<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2482</title>
    <subtitle>Correct inclusion of TID 300 with additional rows</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/06/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/11/28</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2482</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Correct inclusion of TID 300 with additional rows</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Some templates include TID 300 (which consists of a container with sub-ordinate content items),
                        followed by nested content item rows, implaying that those rows are additional children of the
                        included container.</para>
                    <para>This is not a valid pattern for template inclusion, and is confusing to automated template table
                    processors.</para>
                    <para>Correct this by factoring out the TID 300 container content, and replacing the offending invocations with the direct use of the container content item and the inclusion of the new container content template.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>        
        
        <section label="TID 300" status="3" xml:id="sect_TID_300">
                <title>Measurement</title>
                <para xml:id="para_77bd792c-bd9d-4e95-bb1e-f3846ddcda7f">This Template provides a general structure for a numeric measurement, together with evaluations of its normality and/or significance, and the inference source(s) for its value.<emphasis role="strikethrough"><emphasis role="bold"> This structure is instantiated by inclusion of this Template with specific contextual parameters from a parent Template.</emphasis></emphasis></para>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e78884e8-2fba-44cb-9543-7b13a3f3d74f">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87aed517-66ec-469b-848a-051450840c1d">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e039a3ff-536a-4dca-bf00-b2d2fa99111c">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a5457f0f-7d97-406d-aa13-d6be91f9b149">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6d70f93-7707-424a-9d79-3adcab4db4c0">$Units</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3badc168-22a5-4682-9b57-047d848b2f30">Measurement Unit</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6989484c-b1da-4d6a-bda3-d9a7d3583ca1">$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3979d08-a959-4113-aa01-a1840e7cb7d6">Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2220407e-bc25-4ccf-8b5d-0c95d1ddf80f">$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b95a5982-014a-4d8f-a6a4-c5fb5c4a1f7c">Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8bcec88-37d6-4561-b828-e4d6ef3790fc">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e6519c4-97df-4e09-8762-4dd0dff32912">Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d22fd402-fc81-4e8d-a0de-24ba7e68e491">$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2abc1bf-a237-476b-adef-31ef6cada34e">Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_336246da-7a84-428a-9e3e-412fdc412444">$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eb6a2b99-857b-4083-a92f-36f182326bc7">Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba99d0a4-00b4-48bc-8dad-1f0e99ffc186">$TargetSiteLaterality</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5c677f1-074f-4712-9423-9e1bcdaa7d40">Laterality Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a0007a22-85ae-4827-a0f6-8e9bc75e16c6">$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bddb6e6-83a3-4167-b6f2-b5de271ed0bc">Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_380b1baf-5ace-4c43-b1ee-b425172579c8">$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2aed46c6-eac2-496c-882c-8953fb18a4fc">Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_311f48b5-37c5-440e-8687-ff61aac2c7e2">$ImagePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0291ccff-9df5-4b97-a117-5f245e2d5d4d">Purpose of Reference for an image used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9972894f-aa6a-4168-83c4-0a734f412a88">$WavePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82836268-0d2c-4de6-823f-d567f7fc929e">Purpose of Reference for a waveform used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5b3fff08-495a-43d7-8d44-8a00cb2be52b">$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0a69d6cd-aaed-4021-8451-c1abe771282d">Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_332e3c5f-951e-4610-96e9-d9e7281fcb11">$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fef43e6-99a3-40cc-b156-c9054b6db484">Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c441e1b9-7b0b-4e20-b439-5fb3657634c0">$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c55737a4-e74a-495a-a5f0-a2ad15221e59">Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e779ad8-08f2-45ac-9c31-29162f80ae8d">$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_76ba2922-f81f-49d9-83b3-8ef04f67c183">Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b8bceade-77cc-42b2-b249-19b0f692c2cb">$PrecoordinatedMeasurementMeaning</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7fe7783-e20b-4fad-8955-61c6ab56ac58">Coded value for the precoordinated concept name of measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ab8fefe1-5cfb-4d98-bd8f-473072340e65">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_ef0dbab2-a679-4f50-95d5-3f82597e6279">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_a17f8f3a-4c87-4b2e-8c92-218843e7986f">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_300">
                    <caption>Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72040574-5d06-4448-92d3-65d64029aec2"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6dc1a5bb-799d-4ce7-b116-2de6f00399b0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ada3f541-03e1-4c32-aca3-f7f3d0de93e9">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_34201b00-0939-4acb-975d-63b09c385b07">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_104a2ec7-1391-48f6-b7dc-c5f94a8bb57a">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0699ebc9-be03-4846-a7b1-e8c504fd0ae9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_40849f85-f55e-4dd9-bc80-7af5c0e2a872">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cd9bf78e-2ee9-47a9-8a55-5cf98072a759">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9856b597-aeef-4056-a98c-25b47f0aabcf">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e932889-0764-40b5-9f5e-ac3845d6f933">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b175a93-7c5c-48bc-a5e5-380db6283009"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ec6fe93-5cb0-4758-8adc-deef5678010b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5fe8320f-931e-4eec-91a8-f8d7ae6d7f00">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48165cbf-5ff1-4353-9c7b-c05569a0066b">$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a6d1fd64-a1d1-4245-8dc5-88b325d3094c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ab6a36e-54ef-41db-a7c7-de35a9843624">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5043dfda-6fa9-4044-b601-cb8254bff80b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b0e7cc06-ed22-40d7-ae42-3e8831a76b76">UNITS = $Units</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_30n" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">M</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">$ModType = $ModType</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$ModValue = $ModValue</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$Method = $Method</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$Derivation = $Derivation</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$TargetSite = $TargetSite</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$TargetSiteLaterality = $TargetSiteLaterality</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$TargetSiteMod = $TargetSiteMod</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$Equation = $Equation</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$ImagePurpose = $ImagePurpose</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$WavePurpose = $WavePurpose</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$RefAuthority = $RefAuthority</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$RangeAuthority = $RangeAuthority</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$DerivationParameter = $DerivationParameter</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$DerivationParameterUnits = $DerivationParameterUnits</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">$PrecoordinatedMeasurementMeaning = $PrecoordinatedMeasurementMeaning</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">2</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$ModType</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1-n</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$ModValue</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">3</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Method</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">4</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Derivation</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">5</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1-n</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSite</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">6</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSiteLaterality</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">Defaults to D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">7</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSiteMod</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">8</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS