<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2382</title>
    <subtitle>Add derived measures of similarity for ROIs</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/01/14</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>IDC</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/12/15</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2382</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add derived measures of similarity for ROIs</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>Similarity measures like Dice, Jaccard are needed, for example for comparing different segmentations for ROIs.</para>
                    <para>Note that the measurement values of each ROI that contributes to the derived measurement, are specified by reference; i.e., they actually need to exist elsewhere (with the ROI specification via coordinates, segmentations, etc.) elsewhere in a TID 1500 invocation.</para>
                    <para>Also need to add concepts for number of pixels or voxels, since those need to be recorded for each ROI and used as the source for the reference.</para>
                    <para><emphasis role="italic">[Ed.Note: Surprisingly, the count of the number of pixels or voxels is not defined as a distinct measure in IBSI, though often used as a parameter to compute other measures.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Do we need a different derived template between two regions (or sets of points) that does not depend on there being source measurements for each, the use of which is a bit contrived and doesn't actually encode the full information used in the computation, e.g., number of points in the intersection.
                        Probably not, because reference from the derived template is to the Measurement Group container, and any source measurements are Type U so can be omitted anyway.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note; Do we need parametrized metrics like Weighted Hamming Similarity, Taversky Index, and if so, how should the weights be communicated? Eelbode T, Bertels J, Berman M, Vandermeulen D, Maes F, Bisschops R, et al. Optimization for Medical Image Segmentation: Theory and Practice When Evaluating With Dice Score or Jaccard Index. IEEE Transactions on Medical Imaging. 2020 Nov;39(11):3679–90. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1109/TMI.2020.3002417">10.1109/TMI.2020.3002417</link>]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: What about geometric measures, e.g., Hausdorff distance, that are measures of similarity but not overlap per se., and what modified forms of them should be included +/- parameterized (e.g., "95%":</emphasis></para>
                    <para><emphasis role="italic">1. Huttenlocher DP, Klanderman GA, Rucklidge WJ. Comparing images using the Hausdorff distance. IEEE Trans Pattern Anal Mach Intell. 1993 Sep;15(9):850–63. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1109/34.232073">10.1109/34.232073</link></emphasis></para>
                    <para><emphasis role="italic">2. Dubuisson M-P, Jain AK. A modified Hausdorff distance for object matching. In: Proceedings of 12th International Conference on Pattern Recognition. 1994. p. 566–8 vol.1. Available from: <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://ieeexplore.ieee.org/abstract/document/576361/references#references">https://ieeexplore.ieee.org/abstract/document/576361/references#references</link> doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1109/ICPR.1994.576361">10.1109/ICPR.1994.576361</link></emphasis></para>
                    <para><emphasis role="italic">3. Zhao C, Shi W, Deng Y. A new Hausdorff distance for image matching. Pattern Recognition Letters. 2005;26. Available from: <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1016/j.patrec.2004.09.022">https://doi.org/10.1016/j.patrec.2004.09.022</link> doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1016/j.patrec.2004.09.022">10.1016/j.patrec.2004.09.022</link></emphasis></para>
                    <para><emphasis role="italic">4. Fedorov A, Billet E, Prastawa M, Gerig G, Radmanesh A, Warfield SK, et al. Evaluation of Brain MRI Alignment with the Robust Hausdorff Distance Measures. In: Bebis G, Boyle R, Parvin B, Koracin D, Remagnino P, Porikli F, et al., editors. International Symposium on Visual Computing - Advances in Visual Computing. Berlin, Heidelberg: Springer; 2008. p. 594–603. (Lecture Notes in Computer Science; vol. 5358). doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1007/978-3-540-89639-5_57">10.1007/978-3-540-89639-5_57</link></emphasis></para>
                    <para><emphasis role="italic">5. Aydin OU, Taha AA, Hilbert A, Khalil AA, Galinovic I, Fiebach JB, et al. On the usage of average Hausdorff distance for segmentation performance assessment: hidden error when used for ranking. Eur Radiol Exp. 2021 Jan 21;5(1):4. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1186/s41747-020-00200-2">10.1186/s41747-020-00200-2</link></emphasis></para>
                    <para><emphasis role="italic">6. Aspert N, Santa-Cruz D, Ebrahimi T. MESH: measuring errors between surfaces using the Hausdorff distance. In: Proceedings IEEE International Conference on Multimedia and Expo. 2002. p. 705–8 vol.1. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1109/ICME.2002.1035879">10.1109/ICME.2002.1035879</link></emphasis></para>
                    <para><emphasis role="italic">7. Zhang J-W, Han G-Q, Wo Y. Image registration based on generalized and mean Hausdorff distances. In: 2005 International Conference on Machine Learning and Cybernetics. Guangzhou, China: IEEE; 2005. p. 5117-5121 Vol. 8. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1109/ICMLC.2005.1527845">10.1109/ICMLC.2005.1527845</link></emphasis></para>
                    <para><emphasis role="italic">]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="TID 1420" status="3" xml:id="sect_TID_1420">
                <title>Measurements Derived From Multiple ROI Measurements</title>
                <para xml:id="para_9df250f6-e02c-4765-8c7c-c09a36421a6f">This Template encodes measurements for some metric, e.g., density, flow, or concentration, which are acquired over some defined sampling (e.g., over successive time slots in a dynamic contrast enhanced acquisition)<emphasis role="bold"><emphasis role="underline">, or of some comparison between different ROIs</emphasis></emphasis>.</para>
                <table frame="box" label="TID 1420" rules="all" xml:id="table_TID_1420">
                    <caption>Measurements Derived From Multiple ROI Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9e411d11-543b-4a68-a43e-f5aee7f147cc"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a7e5a8c8-6ddb-44a0-b404-6c4cc0e110b0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f9cc89e6-e72f-4f6b-9701-a4165fbfc528">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5ccced9a-84f4-40d4-b0aa-4d02b57864ff">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0649b26-7bfd-4862-86b7-69fe6518eb5d">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0e0aefd-ebea-4ce0-869b-2233498051c9">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_339298a8-6e97-4ca8-86c8-83766e448893">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1fe7962e-a065-4e2d-959d-c3134c125593">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_251c8a3c-517b-453f-b01c-cab4a7fa527f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5533c73f-7886-4274-8930-42f6160092b7">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5479196b-844e-4b40-bb1e-bd23a4278211"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9e69788e-f643-4955-8248-53f4656c21b2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_60ce69a0-334f-4ca7-bd9c-32dbb3ce11fc">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0d68e7d-1fb5-4e9e-b17a-69b9a21cede0">D<xref