  <title>CP-1458</title>
  <subtitle>Value representation of real world value first and last values mapped</subtitle>
  <chapter>
    <title/>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Status</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Final Text</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Date of Last Update</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2015/09/16 (corrected 2015/10/16)</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Person Assigned</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>David Clunie</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
            xlink:href="mailto:dclunie@dclunie.com"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submitter Name</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>Michael Onken</para>
          <para><link xmlns:xlink="http://www.w3.org/1999/xlink"
            xlink:href="mailto:onken@open-connections.de"/></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Submission Date</para>
        </td>
        <td rowspan="1" colspan="1" valign="top">
          <para>2015/01/15</para>
        </td>
      </tr>
    </informaltable>
    <informaltable rules="all" frame="box">
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Correction Number CP-1458</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Log Summary: Value representation of real world value first and last values mapped</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">
          <para>Name of Standard</para>
          <para>PS3.3, PS3.6</para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
          <para>The VR for the real world value mapping input values may be US or SS depending on the value of Pixel Representation, but this is not explicitly specified.</para>
          <para>Floating point values for the range of input values are added for use when an integer range is not sufficient (without invalidating the installed base that uses the existing attributes when they are sufficient).</para>
          <para>The use of the equation rather than lookup table method is required when floating point stored pixel values are used (since the meaning of looking up floating point values that lie between integer indices into a lookup table is not defined).</para>
          <para><emphasis role="italic">[Ed.Note: PS3.3 changes corrected on 2015/10/16 to make data element tags used consistent with PS3.6; first and last were swapped in text of 2015/09/16.]</emphasis></para>
        </td>
      </tr>
      <tr>
        <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
      </tr>
    </informaltable>
  </chapter>
  <chapter>
    <title/>
    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
    </section>
    
    <section label="C.7.6.16.2.11" status="6" xml:id="sect_C.7.6.16.2.11">
      <title>Real World Value Mapping Macro</title>
      <para>...</para>
      <table frame="box" label="C.7.6.16-12b" rules="all" xml:id="table_C.7.6.16-12b">
        <caption>Real World Value Mapping Item Macro Attributes</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_6e8e4f6c-2271-4a9a-974d-8b42545b1b34">Attribute Name</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_1f2022d8-22bb-4217-a733-78b3e68577a9">Tag</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_72a0e165-d196-4752-a3cf-57f98ff1b0c5">Type</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_052368dc-5b23-4e0c-a131-21746d308b90">Attribute Description</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_ad0d1a49-e303-45eb-9d28-81b70503956e">Real World Value First Value Mapped</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_f71ca554-4e7b-4658-a2ed-b218f1e82d80">(0040,9216)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_1d3c2687-a538-4b8b-bd43-fcbe45fa1fc2">1<emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_00a9868b-af1e-406c-b51c-6a6c0064b4ab">Specifies the first stored value mapped for the Real Word Value Intercept (0040,9224) and Real World Value Slope (0040,9225) or Real World Value LUT (0040,9212) of this Item.</para>
              <para><emphasis role="bold"><emphasis role="underline">Required if Pixel Data (7FE0,0010) or Real World Value LUT Data (0040,9212) is present or Double Float Real World Value First Value Mapped (0040,9214) is absent.</emphasis></emphasis></para>
              <note>
                <para><emphasis role="bold"><emphasis role="underline">This Attribute may be used even when Float Pixel Data (7FE0,0008) or Double Float Pixel Data ((7FE0,0009) are used instead of Pixel Data (7FE0,0010) if an integer of the size of this Attribute is sufficient to define the range.</emphasis></emphasis></para>
              </note>
              <para xml:id="para_6b299930-57eb-493b-894e-f26a8992c916">See <xref linkend="sect_C.7.6.16.2.11.1" xrefstyle="select: label"/> for further explanation.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_d95d4032-2c83-4f3b-bc49-9b9966c0a0fc">Real World Value Last Value Mapped</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_76e97a85-1486-4646-9914-2cf551a55c97">(0040,9211)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_a75d9f5c-ae48-4350-8f8f-fc459be3cfbc">1<emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_f3b7d3a6-b9af-433e-8f6d-af6742469564">Specifies the last stored value mapped for the Real Word Value Intercept (0040,9224) and Real World Value Slope (0040,9225) or Real World Value LUT (0040,9212) of this Item.</para>
              <para><emphasis role="bold"><emphasis role="underline">Required if Pixel Data (7FE0,0010) or Real World Value LUT Data (0040,9212) is present or Double Float Real World Value Last Value Mapped (0040,9213) is absent.</emphasis></emphasis></para>
              <note>
                <para><emphasis role="bold"><emphasis role="underline">This Attribute may be used even when Float Pixel Data (7FE0,0008) or Double Float Pixel Data ((7FE0,0009) are used instead of Pixel Data (7FE0,0010) if an integer of the size of this Attribute is sufficient to define the range.</emphasis></emphasis></para>
              </note>
              <para xml:id="para_069a1e87-8158-4e4f-8a0d-14909671cffe">See <xref linkend="sect_C.7.6.16.2.11.1" xrefstyle="select: label"/> for further explanation.</para>
            </td>
          </tr>
          
