    <title>CP-1619</title>
    <subtitle>Add source mouse strain and genetic modifications for homograft to exogenous substances</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2017/01/24</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>WG 30</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2016/03/23</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1619</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add source mouse strain and genetic modifications for homograft to exogenous substances, and add genetic modifications to patient</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.6, PS3.16 2016e</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Some preclinical animal models are described by investigators in terms of the designated genetic modifications but a full description of the mouse strain is not available; add attributes to the Patient entity in images to describe these.</para>
                    <para>Some models involve the transplantation of tissue from another animal that has been genetically modified, but the transplant is into the wild type animal that is then imaged. The wild type is properly described in the Patient attributes for the acquired images, but there is not currently any means of describing the strain or genetic modifications of the source of the transplant; extend the exogenous substances template to describe the strain and genetic modifications of the source.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <tr>
                    <td><para><emphasis role="italic">Amend DICOM PS 3.3:</emphasis></para></td>
                </tr>
            </informaltable>
        </section>

        <section label="C.2.3" status="3" xml:id="sect_C.2.3">
            <title>Patient Demographic Module</title>
            <table frame="box" label="C.2-3" rules="all" xml:id="table_C.2-3">
                <caption>Patient Demographic Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f485598-511d-492e-a3c7-79bfdd81ce68">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_523b87fe-c055-4338-9cb9-ff0cf657b37e">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e435214b-d609-43f9-be65-c66cd7d255ef">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9bc6680c-befc-4fbb-b598-f38cd006d6e2">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19cb32a0-0a70-4d9e-89f2-bb5991d80b03">...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1d9c8bed-5a01-4e96-9e19-5f020061b6b9">...</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e6fd4f52-c000-48f5-a2d5-47e30dcadd5c">Strain Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bafe77b9-9272-41d5-85c1-397fc3c0f3bd">(0010,0212)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8587fe96-f2cd-4f3d-b3b1-f639d6224653">The strain of the patient. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5cab0a7f-2487-4ca8-a093-58ae0ad25b90">Strain Nomenclature</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dfa5d3a9-b266-42de-be6d-e9e869ebbf5b">(0010,0213)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eb1a8550-fedf-4e1c-81bd-eeb6325f04b2">The nomenclature used for Strain Description (0010,0212). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d052a97c-7bc8-43f1-82bc-6d3d483c61d8">Strain Code Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dce7fd00-af3f-4589-a55e-84319dcfa717">(0010,0219)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c8d83fcc-8bdb-4d34-b9f0-98ae385406d1">A coded identification of the strain of the patient. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                            <para xml:id="para_5391e1c4-142b-4b19-a08b-14099d44e5ba">One or more Items are permitted in this sequence. If more than one item is present, each item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers).</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para xml:id="para_2a0933a9-b7c8-49d6-96ca-38bd90d083ef">
                                <emphasis role="italic">&gt;Include Table 8.8-1
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_89219f10-a940-4a8c-88e6-5e92b31f77bc">
                                <emphasis role="italic">No Baseline CID.</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_130f001e-a873-44e4-a21b-ccf0dede837e">Strain Additional Information</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e616ea9-a82c-4789-bfad-d10bf8aa04b9">(0010,0218)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88d3429d-6906-4e44-ade1-319d07ca2378">Additional information about the strain of the patient that is not encoded in the formal nomenclature used in Strain Description (0010,0212). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_96f01203-a532-4ee5-a278-5f03841251e9">Strain Stock Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1196d5fd-a2d7-47e3-97da-4d6031a33391">(0010,0216)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_14c46893-b5b4-4023-a125-470bee37d9ea">Information identifying an animal within a strain stock.</para>
