<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2413</title>
    <subtitle>Clarify Admitting Diagnosis meaning and add other types of diagnosis</subtitle>
    <chapter>
        <title/>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/11/11</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/05/04</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2413</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Clarify Admitting Diagnosis meaning and add other types of diagnosis</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.6, PS3.15</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The only description of diagnosis in worklist messages and storage objects is Admitting Diagnosis Description and Code Sequence,
                    and these have circular definitions.</para>
                    <para>ICD coding guidelines have clarified distinct meanings of diagnosis in the context of hospital care, specifically distinguishing admitting, principal, primary and secondary diagnoses. In addition, there is a need to specifically convey the histological diagnoses, if known.</para>
                    <para>Improve the definition of admitting diagnosis, and add coded attributes for the other types of diagnosis.</para>
                    <para>Include them in the de-identification profile clean descriptors option, since commonly private codes will be in use and their meanings may contain PII.</para>
                    <para>Clarify the relationship to Reason for Visit and remove references to obsolete HL7 table of codes.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="C.3.2" status="3" xml:id="sect_C.3.2">
            <title>Visit Identification Module</title>
            <table frame="box" label="C.3-2" rules="all" xml:id="table_C.3-2">
                <caption>Visit Identification Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_088acb17-ec59-4dcb-8ccd-b614cf4a8ef0">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_593bfdb2-3fc6-4f8a-afae-f5b421bcc467">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_682abe21-4967-4f18-8bab-ef1d31bc2808">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df3b130b-d11f-4a3f-b642-0be4e5ab5330">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1e2a6ba1-18a0-4ffb-8961-72eaad4d09ad"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_0b40c1f2-288a-4c7d-a4f2-a13c1084ff7b"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6331cdaa-8c89-454c-bb13-79354af38bd2">Reason for Visit</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ada0d2fe-436f-4842-9f7d-9dd1980a2ead">(0032,1066)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b5e6a467-d86e-40e9-a209-8d65de391180">Reason(s) for this visit by the patient to the facility or provider.</para>
                            <note>
                                <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same value as Admitting Diagnoses Description (0008,1080).</emphasis></emphasis></para>
                            </note>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cdc9f7a8-aff9-49f4-94bb-76cba990c8c5">Reason for Visit Code Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0550f9da-bfa4-43c4-881c-abfd35a51dd4">(0032,1067)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9018b5fd-8381-47ea-b94d-112b44d40f39">Coded reason(s) for this visit by the patient to the facility or provider.</para>
                            <note>
                                <para xml:id="para_ff83d830-7dce-44f7-850c-a0caeb3042c2"><emphasis role="bold"><emphasis role="strikethrough">If an HL7 message is available with a PV2 segment corresponding to this visit, potential codes may be found in Admit Reason PV2-3.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same codes used in Admitting Diagnoses Code Sequence (0008,1084).</emphasis></emphasis></para>
                            </note>
                            <para xml:id="para_5adc95f8-99ed-4ef7-b1dd-99d28cf09c1c">One or more Items are permitted in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para xml:id="para_2bb190eb-f7b9-4bd5-aa45-c80e59b98897">
                                <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df9db370-61ff-4fe1-bc75-f0051fea2eec">
                                <emphasis role="italic">No Baseline CID is defined.</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_50c7db2b-d9d7-42e1-9746-5cd38d6e8861">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a237d94a-19fb-4b26-8956-30577bef6994"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a364855c-dc11-4a35-a20d-72891c62d5de"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        <section label="C.3.4" status="3" xml:id="sect_C.3.4">
            <title>Visit Admission Module</title>
            <table frame="box" label="C.3-4" rules="all" xml:id="table_C.3-4">
                <caption>Visit Admission Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_465e247b-4de7-491d-b4b3-6e36ad3619f8">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b37455c4-e22e-4360-8edf-50a65fb6a321">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4f2eaaf3-f66d-4439-9eac-58f16d9fd550">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_12e1cb89-ade5-41ad-849d-220e49850799">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_41143bd6-d263-4a66-b3c2-4950f6367dd3"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7dd3f835-701f-4b2c-8ed2-4c75d043c1d3"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_df7779bd-0d67-49d4-83a8-d9f34803ebf6">Admitting Diagnoses Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_98ebaeda-4fa9-4c5c-9c77-317b7a7a51f9">(0008,1080)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_842b23af-76df-44aa-8703-5bf4bc034b15">Description of <emphasis role="bold"><emphasis role="strikethrough">admitting diagnosis (diagnoses)</emphasis><emphasis role="underline">the reason(s) the patient sought care</emphasis></emphasis>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1e95a90b-b0e9-4502-8b4e-8d50c7f636e9">Admitting Diagnoses Code Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_07f7a700-5f44-476c-b7ee-cde25b534038">(0008,1084)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5324ee23-4d10-4a92-b9d1-ad82fa240900"><emphasis role="bold"><emphasis role="strikethrough">A Sequence that conveys the admitting diagnosis (diagnoses)</emphasis><emphasis role="underline">The reason(s) the patient sought care</emphasis></emphasis>.</para>
