<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2456</title>
    <subtitle>General handling of known safe private data elements within private sequences</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/11/15</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Laura Kelly Opsahl-Ong</para><para><link xl:href="mailto:lopsahlong@deloitte.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/08/21</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2456</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: General handling of known safe private data elements within private sequences</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>It is not clear how to classify private data elements that are sequences that may contain a mixture of known safe
                        and not safe content within sequence item datasets.</para>
                    <para>A rule is added that describes how to handle this situation.</para>
                    <para><emphasis role="italic">[Ed.Note: Reconsider consistency of use of Attribute vs. Data Element throughout Annex E.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.15 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="E.1.1" status="3" xml:id="sect_E.1.1">
            <title>De-identifier</title>
            <para>...</para>
            <para xml:id="para_3980cc0a-c52c-4abd-bb2d-5598fedad2ea">The Attributes listed in Table E.1-1<!--<xref linkend="table_E.1-1" xrefstyle="select: label"/>--> for each Profile or Option are contained in Standard IODs, or may be contained in Standard Extended IODs. An implementation claiming conformance to the Basic Application Level Confidentiality Profile as a de-identifier shall protect or retain all instances of the Attributes listed in <xref linkend="table_E.1-1" xrefstyle="select: label"/>, whether contained in the main dataset or embedded in an Item of a Sequence of Items. The action codes in <xref linkend="table_E.1-1a" xrefstyle="select: label"/> are used in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
            
        </section>
        
<section label="E.3.10" status="3" xml:id="sect_E.3.10">
                <title>Retain Safe Private Option</title>

                <para xml:id="para_1d6b7025-554e-40c2-bafa-39c2daed3955">By definition, Private Attributes contain proprietary information, in many cases the nature of which is known only to the vendor and not publicly documented.</para>
                <para xml:id="para_fec0be3d-44f3-4c55-9471-1fcef67db8ae">However, some Private Attributes may be necessary for the desired application. For example, specific technique information such as CT helical span pitch, or pixel value transformation, such as PET SUV rescale factors, may only be available in Private Attributes since the information is either not defined in Standard Attributes, or was added to the DICOM Standard after the acquisition device was manufactured.</para>
                <para xml:id="para_bb1aaf5b-ab3d-4b05-8226-c7282cf98dc9">When this Option is specified in addition to the Basic Application Level Confidentiality Profile, Private Attributes that are known by the de-identifier to be safe from identity leakage shall be retained, together with the Private Creator IDs that are required to fully define the retained Private Attributes; all other Private Attributes shall be removed or processed in the element-specific manner recommended by Deidentification Action (0008,0307), if present within Private Data Element Characteristics Sequence (0008,0300) (see <olink targetdoc="PS3.3" targetptr="sect_C.12.1" xrefstyle="template:PS3.3 Section %n"/>).</para>
                <para xml:id="para_ae514a31-161a-421e-8d38-e06c466773af">Whether or not an Attribute is known to be safe may be determined by:</para>
                <itemizedlist>
                    <listitem>
                        <para xml:id="para_8621c63f-c569-423f-89d4-cc51d4c116cf">its presence in a block of Private Data Elements with a Value of "SAFE" in Block Identifying Information Status (0008,0303) or individually listed in Nonidentifying Private Elements (gggg,0004) (within Private Data Element Characteristics Sequence (0008,0300); see <olink targetdoc="PS3.3" targetptr="sect_C.12.1" xrefstyle="template:PS3.3 Section %n"/>)</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_87201ae4-9353-4f34-80ab-075d72a24cbf">its presence in <xref linkend="table_E.3.10-1" xrefstyle="select: label title"/>
                        </para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_0a191532-1817-4b6c-a5e0-c475e45b002c">documentation in the Conformance Statement</para>
                    </listitem>
                    <listitem>
                        <para xml:id="para_8a298f8e-99a5-4fbf-b728-2eb2b6b1bb09">some other means.</para>
                    </listitem>
                </itemizedlist>
                <para xml:id="para_0c838fa8-6930-4559-a492-67c204358848">When this Option is not specified, all Private Attributes shall be removed, as described in <xref linkend="table_E.1-1" xrefstyle="select: label"/>.</para>
            <para><emphasis role="bold"><emphasis role="underline">When an entire Sequence (SQ VR) Private Attribute is not known to always only contain safe content, whether that content consists of Standard Attributes or Private Attributes or a combination of both, then when the Retain Safe Private Option is used, any such Sequence Attribute shall be parsed in its entirety and each of the nested Attributes handled on its own merits, rather than removing the Sequence in its entirety without further consideration. Reviewing the content may be a sensible practice to apply even to nominally known safe Private Sequence Attributes.</emphasis></emphasis></para>
                <note>
                    <orderedlist>
                        <listitem>
                            <para xml:id="para_8348851c-c236-4e1d-820b-f2d693eb0857">A sample list of Private Attributes thought to be safe is provided here. Vendors do not guarantee them to be safe, and do not commit to sending them in any particular software version (including future products).</para>
                            <table frame="box" label="E.3.10-1" rules="all" xml:id="table_E.3.10-1">
                                <caption>Safe Private Attributes</caption>
                                <thead>
                                    <tr valign="top">
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c9eedc6-e981-424a-aaba-02338b7bd3a6">
                                                <emphasis role="bold">Data Element</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5ac89912-a4d0-467e-a5f6-79d86a4e4902">
                                                <emphasis role="bold">Private Creator</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_da5d42a9-8e1f-44f4-a6dd-f2eaa98a401b">
                                                <emphasis role="bold">VR</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_389182b9-579c-485e-9475-c8c57f0473f7">
                                                <emphasis role="bold">VM</emphasis>
                                            </para>
                                        </th>
                                        <th align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d4ede75b-b116-4bec-b6cb-7b3a548399c7">
                                                <emphasis role="bold">Meaning</emphasis>
                                            </para>
                                        </th>
                                    </tr>

                                </thead>