                            <para xml:id="para_00a01cfa-6175-4e70-b3ce-123758ea364b">Only a single Item is permitted in this sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c03c5f76-aef1-4ca4-8e28-a5d6deee6f32">&gt;Strain Stock Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f30cfac-fa58-4b2a-8f74-a82b055b40d8">(0010,0214)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_80b512c8-74e6-45bc-8d9d-5646fd9f862a">The stock number of the strain of the patient issued by the organization identified by Strain Source (0010,0217). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aec59a7f-0a56-4604-b1ff-54542206cc3e">&gt;Strain Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff88a00d-84b6-4f35-b3a7-1acdd161bc87">(0010,0217)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_007e9010-e0b5-4506-b34e-d275a14a26ce">Identification of the organization that is the source of the animal, issued by the registry identified by Strain Source Registry Code Sequence (0010,0215). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_88e1f35b-5f46-4c7c-a900-22a4f99922b9">&gt;Strain Source Registry Code Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_25bfd164-90bf-4874-a575-84c0754cb194">(0010,0215)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b2a4bb50-8e47-485a-bc39-91b433e93f27">Identification of the organization that is the registry of sources of animals. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                            <para xml:id="para_0af2d8ef-1ce8-4ed5-820f-d324cfe74b15">Only a single Item is permitted in this sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para xml:id="para_d665e584-6a06-4274-9989-80fa5f617210">
                                <emphasis role="italic">&gt;&gt;Include Table 8.8-1
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e9f54199-8aab-4275-9b16-5cdd1d7ae4c6">
                                <emphasis role="italic">Defined CID 7490.</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0221)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">The genetic modifications of the patient.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Description</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0222)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">The genetic modifications of the patient described using a specific nomenclature.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Nomenclature</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0223)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">The nomenclature used for Genetic Modifications Description (0010,0222).</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0229)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">A coded identification of the genetic modifications of the patient.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this sequence. If more than one item is present, each item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers).</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">&gt;&gt;Include Table 8.8-1 </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">No Baseline CID.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="C.7.1.1" status="4" xml:id="sect_C.7.1.1">
            <title>Patient Module</title>
            <table frame="box" label="C.7-1" rules="all" xml:id="table_C.7-1">
                <caption>Patient Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3c32db2-8602-4023-89bb-3856b3c51c8e">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f7d731b-1fef-4474-81fb-bd2eb47efb40">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d036e51-8ab1-43d3-8460-77d97c7a5ff9">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53c874ba-0179-437b-86d0-406e872b2065">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5bf1f026-8432-4ae7-b5cd-1935b608d4cd">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_353153a4-93d9-455d-9cd3-4f9c0e6e5c3a">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4638255-baff-4e4c-aa74-ed52d49beb0e">...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_427a23ce-994c-4eb2-9cab-0c07583ec129">...</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f76feadf-d3d8-4790-b549-d1106c318766">Strain Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19d46ff5-57c2-4f1b-be04-c06ace85677e">(0010,0212)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3568d9af-f5ef-4875-a5cc-26dd3df4f191">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8421fbca-502e-4909-b03f-5789cda64935">The strain of the patient. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_26a2a91c-73e8-427b-a75a-e750284604fe">Strain Nomenclature</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e03d56f2-9745-4e63-b31f-d63cf5e2185b">(0010,0213)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_06430dbe-fc00-40ad-808e-85771e82bd04">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ea1c4023-3354-45aa-b770-e942796f32f3">The nomenclature used for Strain Description (0010,0212). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3b80e074-7bb6-4f12-93d0-4db8581dfa15">Strain Code Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38a4541c-3bc1-4563-8dab-1d6157c4ec93">(0010,0219)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddaa7b36-a3d8-475d-8cad-12b7f4c1d982">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_23ef1638-a6f9-45d2-99da-4446fcd29527">A coded identification of the strain of the patient. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                            <para xml:id="para_6189a2a0-f478-4e2b-be5a-bf7db631610e">One or more Items are permitted in this sequence. If more than one item is present, each item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers).</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_8d9dff82-a4f6-4e1d-a588-f71b758874e1">