                            <para>One or more Items shall be included in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para xml:id="para_22c368d4-fc2f-4579-9596-bda7d9390ba1">
                                <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b5260c2f-1c41-47fc-96de-f74585451f98">
                                <emphasis role="italic">No Baseline CID is defined.</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Principal Diagnosis Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(gggg,eee1)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Condition, that after investigation, was chiefly responsible for the visit.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Primary Diagnosis Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(gggg,eee2)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Most serious and/or resource-intensive condition during the visit.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                            <note>
                                <orderedlist>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">The primary diagnosis may or may not be the same as the principal diagnosis.</emphasis></emphasis></para>
                                    </listitem>
                                    <listitem>
                                        <para><emphasis role="bold"><emphasis role="underline">The use of the term "primary" in this context is not related to its different meaning in the context of cancer, i.e., it is not necessarily a condition that is a primary tumor, which might be encoded as the principal diagnosis, if appropriate.</emphasis></emphasis></para>
                                    </listitem>
                                </orderedlist>
                            </note>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Secondary Diagnoses Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(gggg,eee3)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Conditions that coexist with the primary diagnosis, and that affect care during the visit.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Histological Diagnoses Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(gggg,eee4)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Diagnoses that have been confirmed by anatomical histopathology of specimens removed from the subject.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                </emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9522d2a0-790e-4771-9d56-eba4ad843506">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c58894e2-5e87-45ed-9b30-17a33543e6ab"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_84865fea-5b73-4dcc-8dad-4856a9e8a27e"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="C.4.12" status="3" xml:id="sect_C.4.12">
                <title>Imaging Service Request Module</title>
                <table frame="box" label="C.4-12" rules="all" xml:id="table_C.4-12">
                    <caption>Imaging Service Request Module Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7a2057f9-c228-4f32-a73a-88dd127489ee">Attribute Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_bf956c05-3212-4b10-80aa-def83ae49a4e">Tag</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8b891292-3fe5-46fc-b5a4-a9ec4cc0cb4a">Attribute Description</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_64dde37c-176d-40c7-9606-98907f62502f">...</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3827263b-a82c-42ee-beef-8655cf313eb3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_067a9a99-49ef-499d-8efa-992e60308cf3"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2f3f3d78-b13d-41f3-8818-022334f0c2c6">Reason for Visit</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_18320342-fd69-4981-9e10-e649bf529a87">(0032,1066)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1cd8bbe3-26f6-431e-9818-6607af3d9f3d">Reason(s) for this visit by the patient to the facility or provider.</para>
                                <note>
                                    <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same value as Admitting Diagnoses Description (0008,1080).</emphasis></emphasis></para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d7be0f9-6226-424e-ad82-5adb8faed85b">Reason for Visit Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_008ac479-97af-41f9-84b1-179741402197">(0032,1067)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8732bf29-c8dd-40f3-abd0-7239e4b99608">Coded reason(s) for this visit by the patient to the facility or provider.</para>
                                <note>
                                    <para xml:id="para_4907a07e-6003-4d88-96ee-49933e306b53"><emphasis role="bold"><emphasis role="strikethrough">If an HL7 message is available with a PV2 segment corresponding to this visit, potential codes may be found in Admit Reason PV2-3.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same codes used in Admitting Diagnoses Code Sequence (0008,1084).</emphasis></emphasis></para>
                                </note>
                                <para xml:id="para_9d2428c5-2056-4f28-9225-e19d542cc16c">One or more Items are permitted in this Sequence.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para xml:id="para_067a2ecb-e8fa-4ba2-ab1f-098f5edaefdd">
                                    <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_af10a008-7421-4b5a-bd33-7f55d0720f87">
