<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1526</title>
  <subtitle>Correct order of reference to pixel spacing values in SR Image Library</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2016/03/14</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
          xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier</para><para><link
          xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:mail@jriesmeier.com"/></para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2015/08/21</para></td>
      </tr>
    </informaltable>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1526</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct order of reference to pixel spacing values in SR Image Library</para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Name of Standard</para>
          <para>PS3.16 2016a</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Rationale for Correction:</para>
          <para>Sup 50 (Mammo CAD) introduced the concept of an Image Library, which contains descriptions of relevant Attributes of images extracted from the images. This included pixel spacing information, which in images is contained in a single multi-valued Attribute, whereas in SR, spacing is split into separate horizontal and vertical content items. The concept of an Image Library has been reused in other CAD and measurement applications, and the same concepts used in other templates.</para>
          <para>In specifying the source of which value was horizontal and which vertical when copying into the separate concepts, the order was specified opposite that of the PS3.3 definition.</para>
          <para>CP 626 was intended to clarify once and for all the (not terribly clear) PS3.3 Attribute description, which is "specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing", but only addressed the description in PS3.3. CP 626 uses the same words as the names of the SR concepts ("horizontal spacing" and "vertical spacing").</para>
          <para>In practice, pixels are almost always square, so no issue is encountered in the installed base when using the values (e.g., for measurements), but the order in PS3.16 should be corrected.</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
      </tr>
    </informaltable>
  </chapter>
  <chapter>
    <title/>
    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td><para><emphasis role="italic">Amend PS 3.16 to correct order of reference to spacing values</emphasis></para></td>
        </tr>
      </informaltable>
    </section>

         <section label="TID 1603" status="3" xml:id="sect_TID_1603">
            <title>Image Library Entry Descriptors for Projection Radiography</title>
            <para xml:id="para_5df46815-9377-4578-bbda-b6224d64fe9c">...</para>
             <table frame="box" label="TID 1603" rules="all" xml:id="table_TID_1603">
               <caption>Image Library Entry Descriptors for Projection Radiography</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3b86817d-6979-4682-8b78-096a8a6b3afa"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bcc4da96-f5a0-4e2c-8da3-24854d06de9a">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1bcce8f5-150f-41ae-9a2d-23eb9e746470">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f5c77ee3-3353-4052-a2e4-520f953582ad">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_05dfc679-67e0-4944-bf6b-76c2213e0f97">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_db5d1c0d-04fe-4d75-af76-ba258a93edd3">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7d7a1024-4b31-484d-97b3-47a76fbce065">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_be5280d2-1409-49c8-8267-e7adc5b898a8">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_46aafe31-c818-4258-b4d8-4e27978ecb01">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_27be1d08-febd-49f6-b8b4-9c4896747741">5</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_93362fda-1073-41b3-a930-f24e06ecc6ce"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8a464664-c75f-41f4-acd0-b5037c559f8d">HAS ACQ CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e580f06d-1db5-4849-9c7a-0b13792d7b87">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d0894c98-b957-4b4b-81ba-e8f2b913e344">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_012dc81b-a76f-4dc1-971f-1583f1064b23">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bf8f1aa0-d3ff-41a9-b108-806bfdca1464">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5c19ac87-026a-4d8c-8e6a-edd8bfb230a2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">UNITS = EV (mm, UCUM, "millimeter")</td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_232a24b6-d399-4218-a960-a0102529287a">6</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_364361dd-fb63-426d-9b98-25900af09bf5"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_36df9117-6de2-4df7-8968-5383f884aa5d">HAS ACQ CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ac464c73-87fc-432d-b886-176caae412a1">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e99e5c2e-a78c-4444-89d3-27ccd651ef8e">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4517d388-e4a8-49d5-b0bc-56770d048351">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2db120ed-d561-4f68-94c8-ab3e721f0480">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4154c864-4cc3-40b8-bf34-8722d09038b4"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ee574f48-a453-483d-993e-2a3b4e326581">UNITS = EV (mm, UCUM, "millimeter")</para>