                                <tbody>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_537485c9-1a82-41df-b741-d97b9c43ef3f">(7053,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_28e7f6a9-847d-41ed-9bff-56107db816c1">Philips PET Private Group</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6280d14a-b7aa-4e3d-b0b2-09cb74644d15">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b5cc5e21-d534-42b5-ae19-3783745d0e98">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_38ce5923-8365-4d77-9c3b-63d87fad9c2a">SUV Factor - Multiplying Stored Pixel Values by Rescale Slope then this factor results in SUVbw in g/l</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cf0b21fc-9fc2-4db2-bb3e-e6acb7293017">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9f2b1fb1-e0bc-4fff-bf8c-09898f415a1e"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8bf74992-7976-41dd-8319-14d7238fbab2"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_03ca18e3-ab6d-4372-8581-7d7f1a2e4de2"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_62e603f2-6005-4e70-84ef-4a5cc0c9376e"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ba6c4c29-23d5-4f9b-bdf9-0a9c4f4de8e3">(2001,xx5f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2a9b2e3a-40d4-4a7d-b707-dd30692599f2">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea62b87c-720e-4f5d-892e-743af32861e3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1212119-b09e-4019-9a75-6ee886855a93">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1de48cf6-ddc6-43e3-bd5b-f014ecef71b9">Stack Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">...</td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8fe591b6-a8d6-4ab5-8f5d-04ed0cf4dd27"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_38c47774-372f-4d77-a9fd-b11a54ec4839"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8902e521-4b53-4cfb-9881-c9cf37a3d323"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2c869dc-c580-4cc4-9070-a4cc27e103f0"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea065c44-fbab-496d-9712-7bac978bcca0">(2001,xx61)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c2270ee-c25f-467d-966e-e44b586fe5fd">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b9eb9a41-f134-4964-ae46-708e5ac07f89">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e11b57b-eae8-4c09-96cb-9d4f1ca4d53f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3c29fbff-fbcc-460f-bbc1-9fa5b9d741e2">Series Transmitted</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9f0a95fb-2a53-4cbc-be9b-82b4f6b2f37f">(2001,xx65)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ab642497-ff6b-44f7-8c08-e24debfa274f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45fd128c-6767-44ed-ac42-0b49d78ed89c">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c09e4035-6880-4b01-ae52-e435c74b3c9a">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f1680612-e7b2-4dce-8a2c-fef31feedfa4">Overlay Plane Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a34661ae-32b1-4331-a2a4-b049fc6a8398">(2001,xx66)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_70e9b1ba-3a17-40a9-a2ef-6b61c5eb6745">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_387b0558-04dc-4d72-b0e9-44fe44897571">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_83ae3d70-440f-4def-a9fd-4ad0a43fec99">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d2cf68b6-30df-49c4-8296-8ed2add69eb4">Image Curve</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_66543549-b108-467b-88cf-1fadc975c308">(2001,xx67)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f01e702a-08e5-494b-baf6-93e1cebf1209">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_73dd6ba8-1f24-48d2-9148-a752de6e4f21">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2dc22b98-4a4a-4cb1-a02f-613ece40f811">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_978e80eb-aab4-4fd9-ad5c-10a8308cbc64">Linear Presentation Gl Trafo Shape Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ed16b7ec-4652-427f-bcd7-4cf917cf58d7">(2001,xx68)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_163643fa-5176-480a-a39f-76d0a2534089">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_69238eed-166f-46dc-9e47-79ba56ab05ce">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_973a6f82-7d90-4ddd-a675-996f121256ba">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_467ee42d-6bf0-4ad5-b8f5-98e1f15aacb9">Modality Gl Trafo Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_196b27d9-5972-440d-80b9-10f039caa703">(2001,xx69)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6760d9c5-e101-4a76-95c2-b7df586ecfe7">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d1fe6e3-a114-4124-b2ae-3e1c57d7b8ed">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_507dae24-491f-4b35-88b2-1c9196a9b9a0">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e0469b6e-2967-4bd2-a401-9abfc3d28a52">Display Shutter Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aa4cf3c1-d443-4510-bd4d-0a4d25fbc394">(2001,xx6a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ba35c74e-62fa-4a47-b92e-7daa1371a595">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8bb1481a-a428-4c92-a5b7-a77c50d58308">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f65d58e4-d5e3-4094-93a8-ddfbc489ce4a">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5c70baf2-2f85-4892-a01e-b66bca9256d4">Spatial Transformation Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c258fce0-5de7-461c-ab7b-ac3987cf95e7">(2001,xx6b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bba0c52b-02e6-4306-b3b1-34b8e0333c04">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e326b921-f5b2-4184-b4ca-a6cd09734fe9">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c4936b2e-2589-4ab4-b934-073edfbf0521">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_00b5c717-fffa-494e-9040-882bfc217c8c">Edge Enhancement Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_210416c5-25e0-435a-beed-2aff27fccead">(2001,xx6d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d1a14b4b-cd3c-4d5c-bfd2-bd8f65ff0f29">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ac4cc5db-de62-4c6e-9035-0139776785ea">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_58576248-67bc-4d6d-8677-5965c769afa8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fba748f1-12e8-49fc-816e-b83a06ad6335">Text Font</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_92f6f6e9-8937-46c4-bdb5-a8c723b5711a">(2001,xx6e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_deec20e3-0eb6-4fd8-bda4-aa60bbd822ff">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9570a430-f3b7-4ed0-bea9-37f81a57e5e6">SH</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_859cc7c3-58d0-4bdc-8752-c82927e380fa">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_92fee84d-67ba-4c5a-863d-d1f4ffdd8130">Series Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ef185e0-9d3b-4793-9ea6-8f914162f95e">(2001,xx6f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a5c14b60-bafe-4695-a8b8-16a1d96e53ff">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_747d16fd-9385-4c5f-bc5f-76e1abe2e819">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e7f7dbb-6c5c-41aa-b451-45af5960b596">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_11472c90-f347-4562-9403-80289125279f">Mixing Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ad9c862a-3326-4d50-be64-3d287a8988fd">(2001,xx71)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1e4e5233-32fa-4034-898c-3d88d783b910">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bf6add87-8ce9-4d02-8286-ac20de397740">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b4c5bd0d-92a2-41f6-b516-36d0d1a6b159">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b7d22b7a-a80e-4869-a2e0-f146da4387d4">Graphic Constraint</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3a4b9c4c-70fb-4d12-bd3c-d3f40b1381f3">(2001,xx72)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_14334f9d-aab6-4219-895f-7099f5d0d239">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_68f14f39-717f-487c-b440-920030126bdc">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1485f873-9698-4e79-9228-a26c0f3475b8">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_acbd580b-8e71-44e8-afee-b8540a021913">Ellips