                                    <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                </para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        <section label="C.7.2.2" status="4" xml:id="sect_C.7.2.2">
                    <title>Patient Study Module</title>
                    <table frame="box" label="C.7-4a" rules="all" xml:id="table_C.7-4a">
                        <caption>Patient Study Module Attributes</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8c387979-6485-4890-9fec-8b12305f465c">Attribute Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_27efa895-0222-4274-a64a-f6048b9b0711">Tag</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_573f94bf-f6e1-4c77-a9cc-914d2905a871">Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8fc94b1f-c086-42b9-9279-d534cb5600cf">Attribute Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6dd1236b-bfbe-4a49-b928-820bd20f08d8">Admitting Diagnoses Description</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d6609747-22ff-413c-9b42-be3ac20b8acc">(0008,1080)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4c0e384b-b88c-4995-8b06-45508dccc273">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_256aaf16-bfde-4b20-b47e-71098db56f42">Description of the <emphasis role="bold"><emphasis role="strikethrough">admitting diagnosis (diagnoses)</emphasis><emphasis role="underline">the reason(s) the patient sought care</emphasis></emphasis>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_afe946f6-cdf4-454a-8a4a-d950a612025f">Admitting Diagnoses Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e8f32821-a4bd-4493-8b34-42f13ac4ad5b">(0008,1084)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f524227a-ed47-4456-b647-1d4d58dd3533">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0acf143b-f485-492c-989e-df462347be39">
                                <emphasis role="bold"><emphasis role="strikethrough">A Sequence that conveys the admitting diagnosis (diagnoses)</emphasis><emphasis role="underline">The reason(s) the patient sought care</emphasis></emphasis>.</para>
                                    <para xml:id="para_8ad13a6d-2c81-484d-985a-9a147ac0eca6">One or more Items are permitted in this Sequence.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_d9fb2f9f-4420-4796-8c45-0e99d1222d15">
                                        <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82595536-83f6-46f0-bdf1-ed8e7fa19bed">
                                        <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Principal Diagnosis Code Sequence</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">(gggg,eee1)</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Condition, that after investigation, was chiefly responsible for the visit.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Primary Diagnosis Code Sequence</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">(gggg,eee2)</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Most serious and/or resource-intensive condition during the visit.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                                    <note>
                                        <orderedlist>
                                            <listitem>
                                                <para><emphasis role="bold"><emphasis role="underline">The primary diagnosis may or may not be the same as the principal diagnosis.</emphasis></emphasis></para>
                                            </listitem>
                                            <listitem>
                                                <para><emphasis role="bold"><emphasis role="underline">The use of the term "primary" in this context is not related to its different meaning in the context of cancer, i.e., it is not necessarily a condition that is a primary tumor, which might be encoded as the principal diagnosis, if appropriate.</emphasis></emphasis></para>
                                            </listitem>
                                        </orderedlist>
                                    </note>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Secondary Diagnoses Code Sequence</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">(gggg,eee3)</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Conditions that coexist with the primary diagnosis, and that affect care during the visit.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Histological Diagnoses Code Sequence</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">(gggg,eee4)</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Diagnoses that have been confirmed by anatomical histopathology of specimens removed from the subject.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_161f3281-2cf7-4d79-8955-260778416558">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_302433da-951f-41fd-b1e1-c28805c88511"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_59bad819-6581-4a22-a035-8a2bc2b5315c"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b96b3f14-1689-48c1-a6aa-ef0b445b74e5"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b593fb9-bbc6-405d-8061-87a1c5b856eb">Reason for Visit</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_50b1d89b-2b31-4b01-8f9f-7e236d7e4a9a">(0032,1066)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_752e24da-325b-4c45-a557-8c34ffe9e937">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9eb94283-55bf-4f0a-a54f-ad22def929db">Reason(s) for this visit by the patient to the facility or provider.</para>
                                    <note>
                                        <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same value as Admitting Diagnoses Description (0008,1080).</emphasis></emphasis></para>
