<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2474</title>
    <subtitle>Add more standard color spaces</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/06/17</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Bart Diricx</para><para><link
                    xl:href="mailto:bart.diricx@barco.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/11/03</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2474</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add more standard color spaces</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.18</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>There is value in using standard color spaces with a wider gamut than others currently defined, such as Display-P3.</para>
                    <para>See also <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://en.wikipedia.org/wiki/DCI-P3">http://en.wikipedia.org/wiki/DCI-P3</link> for a discussion between the relationship of Display-P3 and DCI-P3 . </para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.3 and PS3.18 to add new reference as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="2" status="1" xml:id="chapter_2">
            <title>Normative References</title>
            <bibliography>
                <biblioentry xml:id="biblio_IEC61966-2.1">
                    <abbrev>IEC 61966-2.1</abbrev>
                    <author>
                        <orgname>IEC</orgname>
                    </author>
                    <date>1999</date>
                    <edition>Ed 1.0</edition>
                    <title>Multimedia systems and equipment - <foreignphrase xml:lang="en-GB">colour</foreignphrase> measurement and management - Part 2.1: <foreignphrase xml:lang="en-GB">colour</foreignphrase> management - Default RGB <foreignphrase xml:lang="en-GB">colour</foreignphrase> space - sRGB</title>
                </biblioentry>
                
                <biblioentry xml:id="biblio_ISO22028-2">
                    <abbrev>ISO 22028-2</abbrev>
                    <author>
                        <orgname>ISO</orgname>
                    </author>
                    <date>2013</date>
                    <title>Photography and graphic technology - Extended colour encodings for digital image storage, manipulation and interchange - Part 2: Reference output medium metric RGB colour image encoding (ROMM RGB)</title>
                    <bibliosource>
                        <link xl:href="http://www.iso.org/iso/catalogue_detail.htm?csnumber=56591"/>
                    </bibliosource>
                </biblioentry>
                
                
                <biblioentry xml:id="biblio_AdobeRGB">
                    <abbrev>Adobe RGB</abbrev>
                    <author>
                        <orgname>Adobe Systems Incorporated</orgname>
                    </author>
                    <date>1998</date>
                    <edition>2005-05</edition>
                    <title>Adobe RGB (1998) Color Image Encoding</title>
                    <bibliosource>
                        <link xl:href="http://www.adobe.com/digitalimag/pdfs/AdobeRGB1998.pdf"/>
                    </bibliosource>
                </biblioentry>
                
                <biblioentry xml:id="biblio_Display-P3">
                    <abbrev>Display-P3</abbrev>
                    <author>
                        <orgname><emphasis role="bold"><emphasis role="underline">Apple, Inc</emphasis></emphasis></orgname>
                    </author>
                    <title><emphasis role="bold"><emphasis role="underline">Display P3 Color Encoding</emphasis></emphasis></title>
                    <bibliosource>
                        <link xl:href="http://www.color.org/chardata/rgb/DisplayP3.xalter"/>
                    </bibliosource>
                </biblioentry>
                
                <biblioentry xml:id="biblio_SMPTE_RP431-2">
                    <abbrev>SMPTE RP 431-2:2011</abbrev>
                    <author>
                        <orgname><emphasis role="bold"><emphasis role="underline">Society of Motion Picture and Television Engineers (SMPTE)</emphasis></emphasis></orgname>
                    </author>
                    <date><emphasis role="bold"><emphasis role="underline">2011</emphasis></emphasis></date>
                    <title><emphasis role="bold"><emphasis role="underline">D-Cinema Quality — Reference Projector and Environment</emphasis></emphasis></title>
                    <bibliosource>
                        <link xl:href="http://pub.smpte.org/latest/rp431-2/rp0431-2-2011.pdf"/>
                    </bibliosource>
                </biblioentry>
                
                <biblioentry xml:id="biblio_DCI_DCSS">
                    <abbrev>DCI DCSS</abbrev>
                    <author>
                        <orgname><emphasis role="bold"><emphasis role="underline">Digital Cinema Initiatives, LLC. (DCI)</emphasis></emphasis></orgname>
                    </author>
                    <date><emphasis role="bold"><emphasis role="underline">May 29, 2024</emphasis></emphasis></date>
                    <title><emphasis role="bold"><emphasis role="underline">Digital Cinema System Specification</emphasis></emphasis></title>
                    <bibliosource>
                        <link xl:href="http://www.dcimovies.com/dci-specification"/>