PROPERTIES</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$RefAuthority = $RefAuthority</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$RangeAuthority = $RangeAuthority</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">9</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INFERRED FROM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">NUM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$DerivationParameter</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1-n</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">UC</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">XOR Row 10</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">UNITS = $DerivationParameterUnits</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">10</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">R-INFERRED FROM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">NUM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$DerivationParameter</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1-n</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">UC</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">XOR Row 9</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">UNITS = $DerivationParameterUnits</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">11</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INFERRED FROM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">UC</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">XOR Row 12</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Equation = $Equation</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">12</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INFERRED FROM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">TEXT</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">UC</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">XOR Row 11</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">13</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1-n</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Purpose = $ImagePurpose</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">14</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1-n</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Purpose = $WavePurpose</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">15</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">16</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">TEXT</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">16b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">CODE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">$PrecoordinatedMeasurementMeaning</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">17</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS OBS CONTEXT</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></para>
                                </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">18</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INFERRED FROM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">COMPOSITE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">19</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">HAS CONCEPT MOD</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">U</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_c568a2c1-03b8-4849-9910-d9efaf957365">
                <emphasis role="bold"><emphasis role="strikethrough">Content Item Descriptions</emphasis></emphasis>
            </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Rows 2, 3, 4, 5</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Row 5</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Rows 9, 10</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Row 13</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Multiple SCOORD Content Items may be necessary to describe the source of the measurement. E.g., the measurement of an angle between two non-intersecting line segments requires two separate POLYLINE SCOORD Content Items with the concept name of <link linkend="DCM_121223" xrefstyle="select: nopage">(121223, DCM, "Arm of angle")</link> conveyed in $Purpose.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Rows 13, 14</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough"><link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be specified for $ImagePurpose or $WavePurpose as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Rows 16, 16b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with <xref linkend="sect_6.2.4" xrefstyle="select: label"/>. This composed concept name may be rendered by a display application. It may be supplied as text or coded concept or both.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Row 18</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="strikethrough">Row 18 is a reference to an RWV that describes how measurements were made in units that differ from the stored pixel values in the images referenced in Row 13. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</emphasis></emphasis></para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>


        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new template to DICOM PS3.16 as follows (no changes to what was extracted from TID 300):</emphasis></para>
                </td>
            </tr>
        </informaltable>        
        
        <section label="TID 30n" status="3" xml:id="sect_TID_30n">
                <title>Measurement Content</title>
                <para>This Template provides a general structure for the content of a numeric measurement, together with evaluations of its normality and/or significance, and the inference source(s) for its value.</para>
                <table frame="box" label="TID 300" rules="all" xml:id="table_TID_30n_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para>Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$ModType</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Modifier Name for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$ModValue</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Modifier Value for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Value for Measurement Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$Derivation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Value for Measurement Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$TargetSite</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Value(s) for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$TargetSiteLaterality</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Laterality Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$TargetSiteMod</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Modifier Value for Anatomic Location of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$Equation</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Coded term or Context Group for the equation or table from which the measurement was derived or computed</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$ImagePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Purpose of Reference for an image used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$WavePurpose</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Purpose of Reference for a waveform used as a source of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$RefAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Bibliographic reference or authority for statistical properties of a reference population</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$RangeAuthority</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Bibliographic reference or authority for the normal range of the measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$DerivationParameter</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Coded term or Context Group for Concept Name of a derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$DerivationParameterUnits</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Units of derivation parameter</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>$PrecoordinatedMeasurementMeaning</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>Coded value for the precoordinated concept name of measurement</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para>
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para>
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para>
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 30n" rules="all" xml:id="table_TID_30n">