                                    </note>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_80b18d6f-2808-4158-a5c6-e5ba9f98f799">Reason for Visit Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_34d951a0-0a8d-4adf-ba83-a97f4d4a66ed">(0032,1067)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5567a5e6-600d-4181-9994-902853b995a5">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_508f2fbc-e04d-4cc2-9d1d-b23595a6fa9b">Coded reason(s) for this visit by the patient to the facility or provider.</para>
                                    <note>
                                        <para xml:id="para_a4c07bbd-7b10-4b67-8623-4985e3a83d68"><emphasis role="bold"><emphasis role="strikethrough">If an HL7 message is available with a PV2 segment corresponding to this visit, potential codes may be found in Admit Reason PV2-3.</emphasis></emphasis></para>
                                        <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same codes used in Admitting Diagnoses Code Sequence (0008,1084).</emphasis></emphasis></para>
                                    </note>
                                    <para xml:id="para_a21f41d0-a133-4bb3-9254-0180606c0ff5">One or more Items are permitted in this Sequence.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_f980b7c5-867b-425d-b7cb-98caf3994f74">
                                        <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d8074441-c0e9-4541-9d57-7df6c30f1e3f">
                                        <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_90613c11-5588-4ec4-971f-2dc0a0343617">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f534cbd0-33d6-4195-ae29-b3a468af75ad"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8e568738-bb6c-46fd-8723-b01d1af98207"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_57d3e92e-1ce6-4fbd-a4b3-52132c036bfc"/>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
        
        <section label="C.13.2" status="3" xml:id="sect_C.13.2">
            <title>Basic Film Session Relationship Module</title>
            <table frame="box" label="C.13-2" rules="all" xml:id="table_C.13-2">
                <caption>Basic Film Session Relationship Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7972c820-2467-4aa4-bb80-548f30f88d84">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82e34827-47ad-43df-bfe8-3b3630e1b60c">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f857f4f1-69c0-4157-89c3-5721d88d9662">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8b1ef631-8796-4338-a741-2b236a88da7c">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7dd50da6-b5db-43e8-9355-71d2a847d477"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_28c9b1d6-a2b9-4ae8-b64d-a04dbd5ffe06"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8f0aad0-ed3d-4304-adf6-d31a906fb442">Proposed Study Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7935f665-6ff7-4489-ab21-6dc55dfb6f3d">(2130,00A0)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0f4d56f-1af1-4602-b51e-30e6d2041a27">Attributes that may be used to identify and describe the Patient, Study and Series that are the subject of this Film Session.</para>
                            <para xml:id="para_b42eff0c-d7bd-4a54-8901-33ae5b3f2ebc">Only a single Item is permitted in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fae14a11-0c4a-4189-9e94-6ae385e68a90">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ae8f0361-9d88-45ba-b449-a455f257ff45"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7c1c5009-0c9f-4c16-a1a8-85f1ab0df66d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_64a50d6d-c186-4f7a-aca9-aaa17aad15da">&gt;Admitting Diagnoses Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ad2b080-f6ce-437b-94ff-48902801d924">(0008,1080)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1b077a89-e9cc-44d0-b723-6626b043d391">See <xref linkend="sect_C.7.2.2" xrefstyle="select: label title"/> for description.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_42d176eb-8da6-4bdd-974d-55d25159366e">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_180a84f2-c934-4e1c-966c-2dace6862eac"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_4436b6cf-03eb-4843-925b-aeb46169b8c9"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="C.30.4" status="3" xml:id="sect_C.30.4">
                <title>Unified Procedure Step Relationship Module</title>
                <table frame="box" label="C.30.4-1" rules="all" xml:id="table_C.30.4-1">
                    <caption>Unified Procedure Step Relationship Module Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c5e8c1c5-9f3c-4cdb-a530-4986436cbaa5">Attribute Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_af9080e6-a8da-426f-88f2-db0a65875d03">Tag</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a91bb3ef-93db-4719-8304-6ee89f74a66a">Attribute Description</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32b59205-47fd-4bb4-ad6b-57ff4024ca04">...</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdeb45d7-6ef0-4667-bec5-38cfe7c15d09"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d78fc152-cd49-40df-a719-1465244efec1"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e3a0871a-c777-4e89-812a-2f9058ed1c6d">Admitting Diagnoses Description</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b2cdf2ec-c5eb-421f-b2e5-6309f463459b">(0008,1080)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ddf1ddb2-0b08-4334-b05e-e59df1e2c34c">Description of <emphasis role="bold"><emphasis role="strikethrough">admitting diagnosis (diagnoses) for the patient</emphasis><emphasis role="underline">the reason(s) the patient sought care</emphasis></emphasis>.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06d5427c-03f6-46a4-a262-8a945739c63b">Admitting Diagnoses Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0f3906b3-d815-466d-9247-1a34c94a03aa">(0008,1084)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_defec100-20e0-4aab-bf5b-3ceac65160e5"><emphasis role="bold"><emphasis role="strikethrough">Coded admitting diagnosis (diagnoses) for the patient</emphasis><emphasis role="underline">The reason(s) the patient sought care</emphasis></emphasis>.</para>