                    </bibliosource>
                </biblioentry>
                
            </bibliography>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="C.11.15" status="3" xml:id="sect_C.11.15">
            <title>ICC Profile Module</title>
            <table frame="box" label="C.11.15-1" rules="all" xml:id="table_C.11.15-1">
                <caption>ICC Profile Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90346347-e09c-448d-9916-87d1bd717d75">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d490a61-6c15-411d-9c4c-43dce48b3dad">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a81f0f38-9181-4941-9de5-043ef12a8641">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_00264f91-88e9-42d6-897c-892b8795319f">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f22402d6-60da-4d69-bbf6-bbf52394226c">ICC Profile</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2418883f-0217-4455-a344-9f2839cbc46c">(0028,2000)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fe8cd1e8-c8ef-44a8-854e-70856a64fb9e">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_12b9fd75-7a35-4e5f-b618-cd144da335c8">An ICC Profile encoding the transformation of device-dependent color stored pixel values into PCS-Values.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0185de45-dfed-4a2a-ba32-f9beb18370d3">Color Space</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c3bcec7-0c9b-4629-a5ee-68035fd33038">(0028,2002)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8648794a-f2e1-460b-965e-b0250838e86f">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2992c9a5-8626-422f-ab8f-9141b1ab4542">A label that identifies the well-known color space of the image. Shall be consistent with any ICC Profile (0028,2000) that is also present.</para>
                            <para xml:id="para_d176f5ca-935a-43b0-bd02-445583af1240">See <xref linkend="sect_C.11.15.1.2" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="C.11.15.1" status="4" xml:id="sect_C.11.15.1">
                <title>ICC Profile Module Attribute Descriptions</title>
                <section label="C.11.15.1.1" status="5" xml:id="sect_C.11.15.1.1">
                    <title>ICC Profile</title>
                    <para xml:id="para_8a8c68e0-ce88-45f5-a4aa-e1ac5225154f">...</para>
                </section>
                <section label="C.11.15.1.2" status="5" xml:id="sect_C.11.15.1.2">
                    <title>Color Space</title>
                    <para xml:id="para_35befd33-cb29-449e-ae3e-592ad260c027">The Color Space Attribute provides a label that identifies the color space by name, when the ICC Profile (0028, 2000) (if present) describes a well-known color space.</para>
                    <variablelist>
                        <title>Defined Terms:</title>
                        <varlistentry>
                            <term>SRGB</term>
                            <listitem>
                                <para xml:id="para_3f6732fc-fac0-4ce3-9da1-ae18284546a1">ICC Profile (0028,2000) defines sRGB color space <xref linkend="biblio_IEC61966-2.1"/>
                                </para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>ADOBERGB</term>
                            <listitem>
                                <para xml:id="para_52601004-9e78-42c6-b170-416395886e41">ICC Profile (0028,2000) defines Adobe RGB color space <xref linkend="biblio_AdobeRGB"/>
                                </para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>ROMMRGB</term>
                            <listitem>
                                <para xml:id="para_24ff4566-351f-4afc-a6b4-5c56e02b0ba4">ICC Profile (0028,2000) defines ROMM RGB color space <xref linkend="biblio_ISO22028-2"/>
                                </para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term><emphasis role="underline">DISPLAYP3</emphasis></term>
                            <listitem>
                                <para><emphasis role="bold"><emphasis role="underline">ICC Profile (0028,2000) defines Display-P3 color space <xref linkend="biblio_Display-P3"/></emphasis></emphasis>
                                </para>
                            </listitem>
                        </varlistentry>
                    </variablelist>
                    <note>
                        <para><emphasis role="bold"><emphasis role="underline">The Display-P3 color space is similar to but not the same as DCI-P3 color space (defined in <xref linkend="biblio_SMPTE_RP431-2"/>). Display-P3 uses the sRGB transfer function whereas DCI-P3 uses a gamma of 2.6 for the transfer function, and a different white point (D65 vs D63). The reason for using Display-P3 in DICOM rather than DCI-P3 is because web browser technology has native support for it, whereas DCI-P3 was designed for digital cinema applications <xref linkend="biblio_DCI_DCSS"/>.</emphasis></emphasis></para>
                    </note>
                </section>
            </section>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.18 as follows (changes to existing text
                        are bold and <emphasis role="bold"><emphasis role="underline"
                            >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                                ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