                     </td>
                  </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
               </tbody>
            </table>
            <para xml:id="para_dd0edd05-05e9-4d87-9dfa-92898c1e1855">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_86b6b46e-1632-47ce-85d4-520f8d99163d">Horizontal Imager Pixel Spacing</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_1206f164-9b5f-481e-b34f-5e883699f7e4">The <emphasis role="bold"><emphasis role="strikethrough">row (first) </emphasis><emphasis role="underline">second</emphasis></emphasis> component of Imager Pixel Spacing (0018,1164) in the Image IOD. See <xref linkend="sect_C.8.11.4" xrefstyle="select: docname label quotedtitle"/>.</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cc9e6963-066c-4a83-b0c9-c3c8b4b14311">Vertical Imager Pixel Spacing</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a03aae36-7195-4ac6-8255-7c0f668358db">The <emphasis role="bold"><emphasis role="strikethrough">column (second) </emphasis><emphasis role="underline">first</emphasis></emphasis> component of Imager Pixel Spacing (0018,1164) in the Image IOD. See <xref linkend="sect_C.8.11.4" xrefstyle="select: docname label quotedtitle"/>.</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>
         <section label="TID 1604" status="3" xml:id="sect_TID_1604">
            <title>Image Library Entry Descriptors for Cross-Sectional Modalities</title>
            <para xml:id="para_443dfe9c-807d-4cf1-98b1-bc88923036fd">...</para>
            <table frame="box" label="TID 1604" rules="all" xml:id="table_TID__1604">
               <caption>Image Library Entry Descriptors for Cross-Sectional Modalities</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bda0ceb7-f4d0-4dd7-895e-e767a0031301"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_abd0f3c0-8a9b-4f13-ab32-da0423793bdc">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_74c72875-0a96-4dc6-8fb6-d3755193673e">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3a891da1-6f02-43b4-91cf-51221927d8a7">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_640b51f8-5c02-4508-8904-90376e7f7a14">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7adb1bb8-f826-4a2d-b840-97358b0d0e4e">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8a597138-2302-4fa1-9320-652f464438f0">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_975e3782-73b6-4561-ae12-7fffe23f7b4d">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f183400d-95a0-4c31-90ea-b49857fbf6de">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_2075179e-6291-459a-b532-0236528744e5">1</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d321603b-aa5b-4001-b56a-fbc4b37af417"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_70fb6039-dffb-4d0d-afdd-936275d4a1ce">HAS ACQ CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d83eb28d-6880-421f-8bc9-1567d4306359">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a0605a52-f49f-429e-9fcf-dfa3b567ab10">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9ce470a7-1cbf-41b1-870e-941f52e1db08">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c69cf7d1-3c43-4bd1-b341-390911d3dd64">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_4c7b25db-c3cd-4b70-ba4b-9f670d8e147f"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">UNITS = EV (mm, UCUM, "millimeter")</td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e4a85be2-2b9f-4194-b879-c5b4fb024b75">2</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_407a17e1-3a1b-4c76-9af5-5dc4fbf2574c"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cadef7ae-e259-4b78-8435-181d42e5754d">HAS ACQ CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_071fae9d-4fbf-4a8f-80b7-d7c94945dd99">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d166e48f-eaed-49ca-98e9-8024577e2458">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3314a9b3-187a-4abf-b019-dd553bee2459">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_812227e2-4c19-41c8-ac0b-aa74195f3d9b">U</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cba992be-d96d-4937-9e7d-17f69dbbb830"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_53010689-ab88-4fb0-b4d3-08f603c56006">UNITS = EV (mm, UCUM, "millimeter")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para>...</para>
                     </td>
                  </tr>
               </tbody>
            </table>
            <para xml:id="para_e1a96803-e5c4-4885-b9e5-a5bf07439066">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8b47db5a-f9e5-4ec7-b4b2-7430c86f7734">Horizontal Imager Pixel Spacing</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_52b7402f-b0d9-4cf7-a51a-3cc2253971f5">The <emphasis role="bold"><emphasis role="strikethrough">row (first) </emphasis><emphasis role="underline">second</emphasis></emphasis> component of Pixel Spacing (0028,0030) in the Image IOD. See <xref linkend="sect_10.7.1.1" xrefstyle="select: docname label quotedtitle"/> and <xref linkend="sect_C.7.6.2" xrefstyle="select: docname label quotedtitle"/>.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_511134ca-56ba-4af5-bef5-be6e839406ff">Vertical Imager Pixel Spacing</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_49652884-f1ea-4160-bd33-a7342bcaeb31">The <emphasis role="bold"><emphasis role="strikethrough">column (second) </emphasis><emphasis role="underline">first</emphasis></emphasis> component of Pixel Spacing (0028,0030) in the Image IOD. See <xref linkend="sect_10.7.1.1" xrefstyle="select: docname label quotedtitle"/> and <xref linkend="sect_C.7.6.2" xrefstyle="select: docname label quotedtitle"/>.</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>