linkend="sect_CID_7465" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_05584e7b-106b-4d86-9d6d-64cdda4bd877">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a52ab315-7c59-4be9-8b69-6f7fcdc162bd">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bcf70806-f8a1-4067-bdc5-9f6adabc297e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_006cc400-6f06-448c-9ff7-2b8010bd2556"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_218e9c9e-86d8-43e9-9c0d-ae46df2fb716">1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_995ee572-5241-4349-a159-36602b0cf57c">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3c7b76ca-422c-4170-a8f1-be26b2a9ef39">HAS CONCEPT MOD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70b681ad-6ca7-40f0-a634-94717d77a4a0">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ade24d3f-4f3b-451d-a568-bb5582a40105">D<xref linkend="sect_TID_4019" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d471817-4ad6-4e9c-a0cb-98bec2b5f912">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_be8c765c-0160-4e6d-adfc-5eb15f26d307">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_be6cfd54-7eca-4762-a341-33c263a6685d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96dad921-d448-492a-b197-c0b6bf98ca0b"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0842058b-1f38-49d2-9d70-41a27e946f44">2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_232a17a7-0233-467a-b793-9011f7a68d0d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d9b847b-1c67-4055-b4fd-8ed3fd4239b4">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4304021-1c04-4e26-9f91-af9a6636b940">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d30f6fa9-b814-44b7-801e-6180cc9af335">D<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_752dc534-660b-472e-b2e6-d5543e4b4281">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9a8134f-162f-492a-b9b5-036e9fe6a8e0">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20665cc5-9a8c-4300-8aba-55a9fd65dbda">XOR Row 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed8b0bb4-7c39-4a36-9595-69136b75e1ea">$Measurement = ...</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b4b43efe-c43e-4aa1-8d26-e8eb21ab0192">3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1bf454b8-5fd0-4592-a0d8-5d124967c897">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b11a61f-7f7a-4708-9440-e0cfe1cf30bf">R-INFERRED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_67305b7d-896a-4870-b829-3d029184825d">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_177f5996-bb22-4ed4-a2ba-a5b539dc8a6d">D<xref linkend="sect_TID_1411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_93771a4c-527c-47ba-be5e-3cde20f6db5b">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4a4bbfb9-8502-46b0-985f-ec76d3f7a933">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51924fb0-2153-4458-ac8f-ce4390c6e17e">XOR Row 2</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0b12e1b0-abfe-4d24-b6dc-62dc575d5edd">$Measurement = ...</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0dfc43fd-c883-4ad7-8f6c-9e943ef0046b">4</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e075582d-a65d-40b2-b359-16eab5fa2bf6">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70ebe3d3-c2f8-49ea-a19b-85ecf29e86e6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b01c11ac-ff8e-476e-9361-25f82fd6e672">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c75f5d10-36e3-4b4b-acc1-e5452c147208">D<xref linkend="sect_TID_310" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c5a8443-34d7-41a8-8dc7-1d1f08ab2dd5">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_00132e42-a53f-42fb-a8e5-e6fb25235738">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_886b417e-1899-4793-b792-ae322d5fb39a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eda3d1e5-fb1e-4d75-821b-3f54d3e045a7">$RefAuthority = ...</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
                <para xml:id="para_ab33149a-38bc-46fe-9836-4d6aa9136e7e">
                    <emphasis role="bold">Content Item Descriptions</emphasis>
                </para>
                <informaltable frame="box" rules="all">
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_26f45afc-2c7f-4e64-82dc-dd6eb4cb6497">Row 1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97b50270-9192-4555-9303-852ce5d3d288">Specifies the type of derived measurement reported, e.g., the mean of the individual ROI mean density values<emphasis role="bold"><emphasis role="underline">, or a similarity measure of the number of pixels or voxels in the ROIs</emphasis></emphasis>. Note that the units may be different from the units in the ROI measurements</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9154321b-fd04-40cc-bd46-f60d23d28b67">Row 1b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a9b68056-9891-4823-9cd8-7476324ca573">Describes the algorithm used to produced the derived measurement, as opposed to the referenced measurements from which this measurement was derived.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8272c8ea-678e-4534-a73a-82b2a54ebe77">Rows 2, 3</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_945c7f06-a608-44e2-a953-1297b8f948f9">The measurement values of each ROI that contributes to the derived measurement, e.g., the mean density within an ROI<emphasis role="bold"><emphasis role="underline">, the number of pixels or voxels in an ROI</emphasis></emphasis>. These are specified by reference, so as to not have to repeat the ROI information when it contributes to multiple derived measurements (e.g., if both mean and SD of ROI mean density values were specified).</para>
                            </td>
                        </tr>
                    </tbody>
                </informaltable>
            </section>
        
        <section label="CID 7465" status="3" xml:id="sect_CID_7465">
            <title>Measurement Derived From Multiple ROI Measurements</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_835ff505-2761-4236-9521-123e4276f408">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7465.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-7465-MeasurementDerivedFromMultipleROIMeasurements.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-7465-MeasurementDerivedFromMultipleROIMeasurements.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.952.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d5d98eee-71c6-4b90-bf1b-5982ed3bde04">
                            <emphasis role="bold">MeasurementDerivedFromMultipleROIMeasurements</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_eacd66d6-3753-4c25-b78c-5df5f969afd2">
                            <emphasis role="bold">dicom-cid-7465-MeasurementDerivedFromMultipleROIMeasurements</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d69a7330-bd89-460a-9bd9-a5049c151d28">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_843b382e-9e78-4cd5-813f-fdd42cfed570">
                            <emphasis role="bold"><emphasis role="strikethrough">20121101</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_5901c058-3c5d-42c6-80ac-4035afddfea9">
                            <emphasis role="bold">1.2.840.10008.6.1.952</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7465" rules="all" xml:id="table_CID_7465">
                <caption>Measurement Derived From Multiple ROI Measurements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c0fa1933-c01f-43b5-b6aa-7d11777b2fa6">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56d02399-04b3-4a2b-a09f-5e7420f35f57">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf083689-c819-47ff-bdfe-7821efcb23fa">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_b8f515a1-1a1e-4ef9-8477-e7e61124befb">
                                <emphasis role="italic">Include <xref linkend="sect_CID_226" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_825fcb01-6b42-42b2-9ec7-40aed2445834">
                                <emphasis role="italic">Include <xref linkend="sect_CID_227" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/></emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 7469" status="3" xml:id="sect_CID_7469">
