<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2488</title>
    <subtitle>Replace DCM code for Margin with SCT code</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/06/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Janet Keyes</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/07</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2488</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Replace DCM code for Margin with SCT code</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>During the review of CP 2408 it was noticed that there are DCM and SCT codes for Margin/Margins/Marginal.</para>
                    <para>SCT:112233002 "Marginal (qualifier value)" has Marginal, Border, Margin, and Verge as synonyms.</para>
                    <para>Replace DCM:111037 with SCT:112233002 throughout.</para>
                    <para>Harmonize meaning to singular noun form "Margin", since uses as a noun refer to singular margin of a lesion, even though there may be multiple characteristics of that margin.</para>
                    <para><emphasis role="italic">[Ed.Note. Check the suggested replacement of the Japanese code meaning </emphasis>辺縁<emphasis role="italic"> ("periphery") with </emphasis>境界<emphasis role="italic"> ("boundary") is appropriate.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note. Update release of standard from yyyyX to past release when FT.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>        
        
        <section label="TID 4005" status="3" xml:id="sect_TID_4005">
                <title>Mammography CAD Composite Feature Body</title>
                <table frame="box" label="TID 4005" rules="all" xml:id="table_TID_4005">
                    <caption>Mammography CAD Composite Feature Body</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6465183b-3323-497e-9d0e-7847f2605651"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1a60fa7c-d371-47dd-8608-6c60de2b9035">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7133de00-6c46-4853-8f73-8f79ae59f3ab">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_629978ac-4dbf-404e-9d8c-51ab59d40895">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_47970c9b-2efc-43b7-99b9-2d79b6b0d6f8">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62c13a2f-0954-41b9-a7ee-33c2f5e5aa6d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c82e36d3-3e03-4fd0-9bee-3becb090c0cc">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94d3e262-071b-4d31-862c-6a0e96c412ab">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d48f6a5-5f0e-4818-a787-d841b19f2883">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c5ef64d5-4329-4057-9361-81c90c7a3a98">21</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_149e84f1-db3d-4c3b-9abd-82afd1e038b1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a733a736-8854-411e-9691-dcf2c99bfb49"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a3deecd-adfe-44ff-94ed-3a68f1f71958">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd55cd0d-7394-485e-8304-bd47ed9a31a6">EV <link linkend="DCM_111037" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">(111037, DCM, "Margins")</emphasis></emphasis></link>
                                    <link xl:href="http://snomed.info/id/112233002" xl:show="new"><emphasis role="bold"><emphasis role="underline">(112233002, SCT, "Margin")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bc60a07d-ed15-45b8-9e54-04735cfb602e">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1fa413e-fc20-441f-ae09-9c51fe6c6c67">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d66ef343-0996-4756-8821-fa6746484d27">May be present only if value of parent is <link xl:href="http://snomed.info/id/129788004" xl:show="new">(129788004, SCT, "Mammographic breast mass")</link> or <link xl:href="http://snomed.info/id/129793001" xl:show="new">(129793001, SCT, "Mammography breast density")</link>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55dd4eac-fc3c-457e-bf42-ed1acdce5879">D<xref linkend="sect_CID_6006" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_5ac64ffd-a1d1-48b4-9cad-016e59f01a28">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Row 21</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">In previous releases of the Standard, <link linkend="DCM_111037" xrefstyle="select: nopage">(111037, DCM, "Margins")</link> was used instead of <link xl:href="http://snomed.info/id/112233002" xl:show="new">(112233002, SCT, "Margin")</link>. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/yyyyX/output/pdf/part03.pdf">PS3.3-yyyyX</link>.</emphasis></emphasis></para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        <section label="TID 4011" status="3" xml:id="sect_TID_4011">
            <title>Mammography CAD Density</title>
            <table frame="box" label="TID 4011" rules="all" xml:id="table_TID_4011">
                <caption>Mammography CAD Density</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_495a2d72-a030-4f09-a546-58009021ec4c"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3462dd24-93e7-4ae6-b7ce-a56e1973bbf1">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d80a6527-76cf-4e12-b990-5b09fac10667">Rel with Parent</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_075e75ef-d6ac-4347-9bcd-a1f9f16d3b0c">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_51ed58fe-f22a-42ae-b563-72d47b3ccd38">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_638a51e8-3207-4a64-ae47-40deb3e96234">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_53d7991f-22de-4644-9640-bfeac0294beb">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7fa64e9b-1134-44dc-8702-567d76a6e71f">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_24cbf1e7-7850-44aa-9190-27f1393e3576">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_987ea695-7e3b-49f4-b058-ca6fd88542ff">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6840d1a1-4969-4691-be32-b401534457c7"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_27da0d94-299c-4fb8-af23-2648e7c7e702"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_93b660ef-3d20-4069-97c5-0c93a2b0d7f7">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_04e30e93-7c0a-49f2-b696-615c397e564b">EV <link linkend="DCM_111037" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">(111037, DCM, "Margins")</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/112233002" xl:show="new"><emphasis role="bold"><emphasis role="underline">(112233002, SCT, "Margin")</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56b91fec-23c7-4f7c-a271-4d119b4421e8">1-n</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44d28d52-4a96-44e9-aeb7-a99479c53b4f">MC</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d752c621-3429-46bd-a243-5e54fccf1e5f">At least one of Rows 1, 2, 3, 4, 5 shall be present</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6cc8e009-84e3-49af-a519-9c03e6799e72">D<xref linkend="sect_CID_6006" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <para>
                <emphasis role="bold"><emphasis role="underline">Content Item Descriptions</emphasis></emphasis>
            </para>
            <informaltable frame="box" rules="all">
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Row 3</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">In previous releases of the Standard, <link linkend="DCM_111037" xrefstyle="select: nopage">(111037, DCM, "Margins")</link> was used instead of <link xl:href="http://snomed.info/id/112233002" xl:show="new">(112233002, SCT, "Margin")</link>. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/yyyyX/output/pdf/part03.pdf">PS3.3-yyyyX</link>.</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </informaltable>
        </section>
        
