ed332edb">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_59c9cf00-fe3f-4742-b1dc-397a1bc84e6f">cm2/ml{SUVbsa}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_cf2e79f6-1993-44e9-8cd4-f3d3ec5e7cef">Standardized Uptake Value body surface area</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_f15fc726-0de8-430d-bafa-a885ff3a6e84">UCUM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_df84794c-3cba-4529-a64f-30383dea2229">g/ml{SUVibw}</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_056ac97a-80b9-4481-b27c-f1b7ff614161">Standardized Uptake Value ideal body weight</para>
            </td>
          </tr>
        </tbody>
      </table>
      <note>
        <para xml:id="para_100b164d-1936-487d-97a8-c6cb77f8feaa">The formulas for the determination of SUVbw, SUVbsa, SUVlbm (James) and SUVibw are defined in
          Sugawara et al. <emphasis role="italic">Reevaluation of the Standardized Uptake Value for
            FDG: Variations with Body Weight and Methods for Correction.</emphasis>Radiology, 1999
          at <link xl:href="http://radiology.rsna.org/content/213/2/521"/>.</para>
        <para xml:id="para_e4a43e97-ce70-43ff-9ada-70d332af7010">Unfortunately, Sugawara used a parameter of 120 rather than 128 for males, propagating an error in
          Morgan DJ, Bray KM. Lean Body Mass as a Predictor of Drug Dosage: Implications for Drug Therapy. Clinical Pharmacokinetics. 1994;26(4):292–307,
          which misquoted the original LBM definition that used 128 in
          James WPT, Waterlow JC. Research on Obesity: A Report of the DHSS/MRC Group. London: Her Majesty’s Stationery Office; 1976.
          Implementations differ in whether they have used 120 or 128 for ({SUVlbm}g/ml{SUVlbm}, UCUM, "Standardized Uptake Value lean body mass (James)").
          See Kelly M. SUV: Advancing Comparability and Accuracy. Siemens; 2009.
          Available from: <link xl:href="http://www.mpcphysics.com/documents/SUV_Whitepaper_Final_11.17.09_59807428_2.pdf"/>.</para>
        <para xml:id="para_5b0aa249-0258-49f2-a27f-6255009d73b3">The Janmahasatian LBM formula is defined in <emphasis role="italic">Janmahasatian et al. Quantification of Lean Bodyweight. Clin Pharmacokinet. 2005 Oct 1;44(10):1051–65.</emphasis> at <link xl:href="http://dx.doi.org/10.2165/00003088-200544100-00004"/>
          and its role in SUVlbm(Janma) calculation is discussed in <emphasis role="italic">Tahari et al. Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging. Journal of Nuclear Medicine. 2014 Sep 1;55(9):1481–4. </emphasis> at <link xl:href="http://jnm.snmjournals.org/content/55/9/1481"/>.
          The patient size correction factors are summarized here, where weight is in kg and height is in cm:</para>
        <para xml:id="para_211f1841-764d-481b-9165-4ecdd3a55a15">SUVbw: males &amp; females: weight</para>
        <para xml:id="para_f990e628-8377-4a92-956a-651e70f6467f">SUVlbm (James): males : 1.10 * weight - 120 * (weight/height) ^2</para>
        <para xml:id="para_3571f8d2-e7b4-432b-9d54-bcb2d7d04342">SUVlbm (James): females: 1.07 * weight - 148 * (weight/height) ^2</para>
        <para xml:id="para_e2a6e64d-3ff4-47a5-a98a-6ad1b6d9cf57">SUVlbm(Janma): males: 9.27E3 * weight / (6.68E3 + 216 * weight / (height^2))</para>
        <para xml:id="para_e2a91fde-1a50-470a-b114-11ac3a433ff9">SUVlbm(Janma): females: 9.27E3 * weight / (8.78E3 + 244 * weight / (height^2))</para>
        <para xml:id="para_7454a1df-dcc9-4492-b521-ddd007870a34">SUVbsa: males &amp; females: weight^ 0.425 * height^0.725 * 0.007184</para>
        <para xml:id="para_0418a618-881c-4ce1-8f86-1673ade9ebb7">SUVibw: males: 48.0 + 1.06 * (height - 152)</para>
        <para xml:id="para_33526356-6ca9-424a-a9bc-9095a7367e65">females: 45.5 + 0.91 * (height - 152)</para>
      </note>
    </section>
    
    
  </chapter>
</book>