            <title>Generic Intensity and Size Measurement</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ea2a84ce-a848-449d-84af-90cbbda52580">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7469.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-7469-GenericIntensityAndSizeMeasurement.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-7469-GenericIntensityAndSizeMeasurement.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1003.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_386014f4-791a-4a59-b318-33fec221d9e6">
                            <emphasis role="bold">GenericIntensityAndSizeMeasurement</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2e0c5761-544b-4b2b-9d99-e108dc5ece6b">
                            <emphasis role="bold">dicom-cid-7469-GenericIntensityAndSizeMeasurement</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6a75cc1e-2f95-46f0-90c5-21190e6aadd5">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_13f55a11-9c24-4c6d-a016-2b62890b7f2e">
                            <emphasis role="bold"><emphasis role="strikethrough">20141110</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_f80d1bb6-18fd-4f46-8aae-803475085f16">
                            <emphasis role="bold">1.2.840.10008.6.1.1003</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7469" rules="all" xml:id="table_CID_7469">
                <caption>Generic Intensity and Size Measurement</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_da4f3e26-0e58-41c4-afd2-f5e0c5437d96">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_af75bce2-f7e4-4337-a1c2-49a7bdc2c504">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bbae1bf-f764-40af-ad33-0fd180a5741d">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_7d5813fe-198b-458c-83fd-61d902ef1a01">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7180" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_7ecdc418-171c-4e3c-89f7-daa2f7e3fade">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7470" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_83fcba24-f472-47b1-babe-50d2ad9d4266">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7471" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_c5867b3e-d47d-4a74-baa6-d9b6a9e33900">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7472" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd003" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">ddd003</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Number of pixels</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">DCM</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd004" xrefstyle="select: nopage"><emphasis role="bold"><emphasis role="underline">ddd004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Number of voxels</emphasis></emphasis></para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
 
 
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new context group to DICOM PS3.16</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="CID ccc1" status="3" xml:id="sect_CID_ccc1">
            <title>Similarity Measure</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc1.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-ccc1-SimilarityMeasure.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-ccc1-SimilarityMeasure.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">SimilarityMeasure</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">dicom-cid-ccc1-SimilarityMeasure</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">yyyymmdd</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">1.2.840.10008.6.1.uuu1</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID ccc1" rules="all" xml:id="table_CID_ccc1">
                <caption>Similarity Measure</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para>Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd001" xrefstyle="select: nopage">ddd001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Dice Similarity Coefficient</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link linkend="DCM_ddd002" xrefstyle="select: nopage">ddd002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Jaccard Index</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new concepts to DICOM PS3.16</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
                <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">Definition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">Notes</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd001">ddd001</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Dice Similarity Coefficient</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A measure of the pair-wise overlap of two sets defined as two times the intersection of the two samples, divided by the sum of the two samples. Also known as the Sørensen–Dice coefficient. The samples may be points representing pixels or voxels in a geometric region.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>1. Dice LR. Measures of the Amount of Ecologic Association Between Species. Ecol. 1945 Jul;26(3):297–302. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.2307/1932409">10.2307/1932409</link></para>
                            <para>2. Taha AA, Hanbury A. Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool. BMC Med Imag. 2015 Dec;15(1):29. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1186/s12880-015-0068-x">10.1186/s12880-015-0068-x</link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd002">ddd002</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Jaccard Index</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A measure of the pair-wise overlap of two samples defined as the intersection of the two regions, divided by the union of the two samples. Also known as the Intersection Over Union (IoU). The samples may be points representing pixels or voxels in a geometric region.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>1. Jaccard P. The Distribution of the Flora of the Alpine Zone. New Phytol. 1912 Feb;11(2):37–50. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1111/j.1469-8137.1912.tb05611.x">10.1111/j.1469-8137.1912.tb05611.x</link></para>
                            <para>2. Taha AA, Hanbury A. Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool. BMC Med Imag. 2015 Dec;15(1):29. doi:<link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1186/s12880-015-0068-x">10.1186/s12880-015-0068-x</link></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd003">ddd003</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Number of pixels</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A count of the number of pixels in an image or a region of an image.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr><tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="DCM_ddd004">ddd004</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Number of voxels</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>A count of the number of voxels in a volume or a region of a volume.</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged DICOM PS3.16</emphasis></para>
                </td>
            </tr>
        </informaltable>
                    <section label="TID 1410" status="3" xml:id="sect_TID_1410">
                <title>Planar ROI Measurements and Qualitative Evaluations</title>
                <para xml:id="para_47a24b81-ef09-41fc-b6aa-1cd54a1889dd">...</para>
                <table frame="box" label="TID 1410" rules="all" xml:id="table_TID_1410">