          
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Double Float Real World Value First Value Mapped</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">(0040,9214)</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">1C</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Specifies the first stored value mapped for the Real Word Value Intercept (0040,9224) and Real World Value Slope (0040,9225) of this Item.</emphasis></emphasis></para>
              <para><emphasis role="bold"><emphasis role="underline">Required if Real World Value First Value Mapped (0040,9216) is absent.</emphasis></emphasis></para>
              <note>
                <para><emphasis role="bold"><emphasis role="underline">The same Attribute with a double float precision value is used whether or not Float Pixel Data (7FE0,0008) or Double Float Pixel Data ((7FE0,0009) are present, an integer value is not sufficient.</emphasis></emphasis></para>
              </note>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Double Float Real World Value Last Value Mapped</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">(0040,9213)</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">1C</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Specifies the last stored value mapped for the Real Word Value Intercept (0040,9224) and Real World Value Slope (0040,9225) of this Item.</emphasis></emphasis></para>
              <para><emphasis role="bold"><emphasis role="underline">Required if Real World Value Last Value Mapped (0040,9211) is absent.</emphasis></emphasis></para>
              <note>
                <para><emphasis role="bold"><emphasis role="underline">The same Attribute with a double float precision value is used whether or not Float Pixel Data (7FE0,0008) or Double Float Pixel Data ((7FE0,0009) are present, an integer value is not sufficient.</emphasis></emphasis></para>
              </note>
            </td>
          </tr>
          
          
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7da11c72-bd3f-4629-aaca-abd7052d0cd6">Real World Value Intercept</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_054d1ff2-a5ea-4f53-9167-98e492791a31">(0040,9224)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_99923d3e-776d-4094-8f5b-f755ac6c9e2e">1C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_7e2447e1-c9d4-4067-ab11-fd93e0b21bd0">The Intercept value in relationship between stored values (SV) and the Real World values.</para>
              <para xml:id="para_65a897db-6fd5-415a-9870-2c92ef2928b9">See <xref linkend="sect_C.7.6.16.2.11.1.2" xrefstyle="select: label"/> for further explanation.</para>
              <para xml:id="para_898b3692-bef0-4374-afda-a95d27dfa247">Required if <emphasis role="bold"><emphasis role="underline">Float Pixel Data (7FE0,0008) or Double Float Pixel Data ((7FE0,0009) are present or </emphasis></emphasis>Real World Value LUT Data (0040,9212) is not present.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5ae3ae1c-2105-4776-b05a-837b6681f121">Real World Value Slope</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_eb61b0dd-9150-4f90-a8d0-84fe0448ca67">(0040,9225)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_dfcf2c35-ee6e-408e-8e25-76de28f4c940">1C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_5a44baa8-beaa-406a-ab55-b28ffb2aebdf">The Slope value in relationship between stored values (SV) and the real world values.</para>
              <para xml:id="para_47a07031-58fb-4df1-893c-44ecaf126606">See <xref linkend="sect_C.7.6.16.2.11.1.2" xrefstyle="select: label"/> for further explanation.</para>
              <para xml:id="para_f9a1f00c-7316-4f90-bd07-1cfa235601c1">Required if <emphasis role="bold"><emphasis role="underline">Float Pixel Data (7FE0,0008) or Double Float Pixel Data ((7FE0,0009) are present or </emphasis></emphasis>Real World Value LUT Data (0040,9212) is not present.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_1c5bb746-1443-452c-8892-281a0da3dd10">Real World Value LUT Data</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_dc7cef7c-1065-4b8c-a3d0-2a61b3239035">(0040,9212)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_9fccad10-7e8f-4a94-9e50-b6615ffca426">1C</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_4d056908-0d5d-4b35-962d-e44d084a96b3">LUT Data in this Sequence.</para>
              <para xml:id="para_456175d2-ea27-4933-bf98-2ed39f0672cb">Required if Real World Value Intercept (0040,9224) is not present.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_22d9588c-721e-407c-8d62-9f64ed1361f7">LUT Explanation</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_cb6acafa-ab80-4280-92f3-df2d28dd2b8a">(0028,3003)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_2003a835-55ac-42fa-84f8-cd84ee3ce4b0">1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_6a7c5448-ef80-4f7b-bf88-7dacb6b98cb6">Free form text explanation of the meaning of the transformation in this Item.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_dbbe3f18-5452-4826-aebc-5604798969c8">LUT Label</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_77e79797-3365-41ba-b338-616da45eb62d">(0040,9210)</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para xml:id="para_362c5559-002e-4f9a-b8cb-82760593e394">1</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_68de3918-f0d3-414d-b8f9-d94c91a041d1">Label that is used to identify the transformation of this Item.</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para xml:id="para_175d0c33-fd9b-4a9b-8db1-fec20d966ce6">...</para>
            </td>
            <td align="center" colspan="1" rowspan="1">...</td>
            <td align="center" colspan="1" rowspan="1">...</td>
            <td align="left" colspan="1" rowspan="1">...</td>
          </tr>
        </tbody>
      </table>
      <section label="C.7.6.16.2.11.1" status="7" xml:id="sect_C.7.6.16.2.11.1">
        <title>Real World Value Representation</title>
        <para>...</para>
        <section label="C.7.6.16.2.11.1.2" status="8" xml:id="sect_C.7.6.16.2.11.1.2">
          <title>Real World Values Mapping Sequence Attributes</title>
          <para>The Real World Value First Value Mapped (0040,9216) and Real World Value Last Value
            Mapped (0040,9211) Attributes describe the range of stored pixel values that are mapped by
            the Sequence Item. Stored pixel values less than the first value mapped, or greater than the
            last value mapped have no real value attached.</para>
          <para>When the Real World Value Intercept (0040,9224) and Real World Value Slope (0040,9225)
            attributes are supplied, the stored value (SV) is converted to a real world value (RV) using
            the equation:</para>
          <para>RV = (Real World Value Slope) * SV + Real World Value Intercept</para>
          <para>When the Real World Value LUT Data (0040,9212) attribute is supplied, Real World Values
            are obtained via a lookup operation. The stored pixel value of the first value mapped is
            mapped to the first entry in the LUT Data. Subsequent stored pixel values are mapped to the
            subsequent entries in the LUT Data up to a stored pixel value equal to the last value
            mapped.</para>
          <para>The number of entries in the LUT data is given by:</para>
          <para>Number of entries = Real World Value Last Value Mapped- Real World Value First Value
            Mapped + 1</para>
          