                        removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="8.3.5.1" status="4" xml:id="sect_8.3.5.1">
                    <title>Query Parameters for Rendered Resources</title>
                    <para xml:id="para_e69b4f13-c6f8-47ad-aa37-f3f963062877">...</para>
                    <table frame="box" label="8.3.5-1" rules="all" xml:id="table_8.3.5-1">
                        <caption>Retrieve Rendered Query Parameters</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_0a379a6e-dbae-4598-ac47-2158096258e8">Key</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2bfbffee-126d-4ac6-8a76-0b8bf868fc29">Values</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d07bddef-c894-4100-9a71-a6bdd3ff4913">Target Resource Category</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9413ce8c-4111-43f4-872e-ef1c05176b2b">Section</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <programlisting>...</programlisting>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <programlisting/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_305191df-f35a-4bf0-86fe-332b42c24663"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b1bcc95f-c0a0-4961-8d94-b6ecd0558fde"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <programlisting>iccprofile</programlisting>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <programlisting>"no", "yes", "srgb", "adobergb"<emphasis role="bold"><emphasis role="strikethrough"> or</emphasis><emphasis role="underline">,</emphasis></emphasis> "rommrgb"<emphasis role="bold"><emphasis role="underline">, or "displayp3"</emphasis></emphasis></programlisting>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5cbbf2a5-6658-49a2-abc9-ced2836ba2bd">Image (single or multi-frame) or Video</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99067773-f633-490d-ae9d-f660abb0d9ac">
                                        <xref linkend="sect_8.3.5.1.5" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <section label="8.3.5.1.5" status="5" xml:id="sect_8.3.5.1.5">
                        <title>ICC Profile</title>
                        <para xml:id="para_981ce263-356e-4bf6-9102-ee93f5e29cc8">The "iccprofile" parameter specifies the color characteristics of, and inclusion of an ICC Profile in, the rendered images. It has the following syntax:</para>
                        <programlisting>%s"iccprofile=" 1#( %s"no" / %s"yes" / %s"srgb" / %s"adobergb" / %s"rommrgb"<emphasis role="bold"><emphasis role="underline"> / %s"displayp3"</emphasis></emphasis> )</programlisting>
                        <para xml:id="para_aec52e2a-ac76-4c2b-bdcb-872e9f165e8a">Where</para>
                        <informaltable frame="void" rules="none">
                            <tbody>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_a6b68a12-85ce-4777-91d5-00d83b5a1bef">"no"</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b89597f5-4fb9-4f3d-8273-a86ab343871f">indicates that no ICC profile shall be present in the rendered image in the response.</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_7a27bdbc-8552-4547-9f51-0f81b9539908">"yes"</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_81244bcc-808e-499c-83d1-5a6b777d09a8">indicates that an ICC profile shall be present in the rendered image in the response, describing its color characteristics, if the Media Type supports embedded ICC Profiles.</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1d4dd703-0c3e-4d5c-a0c9-6c70087ccacc">"srgb"</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_fede96af-807f-44cd-b63a-e42679e9b2f7">indicates that an sRGB ICC profile shall be present in the image, if the Media Type supports embedded ICC Profiles, and that the pixels of the rendered image in the response shall be transformed from their original color space and be encoded in the sRGB color space [IEC 61966-2.1].</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_b93b19da-a742-4a2a-a9ff-0bc43d8bb0e5">"adobergb"</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_5c617bc1-7d0e-4bf4-bcb2-e4b7a00ecd89">indicates that an Adobe RGB ICC profile shall be present in the image, if the Media Type supports embedded ICC Profiles, and that the pixels of the rendered image in the response shall be transformed from their original color space and be encoded in the Adobe RGB color space [Adobe RGB].</para>
                                    </td>
                                </tr>
                                <tr valign="top">
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_1dd6652d-5069-4fbb-bb7b-cee307dd456b">"rommrgb"</para>
                                    </td>
                                    <td align="left" colspan="1" rowspan="1">
                                        <para xml:id="para_d973222c-5ed8-4797-b3e5-be6f2fff55fa">indicates that a ROMM RGB ICC profile shall be present in the image, if the Media Type supports embedded ICC Profiles, and that the pixels of the rendered image in the response shall be transformed from their original color space and encoded in the ROMM RGB color space [ISO 22028-2].</para>
                                    </td>
                                </tr>
                        <tr>