                                <emphasis role="italic">&gt;Include Table 8.8-1
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f617bbdf-eca3-4513-a56f-0d14c85a1f3a">
                                <emphasis role="italic">No Baseline CID.</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0c36fad4-3086-4294-a219-b747e9fcc07f">Strain Additional Information</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7f4711e-2f08-4c88-98c3-8c61910ed838">(0010,0218)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9a53049c-a837-4885-867d-f47496336f4e">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_21b69572-0ae1-4997-87a8-9adab52f14ad">Additional information about the strain of the patient that is not encoded in the formal nomenclature used in Strain Description (0010,0212). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4382f21f-7a26-4d99-917d-2af4196a56eb">Strain Stock Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cd13f11-6131-481f-9408-4329c4d9f781">(0010,0216)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42ac24e9-2d92-413a-b9e5-4a02cc7b916b">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_211fe8ce-361a-4d1d-8fa7-bb170c1beb35">Information identifying an animal within a strain stock.</para>
                            <para xml:id="para_042b69c4-fd32-4666-b6c7-d9f608a07305">Only a single Item is permitted in this sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d1d1ed10-da17-4a8b-afa4-7a030dffe912">&gt;Strain Stock Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_17d6793a-2d21-4159-bb9b-f8d81ad71429">(0010,0214)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f0a8d5a-d80c-4ede-8b91-c1ffc584f5eb">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_158a4687-a206-4636-b2c2-ca9ef049bd58">The stock number of the strain of the patient issued by the organization identified by Strain Source (0010,0217). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_11252d2d-143b-42fc-b152-57902f2c2cde">&gt;Strain Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_659e4062-37d9-4f19-a2b1-1e07651822c9">(0010,0217)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0170493-ae24-4349-931a-5b196e9ddf43">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e602d4a9-a774-4623-8492-6bd2c1f27825">Identification of the organization that is the source of the animal, issued by the registry identified by Strain Source Registry Code Sequence (0010,0215). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_005c11a2-1f75-49d4-9e14-93196424aefb">&gt;Strain Source Registry Code Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89b10df7-31b5-4b2f-a95b-78f8bc2f0bec">(0010,0215)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2b5e5165-9797-4db9-b5a5-e8fb514f3688">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_01c9cf7a-1c6c-44f3-a961-398645ba3789">Identification of the organization that is the registry of sources of animals. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                            <para xml:id="para_9eed1e69-84b2-4031-aab0-a63568f737bf">Only a single Item is permitted in this sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_ab494445-9863-4318-bed3-b397066f2cbc">
                                <emphasis role="italic">&gt;&gt;Include Table 8.8-1
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_78557ec3-fcee-45ae-b867-09edfd333603">
                                <emphasis role="italic">Defined CID 7490.</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0221)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">The genetic modifications of the patient.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Description</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0222)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">The genetic modifications of the patient described using a specific nomenclature.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Nomenclature</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0223)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">The nomenclature used for Genetic Modifications Description (0010,0222).</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0229)</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">A coded identification of the genetic modifications of the patient.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this sequence. If more than one item is present, each item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers).</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">&gt;&gt;Include Table 8.8-1 </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="bold"><emphasis role="underline"><emphasis role="italic">No Baseline CID.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c15a4781-8cb2-422a-9c64-8b4a097f37bb">Responsible Person</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f6b3ecb9-c04b-49be-8467-50ed23f70165">(0010,2297)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f290879b-7e71-4442-9fd0-4f867dcc1dc1">2C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_580b04f7-c155-47ec-b706-adce0b6e62df">Name of person with medical or welfare decision making authority for the patient.</para>
