<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2356</title>
    <subtitle>Add Ethnic Group Code Sequence</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/11/16</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Ulrike Wagner</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/03/14</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2356</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Ethnic Group Code Sequence</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3, PS3.6, PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The ethnic group or race of a patient is only described as a text string rather then a coded concept, when there are well-defined coded concepts available, as used in SR. Add a code sequence attribute.</para>
                    <para>Note that in DICOM the concept "ethnic group" is used in a general sense, and is equivalent to the social construct of a group, <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://snomed.info/id/415229000">SCT:415229000 Racial Group</link>, and not the US-specific <link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://wonder.cdc.gov/wonder/help/populations/bridged-race/Directive15.html">US OMB Directive 15</link> (Hispanic or not) manner.</para>
                    <para>Also change context group reference in SR subject context from Defined to Baseline, to allow other codes to be used as necessary.</para>
                    <para><emphasis role="italic">[Open Issue: Should more than one Item be permitted to allow for more specific description of mixed race?]</emphasis></para>
                    <para><emphasis role="italic">[Open Issue; Are there HL7V2 fields and FHIR elements for this that correspond and/or value sets.- e.g., see US extension.]</emphasis></para>
                    <para><emphasis role="italic">[Ed.Note: Also change C.13.2 references that should be to C.2.3 Patient Demographic Module rather than C.2.2 Patient Identification Module where appropriate.]</emphasis></para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
                
        <section label="C.2.3" status="3" xml:id="sect_C.2.3">
                <title>Patient Demographic Module</title>
                <table frame="box" label="C.2-3" rules="all" xml:id="table_C.2-3">
                    <caption>Patient Demographic Module Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_2f485598-511d-492e-a3c7-79bfdd81ce68">Attribute Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_523b87fe-c055-4338-9cb9-ff0cf657b37e">Tag</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e435214b-d609-43f9-be65-c66cd7d255ef">Attribute Description</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9bc6680c-befc-4fbb-b598-f38cd006d6e2">...</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_19cb32a0-0a70-4d9e-89f2-bb5991d80b03"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1d9c8bed-5a01-4e96-9e19-5f020061b6b9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a6ea0f92-5321-4fc4-9779-e52e3f5afb37">Ethnic Group</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_d050d530-cd2a-4164-abf4-5edbf90dde9c">(0010,2160)</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ac3b855e-33c7-4b46-840e-0f0f4268a8a1">Ethnic group or race of Patient.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Ethnic Group Code Sequence</emphasis></emphasis></para>
                            </td>
                            <td align="center" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">(0010,eee1)</emphasis></emphasis></para>
                            </td>
                            <td align="left" colspan="1">
                                <para><emphasis role="bold"><emphasis role="underline">Ethnic group or race of Patient.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                            </td>
                        </tr>
                        <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">B<olink targetdoc="PS3.16" targetptr="sect_CID_6099" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1">
                                <para>...</para>
                            </td>
                            <td align="center" colspan="1">
                             <para/>
                            </td>
                            <td align="left" colspan="1">
                                <para/>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        
        <section label="C.7.1.1" status="4" xml:id="sect_C.7.1.1">
                    <title>Patient Module</title>
                    <table frame="box" label="C.7-1" rules="all" xml:id="table_C.7-1">
                        <caption>Patient Module Attributes</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b3c32db2-8602-4023-89bb-3856b3c51c8e">Attribute Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2f7d731b-1fef-4474-81fb-bd2eb47efb40">Tag</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8d036e51-8ab1-43d3-8460-77d97c7a5ff9">Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_53c874ba-0179-437b-86d0-406e872b2065">Attribute Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5bf1f026-8432-4ae7-b5cd-1935b608d4cd">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_353153a4-93d9-455d-9cd3-4f9c0e6e5c3a"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e4638255-baff-4e4c-aa74-ed52d49beb0e"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_427a23ce-994c-4eb2-9cab-0c07583ec129"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1f7608c5-0f7c-4762-9200-04a602f2cb06">Ethnic Group</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a0c22dd7-0ab0-49a0-95e2-6c0c472d780d">(0010,2160)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_79cb0f04-62bc-4b14-aaa0-21280ba10032">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b9146e82-c7a9-44ff-9775-e0d8482195dc">Ethnic group or race of the Patient.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Ethnic Group Code Sequence</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">(0010,eee1)</emphasis></emphasis></para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">3</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Ethnic group or race of Patient.</emphasis></emphasis></para>
