<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2489</title>
    <subtitle>Add anatomic concepts for middle and inner ear</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/21</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/09</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2489</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add anatomic concepts for middle and inner ear</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Middle ear structures may be segmented or described in reports but are not included in any DICOM context group. Add them.</para>
                    <para><emphasis role="italic">[Ed.Note. Probably not worth having separate subordinate context group specific to ear structures.</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note. SNOMED CT CRS Request ID#966303.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>        
        
        
        <section label="CID 4028" status="3" xml:id="sect_CID_4028">
            <title>Craniofacial Anatomic Region</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2d194e62-57c1-4155-aa13-78ad2d643788">
                            <emphasis role="bold"><emphasis role="underline">20170914</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 4028" rules="all" xml:id="table_CID_4028">
                <caption>Craniofacial Anatomic Region</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ae672baf-ac9e-4704-8bed-42a3a86a3d68">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e820c83-11cc-4cf2-8a44-0f0917284130">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d01fc17-42cf-4b88-afc2-23275cd71f23">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb9c6a10-6df5-42ab-95f8-2983fbbec438">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e89ceebd-78bb-4e5e-8ef7-2ea4a7d6334b">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/41845008" xl:show="new"><emphasis role="bold"><emphasis role="underline">41845008</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Auditory ossicle</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/41845008" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB400</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0013450" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0013450</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95034209-e5f2-4a0b-a201-c0cc0e83f7f7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_657b2040-0c24-4b5d-b970-6fd7ec78a92c">
                                <link xl:href="http://snomed.info/id/312779009" xl:show="new">312779009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_564b5ae8-6768-4258-aefb-c0e90a6c4a68">Bone structure of head and/or neck</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a46213dc-15bd-4fbd-a692-98c2b9f5afff">
                                <link xl:href="http://snomed.info/id/312779009" xl:show="new">T-D006D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad525c29-99ef-473d-88a6-b7abd0857edb">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0730130" xl:show="new">C0730130</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_374d37e6-af07-4e15-b438-e85fbb99ea5d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0d2f8694-051f-43c6-b635-d7d44b1e1632">
                                <link xl:href="http://snomed.info/id/122494005" xl:show="new">122494005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a9e696ed-472b-4d0a-bede-c50ce665ca7a">Cervical spine</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3c8a7523-43f5-44f9-9d8f-ca422af90fe1">
                                <link xl:href="http://snomed.info/id/122494005" xl:show="new">T-11501</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c042ba5d-44c5-44d7-ad66-9376932ed8fe">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0728985" xl:show="new">C0728985</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/80169004" xl:show="new"><emphasis role="bold"><emphasis role="underline">80169004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Cochlea</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/80169004" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB800</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0009195" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0009195</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38e649e6-23e6-4c88-9d9d-882f6eabb757">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63f379a4-ab4d-4ffc-8154-60fe2a8b7ade">
                                <link xl:href="http://snomed.info/id/52374004" xl:show="new">52374004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_486fe9f7-e7a1-4a75-8574-d23e9320c854">Ethmoid bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d65e6965-2025-460f-b1d6-fc69285092a1">
                                <link xl:href="http://snomed.info/id/52374004" xl:show="new">T-11156</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64e79071-c9cd-49be-bef2-2453f16b036e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0015027" xl:show="new">C0015027</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2d32eb5b-921e-479a-b213-2a276ab57d5d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_38915f85-575b-4f9c-ae95-a42f82a6dab5">
                                <link xl:href="http://snomed.info/id/28347008" xl:show="new">28347008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_eabed95c-41e2-496e-a67f-837ed4b00f9d">External ear</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ff90441-be3b-4f19-8455-ca452212c114">
                                <link xl:href="http://snomed.info/id/28347008" xl:show="new">T-AB100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93ff3769-783f-4507-baf6-e0e34474c8b5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0013453" xl:show="new">C0013453</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5064e9a-7724-4e80-aefe-f142dba898ae">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24451ec7-6a01-4864-969b-3a54c6816815">