Displ Shut Other Ax Scnd End Pnt</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64ad580c-c852-4785-af14-fe19a3a52fd1">(2001,xx73)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2f1d4200-3398-4a8a-ac7f-6d410239c315">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2db93620-3cc6-437b-b3eb-237385dbfc77">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b97f81a4-3324-4ddf-bbc7-097c4d1fbb90">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a87d06b-e154-4c3e-9731-6062ea3d272d">Referenced Mask Image Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f593b88a-89f8-4948-ae6c-971ed9f04ae8">(2001,xx74)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_891fa0b9-17de-4bcc-873c-82b5670fa430">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2876763a-465f-4c90-83d9-6ea00acfd739">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bfdaf75e-9f64-4e0f-83f4-74645fee80e1">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_145a4e58-83a7-41ba-bc0c-1f43f07188f6">Window Center Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d3be4c0d-9f95-45d0-ae6e-8ba0e01f2da8">(2001,xx75)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a4ec5508-c9fa-4238-b2e1-01e7684a216b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_31881e67-c21b-4e35-ab27-490a25615833">DS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_50f180ba-ef3e-42bd-8961-043efc19527b">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_902316a1-937c-40df-b891-d25e07bf2e8e">Window Width Sub</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13990143-05db-4ba3-ab91-7dcec7138010">(2001,xx76)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_78ddef5c-5ec3-4ce0-b424-012de7fcdf10">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1dfd6568-e2d4-4287-80e5-2db281b2ddd3">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6344599-cb01-4db2-9f66-9f09c73b984e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c5cce6be-d6a7-439e-9bef-4a17810685a9">Presentation State Xray Contrast Transfer Taste</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_80097b90-a5a7-4dc8-8077-ad9fec8e77bb">(2001,xx77)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1257de3d-3bd3-4a09-a8d5-7e5ddb9dd70b">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ff0674b4-d8aa-4148-856e-5b4eacfcf421">CS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c497240-8e1b-4e60-9cd0-89c4b0ea7cc8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_93373aa1-a783-4b77-8632-655934b20ed6">Gl Trafo Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_101b0194-9ffd-49c2-8e4d-b6855a518759">(2001,xx79)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c60c858f-5ec4-426f-949f-c47a7eaaa82e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7190aec2-9692-4c95-bffa-629a76ced130">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_11614d4b-7ffe-49ac-8616-a2cd665bbc2c">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2f0a447-05e8-4611-8991-dab27a168be7">Harmonisation Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a502eb7b-aa8e-4e6a-85f0-d6cd22eafc3f">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dfdbd4c9-e7a9-4eed-92ef-8bf13a9e4cd7"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1b86ae86-e678-4b13-8246-de333d3ea423"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_416bffa8-840b-46c1-a66f-7e5610d8dd96"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3285e195-c664-4020-940d-de720daa38f8"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dcd97902-2c3b-4b79-9e7e-51e1ff697b87">(2001,xx9a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8568726-e623-4934-a907-1e214f1d8fba">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a91643d-f7da-473c-90e1-bce0281ca082">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f082bea5-61d7-4f65-8252-4be78ec88d50">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_45ac0ddf-7c2e-4250-b016-f05f8aec81f4">Graphic Number Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82395982-c54e-4972-aaac-2391bc9336c8">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2c287638-30ab-4483-8749-ffc7b3095745"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_999731dc-3a3c-4563-abf9-f86b328eb5be"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_96d0ceba-12f7-41b1-81e2-779005894078"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ff4ad72c-38b3-446a-90f0-065e966c9d55"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_36f1de8b-58d5-42f9-8a52-26616f38601b">(2001,xxc5)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2005552c-f2a5-4ec6-ba3c-2cf1e9cf22da">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_545021b0-0444-4470-973a-74f71e8c944c">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ea9d1f9f-f1c9-4b6f-9842-cfcc0ccd2271">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_49e9f4be-37d3-454d-9cec-f5ef623aa9cc">Mask Image Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1492f4e2-e336-456b-b4e5-4a7aa67073f1">(2001,xxc6)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3a2ff7bb-5a80-4334-b7aa-b2ecf4e3f054">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_95244015-799e-402f-9d36-a3a9b7a7c9e2">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ff4cdac9-8036-44af-98bf-cc0bcc5d62f6">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_023b972c-7370-4365-9f59-f3a418d4f259">Gain Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_725269d9-d653-40ea-b03f-1c3fd2e608c0">(2001,xxc7)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2191f4db-3d1d-4e21-9c79-a051847f154e">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2f1dfe4a-d4ad-45c1-99ad-ea1ad412fbc9">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99dff890-7d70-47de-864b-5a77a62b226d">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5118395b-2fac-4c36-b2d9-4a28e02287fe">Contrast Image Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_221aa254-b47b-40ed-804c-5d072fcda02c">(2001,xxca)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c0ac925e-5e6b-4042-80a7-7b0b1122263f">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3f14b408-9422-4280-ae10-2ae4062af988">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db0be053-9582-45a5-93c7-b0bfbe385b17">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8daff18-4067-4357-bad0-5a1521eac368">Reversed Modality Lut</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1d00decb-1c95-4e73-87df-74797fd46821">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f59450ce-d815-45bf-a92b-64d9538e84d0"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90ccbc70-a179-4bc6-b3a4-9c8c65e113e8"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e253c9a4-df14-4d75-883d-99df4c0475d3"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_328acdb0-fff6-4370-83d8-b9320a7d7e2c"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6e1d27c6-8ffd-4933-a48e-3ff58d356aca">(2001,xxe9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dfeaeab1-4d2d-4f29-bfdc-4a30823d2d19">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0490bb74-6bdc-44fe-86eb-6cfe8bfbfa8a">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fa77d2eb-b479-481d-acce-8475f1f801f0">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a643cd8-fb80-480f-85d5-5aab5e609de1">Per Frame Voxels Functional