                            <para xml:id="para_e5da03bf-9169-42e0-bce6-1254942d833a">Required if the patient is an animal. May be present otherwise.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_90be565d-9cad-4150-978f-05c2b3631c21">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_230d7c9a-177a-4c82-b674-c3026f957f21">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_529e26aa-2aaf-49ad-a8b8-d67978c50fe9">...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5d90c80e-b629-45cc-86ea-faa123eaa92c">...</para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="C.7.1.1.1" status="5" xml:id="sect_C.7.1.1.1">
                <title>Patient Module Attributes</title>
                <section label="C.7.1.1.1.4" status="6" xml:id="sect_C.7.1.1.1.4">
                    <title>Patient Strain<emphasis role="bold"><emphasis role="underline"> and Genetic Modifications</emphasis></emphasis></title>
                    <para xml:id="para_85d70a75-8634-4a5c-bd35-edf49db2ec03">The strain of an animal (group of animals that is genetically uniform), if known, may be encoded in Strain Description (0010,0212). The nomenclature used may be encoded in Strain Nomenclature (0010,0213). A precoordinated code identifying the strain may be encoded in Strain Code Sequence (0010,0219).</para>
                    <variablelist>
                        <title>Defined Terms for Strain Nomenclature (0010,0213)<emphasis role="bold"><emphasis role="underline"> and Genetic Modifications Nomenclature (0010,0223)</emphasis></emphasis>:</title>
                        <varlistentry>
                            <term>MGI_2013</term>
                            <listitem>
                                <para xml:id="para_c063adab-6f7b-4e33-bf93-8cb2e6abe8de">International Committee on Standardized Genetic Nomenclature for Mice, Rat Genome and Nomenclature Committee. MGI-Guidelines for Nomenclature of Mouse and Rat Strains. 2013/10. Available from: <link xl:href="http://www.informatics.jax.org/mgihome/nomen/strains.shtml"/>
                                </para>
                            </listitem>
                        </varlistentry>
                    </variablelist>
                    <note>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_9e9daf70-3220-4060-b141-f3ddc06fb8a4">A pair of text and nomenclature Attributes are used, since standard nomenclatures typically define values that are constructed from multiple components, and do not distinguish between value and meaning. These are distinct from the precoordinated codes used in Stain Code Sequence (0010,0219).</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_24331c93-21a6-42d3-82ae-fcd877e900bd">Some strain <emphasis role="bold"><emphasis role="underline">and genetic modifications</emphasis></emphasis> nomenclatures make use of superscripts. To encode these superscripts consistently in an unformatted string, the convention of enclosing the superscript text in "&lt;" and "&gt;" pairs may be used. E.g., "D2.B6-Ahr<superscript>b-1</superscript>/J" would be encoded as "D2.B6-Ahr&lt;b-1&gt;/J".</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_cb2e3eea-c8eb-40fc-b5f8-ba73a9b777a1">Relevant information that is not encoded in the formal description of the strain (i.e., not defined in the nomenclature used), such as the number of transgenes, may be encoded as plain text in Strain Additional Information (0010,0218).</para>
                            </listitem>
                        </itemizedlist>
                    </note>
                    <para xml:id="para_d6ad9008-83de-4efa-9b51-f95f88ea0f60">The strain of an animal may be more specifically identified by the Attributes within Strain Stock Sequence (0010,0216).</para>
                    <note>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_f409affe-78e3-4c74-8070-a846a734c186">The MGI-Guidelines for Nomenclature of Mouse and Rat Strains recommends the use of the laboratory codes assigned by the Institute of Laboratory Animal Research (ILAR). See the International Laboratory Code Registry (ILCR) <link xl:href="http://dels.nas.edu/global/ilar/lab-codes"/>.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_6261cd3c-beff-4de1-b4b4-f9d1666c4b5f">Because allele names are closely tied to gene names/symbols it is necessary to have a unique and permanent code for any allele that is part of a genotype of interest. For mice, MGI is the authoritative source of the nomenclature for genes and alleles and maintains unique, permanent codes for these entities. The MGI provides a report of all precoordinated MGI codes that are assigned to specific strains at <link xl:href="ftp://ftp.informatics.jax.org/pub/reports/MGI_Strain.rpt"/>. These may be used in Strain Code Sequence (0010,0219) <emphasis role="bold"><emphasis role="underline">and Genetic Modifications Code Sequence (0010,0229)</emphasis></emphasis> with a coding scheme of "MGI".</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_30cc1156-109a-410f-a675-0bcb907028e3">Another source of pre-coordinated codes for strains is the NCI Thesaurus, which includes a snapshot of strains from the International Mouse Strain Resource (IMSR), as children of (C14421, NCIt, "Inbred Mouse Strains"). See <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/pages/concept_details.jsf?dictionary=NCI_Thesaurus&amp;code=C14421"/>.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_988a9746-b8f8-499e-bdd5-d49c342bd3fa">For example, a C57BL/6J mouse strain from The Jackson Laboratory might be identified as:</para>
                                <itemizedlist>
                                    <listitem>