                                <link xl:href="http://snomed.info/id/79652003" xl:show="new">79652003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_09970f6f-e5db-40f5-830e-b67cdbfcef39">Eyeball</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_76574622-7196-4bac-a6fa-b4b1b16ef273">
                                <link xl:href="http://snomed.info/id/79652003" xl:show="new">T-AA770</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bb157dd6-4334-4122-94b5-174b13d1952f">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0229242" xl:show="new">C0229242</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_700d39f7-dc0b-4920-8644-c49393624885">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec92eef8-1482-4e5e-a8b0-e8538908ca4a">
                                <link xl:href="http://snomed.info/id/371398005" xl:show="new">371398005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_56a579ac-47ff-4722-adde-e1caf6706577">Eye region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ccd73080-c638-4366-9bc6-ca7627c704a5">
                                <link xl:href="http://snomed.info/id/371398005" xl:show="new">T-D0801</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bbac022a-b55b-493a-912f-5260bb423603">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0015392" xl:show="new">C0015392</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e8b41e5-ffc8-45bb-9cc3-627537243110">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a4641d9-8f64-4c11-9add-9d99b4af899e">
                                <link xl:href="http://snomed.info/id/91397008" xl:show="new">91397008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_215ffedb-a49e-4e3f-91d8-3b84ec79b8f6">Facial bones</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ec46e2b-e7b0-41e1-8c6d-8926cce3127f">
                                <link xl:href="http://snomed.info/id/91397008" xl:show="new">T-11196</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddae8512-f761-4a0c-885a-44aa6c5ef24d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0015455" xl:show="new">C0015455</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc5939ae-bf0d-4f4a-b297-005f6dce63bb">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e7de022-851f-4112-b6c6-767a84c98986">
                                <link xl:href="http://snomed.info/id/74872008" xl:show="new">74872008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dcbc04c4-c979-4c6d-b0e8-439516d99b77">Frontal bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6d353f9-b9b4-41c9-a466-99c741bab7fd">
                                <link xl:href="http://snomed.info/id/74872008" xl:show="new">T-11110</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_032e973a-1cc1-496b-86a1-8fcd546524d5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0016732" xl:show="new">C0016732</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d4a1f7bc-cd18-4856-ab38-0318a434c776">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa78bd3f-6256-49cb-be36-dd7c978eb129">
                                <link xl:href="http://snomed.info/id/69536005" xl:show="new">69536005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_760ef352-fb01-45c2-b2fc-24610be22bd2">Head</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d9c890df-b3ca-4b9f-b4fd-830601630760">
                                <link xl:href="http://snomed.info/id/69536005" xl:show="new">T-D1100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f74b2209-8db2-4022-bc92-718594e09de0">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0018670" xl:show="new">C0018670</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3b0558f4-8925-4e4f-b419-dbd81f2cdb72">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_86aba271-c8c8-4759-968b-f4402bd02ec9">
                                <link xl:href="http://snomed.info/id/774007" xl:show="new">774007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2728cd82-b55a-4661-83fa-d949488b88cf">Head and Neck</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ee2c96c4-a024-4d8c-854b-93530e0e00b3">
                                <link xl:href="http://snomed.info/id/774007" xl:show="new">T-D1000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_31eec499-204f-4332-a3e0-edbd73b404c1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0460004" xl:show="new">C0460004</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21b571a4-0444-4f2c-a4d4-61c5d931120c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80f81dd0-bd5e-49e8-b312-591bd4e2a088">
                                <link xl:href="http://snomed.info/id/21387005" xl:show="new">21387005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9b5bd66b-ad96-456e-b761-5255b9d22fb8">Hyoid bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a16878cd-fc42-49c1-921c-0cf325927dba">
                                <link xl:href="http://snomed.info/id/21387005" xl:show="new">T-11190</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_64a45959-caf7-4971-8268-96045d700d2f">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0020417" xl:show="new">C0020417</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/35395007" xl:show="new"><emphasis role="bold"><emphasis role="underline">35395007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Incus</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/35395007" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB420</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0021181" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0021181</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c12b572d-e57f-4a5e-8b61-f6299a291d7e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f3859c1b-3e0f-4a14-8a77-633f1f5bcab5">