Group</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9824191f-69ca-48e8-868c-03b334b588f6">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18e84b8b-9987-47d0-a7f7-70d54b04b441"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_603f9d88-49cd-4fc9-835a-bb967214fb50"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6dfe2a61-5b88-49c4-b6f3-c994e20484c5"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_db1cc549-1782-4cfd-ac1c-17aac271efdc"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a4ecc794-8742-4482-9e16-4acc694b0f36">(2001,xxf9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6b1d281f-80cf-45cd-bf70-dc4faa682535">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f0118301-7dac-4e31-a8b5-8e139cedbcf4">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_21c8b1ad-1920-41ce-907c-e1d46a5af399">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ac06f9bb-cbab-44bf-bf7c-40ae9a7b9683">Flagging Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c5e5f332-165d-4b05-bb2f-a480fe52d998">(2001,xxfb)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7df47b71-7f6c-448e-9755-b136ac6c72e5">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f6ea16be-f50a-42cc-b7dd-59c0bde4c608">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e3580bb-cdde-4c26-97d0-77ab2bf469ba">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6df50310-cdfd-4a10-9db0-5b478daca794">Bookmark Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef804e88-9a25-426a-8c5e-dce9b224f1ff">(2001,xxfc)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1ff38a1f-9299-4236-ab1a-64c64cb66c44">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_483d6164-4c0d-4cee-835a-89638b3c0958">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c3f47c4f-0505-423b-b073-b6bacec91fe5">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e2671982-b421-40b9-9bdd-98e45d8451cb">Ris Code Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9b18985f-6f0b-4345-b3ef-93ff64503bf9">(2001,xxfd)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d3be0ab0-e31b-42fd-a838-c4fc47c99222">Philips Imaging DD 001</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d80e8ad-38c4-45e4-b707-34640b688d17">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_549ac60c-c39f-45ad-a6ad-bd02ba068e02">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_04685b39-7a68-443e-b4c8-f9375c6883a8">Workflow Step Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_04effd1e-5718-4874-8c33-71753f2c7231">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_86a8fd6a-396a-4706-a75a-5a9b8c83a432"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d242e6f8-9ac8-4330-84c0-a1293d19c919"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_091f0ad2-0e20-48ba-b729-59fb0ad6b4d8"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f58e8827-d63c-4a79-9b4a-c12f3d151921"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_759124ef-e071-41d9-ab0a-b46b6b0d595d">(2001,xx3a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7f117138-193d-4a80-8d47-884a163838a7">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f08f53ea-8e68-4f9c-bc72-d006a74440a4">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94d61953-6153-4e30-be0c-28c3e60c01d8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b90201b8-e6e1-4176-af73-2b8eef23dcac">Ranger Set Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d3c770e0-a0a2-4824-9a6f-5017c117559e">(2001,xx3b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b21c4859-c2b3-43c8-93c9-2f2404009c61">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_746d615f-326d-44d6-82ad-1269b8a5aae3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_77708b38-ac7d-492f-8d65-3befb5d8792f">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_94a73961-1d05-4be6-a53b-d531a240706b">Rox Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e963717-f20e-4ed8-913a-a18c7b030164">(2001,xx3c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_eb99ff5f-309f-4250-9e3b-ece386a8f452">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e477c248-cb57-47e3-a2de-95b1bf5fe656">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_70320636-bdfb-4f6d-8f0b-e3214b982a33">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0dac8b33-1288-4563-a524-878bdb697afa">Xray Edge Enhancement Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_90bde2e3-8401-4c57-b1ac-4b5f6f880aed">(2001,xx3d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4db7a4a2-bcb4-44ab-97ca-f6ac1b067903">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8260d2b8-be34-4d31-99a3-fca9746f2c05">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_52df92b8-d20e-4ff0-9111-aeb35c5e294a">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_82b638cb-c566-42b4-80c9-dd13561bb813">Edr Lut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_64667a43-cf4f-4ca6-be25-41d9bf481528">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_5d8c2d44-7c3d-4427-816c-bfadc4c2d892"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d02d250-29ed-4af1-a8b2-353543127ad1"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_363c4382-6bd5-46e3-a379-14c37e304767"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_21005f88-6e33-4d57-9cc5-29b4da6370e0"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f131da93-d569-4924-98c9-b3150b5b659e">(2001,xx57)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35b8ca9c-0537-4339-b5f1-3190eac37c34">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2c60a958-595d-42e8-ad6e-67b19e5d0683">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_026bfa26-7115-4067-a075-8ffbdb02aec2">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1feab576-a3bb-4d10-817b-c23c2d3f0739">Workflow Step Input Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_46b76d4e-c873-4487-b6d8-67a5917186af">(2001,xx58)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4282a09c-78a8-4d45-9a01-16981200cfd1">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d9e7df4c-a279-463b-9ac0-7d33a481ba0f">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_19bbe88d-7c3d-497f-95ce-b1101ab5cfa8">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d1eeb913-cb7b-495f-9efd-64d94178913a">Workflow Step Output Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_52eec8eb-fa5c-4111-8a6e-574c1ec07795">(2001,xx5a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1f0c4713-679a-4f70-a205-4869f68534f1">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_aab67087-a920-4523-a4fc-988b7fa5bbb8">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9098f323-80b4-4875-b900-80a9bf6925f8">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b9af3f13-f830-48a6-a8fa-79fc00e2e95e">Workflow Step Type</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_78457ca6-849f-4f0b-8452-a0499b166c07">(2001,xx5c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d31b5e8d-ff5f-4e44-978e-6f42479cc442">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_05be740e-0343-40a5-b9d4-f8f4ec28f686">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1188ca0a-d0ac-4ac7-ae25-abe3113372fd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e1f00566-8e07-41f7-a53b-c9f5945bfff5">Workflow Id</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1bbf7479-2d67-40b7-a5d5-d286d733ffca">(2001,xx5d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e65d33aa-d143-4b4e-804a-a2e331b150d5">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_659a0b01-f2b8-49a6-b20f-5e9b5b3da99b">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5be68fc0-7a21-432b-80b2-7a40a86e2b28">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_542e6383-8043-4729-81ed-9426d77e0c0d">Pixel Data Representation Rows</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9a2fce69-2072-49a3-9f83-841897d564a2">(2001,xx5e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dbb9b48a-fad5-451b-97e7-12821b01516c">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bd4d86dc-7e87-43e5-9958-acf30c730c2a">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6daf43a8-8a63-43a9-adef-b6e5d4a681c4">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3e539cd1-165e-4098-acec-4a3aa7640979">Pixel Data Representation