         <section label="TID 3205" status="3" xml:id="sect_TID_3205">
            <title>Calibration</title>
            <para xml:id="para_5fcc802d-8ab0-442c-a5c3-4a7bd8269733">...</para>
            <table frame="box" label="TID 3205" rules="all" xml:id="table_TID_3205">
               <caption>Calibration</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5ed1a3cc-34fe-4974-bca1-0ef8a3deb7a3"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2b61c7ff-9ee2-415f-b6b0-459d0cbfd8fb">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3dd17481-854c-4b6c-a6f5-5ba1d8dc2795">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_69fc5a09-290c-44d5-a0f8-2878f80cdd6a">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_87d774c3-586d-4ddd-9219-5dbbd6e33e0e">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9e689bcc-bd33-4cb4-9471-18f99d36a2f6">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6a260b39-911c-4636-8dc3-6451c9b33012">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b9eae925-660a-4b9d-a65b-d8474720c797">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a31b4f32-1023-4d0d-8901-1bb53c985610">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_627bcb4e-5c6e-41f8-9209-1883e2138b5b">9</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fcc4ab4d-2a07-4519-a5bf-057c32f8284b">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7ed2ab6e-8ee2-4d90-80ef-e78acdde0b25">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6913af70-ad14-47ef-8b68-29698a5e744a">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b6e1752b-2582-4175-8123-4d2439ce203e">DTID 300 "Measurement"</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e77e5af3-ca83-46d2-8ca4-192a2ad88130">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1426be32-342f-4316-a4cb-780c1447e420">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_d7c2de7e-889f-49e4-ad76-5a4e576e6ff9"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_11cbd94c-6d88-40c8-8d09-77b2bdbcec85">$Measurement = EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                        </para>
                        <para xml:id="para_0b80cd80-f651-4818-849f-6598eaaa65a4">$Unit = DT (mm/{pixel}, UCUM, "mm/pixel")</para>
                        <para xml:id="para_e48eb030-e280-4797-90da-739da4d29d58">$ImagePurpose = EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                        </para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7a77458f-4166-420c-8ccc-93c585828934">10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_50677fe3-aa28-40c6-ad11-78158e4721b2">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3cc7eaeb-2571-4a07-b4de-56d155bb7d6d">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_55ded2a6-8b10-46ea-98f1-77daaf5d5ac6">INCLUDE</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para xml:id="para_0dc6dc49-e87d-4486-9ad8-350c57ddc423">DTID 300 "Measurement"</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_153c2dac-b1e7-4923-ace0-fd406e3ca80a">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4cc98275-b4ec-4463-a0fe-f3beede792e8">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9387c605-cb85-433f-a3b6-5cbbff99e8c1"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f47b837b-ca86-4c85-9581-5a8c984be7e3">$Measurement = EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                        </para>
                        <para xml:id="para_65a0d80c-15de-4dfc-9003-c1850977e179">$Unit = DT (mm/{pixel}, UCUM, "mm/pixel")</para>
                        <para xml:id="para_72c8548d-ae1b-4dc6-b6e7-a6d330c9efe8">$ImagePurpose = EV <link linkend="DCM_121112" xrefstyle="select: nopage">(121112, DCM, "Source of Measurement")</link>
                        </para>
                     </td>
                  </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
               </tbody>
            </table>
            <para xml:id="para_4a696260-f2e5-45b8-8ed9-3f8c8b3aba08">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7a9d95d2-c93e-4424-8200-7ee164d3f4bd">Row 9, 10</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para xml:id="para_c6129971-6d79-4e3b-9c44-3567945bb559">Spacing in the patient body. Point to a single frame containing the image used for calibration if applicable, the actual measurements may be indicated by a SCOORD (see TID 320 "Image or Spatial Coordinates", row 3)</para>
                     </td>
                  </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
               </tbody>
            </informaltable>
         </section>

         <section label="TID 4020" status="3" xml:id="sect_TID_4020">
            <title>CAD Image Library Entry</title>
            <para xml:id="para_784fbba2-718f-471e-8cdc-bd6d5d8f0a04">...</para>
            <table frame="box" label="TID 4020" rules="all" xml:id="table_TID_4020">