                                <link xl:href="http://snomed.info/id/22945000" xl:show="new">22945000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ce76798e-62e5-4226-bb47-290c9137b266">Inner ear</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bc6b2b58-bd01-4667-82c0-30169c3018d7">
                                <link xl:href="http://snomed.info/id/22945000" xl:show="new">T-AB700</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45f3bc0f-a45b-46a8-b62f-60f64cc57353">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0022889" xl:show="new">C0022889</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7920cbab-f242-4282-9ca3-4fb68c85ea1d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fe24655-6b5b-4b01-bd88-a67134d1fa2a">
                                <link xl:href="http://snomed.info/id/361078006" xl:show="new">361078006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dc90435e-67ab-413a-b1f3-973ca7feecc0">Internal Auditory Canal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f6f5d3d-9cf1-4bee-86be-5ed611d57365">
                                <link xl:href="http://snomed.info/id/361078006" xl:show="new">T-AB959</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2cad874-dbbb-475f-9b7c-68b3af7603b7">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1283773" xl:show="new">C1283773</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_912e29bf-d77b-4e31-aed2-efb9ed71a09f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4e816e9-5c35-4f98-8035-cf8716d79cde">
                                <link xl:href="http://snomed.info/id/661005" xl:show="new">661005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bf961c03-a681-46b7-b474-07bfc58765e1">Jaw region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8dc05d51-75e9-45c1-b0f2-b68894badde4">
                                <link xl:href="http://snomed.info/id/661005" xl:show="new">T-D1213</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_774c650c-ce19-4ae7-8cb5-2a7b7f431816">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0022359" xl:show="new">C0022359</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8af9e77d-fa8a-4a0c-8c4a-85c4e96186c6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c5fb71c-7a8c-40c3-b8bd-c73213533e90">
                                <link xl:href="http://snomed.info/id/6229007" xl:show="new">6229007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_06b1b77d-73bc-4e2c-bef6-5caac3863863">Lacrimal bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a9f90a43-8564-4327-a22c-7c4160a19ccb">
                                <link xl:href="http://snomed.info/id/6229007" xl:show="new">T-1115A</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2dcc4000-0c8d-437d-87fc-461b8a52a692">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222733" xl:show="new">C0222733</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb0c81d6-9dfe-4d71-b541-e3c0a1bae6c1">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f56e30c2-5504-4519-9cb0-ba9a7316b455">
                                <link xl:href="http://snomed.info/id/4596009" xl:show="new">4596009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_59659e33-5b57-4fad-96b6-05c9df2b85ab">Larynx</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6050519-acb9-4b76-89cb-a326e336c43c">
                                <link xl:href="http://snomed.info/id/4596009" xl:show="new">T-24100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8ca618b-4b4f-44c0-a213-00585c0eea70">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0023078" xl:show="new">C0023078</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c1470397-e64e-4e92-9033-f835628f714f">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f9a143c-7d1c-4c4a-873e-a93102c14786">
                                <link xl:href="http://snomed.info/id/48477009" xl:show="new">48477009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3f6094f4-9dc3-4016-b522-3cb7cf26fd3e">Lip</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e716ae7-1023-456c-a421-defee38a81ec">
                                <link xl:href="http://snomed.info/id/48477009" xl:show="new">T-52000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_555ba7fc-9bc2-4348-8fc8-f710d2b2c361">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0023759" xl:show="new">C0023759</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/34080009" xl:show="new"><emphasis role="bold"><emphasis role="underline">34080009</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Malleus</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/34080009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB410</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0024631" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0024631</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0ef7195-28b7-4ad4-b9e3-61993a8a27f7">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1a1af9c6-7045-416a-8d2e-a6dc8604125d">
                                <link xl:href="http://snomed.info/id/91609006" xl:show="new">91609006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7fc371f5-c1ae-4103-8a2d-e6e35130e524">Mandible</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7ba7bb0-5938-46cf-b237-1690584e7f0d">
                                <link xl:href="http://snomed.info/id/91609006" xl:show="new">T-11180</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5ec08b54-4268-48fb-9835-c56f2d7845e3">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0024687" xl:show="new">C0024687</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_75c59a3f-5972-422e-b54f-ebc265fbf6da">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3badc5f-e1dd-4daf-8f33-c78be297e4d6">