                    <caption>Planar ROI Measurements and Qualitative Evaluations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_30b4aee0-ea2f-4145-8208-793586b42cc7"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e2114728-d791-431b-9191-bc8f10b33fb6">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ebe5dfb8-ae20-4bef-910d-06c15730b75b">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_11076f1d-2653-47e3-867d-98687bcf34d3">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0e28dd32-3fea-42af-ba33-fb3836638cf4">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b53dfca1-52dc-4c1a-86ae-6e7da6594631">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdfbf0aa-9607-43d3-8888-66cb7b9ecd25">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_98188a1d-f8c2-4703-b93c-1bbbda3c1e56">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4191d21b-4639-4e6b-9acf-3961b18247e2">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bda96106-9fc7-43dd-a450-a91a0a6e6fca">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71a85977-09a6-44a2-8acd-8142481e9370"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_489b564d-d244-477d-bd40-a3039fc941b6"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f6aa1279-28cf-49b4-9778-3eec192f8b70">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f372076d-6d4d-4f09-bbdc-e10f7d314c85">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b6fcff3e-4c4d-4a1d-a7ea-d26a8443c9e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_da8a0eb6-8b06-4635-a02a-cba4d9ce5d6d">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_71881a64-73b5-48d6-b0b0-fbe9806900be"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_07f57d22-61b8-4875-bd89-d3283d0dbdcc"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_409f6e6d-f887-4f49-8b11-989188aedec1">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ee6fd942-0371-4fde-9638-f2a8e67e6fcb">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_208032d8-b7e8-4af0-bd71-840b23278e24">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b68aa0a9-d0b1-475c-9630-fbbd48dc581d">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aeb2a487-642c-44a7-8b45-d6d50adb365f">EV <link linkend="DCM_111030" xrefstyle="select: nopage">(111030, DCM, "Image Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ae8bf884-64d7-40bc-97dc-e6a4d7a6db83">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c2d8f97e-e24e-4591-b38a-f69d71824f03">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7056160c-74ff-4830-8ffe-c048ab696afc">XOR Rows 7, 7b, 8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9fc59e52-3212-40a3-aea4-5b89635d1073">GRAPHIC TYPE = not {MULTIPOINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2fd976b5-86d6-402a-a25e-e1d3ad8c71df">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b61af4ca-9a37-482f-8823-7f1b73b7eaeb">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61538b3d-d790-4596-b395-7e7f083e18c0">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5d898cf3-65ee-46c1-a19e-17ebe5d0def2">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3a46a4c1-9af4-401e-80fb-9f9265a270db"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_584a39b5-760d-4662-8675-3367175e20bf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_45965ebc-e1d3-40dd-b11f-72e8e7169770">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8337874b-0930-408d-a290-518ba3f2656c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bf3b656-2906-4808-a9d0-762fee69b54c"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d5a0bc4-a020-44ab-a211-f17a9fa83246">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dafa9592-2b76-411a-9dfb-b07bf3f4bdb5">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37c5f744-ec7b-4ecc-96c5-ce5e33d14f03">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e873d36-d3af-4f1c-9fd1-79cc437ae752">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0840dc73-1210-4877-a6fe-5c287e00c5b6">EV <link linkend="DCM_121214" xrefstyle="select: nopage">(121214, DCM, "Referenced Segmentation Frame")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_3c544407-674c-4954-98c4-405cae664c59">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f37e245-08d0-46b3-b446-4b1b9955370b">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b26463d-cb66-40bc-a179-c245a1aa6541">XOR Rows 5, 7b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_24dd541b-fcbc-4cc8-9364-0a8fee6741cd">Reference shall be to a Segmentation Image, with a single value specified in Referenced Segment Number (0062,000B).</para>
                                <para xml:id="para_5995e360-45b7-4da1-9a36-7d44c42edb84">For references to tiled Segmentation Images, one or more values shall be specified in Referenced Frame Number (0008,1160), unless all frames in the referenced Segmentation Image are selected and there is only a single Segment, in which case Referenced Frame Number (0008,1160) will be absent. The referenced tiles shall all be in the same plane.</para>
                                <para xml:id="para_ef39be61-c197-4e5b-9a06-24d364045741">For references to non-tiled Segmentation Images, a single value shall be specified in Referenced Frame Number (0008,1160), unless there is only one frame in the referenced Segmentation Image, in which case Referenced Frame Number (0008,1160) will be absent.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f9c960f-d44e-4440-9762-3fbf05b80de1">7b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e882976-fa30-4757-8905-259512b4b924">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_558c96de-5729-4bc5-950f-56bd85dd47b0">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1a723f9c-a6d6-4e75-b433-68c8c2724875">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac4f927a-6af9-48a5-bb6c-cf20f9ffaa8e">EV <link linkend="DCM_111030" xrefstyle="select: nopage">(111030, DCM, "Image Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_29311599-70ad-48b6-8b6f-c6177681c7d0">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6208f3a4-b6a6-43c0-b1f8-eb799bb5d2fa">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17e1358f-3b6b-4611-9676-982717a42680">XOR Rows 5, 7, 8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_61b5c76f-1055-46bd-832f-9f5f1db0bf8d">GRAPHIC TYPE = not {MULTIPOINT, POLYLINE or ELLIPSOID}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd6f4e6d-bfaf-469c-a569-678a3e28a45c">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eb47db7-af21-475d-9bd6-a2c3f16dfdde">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e07e9e71-53c6-4d5a-899e-6fd1ae56665b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ff3d0c74-1592-4dfc-bc58-b7beb4433ffb">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_97ea6a5d-9ccb-4e07-b9e6-00d50cf38213">EV <link linkend="DCM_121233" xrefstyle="select: nopage">(121233, DCM, "Source image for segmentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ffa90db0-e98e-4257-ab76-0e13a9c0376f">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_cb697351-58d1-4567-ad0e-5ddcd6258d27">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb70c3c6-b10e-410f-a1b4-71dce1ecdad9">IFF Row 7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8d18206-d68b-49d1-8f4a-863567c5f41d"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5ea82210-3c64-43bf-aac5-1af720196ee7">8b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5f1b492-58a0-4f45-9879-7b234a84b364">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_579783d7-e532-4442-a50c-17925633046d">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef51c5ff-9a74-4976-810b-447f94ef0724">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cf76fa15-fe33-4fed-9682-ae784b730b84">EV <link linkend="DCM_130488" xrefstyle="select: nopage">(130488, DCM, "Region in Space")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d17a03b3-fbf5-4c59-9119-19ece4217f87">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f7a7c643-956b-408d-8661-e82b6ebc64ac">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0407be5e-9c2a-4a21-8da8-f2b17d0dd5cf">XOR Rows 5, 7, 7b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d9f812d5-b845-40ff-b3bd-1c73cb933744">Reference shall be to an Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fd5f5240-d71a-4019-b555-ea96643e4eed">8c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70a81489-8e21-4cb0-86bf-52e37005e8ee">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70a00bba-5aa8-4698-81c7-d6dbea8044c6">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6cf8fd49-e57e-4d47-a101-8dc194242a9a">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_31348355-bdb2-4997-9998-49296f89eadf">EV <link linkend="DCM_130489" xrefstyle="select: nopage">(130489, DCM, "Referenced Region of Interest Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_dc5556b6-e6c2-4b5d-9964-ecd6011ebb72">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6c9bbefb-b101-45bb-9fd0-d0df75eebdd5">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca66169e-8e9a-4dbe-b411-b49c1dac4344"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_93e54f29-08fe-448f-9792-be87f84517b7">Shall