                    <caption>Measurement Content</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para>Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c515a4c2-545c-43c4-8e41-ade857100b6a">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c94a32ec-4213-4104-9bab-c3f6db880f93"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_689822ca-4490-4ddc-ab4b-fa40eaaf2ee0">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fdc1a0e-c8a0-46d7-96d9-6c3d8ee2531c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b0eebe5-a3b6-4489-8519-995ab0fb2387">$ModType</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72a99565-a981-43c6-b839-2ea70017869b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f7c2de4-d8f4-4da7-b290-b85c8d6374a9">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f35b74d0-e5b2-43a6-aa54-fe99d4fb9621"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e9202f3c-77aa-4877-8002-f52a780921c3">$ModValue</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1a38665-2780-47a2-8288-b2ac487c6998">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b94e2514-7250-42fa-9b08-6b893ad01093"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30586168-f816-4111-8cdc-f11f95a81d0b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f382fab9-034b-41e1-aa6f-a7185be151b9">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b72d8b6-ed15-4a08-9b5b-289774f7cf5c">EV <link xl:href="http://snomed.info/id/370129005" xl:show="new">(370129005, SCT, "Measurement Method")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c07f112c-405c-4d23-be39-6a581360dcae">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_838f090d-85d8-4634-8fd7-e2fa6f6039b1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6560d8a-8154-45bf-94d2-37153ca9099f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2db623f9-eb56-4064-970f-909c99c2a31f">$Method</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7e5425fb-b11e-4ce9-8481-bf4a3747daf4">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6b34bf6-827a-40ba-8b4b-be7b2de154d3"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04f58196-f7fe-45be-b29e-ae83c4d92fdc">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5542c40a-7059-4932-b225-434e716ad737">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b90b1fb-e270-4b78-800b-1d187de4e1d5">EV <link linkend="DCM_121401" xrefstyle="select: nopage">(121401, DCM, "Derivation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ca8df5bb-1433-4349-8f74-72b58b00b6d9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cda9ee73-45c3-402d-8c97-9b7488003a2b">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dabc7969-5f11-4e95-90a1-c456bcbdb6a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c43c691-50c8-4531-a525-c7ee0892e657">$Derivation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_842a90c7-9b2c-4e1b-9d86-07032d12440c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5831500-d717-4acd-b9f0-e1830aa51c47"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5bcc1fd5-adc6-40f2-9d60-ac63e06e3ae6">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52d994f1-7970-430c-98c6-d6f793b4fc94">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5eb269ab-ac5b-4d94-8a57-65f11a3120c3">EV <link xl:href="http://snomed.info/id/363698007" xl:show="new">(363698007, SCT, "Finding Site")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_620460a5-326b-427c-bbf4-b91e1aadb9f0">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a5fb68de-67b6-48ad-a052-670d176b1a63">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_721786ea-c21c-4c3a-9548-550c54e19cd9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ecabefa-537a-4f14-8b77-f5d7e7abc868">$TargetSite</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d351ac50-bc5b-4990-95e0-590c7c311491">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ea5b580-7476-4ccd-bf8d-1c4aae332342">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_53959fa5-9bba-4765-80fd-5b7a9880ddc8">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e500ea97-1971-4b1e-b316-09423b1e2458">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55011eae-faab-453d-89c5-60f2b8e7a403">EV <link xl:href="http://snomed.info/id/272741003" xl:show="new">(272741003, SCT, "Laterality")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0961a671-0b3c-4ded-978a-5830e6c0880e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_27501979-c2eb-4352-a929-85fa10dc148c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d067a1e3-0284-4cfc-beac-2c127ea50637"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ea85369-73ab-4414-bc58-9e5098ac7d70">$TargetSiteLaterality</para>
                                <para xml:id="para_760eb9f5-5cb5-4415-930b-9df9a996ac58">Defaults to D<xref linkend="sect_CID_244" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c84a9a9d-404b-45f3-95e6-a0788c85a1e4">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fb178ea-cdaa-40bc-be05-5206fc09fbf1">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69f456db-3070-400c-bc29-ee9e3e11d64f">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c49d44f8-3d49-40da-a2f4-70949603f29c">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae97e081-9e86-4c97-90d2-d44ff283b411">DT <link xl:href="http://snomed.info/id/106233006" xl:show="new">(106233006, SCT, "Topographical modifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2ce576e6-dbff-44ee-a636-8edcd0056567">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d790e090-8302-446a-a659-1c295bfc889d">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4031f3f1-b19e-47da-b68d-974b820fddb1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_588bdde1-6eb6-4381-9df6-bebc5afefb83">$TargetSiteMod</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55fe4e86-cca8-4940-a540-f4671dc0299f">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3023b9dd-13cd-4226-8581-b965fcf2707b"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fcd20d74-1731-4c10-a82b-f5f833fd15e2">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43b37530-680e-4a91-b528-d23f15ae3074">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48f871f5-996a-4c76-9e96-4770562ac907">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5c29e082-0dcf-4fa2-addb-92519d41714e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_690ef0da-0abe-4c43-909d-1da7dbcdf06c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd9608ef-d2bf-4299-ba69-b5085bd20e57"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1724ebe0-9179-4a20-a841-10c211c21038">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_458c2786-5228-4d78-87ec-e3afc106df26">$RangeAuthority = $RangeAuthority</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_43381e20-6ef0-4650-9d9e-da46ec75ba79">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_daee4ae1-1990-4e4b-8bbb-6b005058e282"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f26c7f9-c49a-4ca2-8858-5c435b7ba3a3">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3d9d6bef-6713-417b-bf49-7b47aa74b693">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb72713f-a9f4-4dd1-ae98-b38b33de4880">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a1c094ed-6a6b-4b41-8f22-1d353f747243">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8de34b01-9262-4b03-9511-a5aa39fa4794">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4775203-ee1a-4b1f-a1cd-4c54d7fe8dab">XOR Row 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfcb79da-82ef-4927-9a4f-a996dd7c6757">UNITS = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd9992da-41ce-4e0d-92fe-86318d362bd7">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48f7e292-83e6-4fd0-8fe9-5ad09f47f479"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84f7a34d-f097-4ab4-9090-c41cc80d520d">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_baf0060c-0a8a-4ef3-bc44-0d8b2b551943">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_625ca83b-7a41-49f7-85e3-3438077fb640">$DerivationParameter</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9250282c-225f-47fe-af9d-c8792a8deb2f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1c647934-4d63-4c9a-b7dc-4d86f52c1df5">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59c20b99-32ea-4634-91d5-dbe8957d0757">XOR Row 9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fd8f155-8c00-4238-9d8d-5871d87443bc">UNITS = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10e094a4-53db-45d0-92fe-b6b6d42d0a13">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5766072c-5bd3-4569-acf4-6daeb654f73f"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85e15b2f-722e-41e3-9a73-84710fd3cbaf">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03dfdd98-b520-4631-86c9-fb0be07aa719">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dec0e69-4ca9-46b7-8078-b1d9eeea7c9e">D<xref linkend="sect_TID_315" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1d2b6f4b-1493-4e02-aeac-6d3e9879447d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_aaff5d2c-9786-4aed-a9d9-6e6bcedbb7f9">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d8041e0-b30d-4e10-81ad-3b929b364a05">XOR Row 12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70492950-ae80-4731-b562-31b8b1b33f47">$Equation = $Equation</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d2fdd423-32ea-4648-b480-9d09020900f9">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67bae056-7e0e-4030-ad90-6efa9cfe1d59"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d30b8d9-4cc4-420b-aeff-12193d252f89">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6fb0a06f-4888-4155-883e-e2e2a9d1133e">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8dcdc31f-b3d8-479f-b25f-67ef7ecf2501">D<xref linkend="sect_CID_228" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b8bd265-dec6-4c3a-a698-b195890ca5e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a76c7edf-04cc-4626-9af1-9fcc2f783890">UC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5c175e6-a7af-4f17-ac9b-54f386e648ea">XOR Row 11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a623f5b-403f-4444-a751-c3f205c9f538"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_770d16b5-21b5-4887-96bd-6aeaf6afd2c8">13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_10c8009f-cdf8-481e-a705-02fa7087fc41"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3918619-21e2-4ed1-b694-45f56b4953aa"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_161efed5-07f7-4bc4-9c2f-baffaed7e8f1">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bf78b3b7-4ed9-47bf-88a9-18efa573270c">D<xref linkend="sect_TID_320" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1a45d45-0533-4a14-8fba-e85f2a151d8f">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_72e4002f-993f-410a-99d7-d699a37f8340">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eaaa3c9a-40ef-4fa0-82e2-39369442ba24"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_22d6c3ff-aaca-45d7-b0a6-d0109f903293">$Purpose = $ImagePurpose</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f1f348a-5796-4a87-9ba3-f2889749259b">14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_451e74d0-aac0-48d2-99fe-d88c8f19c95e"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_efe5adcc-e9c9-4812-badf-d6d44e61aa4b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c40f07c9-ca79-4b2f-8065-7325242d588b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e79da970-e41b-4528-b581-450ab8af39d1">D<xref linkend="sect_TID_321" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c274ef43-d146-4065-9802-fbe6c4f48ca2">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3e6d8f0a-39ac-4c87-972c-e242109f5fe1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ea7f370-a961-4816-867e-e6d3d41763d2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_594b4882-e970-47db-9edb-c64c94f3421c">$Purpose = $WavePurpose</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7aa30b0-48fa-47d3-b01f-526dbfd309fe">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de9abf82-2580-4ed2-b827-66fd38bd0bb8"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_248194c6-08ea-4081-a987-67ee3386cfdd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e5aca031-f439-4c73-93e7-04a9349d9f57">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03e11b2f-4ca7-4965-a63f-d424952bfc53">D<xref linkend="sect_TID_1000" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41f7b608-3448-4e63-af78-f8b995bdc738">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dcd4a6b-302a-4a27-8895-a530a154ee07">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_52ef5229-812f-4efb-ad81-46d5454f112c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5a0cce9-8350-4e8f-80ed-f5d55206196b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a041534-7087-4287-9602-af9928c73c30">16</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56a190fb-cd34-40de-8d6d-4eec35958b13"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d897d7e7-1ced-4087-b3ad-7137de920360">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1d9895b-c478-4112-8afc-816cb4b3edd1">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a836245-f544-4e0f-ba7f-14532c3196d7">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_92ace882-b4c5-4d3c-9240-e5779a2238f9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2562d454-f655-49a8-8fab-182e76a9f03a">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35dfcf1c-1a3c-4ddc-b49c-1bfbc9d51050"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b1a89c74-4147-43f6-ad3d-ea013444ce4a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_39645f16-a661-4fff-b808-43d249bf3c2a">16b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2cc16679-38c0-44d9-a8e1-87e062f6d2a4"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e27ef2f-0ecb-4c1a-9aaa-89f5a4612b1a">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38aab58b-3b47-4c7a-9aa1-ee33a18b816b">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdab23b5-7e4b-425b-b560-3dfb544ded96">EV <link linkend="DCM_121050" xrefstyle="select: nopage">(121050, DCM, "Equivalent Meaning of Concept Name")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fa96914e-c7a6-45a4-aa63-7cf006665673">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0ac6770-d490-40fe-b9d0-e5de0668ece3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcb0b6a1-000d-4c79-88c0-5abbfc33cccb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73c835c9-470b-4395-be30-6cef3b373317">$PrecoordinatedMeasurementMeaning</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26c23e39-a9c1-4701-98a6-106282354629">17</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc5a3807-a0c7-4d54-8052-d82df186390f"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8cac7bd7-9c79-4ce1-a84f-242d236c7ef0">HAS OBS CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d5d1c26-bcdb-47f2-ba7b-63bfc34170ef">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f59c744d-2c77-475f-875c-a9dd0dd3e259">D<xref linkend="sect_TID_4108" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c39a5a76-3780-4adc-9520-3a00ee799552">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35798212-6c86-4213-bba5-94e3d4b03a09">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b38af8cb-5096-4c9b-a325-9a5b55dc1a3a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd31b1f0-0ee9-4a19-8749-73a389d7cd88"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_673b4f2b-1fd4-42c3-be28-2691c914334a">18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f93ce24f-3cce-44b5-9f68-d29922a19e46"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ec8b82d-6fae-4ff4-b67a-531effecdc45">INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6706747-38ef-49db-a6a8-2751edfb08d9">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f828a919-5902-43ad-b84c-7be92deb8eeb">EV <link linkend="DCM_126100" xrefstyle="select: nopage">(126100, DCM, "Real World Value Map used for measurement")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a8a2b73a-12e7-4d5a-8325-a62f25249248">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8dbd6f45-fb6e-4182-b964-a80797c29990">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_202d1931-abc7-450b-bfc3-5abc88d95a7f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9054b3b9-cd7b-4eb5-9a63-a9b44b2200a7">SOP Class UID shall be Real World Value Mapping Storage ("1.2.840.10008.5.1.4.1.1.67")</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34625822-8896-42ed-b521-0531c03174c9">19</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_110b18ac-27da-4e25-b8d3-5e3fb7964492"></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edce7dc5-cb16-4585-9226-e1e35e81564b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a690c6ad-8e82-4829-bc89-20e99aec550b">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_183a95cc-a257-4743-9765-b8b2e889ae16">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e0678672-8b48-4285-b9f3-796f47903fcf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c8517cbc-dbf3-44b5-bc57-8782ac895159">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5005f9fc-75ba-42bf-a3e3-74b3161efaf5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be8acca7-0043-4ec7-901f-46c966708429"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para>
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_effc493f-84f6-437c-84af-31ff7bf9c06e">Rows 2, 3, 4, 5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_33fc3488-12f8-4222-ad96-24b55739f20d">The HAS CONCEPT MOD items allow the explicit definition of terms for post-coordination of the measurement concept name. Additional post-coordinated modifier terms may be included in a SOP Instance based on this Template, in accordance with section 6.2.4, or as defined by Templates that invoke this Template and explicitly define additional post-coordinated modifiers (e.g., TID 5203).</para>
                            </td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para xml:id="para_fcb505ed-af0f-4b3c-a679-ff3afdfa0d41">Row 5</para>
                            </td>
                            <td align="left" colspan="1">
                                <para xml:id="para_eb15fbee-f367-4d74-9be2-986aab9259f2">Finding site may be multiple when a region of interest spans multiple anatomical locations and there is not a single pre-coordinated code describing the combination of locations. E.g., when a maligant, inflammatory or traumatic process spans actual or defined anatomical boundaries. There is no requirement that the multiple locations be contiguous.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77cb86d4-242d-4dc3-aae4-96cae1a4324e">Rows 9, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a50d2d4d-b98c-4f68-8e87-61e2fad1c693">The INFERRED FROM items allow the specification (by-value or by-reference) of numeric values that were used in the derivation of the numeric measurement of Row 1. The nature of the inference is not explicitly conveyed; it may be implicit in the Concept Names of the measurements. Inference by-reference is valid only in SOP Classes that permit the INFERRED FROM relationship by-reference.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c8e7caaf-dde9-4374-92ac-7ac590731ee5">Row 13</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67cdfc1f-94ef-46f1-8788-5b3a076eae6e">Multiple SCOORD Content Items may be necessary to describe the source of the measurement. E.g., the measurement of an angle between two non-intersecting line segments requires two separate POLYLINE SCOORD Content Items with the concept name of <link linkend="DCM_121223" xrefstyle="select: nopage">(121223, DCM, "Arm of angle")</link> conveyed in $Purpose.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59a58317-74ca-4d14-8a57-3d1f319d9129">Rows 13, 14</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d082de9f-2615-4bb0-b7c4-cd96bc0e503a">