                                <link xl:href="http://snomed.info/id/59066005" xl:show="new">59066005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d59c6a45-2ce1-4ae1-8759-45a5c8c3db47">Mastoid bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3ac8bac-6b92-4d87-9966-fe39cf61024f">
                                <link xl:href="http://snomed.info/id/59066005" xl:show="new">T-11133</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_450bbc73-fbef-4058-b5df-10ec0359c6e1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0446908" xl:show="new">C0446908</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c832211c-8a2f-4c10-a14f-5861dc05fd8b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b633f54-4e1d-477f-953a-1909e703f76e">
                                <link xl:href="http://snomed.info/id/70925003" xl:show="new">70925003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_128e96bd-6e4f-4e7d-84dc-33db514db757">Maxilla</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c4dc024-9719-4d27-9eab-69f49bfbecc4">
                                <link xl:href="http://snomed.info/id/70925003" xl:show="new">T-11170</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b5172670-7dfb-4c6e-875e-66630250114f">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0024947" xl:show="new">C0024947</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60714a39-124b-4ddd-988f-82f7656bfe1a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0cec7411-ae1e-4a20-9cd6-d085c56205cf">
                                <link xl:href="http://snomed.info/id/25342003" xl:show="new">25342003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bf668ff2-7bbd-4708-8a50-ef0bf4b17f88">Middle ear</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8e77c98d-f68c-491a-b474-b76fef33ed6b">
                                <link xl:href="http://snomed.info/id/25342003" xl:show="new">T-AB300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a0afda25-93d9-4a64-877e-7fea3c3aac79">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0013455" xl:show="new">C0013455</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6be8cde5-e5e3-434a-8c30-ced43da1a87a">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_addcecb5-be81-4404-bc95-a88a0ebf69d0">
                                <link xl:href="http://snomed.info/id/22688005" xl:show="new">22688005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_83cdea0b-a89b-4751-be7a-d3b72aea22c8">Muscle of head</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16837279-8b40-45e1-b125-014c71ced382">
                                <link xl:href="http://snomed.info/id/22688005" xl:show="new">T-13100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_77ea2f0d-e32f-4b7e-9b97-2cd70c25f008">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0224097" xl:show="new">C0224097</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_023e26dc-2c21-4e3b-967a-89018fc5cc53">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_40cfafa4-206f-4bc4-a70f-eac6788086b7">
                                <link xl:href="http://snomed.info/id/81727001" xl:show="new">81727001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_990aac76-4ed6-405e-bf84-977995d892ec">Muscle of neck</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b3bba7d-b920-4181-b92b-29fc7f371f95">
                                <link xl:href="http://snomed.info/id/81727001" xl:show="new">T-13300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50dabe82-2f8c-4b92-b4d6-ec1b8dff8b72">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027532" xl:show="new">C0027532</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a823f51-918b-43d4-80d5-155a3c592e3c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_359d5fb7-b669-4b6d-9b8f-cb80fc5edaef">
                                <link xl:href="http://snomed.info/id/74386004" xl:show="new">74386004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f6aee255-a0c5-4ee0-a66d-b131de19ef22">Nasal bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e5a4545-b8ca-48f7-9bce-9956ecb55bad">
                                <link xl:href="http://snomed.info/id/74386004" xl:show="new">T-11149</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb198ea9-99fd-41e2-bf78-c2423c8a82c1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027422" xl:show="new">C0027422</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0215a55a-c96d-4ee9-9010-f3590300fc93">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6955c0fc-60db-4fba-ad47-2fa74f4b4efc">
                                <link xl:href="http://snomed.info/id/45048000" xl:show="new">45048000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_893df247-0db5-4ac1-a9fb-2188f5386b66">Neck</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ff984583-ec75-40b6-8cdb-4bcb86957644">
                                <link xl:href="http://snomed.info/id/45048000" xl:show="new">T-D1600</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1952cfbc-31fa-4f6f-a510-3468da3cca58">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027530" xl:show="new">C0027530</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e053a6e-816f-4571-b616-0550ac66d3c0">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e4715a87-ee9b-486b-8d32-d261a0f649b1">
                                <link xl:href="http://snomed.info/id/31640002" xl:show="new">31640002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_603e3403-7f2c-484b-ba2f-37cdefa13881">Occipital bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_60677a8b-fe54-49d3-a2a0-2c1ea936e47c">
