<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1464</title>
  <subtitle>Add reference region segmentation property type</subtitle>
  <chapter>
    <title/>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Status</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Final Text</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Date of Last Update</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2015/11/10</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Person Assigned</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>David Clunie</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
            xlink:href="mailto:dclunie@dclunie.com"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submitter Name</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Andriy Fedorov</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
            xlink:href="mailto:fedorov@bwh.harvard.edu"/></para></td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submission Date</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2015/02/10</para>
        </td>
      </tr>
    </informaltable>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Correction Number CP-1464</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Log Summary: Add reference region segmentation property type</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Name of Standard</para>
          <para>PS3.16 2015c</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
          <para>There is no standard code specified for reference regions (e.g., to identify the background ROI for tumor to background ratio). Add one.</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
      </tr>
    </informaltable>
  </chapter>
  <chapter>
    <title/>


    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
    </section>

    <section label="CID 7165" status="3" xml:id="sect_CID_7165">
      <title>Abstract Segmentation Types</title>
      <variablelist spacing="compact">
        <varlistentry>
          <term>
            <emphasis role="bold">Type:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold">Extensible</emphasis>
            </para>
          </listitem>
        </varlistentry>
        <varlistentry>
          <term>
            <emphasis role="bold">Version:</emphasis>
          </term>
          <listitem>
            <para>
              <emphasis role="bold"><emphasis role="strikethrough">20140627</emphasis><emphasis role="underline">20151113</emphasis></emphasis>
            </para>
          </listitem>
        </varlistentry>
      </variablelist>
      <table rules="all" frame="box" label="CID 7165" xml:id="table_CID_7165">
        <caption>Abstract Segmentation Types</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Coding Scheme Designator</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Value</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">Code Meaning</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">SNOMED-CT Concept ID</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold">UMLS Concept Unique ID</emphasis>
              </para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_125040" xrefstyle="select: nopage">125040</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Background</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>T-D0050</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Tissue</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>85756007</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0040300</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>SRT</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>F-61779</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Waste Material</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>289925000</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>C0043045</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para>DCM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <link linkend="DCM_125041" xrefstyle="select: nopage">125041</link>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para>Registration Input</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">NCIt</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>
                <emphasis role="bold"><emphasis role="underline"><link xl:href="https://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C94970" xl:show="new">C94970</link></emphasis></emphasis>
              </para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Reference Region</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">C2986814</emphasis></emphasis></para>
            </td>
          </tr>
        </tbody>
      </table>
    </section>
    

    
  </chapter>
</book>