        <section label="TID 4206" status="3" xml:id="sect_TID_4206">
                <title>Breast Imaging Report Finding Section</title>
                <table frame="box" label="TID 4206" rules="all" xml:id="table_TID_4206">
                    <caption>Breast Imaging Report Finding Section</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_efc51dc0-93c2-4154-9680-8b8d819e3874"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e29a5cdb-14dd-412f-b66e-c21308ccf02d">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a166d46-82be-43f3-9643-9baa023adc56">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c89e45a1-7823-4670-a709-0490091c86e3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14ec973e-23e0-480c-b538-a0112536810f">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4c91455b-f7ca-476b-9786-49b7bdf2ab92">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ba5be963-30c2-450f-a0b7-47005458e04e">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f4b5c11a-bf03-4559-94b8-6620b3e3d78a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dec4dc43-43de-4bf8-ba35-bfb34e7f9da9">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa674745-1663-4043-b5fd-920db91ad3d9">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_abcf4259-49e5-4910-ba8c-db591f1cab2b">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52c488e2-6304-4e78-92a0-2197583f1882">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfe171cd-3506-4164-a50e-2431eb61555f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7bbeb8f6-86b6-4a9b-803b-dcabc426f4db">EV <link linkend="DCM_111037" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">(111037, DCM, "Margins")</emphasis></emphasis></link>
                                    <link xl:href="http://snomed.info/id/112233002" xl:show="new"><emphasis role="bold"><emphasis role="underline">(112233002, SCT, "Margin")</emphasis></emphasis></link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_23895c93-a1b0-4e4e-b7c0-24b52eeb5c19">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7d3067e8-31e4-42f9-acc3-71e3ba5e6e9b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_220c697b-87e3-4450-89aa-f08563351179"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a71b2ee3-9b56-436b-a34c-af4f48e9478b">D<xref linkend="sect_CID_6006" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_66b81863-73c1-4583-b314-5e6d4c7e97bb"><emphasis role="bold">Content Item Descriptions</emphasis></para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Row 15</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">In previous releases of the Standard, <link linkend="DCM_111037" xrefstyle="select: nopage">(111037, DCM, "Margins")</link> was used instead of <link xl:href="http://snomed.info/id/112233002" xl:show="new">(112233002, SCT, "Margin")</link>. See <link xl:href="http://dicom.nema.org/MEDICAL/Dicom/yyyyX/output/pdf/part03.pdf">PS3.3-yyyyX</link>.</emphasis></emphasis></para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        <section label="CID 2" status="3" xml:id="sect_CID_2">
            <title>Anatomic Modifier</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_1f9d5e1e-e22c-4c79-9334-d0fc855fb49e">
                            <emphasis role="bold">20190118</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 2" rules="all" xml:id="table_CID_2">
                <caption>Anatomic Modifier</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a9b23fd-5068-4717-9bf6-d3f02d125c4f">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2cba04db-6aad-491f-9535-9cb6ddcb7b49">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e264bd53-699c-449c-a651-3c58f2dd829c">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5bdf765-9837-42df-891b-110329d322b8">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f7cb246a-b6f8-4cdc-a2df-639ec7208bc9">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ef93f0c9-065e-4a64-94ae-ed346c089b3c">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8290ffb9-65a0-4bcd-9b1f-106405b86293">
                                <link xl:href="http://snomed.info/id/112233002" xl:show="new">112233002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_dd504411-a07b-4761-83ec-4e59db2aae16">Margin<emphasis role="bold"><emphasis role="strikethrough">al</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b108fff0-f64b-4097-a447-92d97220b900">
                                <link xl:href="http://snomed.info/id/112233002" xl:show="new">G-A428</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_139d93a0-ad55-44da-8d07-55994f75ebbb">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0205284" xl:show="new">C0205284</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="CID 6334" status="3" xml:id="sect_CID_6334">
            <title>mpMRI Assessment Type from PI-RADS®</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_163b6f7d-447c-41db-9f24-22bd65fa4897">
                            <emphasis role="bold"><emphasis role="strikethrough">20210714</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6334" rules="all" xml:id="table_CID_6334">
                <caption>mpMRI Assessment Type from PI-RADS®</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cd589a8-2ee3-4969-a0a8-c67b11a95c06">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7c1b929-413b-4e99-9901-e067fbb26319">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e358bb69-660c-4494-b4fb-d8426fed8803">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9ee28f05-8b26-4302-b57d-ee0f2ef52c37">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1cbc2c3f-8b2f-4c8f-820c-c400b5cef60f">UMLS Concept Unique ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_874e5685-5ed2-4ef9-9732-cd0054c639ed">mpMRI Assessment Values</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_647dc3fd-347e-4fb0-a117-b9a1b2b7b219"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7393fe69-acef-411a-b80f-c51d8f6eebcb">
                                <link linkend="DCM_111037" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">111037</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/112233002" xl:show="new"><emphasis role="bold"><emphasis role="underline">112233002</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_52c8072d-561a-4b7c-9898-f2335393b5c7">Margin</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4332fd4b-6204-4202-9a7e-28dd68f837b2"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85784796-8d52-4f3a-aef8-65cf317c5bee"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b90afba1-1072-4d40-b5f9-ef1149663689">
                                <xref linkend="sect_CID_6341" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">Definition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">Notes</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_111037"><emphasis role="italic">111037</emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4b1dac7a-23d4-4d80-9f5f-54980a24216d"><emphasis role="italic">Margins</emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bab6b7c7-f443-44b4-a4d5-dd45d28fe2d6"><emphasis role="italic">The characteristic of the boundary, edges or border of a detected lesion.</emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ba3ae430-1bc6-47bc-aaf7-72ebcccc3dd8"><emphasis role="italic">Retired. Replaced by <link xl:href="http://snomed.info/id/112233002" xl:show="new">(112233002, SCT, "Margin")</link>
                            </emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        