                                <link xl:href="http://snomed.info/id/31640002" xl:show="new">T-11140</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90241055-ccfe-410d-bbf6-b9605726b8f1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0028784" xl:show="new">C0028784</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_49798d71-34a8-4e64-a7b9-070c5c172020">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e491c83a-957a-4e51-b572-786511b36782">
                                <link xl:href="http://snomed.info/id/55024004" xl:show="new">55024004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4ea3770b-6f3c-41aa-9c21-baa5deeb6879">Optic canal</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8f2007e6-df5c-4498-b891-babb2cf3a422">
                                <link xl:href="http://snomed.info/id/55024004" xl:show="new">T-11102</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d1c8c8bf-f15d-4f55-8b08-1848f138ffa5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0450102" xl:show="new">C0450102</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_058bfbe7-5b29-48b4-89c1-8fb1593540cc">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3393447b-3cf1-4824-96ba-90ac77a25bb6">
                                <link xl:href="http://snomed.info/id/363654007" xl:show="new">363654007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_07ba5c22-a874-488d-a89b-21fe00002849">Orbital structure</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b7958391-d4a2-457d-a58c-689257286c83">
                                <link xl:href="http://snomed.info/id/363654007" xl:show="new">T-D14AE</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96e4b1f9-6a5d-4131-9ce3-ad2846fe49a6">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0029180" xl:show="new">C0029180</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b95b2363-0f6b-49b9-a585-c479c55bd719">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2224869-5543-4204-9b3c-c92fa1fdc021">
                                <link xl:href="http://snomed.info/id/51283005" xl:show="new">51283005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e7bd73c4-f111-42a1-8c12-0bba5ac81e3b">Palatine bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14673e5c-e457-4806-bbcc-e4ef1d4570ca">
                                <link xl:href="http://snomed.info/id/51283005" xl:show="new">T-11160</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e517c87b-0049-42a1-959c-788174d9ceb4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222734" xl:show="new">C0222734</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3ee778a3-4195-4686-b645-b3360292ae4b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c682651-48a9-40ee-8dd7-f6d61ca87b4d">
                                <link xl:href="http://snomed.info/id/2095001" xl:show="new">2095001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8e47b16e-4455-4401-8857-ceb24b7632d1">Paranasal sinus</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56353a94-b501-4e0b-81b5-ee5a1a3bf564">
                                <link xl:href="http://snomed.info/id/2095001" xl:show="new">T-22000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fedf95d4-33e8-4e97-bbf1-91785c28b868">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0030471" xl:show="new">C0030471</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c75ebba-c451-4e01-9780-7328db92a838">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62078217-a3ad-4845-bdd0-d80184ee8666">
                                <link xl:href="http://snomed.info/id/24924006" xl:show="new">24924006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d9dffd04-c049-4b0f-a7db-043ac6a44245">Parietal bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_47f7473e-ab05-4467-89cc-9e94927c0132">
                                <link xl:href="http://snomed.info/id/24924006" xl:show="new">T-11120</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c50c48b6-84ed-4ae8-8bc6-47699daf7e85">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0030558" xl:show="new">C0030558</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/54458009" xl:show="new"><emphasis role="bold"><emphasis role="underline">54458009</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Saccule</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/54458009" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB770</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0036029" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0036029</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9843b4a6-4983-46d8-abfe-84dea0bf9fbe">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63cfaf9f-6f9c-44f8-853f-d8765d62cc7f">
                                <link xl:href="http://snomed.info/id/385294005" xl:show="new">385294005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_edecede9-fa24-4239-9c23-c112b8cb9562">Salivary gland</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f587679b-7892-4cc4-a433-f386f9ee3dc1">
                                <link xl:href="http://snomed.info/id/385294005" xl:show="new">T-61007</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c3095e98-e503-4671-b2d0-44e4bef163d4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0036098" xl:show="new">C0036098</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/279726004" xl:show="new"><emphasis role="bold"><emphasis role="underline">279726004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Semicircular canal</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/279726004" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB74A</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0036622" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0036622</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d51a177-33c6-4a3c-82c9-1c5554ba78c3">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_45e8820e-07c3-42c3-bfdc-3a16a3b1ee28">