be the value of ROI Number (3006,0022) within the single referenced Item of Structure Set ROI Sequence (3006,0020) of the referenced Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_313a151c-67cd-49b7-846e-4d5a3e2c75b6">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4786b290-a3b9-480b-82d8-61da51f69902"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e173176-b24a-43ba-8a9d-140b3018ae55"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0cbcfa96-4ad8-476e-b1e8-383174d68dc5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6c0f3f0-30c4-4ecf-a4bb-6e5a1c86e9e3"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ea521b1d-ad15-4728-a26d-849b43104bb3"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0d9737a8-771b-4229-a641-b9f86c4feee8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a573c035-ba51-4957-8247-657d5af5f258"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b989e7e5-94ac-4903-9449-18b04d1fe108"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_36d95f7b-6c73-43b2-b6ee-9223eb679870">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9b701d26-39dd-458d-b6a9-8e15b0faf6bc">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1292851a-62f8-4527-8bad-63dc83e73420">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5af635b-0119-4333-98ce-ad385c1a9d06">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_79c684a2-36cd-45d1-a78c-1fb0a09108b2">D<xref linkend="sect_TID_1419" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_586d5703-c3b8-4005-b6f2-610ac2adcd49">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9a078511-3531-4319-a3d9-d098eb49e2db">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_185e14c0-ef5e-4430-a4e2-cd134bb822d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e7e2db6-dbbe-4010-85ee-9306c087feb5">$Measurement = $Measurement</para>
                                <para xml:id="para_f5b049f1-102c-4545-8b23-e51c438d4501">...</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4caebf43-3ad5-48d9-af9f-ed2a476c7b2c">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_49e72c1a-4079-4bfa-88ac-ad228fa0e879"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea580061-39b3-465f-99b5-3a7dded15a97"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_82c8077c-40c2-4fa6-866d-4046d268c8d8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3388ed3e-3830-4a2b-8207-3dfd497ae977"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e8a92d0b-1734-4ccf-834c-c3cb93a8c3fc"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f8c50519-92b9-4bda-88cc-1e52bbdb4e41"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_575d0ac3-3ed6-4fd8-8fc2-7e1af7ff03ec"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_061a603e-0fea-4f10-9237-dc5704af7a4c"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
            <section label="TID 1411" status="3" xml:id="sect_TID_1411">
                <title>Volumetric ROI Measurements and Qualitative Evaluations</title>
                <para xml:id="para_cbcf130c-59d0-43ea-b71c-7f7d5b19c70b">...</para>
                <table frame="box" label="TID 1411" rules="all" xml:id="table_TID_1411">
                    <caption>Volumetric ROI Measurements and Qualitative Evaluations</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_87e5605c-30ef-40ab-9e54-e5a160ac1e4c"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b792ca18-4b6b-4780-8c36-f0872b923a62">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4548b0a2-dafe-4ffe-b5ff-6f4b746b5f37">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b48ed64-9046-488b-aaab-3e437093e793">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_037bfccf-fcbf-4646-a614-7d3edd7495e1">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a4416f1f-b2da-48e2-afc1-6d1916588c9f">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8d7ea4d1-7d0f-4df2-9d64-44c4151c48a8">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9c44f7e5-e932-432b-ae62-83dc4ba5d58f">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6daad6dd-d304-4d58-b580-ab3f55ee692f">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bd991eb-9642-42a0-9c93-87848af2ac98">1</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9797c7cc-b481-4eec-8d93-ae08fb873fac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_eab96362-2bfa-41eb-9637-0bf9efdfb87c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0bcea660-1791-4428-9783-86bf458b9f04">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f2b51594-f8ef-4ee7-8448-f3dfaa51b3a9">EV <link linkend="DCM_125007" xrefstyle="select: nopage">(125007, DCM, "Measurement Group")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b8912904-0922-489a-85ba-f80c0b80db5e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_06cf9952-1268-4f7b-a9fe-915d8d26cd3c">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_91c8a03f-d2c8-4731-b118-5c6353303797"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac09d88a-4385-4f34-9717-b507f6b6dc0e"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para>...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a7f801e-885f-430a-bd16-b30d110a1688">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7af8c31f-2643-458d-8e14-dd1f3255bb05">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8a1fdf0-a434-47d9-801f-d653ef323489">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1770bfca-c1c0-4d94-afef-585287c8fab9">SCOORD</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5da4d3d-0d8e-4e1d-89ad-b0ff686e2821">EV <link linkend="DCM_111030" xrefstyle="select: nopage">(111030, DCM, "Image Region")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_ad1a6260-eebb-4362-bb5d-36a4c358709c">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1433ce9d-9be0-4b8b-9cea-fac6e2457283">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7c9f261-862f-4f4e-af48-c4991bad9403">XOR Rows 7, 10, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4e4c48-d4b8-4fd8-9916-f7c7dd6c68bf">GRAPHIC TYPE = not {MULTIPOINT}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1922085b-ae2d-417f-884e-4ad99df2cfd1">6</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a2f1b3d-4d96-46a7-9e71-8c38f1923cc6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_162b8ae0-ceab-44ad-9e45-7e2d52b8a450">SELECTED FROM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fc1348d7-32ba-4ebc-b33f-da5ab5244b1b">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_de799c4a-6157-4d21-b70f-5ceabe82e778"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f685cd2d-5961-43c7-b692-a8b66e591af8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_26d503ce-2255-48b0-bc65-01ba0499077f">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_62913662-81a3-4c89-baa3-c8f9401ddb60"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3295597b-5673-4db5-8f89-e1635d935dce"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad9a7ba2-af63-48fb-84d3-00c124017027">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99b8c5b5-8655-41ee-86e3-092c9881c82d">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3d526cd-9556-4905-a0be-00c13011cacb">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae357b28-4114-42e0-8fcd-29e6cef183f3">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9a692999-4664-4d03-b6ee-3675f3f580c9">EV <link linkend="DCM_121191" xrefstyle="select: nopage">(121191, DCM, "Referenced Segment")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4d7b8acd-9ea7-4389-939a-37b5b8127b76">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6904a646-c0dd-4765-9d3a-0efaa128d777">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c1c1ce88-c21b-4e66-acf8-2d0862590ad2">XOR Rows 5, 10, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1e016cb9-0c46-4f8b-ac6b-0d5b36b83d8f">Reference shall be to a Segmentation Image or Surface Segmentation object, with a single value specified in Referenced Segment Number</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e4f3a8f6-2d92-49e9-ab18-d1750c31f1cb">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d5942475-caf5-4b5b-8ef1-572ab8b05778">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_08d967de-4460-4233-ad43-542afda76c50">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_953ef38b-a49f-4d4e-a791-e54c13480fe6">SCOORD3D</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f1082097-4877-4b87-be85-459ec1f45e57">EV <link linkend="DCM_121231" xrefstyle="select: nopage">(121231, DCM, "Volume Surface")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_783866ce-63e0-4021-85c3-bce5be35e4cc">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f19a0a1f-c92a-45ed-b6b6-c97eced455e1">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4ee17874-ef57-4cc0-bc0d-9ba6d1365733">XOR Rows 5, 7, 12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0eabd745-2fbb-4d51-906c-a6872c0c3631">If one item, GRAPHIC TYPE = {ELLIPSOID or POINT}</para>