                                        <para xml:id="para_2f7d373c-a827-464b-b902-1a2a6790981e">Strain Description (0010,0212) = "C57BL/6J"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_c6bca708-6096-4264-92fa-45de6546a7d4">Strain Nomenclature (0010,0213) = "MGI_2013"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_05207449-5da6-4722-9710-c4db80c0f7c5">Strain Code Sequence (0010,0219)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_7b4a0cea-2291-4f1e-bd96-1ebba9c43e80">&gt;Code Value = "3028467"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_4494416e-08de-4992-a77d-2c6187563f76">&gt;Coding Scheme Designator = "MGI"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_3cce13d5-d827-41bc-ad81-c561d8379da2">&gt;Code Meaning = "C57BL/6J"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_b5577544-e85a-412f-9ec3-c96b04671b58">Strain Stock Sequence (0010,0216)</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_c36db518-148b-4f27-bc19-bd227f9caf06">&gt;Strain Stock Number (0010,0214) = "000664"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_047ee409-a924-4772-ab89-45e244cb6966">&gt;Strain Source (0010,0217) = "Jrep"</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_8f9aa498-68c2-484d-a200-9c3ac35ffb63">&gt;Strain Source Registry Code Sequence (0010,0215) = <olink targetdoc="PS3.16" targetptr="DCM_126850" xrefstyle="select: nopage">(126850, DCM, "ILCR")</olink>
                                        </para>
                                    </listitem>
                                </itemizedlist>
                            </listitem>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">For example, a FVB/N mouse with a Tg(MMTV-Erbb2*)NDL2-5Mul transgene might be identified as:</emphasis></emphasis></para>
                                <itemizedlist>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">Strain Description (0010,0212) = "FVB/N-Tg(MMTV-Erbb2*)NDL2-5Mul"</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">Strain Nomenclature (0010,0213) = "MGI_2013"</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Sequence (0010,0221)</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Description (0010,0222) = "Tg(MMTV-Erbb2*)NDL2-5Mul"</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Nomenclature (0010,0223) = "MGI_2013"</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">&gt;Genetic Modifications Code Sequence (0010,0229)</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;Code Value = "3793949"</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;Coding Scheme Designator = "MGI"</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;Code Meaning = "Tg(MMTV-Erbb2*)NDL2-5Mul"</emphasis></emphasis></para>
                                    </listitem>
                                </itemizedlist>
                                <para><emphasis role="bold"><emphasis role="underline">In this example, a precoordinated code for the genetic modification is defined in MGI, but not for the mouse strain.</emphasis></emphasis></para>
                            </listitem>
                        </itemizedlist>
                    </note>
                </section>
            </section>
        </section>

        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <tr>
                    <td><para><emphasis role="italic">Amend DICOM PS 3.6:</emphasis></para></td>
                </tr>
            </informaltable>
        </section>

        <section label="6" status="1" xml:id="chapter_6">
            <title>Registry of DICOM Data Elements</title>


            <table frame="box" label="6-1" rules="all" xml:id="table_6-1">
                <caption>Registry of DICOM Data Elements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e8c52d5-3582-4ec4-a7e6-acd7604caf32">
                                <emphasis role="bold">Tag</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac298c3b-bcdd-462b-9240-c38e738bfb7c">
                                <emphasis role="bold">Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99f6b0ff-e1b0-484e-83b5-c3003d61704c">
                                <emphasis role="bold">Keyword</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42b3621d-8b30-46eb-8992-10bb21310ac7">
                                <emphasis role="bold">VR</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_551ea829-a949-4bfd-a201-bb102024e64c">
                                <emphasis role="bold">VM</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a18713f-2e81-4664-b9a1-e4e3d41957ab"/>
                        </th>
                    </tr>
                </thead>
                <tbody>