        <section label="E" status="1" xml:id="chapter_E">
            <title>French Language Meanings of Selected Codes Used in the DCMR (Normative)</title>
            <table frame="box" label="E-1" rules="all" xml:id="table_E-1">
                <caption>French Language Meanings of Selected Codes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_090f9188-a249-49a9-82d7-0a9851688cea">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_238a2497-22be-41cd-af6f-3df3a3689ee9">Coding Scheme Version</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0467362d-e7f7-4d4d-a1aa-8a096bbb1a7b">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b2226261-7655-49c3-a0bc-c0295572a723">Code Meaning English Language</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_036bfbde-f73b-46a0-883b-c655056c459f">Code Meaning French Language</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0ddee07e-a331-4b9e-be6b-6d17877467a8">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0c38b1ef-383c-4f1a-b477-fb957585bac6"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3f056232-2f9d-4535-b553-bbe626380a9d">
                                <link xl:href="http://snomed.info/id/112233002" xl:show="new">112233002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_854ccaab-68c8-44b0-bf2a-14b0698a3699">Margin<emphasis role="bold"><emphasis role="strikethrough">al</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4669a351-92cb-4121-b25d-d083456c6616" xml:lang="fr">Marg<emphasis role="bold"><emphasis role="strikethrough">inal</emphasis><emphasis role="underline">e</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eeec1063-fb41-4f37-bb22-7b1e2d78e0bb"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5afbdfa5-f706-4e80-912c-11b68da298d5"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d409c43e-764f-4792-946f-aac7769fe9d2">
                                <link linkend="DCM_111037" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">111037</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c4558ed3-1cce-4104-9c63-3cd45fcc2cbb"><emphasis role="bold"><emphasis role="strikethrough">Margins</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_81de5c8f-fb14-4336-82f5-b4435a4a9d0d" xml:lang="fr"><emphasis role="bold"><emphasis role="strikethrough">Contours</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>