                                <para xml:id="para_94e71819-f1b8-4a7b-8194-f8fcf7ee244d">If more than one item, GRAPHIC TYPE = {POLYGON or ELLIPSE}</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51ce42d9-348f-4b22-a1f3-c4eeeae13aea">11</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fbfdbb5f-2399-48cd-8a37-27cfd3ac93e0">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9ef769a4-b036-488a-9617-cbe524d65743">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_582c8232-dcd5-4aab-813e-3258dbc8f13c">IMAGE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5041208f-c5d5-4906-87d1-92f4610d7f08">EV <link linkend="DCM_121233" xrefstyle="select: nopage">(121233, DCM, "Source image for segmentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6e888005-191c-4f37-b69d-091f05b75823">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fb51dcec-c372-4680-82e9-f14a4617538d">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba907fb4-8b79-43d3-99fd-ab6d5d47c208">XOR Row 12 and IFF (Row 7 or Row 10)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17aefa54-5d49-42ca-b9e7-7e736ebbdcb0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4330498d-5af9-47c5-8d78-bb4b0e579616">12</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7513186f-31e6-40c3-b827-b4ea1a357362">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b970e94e-0c56-4720-96dd-6aa4ba1b692f">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_277a3bf0-2f46-4870-9fad-39c31f5ce53b">UIDREF</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_72cde9df-be57-4d02-829c-edb25d574bb5">EV <link linkend="DCM_121232" xrefstyle="select: nopage">(121232, DCM, "Source series for segmentation")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0c538e29-5818-47d8-8bae-7a89ce13b8e3">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_41bc29f5-d975-4822-ab35-33cc8a34c59f">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f394ce81-6558-4814-8ed0-59cf7e54df6c">XOR Row 11 and IFF (Row 7 or Row 10)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87e310ad-ee4f-4cbd-8478-4f33ad28764a"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_026142bd-1b96-43b3-9fa7-5ef906f2e44e">12b</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e0c211e-23fa-4bc4-89b1-8e2d974f0b80">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_04c479b3-8c48-4a0f-8310-b96e2eb3edb3">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_229ae1b0-d2ef-4e07-a0ea-2e8300149966">COMPOSITE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_37eb8fd6-d6f3-4a43-af13-26dff45fc87b">EV <link linkend="DCM_130488" xrefstyle="select: nopage">(130488, DCM, "Region in Space")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_4bde3c3c-797b-45a8-8868-d92d7b8f5dfe">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_357916d4-ba30-46f4-a80d-2ea071ebf7bb">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4b7aa33a-4e13-4f8b-be70-7934d3981840">XOR Rows 5, 7, 10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51c774e1-b1af-48f1-86f9-64de98cd96c4">Reference shall be to an Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f4cc6c43-857f-4eae-9830-556b1b3a0b42">12c</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_df8e6f35-cf75-4f20-8b86-3801f7ff2b91">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8d72e83e-ab41-447d-9cda-cb691df53bad">HAS PROPERTIES</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34521067-a172-4ade-9c49-5e155a53a14f">TEXT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0c28a9bb-13d4-4819-849c-1f8374f179e0">EV <link linkend="DCM_130489" xrefstyle="select: nopage">(130489, DCM, "Referenced Region of Interest Identifier")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1370b14-71c0-4814-b84a-83a5819f59cf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e49c9696-fce1-499d-9225-2917c5f456a8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c7e4168e-34dd-4e70-b928-67683d7c202e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_06f4fe38-f432-414d-a359-ff91b3050c3c">Shall be the value of ROI Number (3006,0022) within the single referenced Item of Structure Set ROI Sequence (3006,0020) of the referenced Instance of the RT Structure Set Storage SOP Class.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48d6906f-d64b-47a6-a3a4-c6b1d2a8e17f">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d65bfe21-f6b6-433a-9868-8eee64a57b2b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_19f678da-627c-4265-a695-4a07c9981220"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bed1f32e-09b6-4083-8f9a-87d8c997f7df"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7de6d9e4-466b-40ca-9eb2-57050058b0e2"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_081c16d4-8759-4063-bb24-f86082716b96"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86df942c-5ae8-49ae-a72b-1d2f03d42485"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a8ee2840-b2c0-4b64-8d2b-fd4331239381"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4c9c4835-8892-4926-b8a8-16974eae8e20"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c54c872d-f10c-4078-8c7c-27bb9c21222a">15</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_455b7c37-144b-4a4e-aa73-97b9a27fb368">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_847063e9-4610-4854-8f38-979aa2385acf">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a7ad7351-3cd4-41d6-a7b7-172abbabe0d5">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_35053229-c6bc-4181-97ec-3091075c745b">D<xref linkend="sect_TID_1419" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_fdb8a177-b3ab-4af3-8b48-0035174dbb3e">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a2032be7-d5b5-4b47-a512-d048d0c26016">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_213933d5-6479-40a8-8407-8ceeb9f5ebd9"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1655d89b-3fe8-4f78-a2f9-3fb462b2686c">$Measurement = $Measurement</para>
                                <para xml:id="para_f6bcefcc-d5db-45eb-8707-f6983d38f79c">...</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_cbecefcc-eed8-4a03-be3c-4a4cdf6e398d">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6538d3cd-1704-41e4-a47a-8cc196767503"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_28fcb122-6814-4b6f-a838-3f76306160ac"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c51ff375-58c0-4c27-b9bb-2f25ae9236b5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b640c7dd-0666-4a6a-aee4-5b8a6c5ba533"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_08e7ea18-47f6-4be9-b39e-11a58b88d2cf">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c061bd5e-0509-40df-a552-9022c6ac90eb"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4133ea51-9f6a-494f-93b3-3423344cfa18"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7f3fad43-8fce-4abe-86fe-dd440d082366"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        <section label="TID 1419" status="3" xml:id="sect_TID_1419">
                <title>ROI Measurements</title>
                <table frame="box" label="TID 1419" rules="all" xml:id="table_TID_1419">