                                    <link xl:href="http://snomed.info/id/260753009" xl:show="new">(260753009, SCT, "Source")</link> may be specified for $ImagePurpose or $WavePurpose as a generic Concept Name when there is a desire to avoid having an anonymous (unnamed) Content Item.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8478bcd-4ae8-41d3-99e5-3029ac1c531d">Rows 16, 16b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8adf7435-8928-478a-a82f-a4eabcc8d850">Equivalent Meaning of Concept Name allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordinated concept modifiers. The concept modifiers may include those specified in this Template, in a Template that invokes this Template, or at the option of the creating application in accordance with <xref linkend="sect_6.2.4" xrefstyle="select: label"/>. This composed concept name may be rendered by a display application. It may be supplied as text or coded concept or both.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_228b5e1b-b7be-434e-a77a-56dd1279b471">Row 18</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7b31254-30fb-4b6d-9c23-60fc0150cf6e">Row 18 is a reference to an RWV that describes how measurements were made in units that differ from the stored pixel values in the images referenced in Row 13. E.g., for a PET SUVbw measurement, the mapping from activity/concentration units in the referenced image that was used (and which may be reused for measurements in the future) may be encoded in a referenced RWV instance. This reference overrides any reference in an including Template (such as for a Measurement Group).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID 5203" status="3" xml:id="sect_TID_5203">
                <title>Echo Measurement</title>
                <table frame="box" label="TID 5203" rules="all" xml:id="table_TID_5203_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_38bf314d-b635-44c9-bb00-52e771a9ad0b">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18f3416e-bd26-42c6-afea-82d8c4376b19">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae3c29d1-23e0-4b4e-85f9-03eb6f0cb1f1">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c0d53c79-d2e1-49d2-8264-203b24ac5ca8">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b364229-a2f3-4e7a-8854-0efb1dcf5385">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a52febf-ac24-4ea6-81ff-1a1f961d953b">Value for Measurement Method</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_85827e60-e6f7-4be0-b924-bc3325def226">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e6bad085-dcf9-4a96-8f24-ee26c814d62e">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_e9454cce-03eb-41ff-875c-717a58e50dc0">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 5203" rules="all" xml:id="table_TID_5203">
                    <caption>Echo Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0dbec894-c07e-4a3f-b740-3fa1df8e17a5"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08cbee69-613b-45f0-b1d3-866fd67c391c">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e27a19bc-aff9-4181-9825-a335dd1b7e63">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_64a75ef7-0efd-464e-9fa7-b77e382a536e">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_538567b1-bf71-4e8d-92d7-e1c53f634be9">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7e3cf7e8-60bb-47d3-81a0-b3e7bde304b2">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_625592f7-05ac-48f3-afdd-31d5e09c7333">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e61ecf5-d746-435e-bbd8-50117d11ce3b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a1c7e91-cd36-40dc-9676-ada827bf7b3c">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c9d5742-895e-4bc6-a1e8-e3907179c03a">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_84ca58e2-3179-4031-a350-857ddf3ffd78"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f3410ded-6f23-4f0e-84d0-4f13ef685afc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff41e6b0-e1ff-4ec9-a022-a3e763ba3df5"><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis><emphasis role="underline">NUM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d07c008-f776-40ea-bda0-75f25f58a74f"><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                    </emphasis><emphasis role="underline">$Measurement</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae361ecb-9a5d-4647-b5ce-0ca9bbfef59c">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b152dc2a-dc92-4a95-bd25-92f4e9e607a6">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_263dc6b9-cf8c-4f1b-b2a2-75c034e9f2d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1017dfe0-4a97-43d2-b1e3-a6889715fa24"><emphasis role="bold"><emphasis role="strikethrough">$Measurement = $Measurement</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Method = $Method</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSite = B<xref linkend="sect_CID_12236" xrefstyle="select: labelnumber quotedtitle"/>
                                </emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSiteMod = B<xref linkend="sect_CID_12237" xrefstyle="select: labelnumber quotedtitle"/>
                                </emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_30n" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">M</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_27a3d13f-6476-4291-aa4e-221916ab5e57"><emphasis role="bold"><emphasis role="underline">$Method = $Method</emphasis></emphasis></para>
                                <para xml:id="para_d9cd1a5a-61e7-43a4-a72d-6bcd45e7a1ac"><emphasis role="bold"><emphasis role="underline">$TargetSite = B<xref linkend="sect_CID_12236" xrefstyle="select: labelnumber quotedtitle"/>
                                    </emphasis></emphasis></para>
                                <para xml:id="para_0e2ef613-dad2-484e-bcf8-556e9748e92a"><emphasis role="bold"><emphasis role="underline">$TargetSiteMod = B<xref linkend="sect_CID_12237" xrefstyle="select: labelnumber quotedtitle"/>
                                    </emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0dc716a-7039-4e25-aeed-4dc5c22fa566">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1c474276-b809-442a-b484-5f4ddff39417">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74a79315-118f-40cb-83c9-6dd8b2c50f8f">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ccb9952-d302-4f1d-9337-dc3a08405eb8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b29ff2da-becb-44dc-976d-623f920e7fc2">EV <link xl:href="http://snomed.info/id/260674002" xl:show="new">(260674002, SCT, "Flow Direction")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a274c404-d000-405e-91ea-2622008f41af">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f2cce4d0-0cb5-4334-89a5-b6596fdb01aa">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41d0fb73-0641-44a6-89fd-d7d3bbe52562"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54297294-cff8-4c69-856e-e9a07f6ee5c2">B<xref linkend="sect_CID_12221" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_caa40544-3d3d-4fa3-a221-ceefa08749c0">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_424364e9-f30b-41cd-bc0e-d04ef78da643">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a94f090-7996-4c1a-9cd3-33baff1319af">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b684a76e-efe0-4755-873b-bd0513f82675">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87ecc1b3-2306-4bc9-95fe-9e49f8f5d01d">EV <link xl:href="http://snomed.info/id/272517003" xl:show="new">(272517003, SCT, "Respiratory Cycle Point")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1af2a524-698e-407a-b4d2-1d5a3a7d39a7">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1df195cc-9d1e-41d8-808f-247276d8b8b7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e399b38-6731-40d1-bd88-4a6068c489a1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_981812ee-2423-4135-bfd9-22045e036e3c">D<xref linkend="sect_CID_12234" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3f4de3e-3826-47f0-ae9a-bf7583d21c5b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4703874-8403-4b8b-94fd-9331e5e3b2fd">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bb7d096-2f8c-45bc-b48d-8df17ee08d3c">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f42468d3-79de-4a21-b2bf-c8ce201cbfc8">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ec3553a9-0294-463e-a4ba-d6358c5e5506">EV <link xl:href="http://snomed.info/id/272518008" xl:show="new">(272518008, SCT, "Cardiac Cycle Point")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4004ec93-ce1b-4b20-ada3-937156d673ba">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8a5a43b2-640b-40d8-b3bc-9e01c4d0ce6c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1e04d7d-bf0d-4dde-b930-6dbae28c7299"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_01c0d142-e836-439a-811d-c43bbd98f0d0">D<xref linkend="sect_CID_12233" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_59b3cf4d-5712-4889-8001-0e313754a343">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cc4df44f-710a-4caa-880e-513d634a0654">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_460e52c7-310a-4602-851e-14c87653f135">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6da9ad1b-25e3-468c-a4af-27ea271bb661">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3e056019-5bc5-46a8-a42b-38fc0b834e43">EV <link xl:href="http://snomed.info/id/399264008" xl:show="new">(399264008, SCT, "Image Mode")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea7c863b-9898-4106-8026-aeb651cf3484">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e49e17ae-fbfd-4664-a4b2-70a54c83ad80">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2d9ce6ef-a301-4f40-964f-750b56fc420c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bd3c575-da01-4ca4-b747-cc8fb4a7d986">D<xref linkend="sect_CID_12224" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a13ff088-89bf-45cd-9f99-0bfeaf6a230e">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_555a8b6f-f41c-469f-95cf-aae2895f36dc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c82ec46f-e056-4480-b8b5-80c065406cb0">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f466e887-30df-4b85-91c0-08b2aab3e864">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_54fc5643-7dfc-459e-a3c1-4552273c98b9">EV <link linkend="DCM_111031" xrefstyle="select: nopage">(111031, DCM, "Image View")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cef7ffa4-c43f-4016-93cf-5360cfc746c4">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cf588b77-e990-414e-9059-ce316e4783a3">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e01be5c8-3ad9-4ce1-8d97-231e57191fd6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2862e1d1-40f5-4826-8ff6-2efc0d3919e9">B<xref