                                <para xml:id="para_4605d6b5-7971-4524-8c17-026eb8323e32">One or more Items shall be included in this Sequence.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para xml:id="para_1ba26760-8318-47d3-ad13-b2b7f35ed1ea">
                                    <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_604a9a09-ec97-490f-9485-93c1b860db67">
                                    <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Principal Diagnosis Code Sequence</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(gggg,eee1)</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Condition, that after investigation, was chiefly responsible for the visit.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Primary Diagnosis Code Sequence</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(gggg,eee2)</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Most serious and/or resource-intensive condition during the visit.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                                <note>
                                    <orderedlist>
                                        <listitem>
                                            <para><emphasis role="bold"><emphasis role="underline">The primary diagnosis may or may not be the same as the principal diagnosis.</emphasis></emphasis></para>
                                        </listitem>
                                        <listitem>
                                            <para><emphasis role="bold"><emphasis role="underline">The use of the term "primary" in this context is not related to its different meaning in the context of cancer, i.e., it is not necessarily a condition that is a primary tumor, which might be encoded as the principal diagnosis, if appropriate.</emphasis></emphasis></para>
                                        </listitem>
                                    </orderedlist>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Secondary Diagnoses Code Sequence</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(gggg,eee3)</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Conditions that coexist with the primary diagnosis, and that affect care during the visit.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Histological Diagnoses Code Sequence</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(gggg,eee4)</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Diagnoses that have been confirmed by anatomical histopathology of specimens removed from the subject.</emphasis></emphasis></para>
                                <para><emphasis role="bold"><emphasis role="underline">One or more Items are permitted in this Sequence.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/></emphasis></emphasis>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para>
                                    <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">No Baseline CID is defined.</emphasis></emphasis></emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fa4f9cff-4239-498d-b5f6-782e9a83c5f0">Reason for Visit</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d628b58-dd4b-46b4-9abe-a11fbac4dd8e">(0032,1066)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f7ce0e5-db1f-455f-952c-b2e9646f14c7">Reason(s) for this visit by the patient to the facility or provider.</para>
                                <note>
                                    <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same value as Admitting Diagnoses Description (0008,1080).</emphasis></emphasis></para>
                                </note>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5889fe60-6ca0-4e30-a466-98092414bf0c">Reason for Visit Code Sequence</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2e0537f8-6e6d-48df-bbdb-371207bd4468">(0032,1067)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5fed15d-0f15-4c18-9f39-6ce614772805">Coded reason(s) for this visit by the patient to the facility or provider.</para>
                                <note>
                                    <para xml:id="para_abd8efe5-fb40-4b39-b724-ffadfe7e8795"><emphasis role="bold"><emphasis role="strikethrough">If an HL7 message is available with a PV2 segment corresponding to this visit, potential codes may be found in Admit Reason PV2-3.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">This might or might not be the same codes used in Admitting Diagnoses Code Sequence (0008,1084).</emphasis></emphasis></para>
                                </note>
                                <para xml:id="para_c019ce5c-d4b4-4de5-bf22-932e2f941138">One or more Items are permitted in this Sequence.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="2" rowspan="1">
                                <para xml:id="para_da26914c-9403-40f7-90d6-4be5c8b66ff3">
                                    <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                    </emphasis>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_57af9c3f-0ca6-487f-95f4-927df83cda3d">
                                    <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7fa72392-f960-4fe1-b85b-3d3fb2c246eb">...</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9f1c1c6a-3944-405a-b9a5-fb143813ecb8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_503be83a-e1a4-4d64-a789-a492da481ebc"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        
        


        
        
        
        
      
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.6 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
      <section label="6" status="1" xml:id="chapter_6">
        <title>Registry of DICOM Data Elements</title>