                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f626a063-be40-4801-b771-3a3195078335">(0010,0212)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_790f59d0-0451-4133-ae3e-8312d1a69602">Strain Description</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_70b761ab-1655-4b06-ad4f-85db4512612e">Strain​Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2427a33-691d-4dae-86fd-b1ea139cb891">UC</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a2f553c-45c7-4d73-86f1-0eb3a6d97f56">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11432e64-b238-43f2-b850-9b977d974c24"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_89eb9e60-fdf0-48e7-89c6-4bfeceef2536">(0010,0213)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9727aa24-5bd7-47af-bf7b-91a743c900b4">Strain Nomenclature</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ca4e9662-e9c9-445a-bb26-3f2d0f741e97">Strain​Nomenclature</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_436430b5-84d8-4a4c-8257-a723bf0cc5c7">LO</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fdb6aabb-e455-48f0-8ae3-8ac5c5c8be67">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c4dfd39-e8fa-4231-87b0-3938e3f5ce1b"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f33b58b3-614e-4757-89c8-538c1960d03e">(0010,0214)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6e701e25-9f32-49e6-bdd7-19cf3ab60fa2">Strain Stock Number</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c451a735-24cc-4dd3-bb2f-7ff46af1cee0">Strain​Stock​Number</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e1cb7e6-19ee-448e-992a-30226d7b59ed">LO</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47c069fd-3569-46ef-b799-06edeb57f561">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_59379f79-4d33-440e-b9cd-15632eba72a3"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_43222bb7-5a0f-43f9-bfed-95bcd51ce5c2">(0010,0215)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_817720b1-c3f6-4cc6-80fb-53a5dfdb466d">Strain Source Registry Code Sequence</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a812da72-5495-4219-af48-0568bad7b55a">Strain​Source​Registry​Code​Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b37bf7a9-2777-4018-b148-db291fe4486a">SQ</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2a218a35-6423-437b-af7c-d44585887953">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3565e91d-54df-4f4f-8257-179b5957eb91"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6e6bc8ac-4b88-4d0f-8cf9-3c2445a8903a">(0010,0216)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ffa98d1-293c-4d36-bc27-f71e4e1c96a1">Strain Stock Sequence</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9460275a-67c1-446b-af7b-cb96dbdea3cb">Strain​Stock​Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c4df29c4-0121-43d3-a8cf-ee6a9ca892db">SQ</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1abf24e6-b0f1-481f-9b25-1e55c34199e7">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_81e7b092-0af6-400b-b6d3-f0b5af91829f"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29b855eb-d5a7-4289-b7b6-508006d8d44e">(0010,0217)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_86cc6a93-b9d9-4e86-b338-6d5c1337c7c4">Strain Source</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c7922abf-a81e-4ef2-a89f-33b2e4893eba">Strain​Source</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_160344fe-a5d0-476b-9060-06677ceb4879">LO</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_57012b45-0d3b-4219-b908-e6a5969bebdf">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f0ce96c-62fc-41d3-ab13-66e5fe3a6054"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6851f815-6b65-4a35-b674-11eadb33906a">(0010,0218)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_264c20a2-6668-4441-94fb-c8205a68de0c">Strain Additional Information</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9414b933-2a38-4c97-8118-5f490b9864ba">Strain​Additional​Information</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9eefe8a-fe6b-4372-8807-9b9da8384097">UT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50a09a30-ad81-4ec9-a8d9-66a7047a9c45">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21531231-d3d5-4749-9b24-f26fa3f5a9f2"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0943e7cd-302a-4c74-8728-973f4d0689af">(0010,0219)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_251451d1-6612-4cb8-a935-16f05071c4e8">Strain Code Sequence</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6a2d781-2bc9-488e-b83b-6be42dadb11a">Strain​Code​Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e3e4fb6-a11b-4f8c-9dff-839c512057fd">SQ</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e1204185-cc7e-469c-850a-0961d1d9392a">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d2a1d21-5f58-4311-8b78-e127bb2d2d81"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0221)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic​Modifications​​Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0222)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Description</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic​Modifications​Description</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">UC</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0223)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Nomenclature</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic​Modifications​Nomenclature</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">LO</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,0229)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic Modifications Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic​Modifications​Code​Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section>
            <title/>
            <informaltable rules="all" frame="box">
                <tr>
                    <td><para><emphasis role="italic">Amend DICOM PS 3.16:</emphasis></para></td>
                </tr>
            </informaltable>
        </section>

        <section label="TID 8182" status="3" xml:id="sect_TID_8182">
