<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2458</title>
    <subtitle>De-identification of Group 0004 data elements and DICOMDIR</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>March 2025 Voting Packet</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2025/01/21</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Laura Kelly Opsahl-Ong</para><para><link
                    xl:href="mailto:lopsahlong@deloitte.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/09/18</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2458</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: De-identification of Group 0004 data elements and DICOMDIR</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The DICOMDIR File can be recreated from the de-identified files or itself be de-identified.</para>
                    <para>Group 0004 data elements should not occur in other instances than the DICOMDIR File so always need to be removed if encountered.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.15 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
      
        <section label="3" status="1" xml:id="chapter_3">
            <title>Definitions</title>
            <para/>
            <glossary>
        <glossdiv label="3.12" status="2" xml:id="sect_3.12">
            <title><emphasis role="underline">DICOM Media Storage and File Format Definitions</emphasis></title>
            <para><emphasis role="bold"><emphasis role="underline">This Part of the Standard makes use of the following terms defined in <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>:</emphasis></emphasis></para>
            <glossentry xml:id="glossentry_DICOMDIR" xreflabel="DICOMDIR File">
                        <glossterm><emphasis role="bold"><emphasis role="underline">DICOMDIR File</emphasis></emphasis></glossterm>
                        <glossdef>
                            <emphasis role="bold"><emphasis role="underline">
                                    <para>
                                        <olink targetdoc="PS3.10" targetptr="glossentry_DICOMDIR" xrefstyle="template:See %t in %o"/>.</para>
                                </emphasis></emphasis>
                        </glossdef>
                    </glossentry>
            <glossentry xml:id="glossentry_File-set" xreflabel="File-set">
                        <glossterm><emphasis role="bold"><emphasis role="underline">File-set</emphasis></emphasis></glossterm>
                        <glossdef>
                            <emphasis role="bold"><emphasis role="underline">
                                    <para>
                                        <olink targetdoc="PS3.10" targetptr="glossentry_File-set" xrefstyle="template:See %t in %o"/>.</para>
                                </emphasis></emphasis>
                        </glossdef>
                    </glossentry>
        </glossdiv>
            </glossary>
        </section>
        
        <section label="E.1" status="2" xml:id="sect_E.1">
            <title>Application Level Confidentiality Profile</title>
            <para xml:id="para_bf0b34bf-7b49-4630-a893-33aa27bedf95">...</para>
            <section label="E.1.1" status="3" xml:id="sect_E.1.1">
                <title>De-identifier</title>
                <para xml:id="para_4611a9c4-5846-41ea-8015-87e4bac046f0">.:</para>
                <orderedlist numeration="arabic">
                    <listitem>
                        <para xml:id="para_a5c1cb67-16cf-4947-ab7f-252cc9a18562">...</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_daa1954b-9af4-4bad-aa35-41690a97fc7f">...</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_08a36063-841b-4499-9a4e-8501cc83acae">...</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_1c3d937e-b42b-4cd7-80db-092f09622605">...</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_bf62b269-f6b0-4598-ab70-36dec5b54ea5">...</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_7a8255cd-d599-4fca-9414-99cca6ed47a7">...</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_41258edc-da3a-43bb-ae04-3734051a876b">If the Dataset being de-identified is being stored within a DICOM File, then the File Meta Information including the 128 byte preamble, if present, shall be replaced with a description of the de-identifying application. Otherwise, there is a risk that identity information may leak through unmodified File Meta Information or preamble. See <olink targetdoc="PS3.10" targetptr="PS3.10" xrefstyle="select: labelnumber"/>. This includes information regarding Application Entity Titles, Presentation Addresses, implementation information, and private information.</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_3f2a2e5f-92da-442a-847e-232d77a14d9d">If the Dataset being de-identified is being communicated by DICOM Real-Time Video, then the File Meta Information including the 128 byte preamble, if present, shall be replaced with a description of the de-identifying application. Otherwise, there is a risk that identity information may leak through unmodified File Meta Information or preamble. See <olink targetdoc="PS3.22" targetptr="PS3.22" xrefstyle="select: labelnumber"/>. This includes information regarding Application Entity Titles, Presentation Addresses, implementation information, and private information.</para>
                    </listitem>
                    <listitem>
                        <para><emphasis role="bold"><emphasis role="underline">All group 0004H Data Elements shall be removed from any instance other than a DICOMDIR file. If a DICOMDIR File is required, it shall either be created from the de-identified files it references, or an existing DICOMDIR File shall be de-identifed according to this Profile. Any existing non-de-identified DICOMDIR File shall be removed from the File-set.</emphasis></emphasis></para>
                    </listitem>
                </orderedlist>
            </section>
        </section>
        
</chapter>
</book>