Columns</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_630939db-05a7-4050-b306-74fd38e269e1">(2001,xx5f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_253477d7-0a02-4b52-a2b2-c7e7f7e5800a">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b8ef3bd7-0884-46bb-abea-2806c6f0e550">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_bb2cf351-9a72-4283-8c2f-826a05ddb8f6">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6a4d0117-35eb-4458-957b-31bae247ecf6">Private Dicom Extension Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f953e3d7-2c95-4afb-a272-815a2a2c1ba1">(2001,xx63)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_aa3c786b-8815-4d60-9b1f-6419770334e0">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2d67e28a-21d3-4821-ad8c-c9d359628c9e">ST</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_eb85f8ea-4690-48f7-bd9e-872252d9bf2f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_634cc5b6-2132-443e-aef9-b76e3c46097f">Isyntax Reference</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3a1cba3f-b3b6-4e83-ba65-7856cc7e5206">(2001,xx64)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fef4c466-78f9-488f-b4f8-e980fdb67166">Philips Imaging DD 002</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db4ac97b-2da1-49e9-afc1-89e8556857fe">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_424efa08-fb29-4004-b7be-9719e3cf3c5e">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f8654fce-77eb-49de-b0cc-074e549f709c">Workflow Step Job Params Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_79ca8d24-67eb-4cab-a49f-0d781a44d5c6">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ade2f43c-e138-40fb-a195-f2e6b919d738"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_81a2cdd6-42b2-4db5-a925-55d13f92f103"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6e917c9e-4b7f-4c3a-a84b-b6d9a43da514"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_81ae15f8-e34f-4bce-b194-7cf1b318e858"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_de3cb8fc-fd00-48e3-a391-2594486475d1">(2001,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7debed91-48bb-4029-94c0-396d3939c8b5">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b47a478-2e70-4e7f-b9fe-90c60e33d548">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4e472ff9-277e-4789-adcf-b0d81662a092">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b12159f3-41f7-433b-bc37-3c4c25505081">View Geometry</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6cb5f906-4676-416e-9309-2aa3b8fd0652">(2001,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a2a0a955-5722-4316-8aa1-de1375384816">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e5f454f1-c5fd-4fcc-85af-1f2a4a9393ae">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_33ad95cc-89d4-44e5-ad40-e39abbb1e70d">3</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_75c853b4-468b-4939-a64a-ac3d650621d5">Frame Geometry Origin</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8f904a1a-0954-4e49-8de2-27f518620b8e">(2001,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_704aca43-d62c-4024-8076-17b702d0ffdf">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d1fc85d-0b8e-4542-b79e-149ca43d4148">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b5af6a74-5cfb-4807-a3e2-ed23d52ebf80">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0d75a116-1e5c-478b-8f13-eb2056edc218">Frame Geometry Extent</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3faa4a1c-a8ef-4435-aa12-6ac52a2adede">(2001,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c7045521-496e-4e26-b63d-52249f92ed87">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a3c7a07b-e22b-4408-865b-ba19c6810320">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_60668fed-3567-44d6-ac63-b13708f5764e">6</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8960712-287a-4230-99dd-b839d18f7b62">Frame Geometry Orientation</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d2c10c6-cb50-4755-880c-9545253cf460">(2001,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_489fdde5-2e41-4483-b0f3-dbd8d7ea8016">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_824760df-e70a-4903-b748-1b52c2d62e49">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_26411627-1afe-40b2-8ebb-8fab4b41e254">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_13b1170e-7cea-4dd7-98f0-da46240215d1">Visual Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4b65b3d6-c147-4a0a-a8d3-2e634cd30bb9">(2001,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_390542d1-7843-4b65-98db-7321725d5263">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8e6e8ded-87e3-4a30-86bb-09e45c540659">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ac54056-dacf-436f-8a4c-962e77f9efb3">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3dd4153a-ce04-4fe4-9c6d-ecc799b19e5c">Cut Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0fffb87f-17a1-4dc7-beb2-f0485d92f418">(2001,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_56be396a-0bc2-4446-b42c-383904902a4f">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13559a04-f0bd-462c-b77b-d1bb0265ae09">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d81f9a50-33ba-4da6-a533-5c2d83ab431d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0605e8ee-0e21-477e-917f-436fe3f51d1f">Visual Opacity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94f60509-a0cb-46d3-9654-2f294f5f7eb4">(2001,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_56431bf2-71cc-45d1-ab20-a2f14f641b33">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_18a518ad-2ee8-43c4-a726-d1f74581fd00">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_36a19f3d-98a2-4c01-a78a-ff21e10181fe">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ff0eedce-97c7-4346-ac87-7918d511756b">Opacity Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_13d95293-a4cd-4420-8333-52faa048a85d">(2001,xx0a)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c05c5018-f511-47d7-9108-28a0c9f90908">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_106674ed-2330-4452-9dbb-1b6c55d938d4">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e9f01660-3c9e-48e4-92a8-1d278345c870">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d191cb5d-9aef-4378-9fd7-80e789313428">Light Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a81b22e0-ebb5-4d18-ac15-0b468e4ce58b">(2001,xx0b)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7a36c0c9-e445-4f0e-8306-ea6be3be4a87">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be8b92ea-4c0d-4d7d-b1bc-22e702e058ea">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_013f4ea8-519a-430d-bf39-3b1b3bd95188">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3db18f39-c2d7-4330-b171-d366fca52e8b">Color Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4fda1d48-66a4-4399-85a2-01c2748d3dc4">(2001,xx0d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_09214936-8df1-4b6e-b492-ad6a5c5c495a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4ef63568-c850-4bf0-a82c-4d714ff2fae1">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cb4c405a-15fc-4e1f-af38-37deeb489122">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1afce9de-f352-4c48-a968-f56262913e06">Visual Threshold</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fc6ddd8f-94ac-439d-8bdc-83bdb50904a4">(2001,xx0e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ef5d888f-db21-468a-8236-cce053e54087">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c908e43a-3bb1-490b-8de7-19be07b8f6da">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d16b60ae-a932-4ed8-b3ee-f2a3b4ead526">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_17630a5b-a1fb-453a-b3f5-dc1502972e05">Scene Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5997e1da-cf29-413b-9662-a7763cb354b1">(2001,xx0f)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cdd3a5e8-0365-4744-8ce8-9f33cfffab63">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5927ea7e-f395-4490-acb4-372c7ee0e8cc">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_01a93538-a28b-4fe0-a4cd-6234575e870c">2</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_324c2e88-6b29-43fc-b932-ae984f1f5185">Frame