<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
  <title>CP-1409</title>
  <subtitle>Add Conformance Storage Media Categories</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>STATUS</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Final Text</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2015/01/06</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>Jörg Riesmeier</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dicom@jriesmeier.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2014/06/19</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-1409</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Conformance Storage Media Categories</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
        <para>PS3.2 2014c</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Rationale for Correction:</para>
        <para>The Conformance Statement Template in PS3.2 Annex A requires a table of Supported Media Storage Application Profiles, which currently only describes categories of CD, MOD and DVD.</para>
        <para>Extended it to support other media types supported in PS3.11 and PS3.12.</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.2 Table A.1-3 and preceding text as follows:</emphasis></para></td></tr>
      </informaltable>

      <para>A table of Supported Media Storage Application Profiles (with roles) is provided, organized in <emphasis role="bold"><emphasis role="strikethrough">3 </emphasis></emphasis>categories:</para>
      <itemizedlist>
        <listitem>
          <para>Compact Disk - Recordable</para>
        </listitem>
        <listitem>
          <para>Magneto-Optical Disk</para>
        </listitem>
        <listitem>
          <para>DVD</para>
        </listitem>
        <listitem>
          <para><emphasis role="bold"><emphasis role="underline">BD</emphasis></emphasis></para>
        </listitem>
        <listitem>
          <para><emphasis role="bold"><emphasis role="underline">USB and Flash Memory</emphasis></emphasis></para>
        </listitem>
        <listitem>
          <para><emphasis role="bold"><emphasis role="underline">Email</emphasis></emphasis></para>
        </listitem>
        <listitem>
          <para><emphasis role="bold"><emphasis role="underline">Other Media</emphasis></emphasis></para>
        </listitem>
      </itemizedlist>
      <table frame="box" label="A.1-3" rules="all" xml:id="table_A.1-3">
        <caption>Media Services</caption>
        <thead>
          <tr valign="top">
            <th align="center" colspan="1" rowspan="1">
              <para>Media Storage Application Profile</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Write Files (FSC or FSU)</para>
            </th>
            <th align="center" colspan="1" rowspan="1">
              <para>Read Files (FSR)</para>
            </th>
          </tr>
        </thead>
        <tbody>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold">Compact Disk - Recordable</emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>General Purpose CD-R</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>Option</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>Yes</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold">Magneto-Optical Disk</emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>CT/MR 2.3 GB MOD</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>Yes</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>Yes</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold">DVD</emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para>General Purpose DVD-RAM</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>Yes</para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para>Yes</para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">BD</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">General Purpose BD Interchange with MPEG-4 AVC/H.264 BD-Compatible HiP@Level4.1</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Yes</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Yes</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">USB and Flash Memory</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">General Purpose USB Media Interchange with JPEG</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Yes</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Yes</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Email</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1"/>
            <td align="center" colspan="1" rowspan="1"/>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">General Purpose MIME Interchange</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Yes</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">No</emphasis></emphasis></para>
            </td>
          </tr>
          <tr valign="top">
            <td align="left" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">General Purpose ZIP Email</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">Yes</emphasis></emphasis></para>
            </td>
            <td align="center" colspan="1" rowspan="1">
              <para><emphasis role="bold"><emphasis role="underline">No</emphasis></emphasis></para>
            </td>
          </tr>
        </tbody>
      </table>
      
    </section>
  </chapter>
</book>