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">"displayp3"</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">indicates that a Display-P3 ICC profile shall be present in the image, if the Media Type supports embedded ICC Profiles, and that the pixels of the rendered image in the response shall be transformed from their original color space and encoded in the Display-P3 color space <xref linkend="biblio_Display-P3"/></emphasis></emphasis></para>
                            </td>
                        </tr>
                            </tbody>
                        </informaltable>
                        <para xml:id="para_2675b469-4819-4689-ae1f-5a1615162efd">When this parameter is not present:</para>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_c83707af-f676-4de0-8c2e-11d7d0047a98">an ICC profile may or may not be present in the image in the response;</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_99b7bb95-2ed3-4662-8033-66c76bad02b7">the color characteristics of the image in the response may or may not be consistent with any DICOM ICC Profile (0028,2000) Attribute in the metadata.</para>
                            </listitem>
                        </itemizedlist>
                        <para xml:id="para_c00be647-241d-4baa-b1c9-10dc3fde8f69">The ICC Profile in the image in the response shall be:</para>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_de4a88a4-45fa-4e31-bc44-edcae0b3ac3e">the ICC profile of the color space specified explicitly by the parameter,</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_e28b299b-a9f0-4fe5-bb56-58b1983f055e">otherwise, the ICC profile encoded in the source DICOM ICC Profile (0028,2000) Attribute, if any, appropriate to the selected frame,</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_afeb924b-85a8-4350-8fbf-f32777c3566c">otherwise, the ICC profile, if any, embedded in the stored compressed representation of the selected frame,</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_9b1baa7d-3306-4660-8ba2-3affeedca70f">otherwise, at the discretion of the origin server, the ICC profile of a well-known color space listed in <olink targetdoc="PS3.3" targetptr="sect_C.11.15.1.2" xrefstyle="template:Section %n “%t” in PS3.3"/> that is appropriate to the type and source of the image.</para>
                            </listitem>
                        </itemizedlist>
                        <para xml:id="para_81b276c6-c572-4c90-a902-8d3a9948c46c">If the Media Type does not support embedded ICC Profiles:</para>
                        <itemizedlist>
                            <listitem>
                                <para xml:id="para_2dec5093-cdb2-4cc5-9a39-83cdb4c15da9">a 400 Bad Request error shall be returned if the parameter value is other than "no"</para>
                            </listitem>
                        </itemizedlist>
                        <note>
                            <orderedlist>
                                <listitem>
                                    <para xml:id="para_dac082b7-1879-41d6-b246-ccd5e3918c10">This parameter allows ICC profile information to be present in the image in the response so that the user agent can make use of it for local color management (e.g., an ICC profile capable browser can apply the profile when displaying the rendered image in the response).</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_02616218-8143-49c6-a362-deb15532fd37">This parameter provides a limited mechanism for requesting that the origin server perform some color management. It provides the names of well-known color spaces for the rendered image in the response. It does not provide a mechanism to supply an arbitrary ICC profile, such as the calibration profile of a display, so it does not absolve the user agent from the need to handle its own color calibration and color management.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_80507148-4fc1-41e8-93ca-5151be0ded0f">ICC profiles can theoretically be large relative to the compressed pixel data of a single frame, so the user agent may specify a parameter value of "no", retrieve the DICOM ICC Profile (0028,2000) Attribute value(s) that apply to multiple frames from the metadata, and combine these itself.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_03885bab-2716-480e-a0d2-4f872e0a88d9">ICC profiles are embedded in rendered images of Media Type image/jpeg as one or more chunks in APP2 marker segments with an identifier of "ICC_PROFILE", as defined in Annex B of <xref linkend="biblio_ISOIEC15076-1"/>.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_07511abf-7cfc-40ba-b202-54c73d3a149f">ICC profiles are embedded in rendered images of Media Type image/jp2 either as JP2 Restricted or JPX Full profiles according to <xref linkend="biblio_ISOIEC15444-1"/> and <xref linkend="biblio_ISOIEC15444-2"/>, respectively; rendered images in the response are not subject to the prohibition against inclusion of a JP2 box in JPEG 2000 compressed data streams in DICOM images.</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_85387a42-c7d3-4053-8784-d4ec696d652e">ICC profiles are embedded in rendered images of Media Type image/png in an iCCP chunk, as defined in <xref linkend="biblio_ISO15948"/>.</para>
                                </listitem>
                            </orderedlist>
                        </note>
                    </section>
                </section>
</chapter>
</book>