Geometry Slab</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a52104b0-739a-447c-9029-7de447b3a082">(2001,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_61a8dbb7-8ff1-49a9-948d-c19e38688e00">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_693b3a2c-8e7c-421a-b894-c0b1237bceb1">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef15257e-c170-409c-9202-f63616b74572">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_631c6993-1008-4d7e-9583-42cd7b65c6a1">Gradient Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_806cba7c-5f67-4d9a-b5b6-fe4d8423c0e9">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d59c08e7-db83-4e5a-80e3-d464601ae096"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7e7e0117-fb82-479f-94a1-8d76b2cb789f"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_706f68e8-2d9c-4223-acd2-2dfc56470655"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fef2828f-3ee5-4363-8c46-a61106bc9a9a"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a855f353-ba75-41b4-a999-e4a3b6b9f927">(2001,xx2e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f407543b-313d-4f76-97e5-b9897077d203">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_472688ed-4615-4da0-96d3-ab207c3977df">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2dbb46c9-804f-45ee-9d9a-195ddba736bf">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_6e8d16d3-bdf1-4705-987d-cf1779f07a65">Volume Mask Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ee32cd22-ef89-4a9b-b6e8-a76e20f13d84">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_773e1f95-c7bf-47d0-a8fb-57e632dd90e3"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a639e6a4-c6a3-4885-ab88-087e72c4d5e8"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_305ad3e1-b11d-4995-92e1-7735c2a2b4fb"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0a9d424e-31d1-456b-9353-68577c6a8389"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7d4d4ac3-4c02-4f67-9e92-f1b8eb9bd628">(2001,xx3c)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7f5cb970-f0e0-4787-b817-a675b00b240a">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_79c90e05-bb74-4030-a3b2-edeb31ea969b">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_09034458-5452-419d-97cf-7c7c8ad65e0f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_30c63a2a-0443-4918-84c4-f30a8f66ab4e">Intensity Map Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0bf8b895-3909-44ab-aa58-6753e696be00">(2001,xx3d)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_2fb9474e-da62-4e22-97fb-5450a944c515">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e95652aa-74c3-41b4-9f84-17f234ffd344">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6116e5a8-eac2-42f3-a2c8-3e5778f3fe8b">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e6f4bc83-93ae-447d-b382-5157877dc16c">Intensity Map Samples</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f0b0176e-d309-459d-af14-f6d283ced962">(2001,xx3e)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_cfa55fd6-0e4a-41da-99a0-18e54956f2a4">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b4fe8beb-0703-45cc-9037-9110e4c9f106">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4a6a4dc0-6162-4c5b-9719-4a13fde158b8">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_77b6be8b-10ce-4b1d-abb3-057cefc87151">Mesh Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4af01d1a-1c42-4f86-a310-416bc0dec323">(2001,xx40)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_bd0f5d0f-3a8d-47af-82f8-a2aa19448980">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9e62f0b0-4d0a-47e9-a929-3ac1673660ff">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d0bac80-77f9-428d-832a-dbc62c4195e0">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_01e627c2-0b23-49e7-a8d5-eba894dfd648">Mesh Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0fe5ff59-f13b-4da6-ab12-4ce5eda05c11">(2001,xx41)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b8c08e54-0813-4174-8bd3-c4f99897bff9">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3295e7d0-33e9-4073-a31a-184ac5208d07">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_58bcff52-97b2-4bed-8c11-61000c71afff">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_775ab032-4358-4613-b143-64163c1fe319">Mesh Draw Style</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d67f5cad-ca81-41d2-b57f-73ec11b79731">(2001,xx42)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_76f7f83a-0bb5-40d1-9b63-b87816a936cb">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1adf4c5b-9e35-4d99-8d6d-b39ad9f5cbf3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76eee998-4707-45f8-a6ce-8d18c2e742f1">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c5cb16ae-05b2-42ce-a56c-1eb75dc414df">Mesh Section Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c59e5624-71af-4777-99d4-be45184261ce">(2001,xx44)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d967d7d3-2be3-4692-9f2d-f5bdade00c83">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1e68e8d5-cf87-4c88-a6d1-0656455c6da2">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_408591ea-a36f-4659-960b-33a2f74ead08">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b83a7d14-83d1-47c9-9eee-47d4d670934e">Mesh Section Vertex Connectivity</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99fe1e79-b1b6-452b-bf09-992d64d47174">(2001,xx45)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_172d3683-9274-4143-8e0c-6815cb55066f">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b82fb44e-c968-4e2f-a3dc-7e99d3486285">SL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_74d299f6-9346-45d2-920a-612b4f75c74c">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_81626579-a5ae-4e34-b559-f3aa74ea7a6d">Mesh Section Vertex Size</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e95f7c6a-65b8-4f4d-85e1-fb07bb71cb56">(2001,xx46)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ede64168-d5ea-42cc-a641-5f5a5c524471">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2bd9e050-249a-4b21-bd82-430e24d08f98">LO</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_644327a3-ade0-4b49-a52f-92e88e716a6f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b1724c02-3e2a-42cd-b914-bfa38971a367">Mesh Section Vertex Format</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_94a777bc-4e6e-4f6c-9749-16011340a092">(2001,xx47)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_288765fb-b97f-437e-804c-10743720a675">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6cd5e76-349c-4787-a169-c4821482641b">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ecaecd89-e60e-472f-b607-24cc21108359">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_0df0b3d6-31c8-4153-ac82-a45d9dc4e490">Mesh Section Vertex Data</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a600c1eb-e9f1-42f0-8c90-09e747ad13c0">(2001,xx49)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d8625592-c30b-462f-a88a-c78032096276">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e436d7dc-cfce-45a3-800c-3dc3e3eb8e78">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_99d4be42-d9aa-48bd-934b-b158bdf4b4a3">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_58815a5b-f05a-44bc-a61b-b6dda6d29775">Referenced Volume Definition Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f8d23302-ef6e-432e-925b-21be687bd99e">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_45672fc5-187c-4b20-a053-fbcaf263a24d"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7e656c88-f590-4f4e-b3e2-1da156043884"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ebb60a39-ccd4-42b9-b9c0-478f30277adf">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_51009a91-04a8-419f-9311-9f08c2cd9704"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_384f4c84-3946-4ecc-8df4-1fd7e5081722">(2001,xxa9)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_84214fe8-7526-4434-b754-e8adabd3ef8c">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6395902c-cd58-42bf-b297-a7987663f2f0">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_76b588df-5ad4-4df3-b88a-5dda84a5a886">0-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_97bdeed0-364e-4bd3-8e5c-048445eadec5">Linear