                                <link xl:href="http://snomed.info/id/89546000" xl:show="new">89546000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3f86ed98-a903-46eb-b453-11fd43d4adba">Skull</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_104600ba-1e48-4d57-b2bb-a1b41a2e2a91">
                                <link xl:href="http://snomed.info/id/89546000" xl:show="new">T-11100</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ea518d27-7d81-4277-be01-eeed0037b46d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0037303" xl:show="new">C0037303</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9762135c-df7a-4945-b8fb-54d9776e4531">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fae284a-4fd1-473f-9ab8-2333574a2ac4">
                                <link xl:href="http://snomed.info/id/49460000" xl:show="new">49460000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f35e3e53-156f-4f68-9247-5d1fbe8683a9">Soft palate</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ea47d93-7dd6-42ae-a1e5-e6d846309d80">
                                <link xl:href="http://snomed.info/id/49460000" xl:show="new">T-51120</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8608bff7-b051-4862-b253-5581f6e76f67">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0030219" xl:show="new">C0030219</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3bde308-5f23-4512-9fb9-2307034b1d34">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dc1fa02a-90ec-4d5b-913d-7a21d90b9681">
                                <link xl:href="http://snomed.info/id/73117003" xl:show="new">73117003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bb078609-3241-45fb-b46a-63038674ebd4">Sphenoid bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b666c173-329f-47cb-989e-9a9ec4ecc707">
                                <link xl:href="http://snomed.info/id/73117003" xl:show="new">T-11150</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9951f32-37e4-45df-825a-fff2f9580379">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0037884" xl:show="new">C0037884</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/22718006" xl:show="new"><emphasis role="bold"><emphasis role="underline">22718006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Stapes</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/22718006" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB430</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0038152" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0038152</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fad9a07-9aed-4e47-82fa-80a82c1f9ffd">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f36ade97-653e-4f59-8832-b3bec5c90d08">
                                <link xl:href="http://snomed.info/id/54019009" xl:show="new">54019009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3289e1b6-a0f8-42a0-ac65-e2712c95086e">Submandibular gland</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ebdac60-b902-40e4-ae09-bdf25fdfa9ff">
                                <link xl:href="http://snomed.info/id/54019009" xl:show="new">T-61300</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c0eebfd-8b3b-4048-b3b8-ee8802f001d4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0038556" xl:show="new">C0038556</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ab1ee5e-fce7-4273-be86-2d638addd6ac">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2e3e2ea4-453e-4f52-abd1-15bbe6dfdac1">
                                <link xl:href="http://snomed.info/id/60911003" xl:show="new">60911003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_594c03be-e95d-4894-a5e2-b7591f220073">Temporal bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a7dca18-ec8c-444f-b1df-9da85393e495">
                                <link xl:href="http://snomed.info/id/60911003" xl:show="new">T-11130</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7b04503-f574-4bdd-9e22-ec5365c9eb5d">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0039484" xl:show="new">C0039484</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a6d8a66e-ea1d-4b94-ba79-7de5eed58f7b">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4bcf194f-1dfc-426b-81ea-206891502c7e">
                                <link xl:href="http://snomed.info/id/53620006" xl:show="new">53620006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e5475356-4c19-4182-b01c-5ac05c8660e6">Temporomandibular joint</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b651e04e-43b9-45a6-8106-94b9e8363d59">
                                <link xl:href="http://snomed.info/id/53620006" xl:show="new">T-15290</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e10492d0-998b-4ae8-963e-bf2a342f63f5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0039493" xl:show="new">C0039493</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_adaabdb1-29a9-461a-8e1f-0dd29e349797">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7c850faa-ecbe-45d8-b283-c2e158561c5f">
                                <link xl:href="http://snomed.info/id/21974007" xl:show="new">21974007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_76304c9e-6a30-4a0a-b3ce-273afc79fea7">Tongue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a42caa07-1e46-43e0-85bf-370b57d997e6">
