<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2486</title>
    <subtitle>Children of CODE Late Contrast Enhancement in TID 3926 Myocardial Perfusion Analysis have illegal HAS ACQ CONTEXT Relationship</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/21</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/12/06</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2486</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Children of CODE Late Contrast Enhancement in TID 3926 Myocardial Perfusion Analysis have illegal HAS ACQ CONTEXT Relationship</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The Late Contrast Enhancement content item in TID 3926 uses HAS ACQ CONTEXT relationship with with its children,
                        which is not permitted by the Enhanced or Comprehensice SR IOD Relationship Constraints. Use HAS PROPERTIES instead.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        


<section label="TID 3926" status="3" xml:id="sect_TID_3926">
                <title>Myocardial Perfusion Analysis</title>
                <table frame="box" label="TID 3926" rules="all" xml:id="table_TID_3926">
                    <caption>Myocardial Perfusion Analysis</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e96ae8c-dd6c-4fa0-93a5-204d52ee893f"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86d506ee-4bd4-439b-991f-000a0fe6b0bb">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_866d9b4a-0552-49c7-86fd-7442409c8bc7">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea1338e7-ac71-4118-b95e-7a7a08919362">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ac8891af-eb1c-41e6-b217-88ee73d7f8c7">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_01f03a15-b7e0-4727-a83d-b4654bba007a">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_94adeccc-e167-4dcc-8e44-1cd222cd03c7">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffbe1fd0-5e56-4526-bc53-e713dd1dee2f">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a712f39f-7a38-4c93-96c8-374870b4d48e">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dce88753-8f3d-4e4e-9e18-15ae8ad8f99c">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01aa7ac1-7015-4e55-9c00-3c54606c8b9a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff5ae340-fb5f-43b1-9d48-3b2c359b0b36"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_81254521-a366-4038-b141-a6d73da3b9c0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fedaf06a-6a7f-4fdf-a1ed-2a65e380a9fb"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6498644a-b323-4fef-a176-4a4fc18b725d"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a3231aae-483d-4256-856f-260f667fdcf1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e66d335-b972-4acd-9130-eefa7fa0e76a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20061213-b072-4697-80e2-d3e6b8e33e88"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9de43f7-acb4-494a-9ac9-de0341903c94">22</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6400a22-b594-4f1f-9982-03a84083086d">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62b29b2a-97aa-45fc-9828-e4917349738b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e7a4e743-7586-41b9-a28d-3a4c97be011e">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19200a90-1be7-4c47-8be5-f1e70bd9bcc0">EV <link linkend="DCM_122664" xrefstyle="select: nopage">(122664, DCM, "Late Contrast Enhancement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4e1f774-2515-4739-8a26-9da3228cbacf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_439adbe2-5891-455a-9e3f-e088b839c8ac">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57e2603a-4ee2-43e7-a68e-b183543097e1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdce735f-e284-49e9-bf92-3ae4dd6cef0c">D<xref linkend="sect_CID_230" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbc287d5-38e0-4508-a8d0-9c7235c14a9b">23</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24aafaba-dc15-4b86-b70e-50541dd02087">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04db46ca-4a0a-4e94-9987-1562bd4833d0"><emphasis role="bold"><emphasis role="strikethrough">HAS ACQ CONTEXT</emphasis><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4707d25a-6320-4fdd-8e91-fa815d695923">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_95208d49-24fa-4d60-a465-7b49a97344b9">EV <link linkend="DCM_122665" xrefstyle="select: nopage">(122665, DCM, "Time after start of injection of contrast bolus")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d96f2d2-8df2-4300-b14f-cd69f404e9cd">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_151f24d8-8223-4260-83e6-6ec575b5df52">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dc287fd4-1098-4d74-8c8c-eb146821a72d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83b295b0-0c51-4fd9-8b14-b62851d6851d">UNITS = DT (s, UCUM, "s")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8487b5bd-4755-4113-9055-e9d56200e775">24</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa2e1ae6-c991-4d9f-8c7a-56f31848df8a">&gt;&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a634cc35-c9e6-4c40-ace7-c1204b1df80d"><emphasis role="bold"><emphasis role="strikethrough">HAS ACQ CONTEXT</emphasis><emphasis role="underline">HAS PROPERTIES</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c308bd3d-3975-4080-b102-7f9e307e60a0">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be33be1a-edf1-4e63-8d0f-e16dfb6a250d">EV <link linkend="DCM_122668" xrefstyle="select: nopage">(122668, DCM, "Time interval since detection of contrast bolus")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_16216384-08c5-43f6-a9cb-4f3fb6c63826">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2c42775-6610-453b-bad2-54ab2dc18bb3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b8caf78-d7d3-4891-b3ee-4551196c1af0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5a29a48-399f-42fa-8750-39feb72279eb">UNITS = DT (s, UCUM, "s")</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>        
        
        
        
        
        
        
        
        
        
        
        
        
        

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        
        
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged, hyperlink targets:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="CID 230" status="3" xml:id="sect_CID_230">
            <title>Yes-No</title>
        </section>
        
        
        
        
            
            
            
            
            
            
            
            

        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
    </chapter>
</book>