Modality Gl Trafo Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_04eef47f-5a62-4bcc-b4e5-e794d609573b">(2001,xxaa)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_ab2ae099-c640-46c5-9bd3-aa1a6810e6f4">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6de267c3-de05-4077-8f91-3dae39960028">FD</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20a30a14-2c7c-4d52-812f-822e913d98e8">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d845c849-ecef-43d6-aaec-b50dd2ec69b7">Volume Slice Offsets</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d4eb0877-1182-4f52-a397-ec46ef87a316">(2001,xxab)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18cd65d6-5c91-45f2-8ac5-6d46f6ebefbb">Philips Imaging DD 097</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8430aec3-166b-4d6d-b1f4-e42ff71da9a5">IS</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_921d5771-4d9d-46c8-8765-42064cc5422a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8a1d8599-7a59-4300-8c9c-74358e2b3dd4">Number Of Volume Definitions</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a06745e0-151d-4c08-a609-8a1172c1c9ac">(2001,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_738df125-b080-44cf-b609-646fb926bebc">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_756b97ef-9021-40d7-9794-7eb89da28662">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a7010a2c-4004-4095-bd89-d3ecb1089c20">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_90425a77-ba63-47c4-a7f8-db94daec7b57">Presentation State Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f5ead1d8-22c2-4c59-b643-6c00c1d063ea">(2001,xx01)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dce57a56-1e19-43c1-affd-6d169f789ecf">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_93bb7a8e-916b-4ea7-a198-f36d8726a477">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_9de446e0-ab5b-45ff-9aa4-d9c5d39b9566">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b646314f-7618-4b10-8c7d-8f622e399f27">Embedded Original Presentation State Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_354a449f-3231-4788-ad14-cfd6f8589b4d">(2001,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8ca02309-21b1-4f7a-8486-a2c8fa86ea63">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5c2f2aae-c288-4789-80fa-d95406bd2c89">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1b666e72-41a9-4af3-b45f-7984d33db1e4">0-1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_33e129b3-eb65-4481-b8c4-13643fc2c15d">Planar Intersection Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_91e4187a-eacb-4089-b3c1-6003287f0b71">(2001,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dc6fcef6-0621-41b2-8b70-d2f988b56e9f">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_150f55a8-46f9-4fca-973f-d2fc62222dc9">UL</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_15c2f598-80da-4162-9c60-0c5bed3c6363">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_695ed2e7-899c-405e-8e80-0cc56f6f752e">Plane Separator Line Color</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c7b2b93a-ca7a-41b3-9e47-722a03622bba">(2001,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_be618399-eebc-4271-86fd-bfad0ff2f93a">Philips Imaging DD 129</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5a781824-ba1b-4eda-8296-83a73180c809">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ce932bf2-ed9a-4c74-ad45-154e691b40e4">1-n</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31d9b0a5-6fdf-4ac2-b69f-1364ac3e0564">Plane Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a71a4c62-f14c-4bdd-8b1c-626c4417dc8e">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_35d713a7-3e13-46d9-ba69-a6de09f55d35"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_60fdd66d-06ff-4238-a946-261b97b4ffd3"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_97870a35-8547-46d4-af94-8f244ab02427"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_3cf220b4-9692-4789-aa03-fdc170457e07"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6d30e134-774a-4009-8cdc-d53681fb09e4">(7E01,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_95a9cb5b-b584-46eb-8298-9aaa319721d6">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2ff9dd4c-246d-4dcb-82f7-e89ab5be8089">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_14145676-100c-41a3-87d4-7ba031c7a490">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d641600b-cf7f-40d2-9d3b-354c7e9180b8">High Resolution Data Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a714e9bf-958d-4d51-928d-7ca7486bd837">(7E01,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b895a268-9a9e-4ec4-aaa1-ba9c81090f22">HOLOGIC, Inc.</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1087d744-b36f-44b0-a7b4-231745e65740">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0ad68691-badd-4cf1-866f-3ba649f1e677">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_33383e5a-1540-4cd3-8b02-27ea54fc0534">Low Resolution Data Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_db2a7176-486a-4978-89e9-eb1c1cfba963">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7cdf9c1f-1944-4d55-bf1c-13e8edcc567e"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3b0e13c1-1ed6-497f-ba86-3a2549cad152"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_2516dfb7-9be8-441b-aca3-b71b84472145"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_dd87b3ce-154e-46a0-80b9-ea0a923e844e"/>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_e6202d74-c65b-4b94-8aca-d8560c50d1ba">(0119,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e9b04935-b16e-4827-b986-0f7be1747814">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_45e218d8-0197-4dc9-85ba-388850861090">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3dcdea4f-8d71-4de9-ab8a-97b99a18166d">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_92d74b24-7d95-439b-bb6e-713c7a4836f4">Multi Stream Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_a741376a-d13a-4942-bf49-fc647d76fb10">(0119,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_718f785f-be1b-4c17-a529-2440a0fc11ae">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7b840e29-8f5b-43e6-b33f-504cf04395fd">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_3aa4b0ac-a2a7-467b-ab81-bb4dd0bc434a">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8862e8e4-8c20-4d66-af60-f4a29f9028ab">Acoustic Data Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_be5f8423-75d7-460b-9c24-55bb4035cbf0">...</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_f3391dd7-0dcc-4ff8-b413-94718897a478"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4f7d90a2-57d0-4820-8495-ff1bf737c82a"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_dc8fe350-e51a-4680-8c32-991f327895dc"/>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a9ed3cb2-5799-4e8e-aa6f-a1a27d025b3d"/>
                                        </td>
                                    </tr>