        <table frame="box" label="6-1" rules="all" xml:id="table_6-1">
          <caption>Registry of DICOM Data Elements</caption>
          <thead>
            <tr valign="top">
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_3e8c52d5-3582-4ec4-a7e6-acd7604caf32">
                  <emphasis role="bold">Tag</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_ac298c3b-bcdd-462b-9240-c38e738bfb7c">
                  <emphasis role="bold">Name</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_99f6b0ff-e1b0-484e-83b5-c3003d61704c">
                  <emphasis role="bold">Keyword</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_42b3621d-8b30-46eb-8992-10bb21310ac7">
                  <emphasis role="bold">VR</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_551ea829-a949-4bfd-a201-bb102024e64c">
                  <emphasis role="bold">VM</emphasis>
                </para>
              </th>
              <th align="center" colspan="1" rowspan="1">
                <para xml:id="para_3a18713f-2e81-4664-b9a1-e4e3d41957ab"/>
              </th>
            </tr>
          </thead>
          <tbody>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_be8c87ed-0ca2-4f4c-821d-f3df4030bf7e">(0008,1080)</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_a37267aa-01f9-4d22-b2ef-53eb718a0107">Admitting Diagnoses Description</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_5fd1445e-c6ba-4f01-8833-211a6508fbea">Admitting​Diagnoses​Description</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_c346116e-80c7-4cc2-b1c0-10d0c949583b">LO</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_74be94d6-97c9-4a64-b459-09b4a5b0f614">1-n</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_5cdcc70d-984e-4d61-a8f3-0fe6d2365f60"/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_9a9072f7-56f0-48b6-a998-7101b0e430f4">(0008,1084)</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_911ba45e-15dc-4d64-a8e9-766459a1c977">Admitting Diagnoses Code Sequence</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_f375a586-44c1-4c63-b8f2-881b0c635979">Admitting​Diagnoses​Code​Sequence</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_b042d63f-9135-47e3-a40a-824ebd4921a5">SQ</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_03cc73de-5d6a-4f97-be71-46605f7391f9">1</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_330881b7-daef-450b-a501-f1f1baba49a9"/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_13c8b1e0-6fe2-47ba-8bb3-42239e009c81">(0032,1066)</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_6c856cf5-9e63-40e8-8747-f33065c4a33e">Reason for Visit</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_b9bb4eb5-2c3b-4973-bd7e-8badd8684db4">Reason​For​Visit</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_9ef7c2dc-571d-41e4-ae5f-f1991c669a82">UT</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_3415c27b-49f0-4daf-89b3-04466e9f3430">1</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_d8a81a2b-1c00-4646-a17d-66695d0b5ffb"/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_827b122b-50e6-4099-9add-97784f239009">(0032,1067)</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_84bec03d-f6c0-4702-a6b9-b8a85421856e">Reason for Visit Code Sequence</para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para xml:id="para_c713ca89-3add-4896-9597-7661ab211a0d">Reason​For​Visit​Code​Sequence</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_7ca4b013-33df-43f8-96b6-7a022629a98d">SQ</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_8348da3e-c78d-47df-82e6-45d217198273">1</para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para xml:id="para_d4f587e6-dbdd-4839-b474-705e7a0abe62"/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(gggg,eee1)</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Principal Diagnosis Code Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Principal​Diagnosis​Code​Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(gggg,eee2)</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Primary Diagnosis Code Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Primary​Diagnosis​Code​Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(gggg,eee3)</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Secondary Diagnoses Code Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Secondary​Diagnoses​Code​Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para/>
                  </td>
              </tr>
              <tr valign="top">
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">(gggg,eee4)</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Histological Diagnoses Code Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="left" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">Histological​Diagnoses​Code​Sequence</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                  </td>
                  <td align="center" colspan="1" rowspan="1">
                      <para/>
                  </td>
              </tr>
          </tbody>
        </table>
      </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.15 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="strikethrough">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <table frame="box" label="E.1-1" rules="all" xml:id="table_E.1-1">
            <caption>Application Level Confidentiality Profile Attributes</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c5e6e8ba-34e0-4e31-90b5-bd9ed7086ddd">
                            <emphasis role="bold">Attribute Name</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_d02d5580-8438-4a00-8c30-ba93530bcd31">
                            <emphasis role="bold">Tag</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_705936dc-2c42-4198-b406-ba0e61b35e99">
                            <emphasis role="bold">Retd. (from <olink targetdoc="PS3.6" targetptr="PS3.6" xrefstyle="select: labelnumber"/>)</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_a8387cac-386f-4ad9-96b3-b3dcb1b1010c">