linkend="sect_CID_12226" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f5c8c98-f3a9-4536-a248-d5b76f574f31">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e17a6306-3486-466d-a8bc-3c249e961883">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31c587f9-b625-4903-bcfe-64904fa73311">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_801f52c7-04a0-4d46-9979-71dc41b9db7d">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_65c6e9d9-7521-4c2f-8e61-78fbe94535f7">EV <link xl:href="http://loinc.org/18139-6/" xl:show="new">(18139-6, LN, "Stage")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_39aed391-80d7-4070-81c0-21acd31f2f15">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19f7df73-e63c-4cdb-bfbf-2a0e544bb6a8">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4049f3a3-c621-4be8-b641-62bbc2b7d4a0"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79399149-a2b0-41c7-9f05-97543d86772d">B<xref linkend="sect_CID_12002" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_94c196c1-7b84-4ad9-a4f1-ceeb990899ce">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4ea349f-fbe6-406d-b661-b0d4e23c6c01">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5656f413-7706-4047-a09c-704877e14ea5">TID 300 specifies an "Equivalent Meaning of Concept Name" that allows the creating application to specify the preferred composed concept name representing the measurement and the associated post-coordination Concept Modifiers (e.g., the ASE terminology described in <olink targetdoc="PS3.17" targetptr="sect_N.3" xrefstyle="select: docname label quotedtitle"/>).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        <section label="TID 5223" status="3" xml:id="sect_TID_5223">
                <title>Pediatric, Fetal and Congenital Cardiac Ultrasound Measurement</title>
                <para xml:id="para_b8083fd5-17e4-463a-8756-d16d8764e87b">This Template provides for the post-coordination of a measurement with a variety of concept modifiers and acquisition context observations. When invoked from <xref linkend="sect_TID_5222" xrefstyle="select: labelnumber quotedtitle nopage"/>, the measurement concept is implicitly post-coordinated with the concept modifiers of the Measurement Group (<xref linkend="sect_TID_5222" xrefstyle="select: labelnumber quotedtitle nopage"/> Rows 5 and 6), and with the Finding Site of the report section (<xref linkend="sect_TID_5222" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 2). The finding site may be further specified within this Template by the Target Site and Target Site Modifiers (<xref linkend="sect_CID_12280" xrefstyle="select: labelnumber quotedtitle nopage"/> and <xref linkend="sect_CID_12281" xrefstyle="select: labelnumber quotedtitle nopage"/>).</para>
                <para xml:id="para_10f19fab-0d67-4f77-ab32-c0916077a33c">The implicit finding site inherited from <xref linkend="sect_TID_5222" xrefstyle="select: labelnumber quotedtitle nopage"/> can be made explicit by using the same finding site concept in the Target Site (the measurement concept modifier), rather than a term from <xref linkend="sect_CID_12280" xrefstyle="select: labelnumber quotedtitle nopage"/>. This explicit post-coordination allows the use of one of the modifiers of <xref linkend="sect_CID_12281" xrefstyle="select: labelnumber quotedtitle nopage"/> to that finding site, as the Target Site Modifier requires an explicit Target Site in the measurement structure (<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/> Rows 5 and 7). In fact, any child concept of the finding site in the SNOMED hierarchy may be used as the measurement Target Site.</para>
            <para xml:id="para_7011bfa1-8776-4fdd-81ae-67c5481a87d5">The finding or target site may be identified by a concept from the SNOMED "clinical finding" or "morphological anomaly" hierarchies (e.g.,
                <link xl:href="http://snomed.info/id/70142008" xl:show="new">(70142008, SCT, "Atrial Septal defect")</link>, or
                <link xl:href="http://snomed.info/id/41699000" xl:show="new">(41699000, SCT, "Effusion")</link>,
                rather than the "anatomical structure" hierarchy. In this case, the meaning is inferred as "the anatomic location of the clinical finding or morphological anomaly, within the constraints of other implicit or explicit post-coordinated finding site concepts."</para>
            <note>
                    <para xml:id="para_a4098364-61e2-4812-8078-11fd5acae9ae">Thus when <xref linkend="sect_TID_5221" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 14 invokes <xref linkend="sect_TID_5222" xrefstyle="select: labelnumber quotedtitle nopage"/> with the section finding site concept <link xl:href="http://snomed.info/id/76848001" xl:show="new">(76848001, SCT, "Pericardium")</link>, and <xref linkend="sect_TID_5223" xrefstyle="select: labelnumber quotedtitle nopage"/> Row 1 applies the target site <link xl:href="http://snomed.info/id/41699000" xl:show="new">(41699000, SCT, "Effusion")</link>, the effective finding site is "pericardial effusion".</para>
                </note>
                <table frame="box" label="TID 5223" rules="all" xml:id="table_TID_5223_Parameters">
                    <caption>Parameters</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_919dd488-b2c2-4307-972a-32545d295517">Parameter Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_435f1876-5494-454e-bb2f-71c6a1f84f3d">Parameter Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_adcfca19-b8b5-4771-99c1-f265e418f03a">$Measurement</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c301a65-d120-49c5-bd12-0d2463d471e2">Coded term or Context Group for Concept Name of measurement</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72a09206-fead-4cc8-9c13-d3d58fd7ce7b">$Method</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f39e33f5-c0c0-4652-b951-b0b6340fa742">Value for Measurement Method</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <variablelist spacing="compact">
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Type:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_50d19262-bbd5-4591-a918-7ae0f3e49e95">
                                <emphasis role="bold">Extensible</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Order:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_7f41a038-2cb0-458e-bb53-c0cf04e85065">
                                <emphasis role="bold">Significant</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                    <varlistentry>
                        <term>
                            <emphasis role="bold">Root:</emphasis>
                        </term>
                        <listitem>
                            <para xml:id="para_39f81154-67d3-4a43-a1e8-6885ca051bfa">
                                <emphasis role="bold">No</emphasis>
                            </para>
                        </listitem>
                    </varlistentry>
                </variablelist>
                <table frame="box" label="TID 5223" rules="all" xml:id="table_TID_5223">
                    <caption>Pediatric, Fetal and Congenital Cardiac Ultrasound Measurement</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_28a65897-79d3-4469-a20f-b1006432301e"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_afd11dea-0d6a-4c33-904a-45f3d08a2608">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_62754de1-0d0c-4bb0-b7a7-e27ed6b17876">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cfb2b365-4eb0-4b8b-8f3c-9e058c69e877">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6d6c95f1-bd4c-49a8-84c6-58d1433e1662">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_225168e3-6b14-46cd-b530-90a0a3a1d496">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_447f2f87-5677-45c4-98c0-bd13d944d283">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a63592b1-5823-4805-b3ac-e1f9f636d7d2">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8e2f6d5-c0bb-409f-b3d8-cbdb7ea89e26">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_74a49917-c214-44e0-b101-1bacd359dbb3">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d707746c-e3ab-401b-bd35-457aa716c3cd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61382f08-723b-45b4-a30b-ab72ca6c5d09"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b2672712-2ba3-40d3-b2e5-63a30a8e6c4c"><emphasis role="bold"><emphasis role="strikethrough">INCLUDE</emphasis><emphasis role="underline">NUM</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f870e04-ae5c-401e-ad6d-b73c216e0c47"><emphasis role="bold"><emphasis role="strikethrough">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis><emphasis role="underline">$Measurement</emphasis></emphasis>
                            </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6470af9-2ffb-4928-9452-f08fe271da8d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb81b3cc-9494-469b-8664-149b13577797">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c9d94c13-5750-4e52-940e-cb9da7c27b3e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2e6fdfbe-6632-4b4d-89ba-a75c1dbe1926"><emphasis role="bold"><emphasis role="strikethrough">$Measurement = $Measurement</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Method = $Method</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSite = B<xref linkend="sect_CID_12280" xrefstyle="select: labelnumber quotedtitle"/></emphasis></emphasis>
                            </para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$TargetSiteMod = B<xref linkend="sect_CID_12281" xrefstyle="select: labelnumber quotedtitle"/>