               <caption>CAD Image Library Entry</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_bd5bc77d-c14d-4bb4-845c-beb446115f86"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_18ea18b6-f1b6-43cb-80e3-ada03c92bdbe">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_65e67a0e-2e92-470c-b92d-d2401f3fab6e">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b1732f6-e981-4ffe-80d1-a196cf3067f6">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_52410d1f-5f3d-4867-89d5-f3c3a3f3e6d3">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4b0c9c52-56ba-45bb-9f0c-4265865a2518">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3d720175-2b6b-4828-9d2e-dfca5d94391d">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_90bae223-264d-4e1e-a8ca-05c7489fe047">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fbaf59da-fdc6-4ca4-bc29-0d7ae4872b64">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_61b0c774-07be-4bef-afed-bae13f57a21e">11</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_21c2bc1f-ca0e-46a5-8523-bfb5491917cc">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_701a3885-a220-4ed3-b479-fb80977113ea">HAS ACQ CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_f1d11582-a352-4ed3-a528-d20a7ba1ee95">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_db155191-5a28-4f84-b479-9ca0a9154e0b">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ca0cf9e7-a8b4-44f0-b5e1-c436c5234ebe">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f247637c-2e01-4887-8809-9c195c3641f3">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_42e767e4-b43c-4797-9c58-d42e2e5c0f43">Shall be present if (0018,1164) or (0028,0030) is in the Image Instance</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3674c8b6-69ff-4fba-85f4-115a1712c692">UNITS = EV (um, UCUM, "micrometer")</para>
                        <para xml:id="para_ebc2a77e-e419-4d5f-b8db-bc9ef74bae96">UNITS = EV (mm, UCUM, "millimeter")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c30ad523-9a46-4ace-a501-9401d9cc47f1">12</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bad1ca52-ca91-44eb-85be-79963f2b4409">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b012dcf9-e430-4c9b-b433-e0f3e0b79636">HAS ACQ CONTEXT</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a8e2ffc3-ff9d-4909-b144-37b77b37f593">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a570babb-189f-46dc-b9ce-9cfe6cbda8a9">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_900599c7-8b7a-485f-ad32-0636f4956054">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_73c7bacd-66a3-4290-aef2-af4355a7bbd4">MC</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_09d550a4-8a79-4c7a-a257-2e42b5ee4d86">Shall be present if (0018,1164) or (0028,0030) is in the Image Instance</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_35125a2e-5e40-46b0-8693-4960f500fd7b">UNITS = EV (um, UCUM, "micrometer")</para>
                        <para xml:id="para_3807aa39-1e7e-4243-8bc1-18d7a0f81c72">UNITS = EV (mm, UCUM, "millimeter")</para>
                     </td>
                  </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
               </tbody>
            </table>
            <para xml:id="para_19dbc575-0bd5-474b-951c-dd7f7d55b7cb">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_a6d8d3f5-538f-4255-8c92-b0bb1f8ec56b">Horizontal Imager Pixel Spacing</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para xml:id="para_393f2b69-ca68-4d52-8611-75289898e693">The <emphasis role="bold"><emphasis role="strikethrough">row (first) </emphasis><emphasis role="underline">second</emphasis></emphasis> component of Imager Pixel Spacing (0018,1164) in the Image IOD. See <xref linkend="sect_C.8.11.4" xrefstyle="select: docname label"/>.</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_502f7856-d4c9-48cc-8b2e-d32d7e3dea58">Vertical Imager Pixel Spacing</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_1af6ebef-548f-4f37-8fe6-7d46d0acb206">The <emphasis role="bold"><emphasis role="strikethrough">column (second) </emphasis><emphasis role="underline">first</emphasis></emphasis> component of Imager Pixel Spacing (0018,1164) in the Image IOD. See <xref linkend="sect_C.8.11.4" xrefstyle="select: docname label"/>.</para>
                     </td>
                  </tr>
               </tbody>
            </informaltable>
         </section>

         <section label="TID 4122" status="3" xml:id="sect_TID_4122">
            <title>CAD Common Image Properties Entry</title>
            <para xml:id="para_e8da5776-f655-471c-912d-aa570efe77c0">...</para>
            <table frame="box" label="TID 4122" rules="all" xml:id="table_TID_4122">
               <caption>CAD Common Image Properties Entry</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_95768e41-2a08-4619-8fc0-2acf9efe05fc"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6a7e5e83-0c49-4148-96a8-ab2b391dde5c">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_efaa76a7-27f6-41b9-b895-b6f775fd6179">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_84b17600-a10f-4daa-8bea-426478309bf3">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_b31a2a6b-ab86-44c8-98fa-21a8afac5bd0">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3a187983-73b2-4320-9d0f-27703257b900">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_46252374-5506-4684-affd-a672551136d5">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4ee2f415-063a-4a98-b981-8410cd4416bc">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81b9e267-ce82-44fc-968f-e7d4e729a4fa">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_af1f9bb5-e86f-450f-9fce-c3faa6deb2e8">7</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8cbe2a34-296c-4527-b469-a3269a983bc0">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_bbec239e-b44d-4a10-8c3e-b6ea9479cb67">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_042b4e7f-db5d-4dc1-8016-88118a96784e">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8812cf63-798c-4317-a1a8-d9e83d6fc894">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_54b5637a-9a5c-4f63-9116-f1e5c9d36fbb">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fc845679-17c9-4fd2-a9da-fdce27846eb4">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_fe22052b-0a5d-447d-a70d-ee73ec21f1e2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_eb0ccaaa-a13a-48c4-8520-1be9f76c223b">Shall