                            <emphasis role="bold">In Std. Comp. IOD (from <olink targetdoc="PS3.3" targetptr="PS3.3" xrefstyle="select: labelnumber"/>)</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_fc0ff9a1-5780-4d06-861a-24ae0ba38b47">
                            <emphasis role="bold">Basic Prof.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_19ddb67a-a5d6-474d-a13f-8df27d28b707">
                            <emphasis role="bold">Rtn. Safe Priv. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5b335431-5276-4cc0-bddf-93b6d107226e">
                            <emphasis role="bold">Rtn. UIDs Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8317e0cf-0080-48f9-8040-1f49a4478c0f">
                            <emphasis role="bold">Rtn. Dev. Id. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1ba661a2-a572-420a-95c1-bc1bf694a70e">
                            <emphasis role="bold">Rtn. Inst. Id. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_796841da-6b27-4558-99c9-99503edccc6c">
                            <emphasis role="bold">Rtn. Pat. Chars. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_edac8181-290b-4f9c-945d-5dfc7b1a43fc">
                            <emphasis role="bold">Rtn. Long. Full Dates Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6305752d-56e7-4f4d-b9d8-e5052fcd6eea">
                            <emphasis role="bold">Rtn. Long. Modif. Dates Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_84f3b128-8fe5-45bc-b04e-abc483377b06">
                            <emphasis role="bold">Clean Desc. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0adc5d55-1196-4265-8ee1-b205103c96f1">
                            <emphasis role="bold">Clean Struct. Cont. Opt.</emphasis>
                        </para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5e74e547-b6fd-410e-9c09-b271915c3eeb">
                            <emphasis role="bold">Clean Graph. Opt.</emphasis>
                        </para>
                    </th>
                </tr>
            </thead>
            <tbody>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_15c97b8c-2113-4cff-b311-fd3295a88867">Admitting Diagnoses Code Sequence</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6c9d47dd-6081-448e-9bcd-b283febf4351">(0008,1084)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_ea1309e5-e199-44c8-a82a-e3b8feb6e6f3">N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9ccfebb5-60d4-4f35-8387-df8eb1cf0450">Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81e95ca4-43e3-4f33-801b-994bbe043ea1">X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_79de8700-4bbd-4c6d-aade-957b860c5c7b">C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_23bffb9d-ad86-43ab-b443-72d75537f2ce">Admitting Diagnoses Description</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_8052ea0d-3819-4867-9f82-4d57fd859603">(0008,1080)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_040a7b67-3198-4772-ba18-f66d11bc92b6">N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_0c7a4caa-2681-4b42-8106-14641425fb69">Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_73e1882f-1173-42b7-8642-ac514329cdbf">X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_1f2e117d-d68f-48de-8fac-2232760c7f9d">C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Histological Diagnoses Code Sequence</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">(gggg,eee4)</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Primary Diagnosis Code Sequence</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">(gggg,eee2)</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Principal Diagnosis Code Sequence</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">(gggg,eee1)</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_b08901b8-e374-4dda-9bc1-3e3773d77ea4">Reason for Visit</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f243db69-aab6-41ae-bf53-3c23e796e9f7">(0032,1066)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_967a7d2f-0fa2-4112-91b3-49d360170732">N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_602f928c-00cc-46ad-9565-31783ea82dba">Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_81cb5e35-83da-496b-9c3d-3114a05ce290">X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_9496b251-34ad-461c-a150-86f690cb00ac">C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para xml:id="para_cfb200ef-016e-4e18-957d-884baf8bb1c4">Reason for Visit Code Sequence</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_95d97680-912d-46e3-9481-939656815ff3">(0032,1067)</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_6b6321b9-3f20-431a-bd95-477c482b5dac">N</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_c264d2ae-78a2-4d77-83d7-5571e37b1772">Y</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_850efefa-8d3f-4356-acce-1b7b8a980308">X</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para xml:id="para_57e93aa9-87f8-43ae-ab85-63b187bba23e">C</para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
                <tr valign="top">
                    <td align="left" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Secondary Diagnoses Code Sequence</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">(gggg,eee3)</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">N</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">Y</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">X</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1">
                        <para><emphasis role="bold"><emphasis role="underline">C</emphasis></emphasis></para>
                    </td>
                    <td align="center" colspan="1" rowspan="1"/>
                    <td align="center" colspan="1" rowspan="1"/>
                </tr>
            </tbody>
        </table>
        
        
        
    </chapter>
</book>