                                    </emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="strikethrough">$Derivation = D<xref linkend="sect_CID_3838" xrefstyle="select: labelnumber quotedtitle"/></emphasis></emphasis>
                            </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1b</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">&gt;</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">INCLUDE</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">D<xref linkend="sect_TID_30n" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">M</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0696df3e-f2e6-4605-acf3-e8e65feee16e"><emphasis role="bold"><emphasis role="underline">$Method = $Method</emphasis></emphasis></para>
                                <para xml:id="para_56add2b4-c933-4c67-a357-77f55c86b9d7"><emphasis role="bold"><emphasis role="underline">$TargetSite = B<xref linkend="sect_CID_12280" xrefstyle="select: labelnumber quotedtitle"/>
                                    </emphasis></emphasis></para>
                                <para xml:id="para_879f0f30-7a3b-4b96-854c-6bc936722cfa"><emphasis role="bold"><emphasis role="underline">$TargetSiteMod = B<xref linkend="sect_CID_12281" xrefstyle="select: labelnumber quotedtitle"/></emphasis></emphasis>
                            </para>
                                <para xml:id="para_ab869767-336e-4f95-814d-b2622f7eaba9"><emphasis role="bold"><emphasis role="underline">$Derivation = D<xref linkend="sect_CID_3838" xrefstyle="select: labelnumber quotedtitle"/></emphasis></emphasis>
                            </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_359afe96-a933-4b4a-923d-45a6f6221801">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93ecbb37-def1-4062-84b6-a921c6eea282">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93f20451-2427-4737-b314-6edf871ca181">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0206f248-5445-471f-863e-e9b5eeac469f">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61839a88-9536-4cf7-b327-6c2bfa68d120">EV <link linkend="DCM_121425" xrefstyle="select: nopage">(121425, DCM, "Index")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c9e0d39b-a63e-4f55-8331-da06fc06da32">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f017999c-0310-4768-9957-1b9613898bf7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_acb9b62c-9150-40dc-900d-a7ebbe88697a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1289e45e-2e36-4d5a-955b-82de1ed82daf">D<xref linkend="sect_CID_3455" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bd00ad37-e4a8-4ddb-aeba-a739c38d7d4f">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_575d1e88-96fb-47ca-a62e-fa0cdfbdaa82">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dede8546-b508-45f7-9415-b02f153254ff">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_83c5fe47-91c9-4d5b-b1bf-3f1a624c3715">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1fb62083-abb4-4c69-a262-d0b9080e456c">EV <link xl:href="http://snomed.info/id/260674002" xl:show="new">(260674002, SCT, "Flow Direction")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06c85ee0-95bc-4c3c-9ee9-64a835cf8ec9">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_25da9346-412a-4060-85b6-2e396d61aaa1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8adfb5f9-b184-4bad-b3b3-1b96b54f1afd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cd60720a-2d66-4b07-a3a7-b746592c2f31">B<xref linkend="sect_CID_12221" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0a74d67-cd2f-47b9-b017-dd2e222aedda">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af77f01f-606a-41f3-8bc9-578615daac03">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_47c15e4c-7326-4f1f-85c9-d35bbdf39017">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ce697f99-4e1c-4b80-ba99-e248aa758aba">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_02f0083c-ad35-4896-8b9f-08f1f0b1d198">EV <link xl:href="http://snomed.info/id/272517003" xl:show="new">(272517003, SCT, "Respiratory Cycle Point")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_389b9fb2-ed16-4619-9b9a-c732de0443e8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb34897d-ff01-4812-b178-b60a2edd6d57">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8960ee50-e3b8-43a9-bb58-a8b71e1dd0d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e28be10-8a1c-4246-945f-0325324646f5">D<xref linkend="sect_CID_12234" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb9b0a5c-1600-4fb6-bc34-0dfbfb93dd95">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5e36beb5-b837-4fbb-9332-f89373cde91c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f76c3b63-0eb2-4daf-9beb-04e5aef40f6b">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3fe487cf-e0a1-4470-be05-67fb70a1c290">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40876830-5d6b-47f3-9f9e-4a5c396d0957">EV <link xl:href="http://snomed.info/id/272518008" xl:show="new">(272518008, SCT, "Cardiac Cycle Point")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90eec3cb-7c44-4d37-b7d7-5778d116742d">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e76dab2d-81ce-40ec-9ad1-4d5d07c1febd">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64dfecea-6e7f-4875-8563-2ae60f900bb6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f973333-707d-4528-87fe-ab6a2d5781db">D<xref linkend="sect_CID_12233" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_395fe98e-c7b9-4b48-9c4f-bb9a74f62c98">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cbff028-93d8-4e18-a865-f50d8cb48753">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8558c3ad-37a3-4b86-badb-cbd03ea2452d">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_095e5a78-2072-4073-9426-5e144b954392">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61c92636-bde3-4c4f-b1f6-cb0ffd6fe737">EV <link xl:href="http://snomed.info/id/399264008" xl:show="new">(399264008, SCT, "Image Mode")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85eaa955-b4b4-47e4-82d7-dfc2b06bcd03">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_90666924-6a98-41d8-8000-855ade8ffa06">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51748acc-6a0b-4a64-8f49-d1ce75c252de"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_92f8d579-0c60-47f3-94c6-81bb58ed2d0b">D<xref linkend="sect_CID_12224" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_40a34448-8d3c-4c2f-9cdf-2bb4fa6ad13b">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17d66269-2a38-409e-9d29-7e0da7cfd5ec">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_440f67cd-fa5b-4e24-9082-9461ea1868ce">HAS ACQ CONTEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa1d84f7-6de8-44f2-8e25-0aae7f6841be">CODE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ead363ec-ed8e-48cd-98e8-f83567f37995">EV <link linkend="DCM_111031" xrefstyle="select: nopage">(111031, DCM, "Image View")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_058b16ef-2d34-48a9-b179-a4a1d2c91675">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c1d7ecc7-6143-4f34-a70e-adec281d2200">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9236ee98-dcd4-485e-a0f5-5e16282d3128"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_304fa70b-3a9a-4625-b4aa-1fec3c7b8437">B<xref linkend="sect_CID_12226" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_a2de065d-4965-4a80-a3bf-5d35b2c53b23">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69bb766a-393d-4b46-acf6-f066fbfdd8d0">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d5640c7-dd9a-40ed-97b7-7c6a7c6dd998">For an index type of measurement, the concept name of this Row 1 will still be the original measurement concept name; it is Row 2 that gives the indication that Row 1 is actually an index type of measurement. When this happens, the measurement value of Row 1 should be a value after being indexed and the measurement unit of Row 1 should be an index type of unit.</para>
                                <para xml:id="para_16523169-30ce-4736-8dd0-070a5696bbf4">For example, to insert a "Stroke Volume Index" measurement to this SR object, the concept name of Row 1 will be "Stroke Volume", its numerical value will be the calculation result of "Stroke Volume /BSA" and its units are "ml/cm2".</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5e3d1c0-7375-4ee7-8a14-d414f2ef6a0b">Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ccdfbd3-a687-4bff-809d-5bd022bbaaf8">When this row is available, the Row 1 is an index calculation of the object.</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged, an example of a correct invocation of TID 300 that is not followed by implicit inclusion of child rows of the invoked template container:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID 1501" status="3" xml:id="sect_TID_1501">
                <title>Measurement and Qualitative Evaluation Group</title>
                <table frame="box" label="TID 1501" rules="all" xml:id="table_TID_1501">