            <title>Exogenous Substance Administration</title>
            <table frame="box" label="TID 8182" rules="all" xml:id="table_TID_8182">
                <caption>Exogenous Substance Administration</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04c8dd40-29fc-4e12-9473-79d800e3f12a"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af829b44-e4f9-498c-88fb-961670cf632b">
                                <emphasis role="bold">NL</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d87d6ee1-a3f2-4863-86e5-42b50f9bcfb6">
                                <emphasis role="bold">Rel with Parent</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c884b98-6b74-40a9-b0cd-87817c3cded4">
                                <emphasis role="bold">VT</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb99ade2-1e92-4161-af04-d33f0a92d422">
                                <emphasis role="bold">Concept Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_54c8affb-b9fc-45ae-a837-f32038f80a10">
                                <emphasis role="bold">VM</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_622e5ff8-9de7-44de-a011-7593f9bb16f4">
                                <emphasis role="bold">Req Type</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f8dcf0b-ac28-4765-b943-99cc04b2d5aa">
                                <emphasis role="bold">Condition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82eb56ab-c120-4b44-9f49-3e0b684b7016">
                                <emphasis role="bold">Value Set Constraint</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c8969957-c9a2-4244-9ad2-3be649c13613">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4e49a554-97eb-4ce1-a8cd-564d6b3fea8c"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27c928f2-c1eb-4c10-8c82-276b2a8cda46"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fa2ac69d-5f7e-4710-b2b8-7e370709c434">CONTAINER</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6d9b1ec6-685e-45e6-bfdc-e2d7b499d006">$ContainerConcept</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e79b55b3-1c9e-4c03-b6f1-d95a009c2311">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_894d60e7-b4c9-48d9-a392-062ae749fa7d">M</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_419d9523-5262-4cb2-82f6-b7732af7e312"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2262fc01-a910-4b44-91a4-3244057807fc"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_032bfe58-22b7-43e5-ad21-94997aaaac6b">2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a9810d54-096a-4e34-9319-99878e07b7a2">&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7eb18101-4f2f-4431-965a-e09de6cb4b97">CONTAINS</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_192ac78a-044a-48c1-8fd2-0251ba013aeb">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_15d982b9-3163-44e7-9e79-2fb1abd470b2">$CodeConcept</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f717db7e-53b7-4111-87f4-cc7a9e0fb8c4">1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53d3e0b6-886b-4ff6-8938-e3746e750106">M</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1a276b3e-2da8-4ed3-8e4c-36e21fee59ff"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6e06b4df-30c9-4b45-88dc-2472a5b7d5ab">$CodeValue</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>20</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7708ca59-b544-45cb-b18e-b27e731fd38f">&gt;&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3a67df37-8cde-4335-b395-c72f4eaeacdf">HAS PROPERTIES</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_24c5d70e-76fe-4bcb-8e1e-794c8fd5dfe4">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b9ae6cb7-8752-4be3-8129-39f4e0612cb4">EV <link linkend="DCM_127401" xrefstyle="select: nopage">(127401, DCM, "Tissue of origin")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b19dead7-244e-489d-bf72-d7d241b66d00">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3580f258-dc64-425e-b01a-208b29558f91">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5c95262b-d18f-40cf-adb5-304f49cb8294"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b1f2c996-6ec8-4881-85be-c867ee92e21d">$TissueOfOrigin</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para>21</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_528d385c-c49f-4c66-837e-d346435d47a7">&gt;&gt;</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_326e4abd-f544-4235-8591-94b3d04cbf98">HAS PROPERTIES</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_30ac9f24-ffc1-487c-b6a9-fbc1f644049f">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f1b4011f-adc0-4dc8-a66d-800228022ee2">EV <link linkend="DCM_127402" xrefstyle="select: nopage">(127402, DCM, "Taxonomic rank of origin")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_345e4192-d0e7-4cdd-88df-f11d33542b3f">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9cb19e3-8ee6-4ddc-b47d-52dd5e33ec21">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4889c591-2049-413b-b47f-75f5b9262699"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_30c7d924-d33e-48a6-85e4-1250b1a5f78d">$TaxonomicRankOfOrigin</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">22</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">EV <link linkend="DCM_127411" xrefstyle="select: nopage">(127411, DCM, "Strain")</link></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">23</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">EV <link linkend="DCM_127412" xrefstyle="select: nopage">(127412, DCM, "Strain description")</link>