be taken from value <emphasis role="bold"><emphasis role="strikethrough">1</emphasis><emphasis role="underline">2</emphasis></emphasis> of Pixel Spacing (0028,0030) in the Image Instances.</para>
                        <para xml:id="para_b1a18c72-84fc-4059-9f96-6c897057fa8f">UNITS = EV (mm/{pixel}, UCUM, "millimeters per pixel")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_94ef2e68-1d03-4423-a31c-372c7354c681">8</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ceae6ac0-d7e3-413e-9223-b6e9ed11c189">&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_a0ee5835-cf76-4e45-a2ca-fa1cbdf8ce25">CONTAINS</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_873a3940-127a-4da0-9430-bf639c524cde">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_6c32dd6d-9a27-4f42-8290-6f6c433e23b8">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(111066, DCM, "Vertical Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e084a03a-4d00-4a5f-a139-92b805f06644">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0980778c-d0de-4f46-91f3-ae2f0bd9edb7">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_9a77d5f7-2116-4c79-9436-95e2dc3fadd2"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3e5e5791-1ff0-4a05-9aae-fd6fdb6f2b9d">Shall be taken from value <emphasis role="bold"><emphasis role="strikethrough">2</emphasis><emphasis role="underline">1</emphasis></emphasis> of Pixel Spacing (0028,0030) in the Image Instances.</para>
                        <para xml:id="para_d8be2a31-97ce-4a71-acb6-b2fc8506270d">UNITS = EV (mm/{pixel}, UCUM, "millimeters per pixel")</para>
                     </td>
                  </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
               </tbody>
            </table>
         </section>

         <section label="TID 7000" status="3" xml:id="sect_TID_7000">
            <title>Implantation Plan</title>
            <para xml:id="para_00e85526-026c-4c9e-91b2-0f8c435e5d78">...</para>
            <table frame="box" label="TID 7000" rules="all" xml:id="table_TID_7000">
               <caption>Implantation Plan</caption>
               <thead>
                  <tr valign="top">
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_002ee634-d39e-431d-86ab-6a7c478c71d5"/>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_27b0f30b-98f0-4bb5-9eb9-be95204fb7e7">NL</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_2cb4854a-5b97-4b27-a219-dae9cc44ba7c">Rel with Parent</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_496c65b6-9d13-4e5d-be35-a4c57fbc9190">VT</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_91a67008-8908-4caa-8920-fea5f8bb115c">Concept Name</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6c109753-94ff-4afa-935f-dbec8f170e96">VM</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_40fe4627-6cdc-487d-b7e6-289657f408d6">Req Type</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_3b92015a-6d47-4ef8-998b-e1379d2f1d95">Condition</para>
                     </th>
                     <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_7a1d8aa9-0049-4170-815b-6775f31846d6">Value Set Constraint</para>
                     </th>
                  </tr>
               </thead>
               <tbody>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="center" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8e468ef1-e893-42a9-96f7-4f48054319da">31</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_816949bd-bf1f-4267-9b00-4ce335732f98">&gt;&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3b57f896-f095-4b23-bcf5-dd030c99b120">HAS PROPERTIES</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_15c69c63-7753-485d-954f-805d15e13d5d">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_3bd6c39d-df84-4430-8bed-bc076fc3b05a">EV <link linkend="DCM_111026" xrefstyle="select: nopage">(111026, DCM, "Horizontal Pixel Spacing")</link>
                        </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_cfde00ab-5040-44b4-956f-a8e475b10cd7">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e4c67973-9f75-4abb-bfe7-177349e94369">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_0fbf3ac6-edaa-43ed-b6f5-fc234fb0a831"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8747dcc2-ac81-495c-8281-a70a58e1af6d">UNITS = EV (mm/{pixel}, UCUM, "mm/pixel")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_ad99e668-d43d-43d6-9e48-0e2d0c671cec">32</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_7e6196d7-e420-4dbc-a10f-7d6837e53fa0">&gt;&gt;&gt;</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e3cf8cda-8812-4680-9990-fa90a01cdc23">HAS PROPERTIES</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5e2f41c5-8340-44b5-8904-161e043eac94">NUM</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                       <para xml:id="para_bfbb8208-bee0-4723-aaf1-65c07c098bb3">EV <link linkend="DCM_111066" xrefstyle="select: nopage">(<emphasis role="bold"><emphasis role="strikethrough">111026</emphasis><emphasis role="underline">111066</emphasis></emphasis>, DCM, "Vertical Pixel Spacing")</link>