                    <caption>ROI Measurements</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_12836944-553d-4d38-87cf-18a10f4027ec"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_46517370-7769-4cdf-86c6-7aa492dce62e">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_14515a82-f650-424e-9e85-f2ad8e617f3d">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_584e0384-4e44-48b5-b820-cae6f89883d1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_8724753e-a9bf-4505-bfac-cbe35b18ebd7">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_24ee3e66-d99f-43cc-b1ec-cab5e2af1d1d">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5514d345-0451-4361-bcbd-1ab9d403eca6">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_35905e7d-015f-4650-abc7-c4f3882b808a">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_613db39e-b4fd-4834-9441-3726f59ac635">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ae7b9269-2ca6-4552-99b4-f2f15c58e179">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5a3e9de5-1c2f-4741-b492-d06585fb1730"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9eaf09fa-7ce0-4a4a-91fa-bcce52a71005"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b3f687a3-341f-4e27-bdae-8e1ac620a4ad"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fb22d47c-a08d-40b6-b3a3-05e66fc56fdc"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e7120133-6db4-4377-8edf-a4d5b927e51a"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c3f244dd-073e-4e7b-b05d-1215e3d1f55b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2887134c-e284-416f-8d36-4f558fbededf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8b83b65c-fa42-46a3-bab9-2efb92d1dc03"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42dae226-407f-46d6-990e-4a3856d5dc2c">5</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3575aa5e-eba5-4a0a-9e81-7c84db2cfdb5"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3fd739c-416d-481b-8a3f-894f2e240d0a"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f540b40-5ed3-4a2b-aeba-aacba2b72a7a">NUM</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_451f249b-f32e-452c-b341-b9c68d09a547">$Measurement</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6ca4a420-efd5-48a5-9a61-2b9bfc954a82">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_1f6fc21b-ac48-4e10-a7ea-d44dd68f0ea8">M</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8e7af36f-02f0-4ae7-9a77-7102cc7d851b"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d7afdc57-827c-4ac5-9c2b-5ce3c6ddebd7">UNITS = $Units</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7b85e119-679b-4716-b873-b3938706de2e">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d0360226-e798-4c57-98e3-c0227a1904bf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4d4ea7f5-02e2-4e4a-8d95-172c68048ec3"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f09bd16e-6c86-4719-bcce-af1bcd7efacd"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69f80ec7-f182-4ee1-b80f-48d4616ebb42"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7ab28def-a137-4fbc-a8e7-7954a74dba88"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d2c2e35d-0ed3-42d1-9eb4-26394898748c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bdaa55be-7339-4e00-96bf-f2dcb26497d7"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_565d3344-f84d-43fa-a753-12479c89cf3b"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        <section label="TID 1500" status="3" xml:id="sect_TID_1500">
                <title>Measurement Report</title>
                <para xml:id="para_451fd560-e4eb-4e0d-bbbe-a2b2bc35cfdb">...</para>
                <table frame="box" label="TID 1500" rules="all" xml:id="table_TID_1500">
                    <caption>Measurement Report</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_7f96ef72-3739-4709-a6f5-d3c609e4ec05"/>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_eb663436-d709-454e-ac93-98682212c9f0">NL</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_6142a93b-0f6d-44a4-8494-fc3299ba7c21">Rel with Parent</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_81a6fa58-162c-4816-971a-d0a224744ee1">VT</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_97622db7-889d-46d0-a1c0-605bfed0f4c7">Concept Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_feb517dd-7464-42f5-9f1d-496753de6be4">VM</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_220e6ae8-5f33-4f58-b426-f41cd8fd2bf4">Req Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_9af3785d-8f23-4d07-809d-5639784468c9">Condition</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_80f6672b-b0af-4725-adc3-e4e8c7e83695">Value Set Constraint</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3321887d-8899-4314-b289-3d0e04bcdf8f">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_fe0e84e0-be0d-437f-8baa-f2478513e5ee"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d8ae3ff8-c9ea-42bf-96e0-2414f44efbcf"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_85dac8a4-19f9-4283-bd59-d51aa905412d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6e81e20b-a511-403a-893f-29ce62ab8e77"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_5b5a81ce-2cb2-47bf-9730-858f4fea4387"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0b360053-7fdd-4be5-91bf-eaea1c56d55d"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ca0229a7-7804-4c95-b314-b59248fade6c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c53c5359-96e3-44c4-8875-94dba07faea0"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_96d6cfbb-9f8d-4203-92f0-dc6f05c2d0a8">7</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6ef2d231-13a5-4959-a821-9506f815bff7">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f15deab-dd23-4d60-83de-dd6a73b90078">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7ce9f59e-0b11-4f3a-aa05-a88e1aa9c1ae">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_77bd714c-3790-436e-8fde-280daf9850b5">D<xref linkend="sect_TID_1410" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_a9103603-6261-4637-b46b-fa22134536fe">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15f776e2-a5af-4ee4-8902-8d861d3932b7">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d25704ea-5734-4683-8a36-210409afacf8"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a87b6e4f-bced-4eb7-85ca-72f7b53d423c">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_378db2d7-b6b1-4bd5-bd55-3ecc1936deb9">... </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_237b4895-3ec5-42f6-83d7-ca4b9914ce10">8</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_34b0264b-6367-41ef-9ab3-ac6f73e5a926">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_edd197ad-42e1-4181-b741-9f29a3ca83f8">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_38ae7415-a014-4b38-bba5-90c84f6d89c9">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8276a87d-183b-4ec0-9de3-c5b2ec064c57">D<xref linkend="sect_TID_1411" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e654f7db-b58f-4a0c-be26-9679fe2714ed">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d0a9eb71-ba77-4b3c-92b0-20807066566c">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_637e45d6-6eee-4f3f-9ce5-fb5d384ae031"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a2b0eb06-c798-4882-abec-a2632ac19b44">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_d952336b-31c3-4a64-a013-7ff63702a47c">... </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e00ee47b-e07a-4063-9295-f00b8f902998">9</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_75af0046-0485-49d9-8863-6ce205f822c6">&gt;&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_aa985cec-610b-4445-b7f1-2ebbab06936b">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51feb8fa-c5e0-46a7-afcb-b82dc0f31423">INCLUDE</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_afa5de9d-884c-4de6-8af3-0f259624c15e">D<xref linkend="sect_TID_1501" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f0cc25ff-0ec1-44cd-a6c4-4ba948d2a1ae">1-n</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2c07259d-38bc-4ccd-94bd-f6802ad60bf1">U</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87d9dd51-a193-4405-b81d-59c4610661d1"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_17c5d93d-3fbc-4a4b-9dc6-71a477409861">$Measurement = B<xref linkend="sect_CID_218" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </para>