                    <caption>Measurement and Qualitative Evaluation Group</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6cf3eeee-bde3-41f2-9cd2-d2a7c2fd15de"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a753304a-333e-44a2-b1de-6a357d827b35">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9b361704-3515-44f8-bc8d-8b4c7bbd3bd6">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3f88f263-0608-4fda-9eb2-629f8f00ab90">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_472206d9-066c-4c71-9bbd-2114d729f75b">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8720acfb-54df-451c-b098-dc55f146f6bd">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_789f5c1b-14da-47e9-8b2d-91afa2c9f6ce">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e618c06c-2ed8-4cc8-86d8-570049b0290b">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_50c97dbc-38b3-4780-8666-e80d0e960f39">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e553294-3b91-4308-9dd5-cab5993fc271">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c32e330b-8290-4360-a024-2bf2bd867a5a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7999f1a1-e780-4573-be47-540a1718b75b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1b3f4a25-408c-4c4d-8be6-1d600c149895">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cc549fc-754a-4eaa-a2d3-6291e8750353">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fcc4ffad-bb0d-49ad-b7fa-967199743ff2">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b73d3ca3-05ba-48ac-9eab-b2f0e7f0df78">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d35f0bc7-9294-4136-b82c-6d7c23f702b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_03be1fcd-9618-44fa-a630-706e645c6bf3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff2f07db-7c32-467f-bb12-fe971b409b38">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6a520a91-4690-4471-b566-ea4eb14543a2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8115766b-050b-4d5d-852f-e4e581690f79"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f646f123-7cea-4bca-a381-029fde6fc59a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3542061-a8ad-4a26-a63f-ca9784b061bd"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ddaa1d32-2d8c-4385-ba25-45d27dfc1f25"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3ae01147-d156-41b1-b8cf-80bae1934d65"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_023d7269-c7d0-45a6-a134-2c3f9b57a170"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32313350-d035-44c7-a8fc-f965aee4cbf2"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e488327-ccf3-46ab-a700-fb2b68c49f6f">9d</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe676738-d128-41c5-8c32-be3078edcce7">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad0f94dd-d2f6-499b-bcb5-49ee077ea2f0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20588b02-b2b9-45f8-93e8-103c4bcec4dd">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9c14218d-ff9a-455a-92c9-fd8ec166d83a">EV <link linkend="DCM_130401" xrefstyle="select: nopage">(130401, DCM, "Visual explanation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_03043cfc-538a-4d2e-8216-4fee57fd0024">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80484d05-5972-495c-9601-26aa6843bbfe">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d097d9ee-c976-4361-9f72-240a2c5405bc"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3edc3b48-a8b6-46fb-a053-470c6feadc10"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d5a36cf-23f5-4c7d-a5d7-7ee4322f1b03">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e58ce1bd-d0ac-448d-9b93-01f903241340">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6177297b-681a-4e6b-b8c7-2881cd7e0ba7">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_262cd8dd-5c62-46dc-9228-61b78178bd26">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4f382802-3d6d-4d33-a37d-5208d882708c">D<xref linkend="sect_TID_300" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8e58ba2c-c810-4780-b9f5-3f7391d17037">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_680211e9-9f16-46b4-830e-f947d05bb711">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5faad4f-a65b-4bee-8c06-4b271b8f4559"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f39a1c62-ce64-4943-a3b6-165b144f07e7">$Measurement = $Measurement</para>
                                <para xml:id="para_793d2241-8a62-4744-babe-23d6f78f652a">$Units = $Units</para>
                                <para xml:id="para_92e6f6ab-8253-4199-b880-698e0b3764e8">$ModType = $ModType</para>
                                <para xml:id="para_51b7a3f0-cef1-41be-ac3c-7328c2a23cf5">$ModValue = $ModValue</para>
                                <para xml:id="para_0195d2d8-4704-46aa-847f-888bf183efef">$Method = $Method</para>
                                <para xml:id="para_a598a4cf-16b8-41e9-8da5-e45fee215ba8">$Derivation = $Derivation</para>
                                <para xml:id="para_a520ab94-54af-48bc-94ad-1c0c012b35a8">$TargetSite = $TargetSite</para>
                                <para xml:id="para_9136f165-0728-41a9-846b-3c467174949e">$TargetSiteMod = $TargetSiteMod</para>
                                <para xml:id="para_618a925c-b9aa-4e68-9be9-69035614020c">$Equation = $Equation</para>
                                <para xml:id="para_d2c54ff0-c4f5-4375-8838-fde39cb9232d">$ImagePurpose = $ImagePurpose</para>
                                <para xml:id="para_5db5f2d5-f0c9-48b9-8259-d2c2b7f6d44c">$WavePurpose = $WavePurpose</para>
                                <para xml:id="para_d16f9c46-d989-48e8-8655-1fc0d42caced">$RefAuthority = $RefAuthority</para>
                                <para xml:id="para_874803a4-4c0f-45a0-b22b-6ee636108a9d">$RangeAuthority = $RangeAuthority</para>
                                <para xml:id="para_5b19ea79-97de-4f5e-87c4-8a04ddcc3740">$DerivationParameter = $DerivationParameter</para>
                                <para xml:id="para_9b9c9301-94db-4c83-af7d-b1da9193fccf">$DerivationParameterUnits = $DerivationParameterUnits</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe31cfd0-0ce4-4780-aaa7-eaec116a88fd">10b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7013753d-940e-4092-bc23-55abc268ff8d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_80f4174a-a81e-4fac-9333-06a8a1bddd77">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f8d549-5b2e-4bb3-87b6-7ef1760c3de4">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e144bb01-a068-450e-9a9f-68975304aa86">$ImagePurpose </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_790eb5d4-5524-4563-8523-19519e646139">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7510fc8c-fb42-4790-8675-ad9dd9748131">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a62bde1f-bd3e-4b39-94bc-af9912cea925"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        

        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged, hyperlink targets:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="6.2.4" status="3" xml:id="sect_6.2.4">
            <title>Post-coordinated Codes and Has Concept Modifier Relationship</title>
        </section>
        
        <section label="TID 310" status="3" xml:id="sect_TID_310">
            <title>Measurement Properties</title>
        </section>
        <section label="TID 315" status="3" xml:id="sect_TID_315">
            <title>Equation or Table</title>
        </section>
        <section label="TID 320" status="3" xml:id="sect_TID_320">
            <title>Image or Spatial Coordinates</title>
        </section>
        <section label="TID 321" status="3" xml:id="sect_TID_321">
            <title>Waveform or Temporal Coordinates</title>
        </section>
        <section label="TID 1000" status="3" xml:id="sect_TID_1000">
            <title>Quotation</title>
        </section>
        <section label="TID 4019" status="3" xml:id="sect_TID_4019">
            <title>Algorithm Identification</title>
        </section>
        <section label="TID 4108" status="3" xml:id="sect_TID_4108">
            <title>Tracking Identifier</title>
        </section>
        <section label="TID 5221" status="3" xml:id="sect_TID_5221">
            <title>Cardiac Ultrasound Pediatric Echo Measurement Section</title>
        </section>
        <section label="TID 5222" status="3" xml:id="sect_TID_5222">
            <title>Pediatric, Fetal and Congenital Cardiac Ultrasound Section</title>
        </section>
        
        <section label="CID 228" status="3" xml:id="sect_CID_228">
            <title>Equation or Table</title>
        </section>
        <section label="CID 244" status="3" xml:id="sect_CID_244">
            <title>Laterality</title>
        </section>
        <section label="CID 3838" status="3" xml:id="sect_CID_3838">
            <title>Diameter Derivation</title>
        </section>
        <section label="CID 3455" status="3" xml:id="sect_CID_3455">
            <title>Index Method</title>
        </section>
        <section label="CID 12002" status="3" xml:id="sect_CID_12002">
            <title>Ultrasound Protocol Stage Type</title>
        </section>
        <section label="CID 12221" status="3" xml:id="sect_CID_12221">
            <title>Flow Direction</title>
        </section>
        <section label="CID 12224" status="3" xml:id="sect_CID_12224">
            <title>Ultrasound Image Mode</title>
        </section>
        <section label="CID 12226" status="3" xml:id="sect_CID_12226">
            <title>Echocardiography Image View</title>
        </section>
        <section label="CID 12233" status="3" xml:id="sect_CID_12233">
            <title>Cardiac Phase</title>
        </section>
        <section label="CID 12234" status="3" xml:id="sect_CID_12234">
            <title>Respiration State</title>
        </section>
        <section label="CID 12236" status="3" xml:id="sect_CID_12236">
            <title>Echocardiography Anatomic Site</title>
        </section>
        <section label="CID 12237" status="3" xml:id="sect_CID_12237">
            <title>Echocardiography Anatomic Site Modifier</title>
        </section>
        <section label="CID 12280" status="3" xml:id="sect_CID_12280">
            <title>Cardiac Ultrasound Target Site</title>
        </section>
        <section label="CID 12281" status="3" xml:id="sect_CID_12281">
            <title>Cardiac Ultrasound Target Site Modifier</title>
        </section>
        
    </chapter>
</book>