              </para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_936443ca-5340-4316-a506-f2f7ff8babdc">1</para>
                     </td>
                     <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_4e254522-1e3c-403d-ae96-48399522cd44">M</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_e5973093-d063-4b04-a551-7b517f1a23a9"/>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_058c2e9e-f918-4e26-a887-52c9474a20a7">UNITS = EV (mm/{pixel}, UCUM, "mm/pixel")</para>
                     </td>
                  </tr>
                  <tr valign="top">
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="center" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="center" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                         <td align="left" colspan="1" rowspan="1">
                           <para>...</para>
                         </td>
                       </tr>
               </tbody>
            </table>
            <para xml:id="para_201eb9f2-1722-4e7e-a27f-6605c1dfbd05">
               <emphasis role="bold">Content Item Descriptions</emphasis>
            </para>
            <informaltable frame="box" rules="all">
               <tbody>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para>...</para>
                     </td>
                  </tr>
                 <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_c4212a86-b63e-4b53-82b1-67d84b582b4b">Row 31</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_8b6b390e-c9c8-4257-8157-1f44adfdb84e">Defines the calibrated Horizontal Pixel Spacing that was used by the planning application, which may be different from the spacing encoded in the referenced Image SOP Instance.</para>
                     </td>
                  </tr>
                  <tr valign="top">
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_dfd4dfa6-2ac7-4f69-95dc-752c491a7666">Row 32</para>
                     </td>
                     <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_5583533e-9854-4f17-b380-ac79b7d4bce1">Defines the calibrated Vertical Pixel Spacing that was used by the planning application, which may be different from the spacing encoded in the referenced Image SOP Instance.</para>
                     </td>
                  </tr>
                 <tr valign="top">
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                   <td align="left" colspan="1" rowspan="1">
                     <para>...</para>
                   </td>
                 </tr>
               </tbody>
            </informaltable>
         </section>

    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td><para><emphasis role="italic">For reference DICOM PS 3.3 pixel spacing description:</emphasis></para></td>
        </tr>
      </informaltable>
    </section>

    <section label="10.7" status="2" xml:id="sect_10.7">
      <title>Basic Pixel Spacing Calibration Macro</title>
      <para xml:id="para_df145af5-fe8b-4896-9b9c-04d3770b6cda">
        <xref linkend="table_10-10" xrefstyle="select: label"/> defines the Attributes for the Basic Pixel Spacing Calibration Macro.</para>
      <table frame="box" label="10-10" rules="all" xml:id="table_10-10">
        <caption>Basic Pixel Spacing Calibration Macro Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_9d4d43cd-3a3d-4413-be30-8057451b2b22">Attribute Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_5da1cce5-5412-441b-b20e-81f18165b8f7">Tag</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_aa8c1498-eecd-4bb7-9a51-e482306eab39">Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_01a7f228-fb28-46f1-a4ce-68a504e96c59">Attribute Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_b947024a-7536-4a84-b6aa-38964dba6fc6">Pixel Spacing</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_814ece40-af51-4c27-9bc5-6f1e880f3fc5">(0028,0030)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_eaf107b1-1133-4720-9fd2-46c25e4eec91">1C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_11e7b6a7-a59c-4d71-a077-6f17a73f5e0c">Physical distance in the patient between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.1" xrefstyle="select: label"/> and <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/>. Required if the image has been calibrated. May be present otherwise.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_56ddef83-22f5-48c2-8959-c71b2938f0a0">...</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_90257137-cbba-4c07-b3a8-62079f9c58fc">...</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_f839c4fb-0401-4bb7-a5e0-c006236bc389">...</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_c5cba6e3-2362-45f1-8004-a3abc577de36">...</para>
            </td>
          </tr>
        </tbody>
      </table>
      <section label="10.7.1" status="3" xml:id="sect_10.7.1">
        <title>Basic Pixel Spacing Calibration Macro Attribute Descriptions</title>
        <section label="10.7.1.1" status="4" xml:id="sect_10.7.1.1">