                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_20b5ad8a-eba0-447c-b7bd-322f05476c21">(0129,xx00)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e127247e-e06a-46e4-b6e3-cd3b41b143b6">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_1d15d432-0282-490c-a2ff-03c9862524c6">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d0f497a5-519d-40c8-b87e-cee08f807842">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a6184b2c-7b36-418f-855b-6af16c20bc29">MPR View Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f1eee3f0-701f-44ef-8b18-0d4ecb88adf4">(0129,xx02)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7308a16f-c3b1-4028-9584-8f639eb1e42b">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_c5bac947-8af5-4d37-8289-37d061870a07">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4d6466bb-2d3f-49d0-bea6-d297617fa0ea">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_e0a0f11e-30da-4ec1-8844-f0017a51f35e">Bookmark UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_fbd355ad-1dbe-44c2-8ae8-2ac91d4847be">(0129,xx03)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d3cc32ba-5c5a-4e5f-9d67-2f84fcf2dca8">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cd107e00-7f5d-4068-8603-13c576b02ceb"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_44cb7d0d-ab29-4f80-a08b-e3eb2122c749">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d70caaf2-6778-4a65-901f-a8ae685cac58">Plane Origin Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_ef29b6ee-fbad-42b5-b28b-a4ef2efdd0a2">(0129,xx04)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31fa6369-2b12-4c4d-829c-e7a3d38d1966">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7ac4dc96-0269-48cd-84b4-e4b93a7a9458"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_8803c927-ec0c-4d7a-81fa-41a345eef9fd">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_31a10ba2-0eb2-44ea-8086-be3a1d78c661">Row Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b825a5ab-e99e-46fd-9768-94b8bd8641a9">(0129,xx05)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_708ddbbd-5482-439d-a6a0-264d701eaf18">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d6de09d1-e2db-4731-9cf3-26242a39e19c"/>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_5958872c-abf5-4ea2-97e4-200b35819c45">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7a63527d-dd36-4e87-80ca-26b022d32ec0">Column Vector</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_4f594f9a-a845-4c1f-8f32-0629a658b671">(0129,xx06)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_b06f835b-fac1-4662-ab15-dd7b749e6055">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_480a221e-bb19-4e1d-aae7-2398713cb0d3">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_44c018f3-85f5-4478-b4ad-688874a2356f">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_d2a39b42-9746-4046-851c-cae26fa352c3">Visualization Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f27ef0f1-4207-409f-9ba1-fef6036e2c57">(0129,xx07)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_a0aa4676-56b8-428f-8e6c-c1d8c318bc52">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_6255aada-1088-44d5-8757-4862fc12b9e9">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_abb3000d-1fef-4d9e-b52b-5924492e7b3e">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_fe4a7b6e-fe61-44e0-83bc-10a40a21e55b">Bookmark UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_02d772db-80bc-4278-b068-08c919c25922">(0129,xx08)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_9bafb603-c577-476c-9ec1-bfd4441fbcb6">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_699790fb-d6a1-4ba3-9854-14d5b4c6dc75">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_308c86ba-e9a1-4d28-a4af-8065a55c9528">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_729427fb-02db-4ec5-b1a6-e04785084eb3">Visualization Information</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_785c2f71-a55e-4395-9f39-4f5c9ecdcd60">(0129,xx09)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_8b7cafeb-b33b-487a-9971-6c7f0c50445c">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_b39c940a-ddbe-4c90-abf1-f67cf6b015cf">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_82aadf23-4901-41dc-8fea-6f64777da5ea">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_4a8a556d-df5c-4e1e-a1fb-8fb48fa4378d">Application State Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_902e3b5d-ebac-4fca-8bc3-ccd8e5f9b1ee">(0129,xx10)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_88ea089a-9431-42a0-a598-b21e0ed12931">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_40525cc1-8ecf-4c70-b09d-81ab305d424d">OB</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_0d4df1b3-6745-4b5d-ba45-4a32d7d9b1f7">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_c8deef0f-21f5-41ba-a315-ddff2abbc1b0">Application State Information</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_01ea828d-d0cc-4194-beaf-dc75197b1d1a">(0129,xx11)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7be58f9f-5131-47b2-8917-7358e5d0c69b">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_7f1cb4bd-2f67-4abb-a65d-12298fe72db9">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_409a24a4-c4c8-471f-958a-523af2b57c5b">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_75b2ec68-f54d-429c-8ce0-30640ccbfbf1">Referenced Bookmark Sequence</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d1754819-cc20-4601-8a99-5195d8a84c83">(0129,xx12)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_329dfcd5-ec00-4538-8e78-9ad7a92e1dc3">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_244c23dd-b979-41a6-8d89-4d91c8070ee3">UI</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_df4d0f5b-472f-4d27-8b15-f9e7fd956238">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_7be934ce-9beb-4138-bb3b-a3738b01518e">Referenced Bookmark UID</para>
                                        </td>
                                    </tr>
                                    <tr valign="top">
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_d14698f4-1058-475f-b567-8c785328aedb">(0129,xx20)</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_1a4652b1-8c8f-4cc6-88ed-d93bbdba4be3">SIEMENS Ultrasound SC2000</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_f109a9a1-77df-4705-85d9-cb00c7aee3c5">SQ</para>
                                        </td>
                                        <td align="center" colspan="1" rowspan="1">
                                            <para xml:id="para_cac817fe-5222-471c-bb06-5c51343e1936">1</para>
                                        </td>
                                        <td align="left" colspan="1" rowspan="1">
                                            <para xml:id="para_18b90359-d47d-4dbf-a119-592f4210e737">Cine Parameters Sequence</para>
                                        </td>
                                    </tr>
                                </tbody>
                            </table>
                        </listitem>
                        <listitem>
                            <para xml:id="para_940fd19f-fdf0-4f34-bc15-04ab81391520">One approach to retaining Private Attributes safely, either when the VR is encoded explicitly or known from a data dictionary (such as may be derived from published DICOM Conformance Statements or previously encountered instances, perhaps by adaptively extending the data dictionary as new explicit VR instances are received), is to retain those Attributes that are numeric only. For example, one might retain US, SS, UL, SS, FL and FD binary Values, and IS and DS string Values that contain only valid numeric characters. One might assume that other string Value Representations are unsafe in the absence of definite confirmation from the vendor to the contrary; code strings (CS) may be an exception. Bulk binary data in OB Value representations is particularly unsafe, and may often contain entire proprietary format headers in binary or text or XML form that includes the patient's name and other identifying
                                information.</para>
                        </listitem>
                    </orderedlist>
                </note>
                <para xml:id="para_74598302-fb52-4831-9a57-fa49e4698746">The safe Private Attributes that are retained shall be described in the Conformance Statement.</para>
            </section>    
        
    </chapter>
</book>