                                    </emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">24</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS CONCEPT MOD</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">EV <link linkend="DCM_127413" xrefstyle="select: nopage">(127413, DCM, "Nomenclature")</link></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">25</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">EV <link linkend="DCM_127415" xrefstyle="select: nopage">(127415, DCM, "Genetic modifications description")</link></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1-n</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">26</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS CONCEPT MOD</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">TEXT</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">EV <link linkend="DCM_127413" xrefstyle="select: nopage">(127413, DCM, "Nomenclature")</link></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">27</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">&gt;&gt;&gt;</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">CODE</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">EV <link linkend="DCM_127414" xrefstyle="select: nopage">(127414, DCM, "Genetic modifications")</link></emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para xml:id="para_4b58538c-3264-49ca-b84e-fbe7bab64f08">
                <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr>
                        <td align="left" colspan="1">Row 3</td>
                        <td align="left" colspan="1">Classification is inherited from the more general template TID 9002, and may be supplied as a parameter, but is entirely generic and is not used as an alternative to the more specific information provided in other rows, for example, Rows 19 and 20, tissue and taxonomic rank of origin.</td>
                    </tr>
                    <tr>
                        <td align="left" colspan="1">Row 11</td>
                        <td align="left" colspan="1">Brand name may be used for any type of descriptor or identifier. E.g., a particular cell line might have a designated name, such as "MDA-MB-468", which designates a particular human breast cancer cell line.</td>
                    </tr>
                    <tr>
                        <td align="left" colspan="1"><emphasis role="bold"><emphasis role="underline">Rows 22-27</emphasis></emphasis></td>
                        <td align="left" colspan="1"><emphasis role="bold"><emphasis role="underline">These rows describe the strain and genetic modifications of the source of the graft using content items that correspond to the Attributes described in <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>. The strain and genetic characteristics of the animal into which the exogenous substance is grafted are described in the Patient Module; see <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>. </emphasis></emphasis></td>
                    </tr>
                </tbody>
            </informaltable>
        </section>

        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
                                <emphasis role="bold">Code Value</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
                                <emphasis role="bold">Code Meaning</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
                                <emphasis role="bold">Definition</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
                                <emphasis role="bold">Notes</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_127411"><emphasis role="bold"><emphasis role="underline">127411</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Strain</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">An identifier of a group of animals that is genetically uniform.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_127412"><emphasis role="bold"><emphasis role="underline">127412</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Strain description</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">A description of a group of animals that is genetically uniform.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_127413"><emphasis role="bold"><emphasis role="underline">127413</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Nomenclature</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">A system of names or descriptions used in a particular field.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_127414"><emphasis role="bold"><emphasis role="underline">127414</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic modifications</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">An identifier of a specific variation of a targeted gene or introduced transgene.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_127415"><emphasis role="bold"><emphasis role="underline">127415</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Genetic modifications description</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">A description of a specific variation of a targeted gene or introduced transgene.</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>

        </section>