          <title>Pixel Spacing</title>
          <para xml:id="para_c7ccd9b5-3017-4e02-b37d-c9fe231a750b">Pixel Spacing (0028,0030) specifies the physical distance in the patient between the center of each pixel.</para>
          <para>...</para>
        </section>
         <section label="10.7.1.3" status="4" xml:id="sect_10.7.1.3">
          <title>Pixel Spacing Value Order and Valid Values</title>
          <para xml:id="para_c345f55d-bd7f-416f-8516-e8a0573401c6">All pixel spacing related attributes are encoded as the physical distance between the centers of each two-dimensional pixel, specified by two numeric values.</para>
          <para xml:id="para_44e25525-1c18-4d9b-b943-8cffd61b5a81">The first value is the row spacing in mm, that is the spacing between the centers of adjacent rows, or vertical spacing.</para>
          <para xml:id="para_bc953a63-0f07-4de3-a1cd-4a891857b532">The second value is the column spacing in mm, that is the spacing between the centers of adjacent columns, or horizontal spacing.</para>
          <para xml:id="para_c1452803-b152-4364-8bcf-537a1de6e902">To illustrate, consider the example shown in <xref linkend="figure_10.7.1.3-1" xrefstyle="select:label"/>.</para>
          <para xml:id="para_0bb4fbcf-3f61-4fdc-8592-c9909f5c2b47">
            <figure label="10.7.1.3-1" pgwide="1" xml:id="figure_10.7.1.3-1">
              <title>Example of Pixel Spacing Value Order</title>
              <mediaobject>
                <imageobject>
                  <imagedata fileref="cp1526/PS3.3_10.7.1.3-1.svg"/>
                </imageobject>
              </mediaobject>
            </figure>
          </para>
          <para xml:id="para_d74bb552-688d-4217-8cd1-0be6d4f786d4">Pixel Spacing = Row Spacing \ Column Spacing = 0.30\0.25.</para>
          <para xml:id="para_225daf71-5020-4ad7-a932-6b5768b6d612">All pixel spacing related attributes shall have positive non-zero values, except when there is only a single row or column or pixel of data present, in which case the corresponding value may be zero.</para>
          <note>
            <para xml:id="para_ded0fff9-ddeb-4a99-b3b1-96a513d789c9">A single row or column or "pixel" may occur in MR Spectroscopy instances.</para>
          </note>
          <para xml:id="para_9f54f6a0-1ed8-4dfe-9769-61007a0fca72">This description applies to:</para>
          <itemizedlist>
            <listitem>
              <para xml:id="para_73f7379b-5ca0-4e4f-a77e-ab3e12cd1fd4">Pixel Spacing (0028,0030)</para>
            </listitem>
            <listitem>
              <para xml:id="para_94020fa3-76f0-43ea-91f7-56ad2abf7363">Imager Pixel Spacing (0018,1164)</para>
            </listitem>
            <listitem>
              <para xml:id="para_a23ed486-77f1-4fcd-b387-eb2ba6c8fe5b">Nominal Scanned Pixel Spacing (0018,2010)</para>
            </listitem>
            <listitem>
              <para xml:id="para_179c1b1c-bddd-4ebb-b5ce-4037492ebd93">Image Plane Pixel Spacing (3002,0011)</para>
            </listitem>
            <listitem>
              <para xml:id="para_81356678-c56f-4f0e-846b-561e8609ca9a">Compensator Pixel Spacing (300A,00E9)</para>
            </listitem>
            <listitem>
              <para xml:id="para_c20da2e6-c375-4358-99a1-35d5aa7526fb">Detector Element Spacing (0018,7022)</para>
            </listitem>
            <listitem>
              <para xml:id="para_a80ad226-6ff7-4184-96dd-cb4c34e46ee5">Presentation Pixel Spacing (0070,0101)</para>
            </listitem>
            <listitem>
              <para xml:id="para_a4a33702-9082-4c81-b45d-07d8f5629771">Printer Pixel Spacing (2010,0376)</para>
            </listitem>
            <listitem>
              <para xml:id="para_16b7a1aa-39e0-42c0-b95d-10860b2ae362">Object Pixel Spacing in Center of Beam (0018,9404)</para>
            </listitem>
          </itemizedlist>
        </section>
      </section>
    </section>
    
        <section label="C.7.6.2" status="4" xml:id="sect_C.7.6.2">
          <title>Image Plane Module</title>
          <para xml:id="para_81876b9d-5726-4ab4-8b99-5c66f4d63024">...</para>
          <table frame="box" label="C.7-10" rules="all" xml:id="table_C.7-10">
            <caption>Image Plane Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_4cb4e252-7aae-402b-9ce5-4b48608aa146">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_ef5a5a9a-c545-44ea-95c5-85d0959fcf6b">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_baf8cfc4-de88-4f88-9243-d560be4bba91">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a62c9195-44e6-45a8-9e82-7679caf887f8">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_09be5138-c425-4b3a-b186-4deffbb7cb52">Pixel Spacing</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5a4b15f5-db2c-47f7-8bf5-4dfeee0ac322">(0028,0030)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_dd12f3eb-e241-4f80-a323-4048687813c0">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0990d168-0f15-4a44-8425-628117447661">Physical distance in the patient between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_5c1047cf-bfee-45ae-ac55-25d4fda02a33">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_a4038941-73c1-48fe-bdce-a76546089564">...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c0116d7d-f83a-4d4c-bb80-72a009b45edb">...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_c3827cd7-5ffc-4532-a3fd-ded943f68397">...</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>