        <section label="F" status="1" xml:id="chapter_F">
            <title>Japanese Language Meanings of Selected Codes Used in The DCMR (Normative)</title>
            <table frame="box" label="F-1" rules="all" xml:id="table_F-1">
                <caption>Japanese Language Meanings of Selected Codes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a2ebcad-b99b-4ed7-abb6-1044db248781">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_72126191-efa7-4aef-81a7-3e4ab94ce310">Coding Scheme Version</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d41965ca-6e67-4f76-80aa-514d54300e66">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_799e56ce-9686-474e-98c4-b95f6d408b86">Code Meaning English Language</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ed2ca850-ba13-4e52-b40a-dc809e58b83f">Code Meaning Japanese Language</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_985933c8-7a72-4201-ac6d-e930236d385b"><emphasis role="bold"><emphasis role="strikethrough">DCM</emphasis><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d0e794b9-b1ac-4e2c-af41-5d045212fe9c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2efefbaa-9f28-4b3d-bc05-2c4c7ece815d">
                                <link linkend="DCM_111037" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="strikethrough">111037</emphasis></emphasis></link>
                                <link xl:href="http://snomed.info/id/112233002" xl:show="new"><emphasis role="bold"><emphasis role="underline">112233002</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1ae5504c-80b2-4621-afe7-bb014ed4c3ba">Margin<emphasis role="bold"><emphasis role="strikethrough">s</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3797afd8-3c0a-4e27-af2e-48701279955e" xml:lang="ja"><emphasis role="strikethrough">辺縁</emphasis><emphasis role="underline">境界</emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
                    
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Unchanged DICOM PS3.16 for reference:</emphasis></para>
                </td>
            </tr>
        </informaltable>        
        
        <section label="TID 3911" status="3" xml:id="sect_TID_3911">
            <title>Plaque Properties</title>
            <table frame="box" label="TID 3911" rules="all" xml:id="table_TID_3911">
                <caption>Plaque Properties</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_95c53fc4-0a8c-4e51-a365-56fe815c622f"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_165b06d6-15f1-416f-acc2-79962a96d2b3">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_070c184d-f316-4192-9e5a-21ee37cc7a12">Rel with Parent</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82d908f6-cc9c-4fa6-a5a7-5862676975c0">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_453901e4-4212-49cd-a47f-f87bb9f397db">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f00f1714-f64f-498b-8727-03092b11f187">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0e079115-0236-4eff-87a9-f6baf46284cd">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e391514-3343-4ea2-a9ea-195a25976f10">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b0074f08-09f7-4427-b71e-2d93d605b0ef">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b23f6907-3b0a-4b28-b534-00386bca6028">2</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7b03621a-6516-469f-b8bc-7a3a4f45c948"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_516c3dc4-5ea0-4256-acb5-44494ea4dd7b">HAS PROPERTIES</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6c04d257-f349-4237-b9ac-18339b18f45e">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2b79f669-784d-41db-bcad-44eadfb748fe">EV <link xl:href="http://snomed.info/id/112233002" xl:show="new">(112233002, SCT, "Margin")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13bc9b85-dddc-45a0-8c12-7aac37434069">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9f30f148-b273-4177-8ecd-7b33cd2e2746">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4f916405-87d9-4bc2-a87b-dcf98ddb4651"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c7b09523-3b97-4fa9-88a9-47c83ea163f3">D<xref linkend="sect_CID_3715" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged, hyperlink targets:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID 3715" status="3" xml:id="sect_CID_3715">
            <title>Lesion Margin</title>
        </section>
        <section label="CID 6006" status="3" xml:id="sect_CID_6006">
            <title>Mammography Margin Characteristic</title>
        </section>
        <section label="CID 6341" status="3" xml:id="sect_CID_6341">
            <title>MRI Margin Characteristic</title>
        </section>
        
    </chapter>
</book>