                                <link xl:href="http://snomed.info/id/21974007" xl:show="new">T-53000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eb090926-002d-4f0f-b6aa-799c5a87031e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0040408" xl:show="new">C0040408</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_61a8b217-fe1e-4c42-ad8f-b431bbde6bae">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d98bf9a-d10d-42a2-8004-5cbcef3f0b33">
                                <link xl:href="http://snomed.info/id/38199008" xl:show="new">38199008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a16ea9a9-fab9-4e3a-b396-950eac18a586">Tooth</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24ad4855-f494-4808-a7d6-1b7743976ad2">
                                <link xl:href="http://snomed.info/id/38199008" xl:show="new">T-54010</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c764dd3d-dd42-4210-84a4-3fa5224b5a15">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0040426" xl:show="new">C0040426</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_14e9996c-8a3f-4cd6-b7bd-26ec81bf1079">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d541c565-9ee8-449c-8954-7f7187c9ca69">
                                <link xl:href="http://snomed.info/id/44567001" xl:show="new">44567001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d4403564-15ec-4caf-b114-8604c4befe6d">Trachea</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b775b7b0-d812-43e5-8c09-37a1a610452d">
                                <link xl:href="http://snomed.info/id/44567001" xl:show="new">T-25000</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_dcc5b893-0f63-4232-b772-203fe08809d4">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0040578" xl:show="new">C0040578</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/51837005" xl:show="new"><emphasis role="bold"><emphasis role="underline">51837005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Tympanic cavity</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/51837005" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB310</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0242255" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0242255</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/42859004" xl:show="new"><emphasis role="bold"><emphasis role="underline">42859004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Tympanic membrane</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/42859004" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB320</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0041445" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0041445</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/81955007" xl:show="new"><emphasis role="bold"><emphasis role="underline">81955007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Utricle</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/81955007" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB730</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0042158" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0042158</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1d877a50-6344-448a-aa2a-2e74d7174d25">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e265f160-a122-463d-a932-d76642f6bb7c">
                                <link xl:href="http://snomed.info/id/110517009" xl:show="new">110517009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2b963486-d795-41e6-ad99-7b07dcb1ad7e">Vertebral column and cranium</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e2e6969-073c-4851-b102-1ea508658239">
                                <link xl:href="http://snomed.info/id/110517009" xl:show="new">T-11011</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4712c161-479e-494f-b754-6cefd95ba7a2">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1266914" xl:show="new">C1266914</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/45006007" xl:show="new"><emphasis role="bold"><emphasis role="underline">45006007</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Vestibule</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/45006007" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-AB870</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0458718" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0458718</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f82ccc38-a449-4b95-9fba-71ce29c4af3d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e4dd1b3-9a4f-42e2-b1d3-c38d2a201b05">
                                <link xl:href="http://snomed.info/id/87166008" xl:show="new">87166008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5a0d0799-3fa4-4d2b-88cb-2dc8c0c967dc">Vomer bone</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1c144fe2-8b5a-47eb-a2a3-165fbe3fca2f">
                                <link xl:href="http://snomed.info/id/87166008" xl:show="new">T-21342</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce3c2339-4941-477d-b87b-f5e1550e5aef">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0242403" xl:show="new">C0242403</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b86b1dc9-3e20-498e-8521-e371174e8176">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20c51f76-0894-46ee-b053-f8619729f899">
                                <link xl:href="http://snomed.info/id/13881006" xl:show="new">13881006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b8fd8a3d-8112-44e4-a2a2-05d578850360">Zygoma</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_743a2fd4-71d1-4db8-a963-5dff4f25853a">
                                <link xl:href="http://snomed.info/id/13881006" xl:show="new">T-11166</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c1dd7a8-2266-4344-8f3b-a9760b54da9a">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0043539" xl:show="new">C0043539</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        
        
    </chapter>
</book>