                                <para xml:id="para_1bd79cf9-8707-403a-bace-11f90ec0738c">...</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f35f1012-6565-4615-94b4-a578329d628c">10</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8ccf6dc7-6bfa-4c00-a480-e01762c81728">&gt;</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bddc1cb2-753b-4cfb-afb9-4e7d0a9a5b88">CONTAINS</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_20defab9-20a6-4f11-8d8d-5dc3d112bce6">CONTAINER</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_41dd250a-8b5b-4dbf-8841-b031757426a3">EV <link linkend="DCM_126011" xrefstyle="select: nopage">(126011, DCM, "Derived Imaging Measurements")</link>
                                </para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_22a0c72b-ee47-4b01-8193-4fccee14c0f8">1</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_86f3c834-9d4e-457b-9727-a65324c488fe">MC</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_30d76f5b-1438-404c-8012-2bfb78dc0bc3">IF Row 6 and 12 are absent</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87acdb58-5f9a-4c02-b01a-4e3975a65b68"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f8fe61e3-72f2-4b02-a51c-44563b59b978">...</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8a4a34a9-de6f-44df-95fd-435be79807e2"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1ca08070-3f41-4ae9-a44a-f5aef6842373"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_892802bf-81ec-4bf3-a07c-b186deb68678"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ae0e1a3-84c0-48d7-bc70-696f1f329c73"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_748bc817-c27c-40de-b5e3-487af83b9d15"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_37a35928-b507-4371-9ec3-26ab54918680"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3496ac24-599c-4c88-8589-a7357a4e0d1e"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_5f83e70c-e942-4ffd-b5de-05054b8ef981"/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>

        <section label="TID 310" status="3" xml:id="sect_TID_310">
            <title>Measurement Properties</title>
            <para xml:id="para_b202a14b-10bd-4c3a-bec3-c10413e1452d">...</para>
        </section>
        
        <section label="TID 4019" status="3" xml:id="sect_TID_4019">
            <title>Algorithm Identification</title>
            <para xml:id="para_015009ff-a410-4480-9bfc-77e1e28f190a">...</para>
        </section>

        <section label="CID 226" status="3" xml:id="sect_CID_226">
            <title>Population Statistical Descriptor</title>
            <table frame="box" label="CID 226" rules="all" xml:id="table_CID_226">
                <caption>Population Statistical Descriptor</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa62690e-6cdd-4e2f-b623-5a00ee91b287">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_50a1dbc3-4385-49a1-9cc8-309d664b27d9">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d68d1d85-ea6f-415b-89a5-f82123456867">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4c614cd5-ebac-468f-ba9d-be045a94d45b">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8bd55fa0-fc47-4b84-8830-dc17a99a3fd6">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_32267f7d-818a-4c54-b509-32250f751919">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_662abcc3-7849-4eaf-ba73-5212568ac9b3">
                                <link xl:href="http://snomed.info/id/371889001" xl:show="new">371889001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f5635929-e39a-400e-9074-ced9ace6cab9">95th Percentile Value of population</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0db5dd1f-30f1-4274-900d-7edea8979137">
                                <link xl:href="http://snomed.info/id/371889001" xl:show="new">R-00337</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c9a7a0fd-3382-4df2-ac30-7a452acb3cca">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1299358" xl:show="new">C1299358</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_acddadb6-6586-427b-b666-de53a0b100b4">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4ce37e07-f468-4b59-9b47-e642a9d52355"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8993684b-b088-4978-b480-91f03bc92699"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9917046a-5f81-4b8b-9243-51d8012d5c87"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1dc3ac18-5d24-43a5-be88-cc7fdeee7c43"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="CID 227" status="3" xml:id="sect_CID_227">
            <title>Sample Statistical Descriptor</title>
            <table frame="box" label="CID 227" rules="all" xml:id="table_CID_227">
                <caption>Sample Statistical Descriptor</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_942d3e9d-73e4-480b-bc4f-48010580a73e">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb6002ef-671b-4608-b411-c41f6fbb095c">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d07fd75a-d00f-49ea-8c9f-e081163433e1">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9aad5c30-a304-48e5-8776-a2ab6f970745">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0aaa29f4-3f25-4e4c-9edc-ee83ef932252">
                                <link linkend="DCM_121415" xrefstyle="select: nopage">121415</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e7d86ac0-4902-4d47-90a6-fd0df4b00f15">Percentile Ranking of measurement</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d76b36ca-aff5-4422-8103-a14169c45361">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2fce3ff-c16c-4328-95ba-1c3a22678c14">
                                <link linkend="DCM_121416" xrefstyle="select: nopage">121416</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1af368e7-54f4-48d2-9057-375c391b9ff8">Z-Score of measurement</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 218" status="3" xml:id="sect_CID_218">
            <title>Quantitative Image Feature</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a2bab1dc-184d-485d-b9fb-f8e27a47ecfc">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_218.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-218-QuantitativeImageFeature.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-218-QuantitativeImageFeature.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1269.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2a6d5582-6c8b-4831-ad70-b8c020214472">
                            <emphasis role="bold">QuantitativeImageFeature</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_990da649-06e0-47ff-9a92-49ac47647203">
                            <emphasis role="bold">dicom-cid-218-QuantitativeImageFeature</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_a646ab0f-a25b-438a-9782-0e8a50a97bf5">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6e7d7d34-d49c-4ab3-87e5-29cf530458b2">
                            <emphasis role="bold">20200920</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_635c2ffc-1539-4753-9ad9-364a30b56d0f">
                            <emphasis role="bold">1.2.840.10008.6.1.1269</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 218" rules="all" xml:id="table_CID_218">
                <caption>Quantitative Image Feature</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_db9b8522-643e-499d-b954-556e108f0f3b">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_411434a9-beb0-4491-a58d-c8256f1d9911">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2034efa-0792-43df-83e0-971c0b52a939">Code Meaning</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_dd17c90b-fd05-4593-8a9d-8d10d312cbb6">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7468" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_bbb76df2-d60e-42e7-b5e1-166d1b9f47e4">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7469" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_1bb6ce95-2aee-43c2-91d9-0a902dfb923f">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7477" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="3" rowspan="1">
                            <para xml:id="para_3acffde8-179c-468b-89e4-7d518198c0f4">
                                <emphasis role="italic">Include <xref linkend="sect_CID_7550" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
    </chapter>
</book>