        <section label="C.8.11.4" status="4" xml:id="sect_C.8.11.4">
          <title>DX Detector Module</title>
          <para xml:id="para_9719a381-2b89-400f-8cd1-ed1d8c1e61b1">
<xref linkend="table_C.8-71" xrefstyle="select: label"/> contains IOD Attributes that describe a DX detector.</para>
          <table frame="box" label="C.8-71" rules="all" xml:id="table_C.8-71">
            <caption>DX Detector Module Attributes</caption>
            <thead>
              <tr valign="top">
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_28e4a09b-7c87-4fe1-bf5e-9ac198645897">Attribute Name</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_f99b2205-ab86-43e2-afe9-26422648d90f">Tag</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_585d2c4a-43b2-4897-89bb-76237d63af9b">Type</para>
                </th>
                <th align="center" colspan="1" rowspan="1">
                  <para xml:id="para_29499bef-04d3-45cf-8e5c-159fcc48f88f">Attribute Description</para>
                </th>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_437bec56-745b-4ec1-a5d5-5a4397317b29">Imager Pixel Spacing</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_5df3c486-7a66-49f2-aa52-62a4b49ae378">(0018,1164)</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para xml:id="para_c0fd9257-1f36-4c68-b396-84587c856bef">1</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para xml:id="para_0d0b6ad1-6caa-4dad-93c2-bd44df89919b">Physical distance measured at the front plane of the detector housing between the center of each image pixel specified by a numeric pair - row spacing value(delimiter) column spacing value in mm. See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation of the value order.</para>
                  <para xml:id="para_d3970120-a247-42aa-b750-bb164268f349">The value of this attribute shall never be adjusted to account for correction for the effect of geometric magnification or calibration against an object of known size; Pixel Spacing (0028,0030) is specified for that purpose.</para>
                </td>
              </tr>
              <tr valign="top">
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="center" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
                <td align="left" colspan="1" rowspan="1">
                  <para>...</para>
                </td>
              </tr>
            </tbody>
          </table>
        </section>

    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td><para><emphasis role="italic">For reference DICOM PS3.16 concept definitions:</emphasis></para></td>
        </tr>
      </informaltable>
    </section>
    
    <section>
      <title/>
      <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
      <caption>DICOM Controlled Terminology Definitions</caption>
      <thead>
        <tr valign="top">
          <th align="center" colspan="1" rowspan="1">
            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">
              <emphasis role="bold">Code Value</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">
              <emphasis role="bold">Code Meaning</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">
              <emphasis role="bold">Definition</emphasis>
            </para>
          </th>
          <th align="center" colspan="1" rowspan="1">
            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">
              <emphasis role="bold">Notes</emphasis>
            </para>
          </th>
        </tr>
      </thead>
      <tbody>
        
    <tr valign="top">
      <td align="center" colspan="1" rowspan="1">
        <para xml:id="DCM_111026">111026</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_b64ae20f-fc2a-4cf1-90e1-9a81440f81a0">Horizontal Pixel Spacing</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_250c65d9-1035-4855-8e5a-044e37701a8d">For projection radiography, the horizontal physical distance measured at the front plane of an Image Receptor housing between the center of each pixel<emphasis role="bold"><emphasis role="underline"> (spacing between the centers of adjacent columns)</emphasis></emphasis>. For tomographic images, the horizontal physical distance in the patient between the center of each pixel.</para>
      </td>
      <td align="left" colspan="1" rowspan="1">
        <para xml:id="para_49f6e571-7031-43d0-a033-4c6f6966ea0d"/>
      </td>
    </tr>
        <tr valign="top">
          <td align="center" colspan="1" rowspan="1">
            <para xml:id="DCM_111066">111066</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para xml:id="para_b1a84523-137f-4db5-a5c2-877a786445e0">Vertical Pixel Spacing</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para xml:id="para_a481db7b-70bc-42ad-aa27-03a7e9908931">For projection radiography, the vertical physical distance measured at the front plane of an Image Receptor housing between the center of each pixel<emphasis role="bold"><emphasis role="underline"> (spacing between the centers of adjacent rows)</emphasis></emphasis>. For tomographic images, the vertical physical distance in the patient between the center of each pixel.</para>
          </td>
          <td align="left" colspan="1" rowspan="1">
            <para xml:id="para_1237eaf7-43ff-472e-85bd-647af8bbecc2"/>
          </td>
        </tr>
      </tbody>
    </table>
    </section>
    
  </chapter>
</book>