<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2487</title>
    <subtitle>Clarify de-identification of Requesting Service</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/06/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Chris Bridge</para><para><link
                    xl:href="mailto:cbridge@mgh.harvard.edu"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/12/31</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2487</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Clarify de-identification of Requesting Service</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Requesting Service was added to the General Study Module in CP 1722, so should now be indicated as being in a Standard Composite IOD.</para>
                    <para>It is also a plain text string, so could be retained if cleaned, so include in Clean Descriptors Option.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.15 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>        
        
        
        <section label="E.1.1" status="3" xml:id="sect_E.1.1">
            <title>De-identifier</title>
            <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
                <caption>Application Level Confidentiality Profile Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                                <emphasis role="bold">Attribute Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                                <emphasis role="bold">Tag</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                                <emphasis role="bold">Retd. (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                                <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                                <emphasis role="bold">Basic Prof.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                                <emphasis role="bold">Rtn. Safe Priv. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                                <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                                <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ba661a2-a572-420a-95c1-bc1bf694a70e">
                                <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                                <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                                <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                                <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                                <emphasis role="bold">Clean Desc. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                                <emphasis role="bold">Clean Struct. Cont. Opt.</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                                <emphasis role="bold">Clean Graph. Opt.</emphasis>
                            </para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ae8ef295-818d-478a-aae8-f88a3d26baeb">Requesting Service</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5a46a4bf-d2df-4c8b-80cf-855eac474348">(0032,1033)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_11f26bd6-9a3c-4b9b-a5d2-ccd5688f9bf0">N</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b489bd41-b7b9-4b72-8ec9-4e59f0a3fa5b"><emphasis role="bold"><emphasis role="strikethrough">N</emphasis><emphasis role="underline">Y</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f70f88d-cb51-448f-a114-154bc42f90c0">X</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"><para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para></td>
                        <td align="center" colspan="1" rowspan="1"/>
                        <td align="center" colspan="1" rowspan="1"/>
                    </tr>
                </tbody>
            </table>