          <note>
            <para><emphasis role="bold"><emphasis role="underline">If the stored pixel values that are encoded as floating point rather than integer values, only the equation and not the lookup operation is defined.</emphasis></emphasis></para>
          </note>
          <para><emphasis role="bold"><emphasis role="underline">The Value Representation of Real World Value First Value Mapped (0040,9216) and Real World Value Last Value Mapped (0040,9211) (US or SS) is determined by the value of Pixel Representation (0028,0103) in the case of integer pixel data, or is SS in the case of floating point pixel data if these Attributes are present.</emphasis></emphasis></para>
          <note>
            <para><emphasis role="bold"><emphasis role="underline">In practice, integer values may well be sufficient to define an input range that exceeds the actual stored floating point pixel value range. The reason to permit floating point alternatives to an integer range is that sometimnes the stored floating point values may be very large and exceed what can be specified as an integer value.</emphasis></emphasis></para>
          </note>
        </section>
      </section>
    </section>
    
    
    <section>
      <title/>
      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Add new attributes to DICOM PS3.6 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
    </section>
    
    <section label="6" status="1" xml:id="chapter_6">
      <title>Registry of DICOM Data Elements</title>
      
      <table frame="box" label="6-1" rules="all" xml:id="table_6-1">
        <caption>Registry of DICOM Data Elements</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_3e8c52d5-3582-4ec4-a7e6-acd7604caf32">
                <emphasis role="bold">Tag</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_ac298c3b-bcdd-462b-9240-c38e738bfb7c">
                <emphasis role="bold">Name</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_99f6b0ff-e1b0-484e-83b5-c3003d61704c">
                <emphasis role="bold">Keyword</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_42b3621d-8b30-46eb-8992-10bb21310ac7">
                <emphasis role="bold">VR</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_551ea829-a949-4bfd-a201-bb102024e64c">
                <emphasis role="bold">VM</emphasis>
              </para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para xml:id="para_3a18713f-2e81-4664-b9a1-e4e3d41957ab"/>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">(0040,9213)</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Double Float Real World Value Last Value Mapped</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Double​Float​Real​World​Value​Last​Value​Mapped</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="underline"><emphasis role="bold">FD</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
          <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">(0040,9214)</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Double Float Real World Value First Value Mapped</emphasis></emphasis></para>
            </td>
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Double​Float​Real​World​Value​First​Value​Mapped</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">FD</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para/>
            </td>
          </tr>
        </tbody>
      </table>
      
    </section>
    
  </chapter>
</book>