                                    <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
                                        </emphasis></emphasis></emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">B<olink targetdoc="PS3.16" targetptr="sect_CID_6099" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis></emphasis></emphasis>
                            </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_76c086db-a2d6-4fc4-a972-aa17309cb654">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ecc4b464-145e-41d1-a0f7-1da3f3b132f4"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1ce2285f-6014-4620-a482-683a4f86bc21"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f4631c33-1fec-4136-841a-72846b2899fa"/>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
        
        <section label="C.13.2" status="3" xml:id="sect_C.13.2">
            <title>Basic Film Session Relationship Module</title>
            <table frame="box" label="C.13-2" rules="all" xml:id="table_C.13-2">
                <caption>Basic Film Session Relationship Module Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7972c820-2467-4aa4-bb80-548f30f88d84">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82e34827-47ad-43df-bfe8-3b3630e1b60c">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f857f4f1-69c0-4157-89c3-5721d88d9662">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8b1ef631-8796-4338-a741-2b236a88da7c">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7dd50da6-b5db-43e8-9355-71d2a847d477"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_28c9b1d6-a2b9-4ae8-b64d-a04dbd5ffe06"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_a8f0aad0-ed3d-4304-adf6-d31a906fb442">Proposed Study Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7935f665-6ff7-4489-ab21-6dc55dfb6f3d">(2130,00A0)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f0f4d56f-1af1-4602-b51e-30e6d2041a27">Attributes that may be used to identify and describe the Patient, Study and Series that are the subject of this Film Session.</para>
                            <para xml:id="para_b42eff0c-d7bd-4a54-8901-33ae5b3f2ebc">Only a single Item is permitted in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fae14a11-0c4a-4189-9e94-6ae385e68a90">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ae8f0361-9d88-45ba-b449-a455f257ff45"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7c1c5009-0c9f-4c16-a1a8-85f1ab0df66d"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_776a3d76-61c4-462a-b629-35bcdd194fc5">&gt;Ethnic Group</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_62e268ad-c2aa-46cd-8370-b13e5d568e9c">(0010,2160)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_46e55cc1-b077-408c-956a-bd4002a0c25e">See <xref linkend="sect_C.2.3" xrefstyle="select: label title"/> for description.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ethnic Group Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,eee1)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">See <xref linkend="sect_C.2.3" xrefstyle="select: label title"/> for description.</emphasis></emphasis></para>
                            <para><emphasis role="bold"><emphasis role="underline">Only a single Item is permitted in this Sequence.</emphasis></emphasis></para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="2" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">&gt;Include Table 8.8-1 "Code Sequence Macro Attributes"<!--<xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>-->
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">B<olink targetdoc="PS3.16" targetptr="sect_CID_6099" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ce742bb1-e81a-4784-aa3e-0ce6ecf02147">...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9922b9e1-891e-4031-88c3-5e047bfbeaa1"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c4b79dd2-914d-4bba-80dd-04b351e43395"/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Add new data element to DICOM PS3.6 as follows:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="6" status="1" xml:id="chapter_6">
            <title>Registry of DICOM Data Elements</title>
            <table frame="box" label="6-1" rules="all" xml:id="table_6-1">
                <caption>Registry of DICOM Data Elements</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3e8c52d5-3582-4ec4-a7e6-acd7604caf32">
                                <emphasis role="bold">Tag</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ac298c3b-bcdd-462b-9240-c38e738bfb7c">
                                <emphasis role="bold">Name</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_99f6b0ff-e1b0-484e-83b5-c3003d61704c">
                                <emphasis role="bold">Keyword</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42b3621d-8b30-46eb-8992-10bb21310ac7">
                                <emphasis role="bold">VR</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_551ea829-a949-4bfd-a201-bb102024e64c">
                                <emphasis role="bold">VM</emphasis>
                            </para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a18713f-2e81-4664-b9a1-e4e3d41957ab"/>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c36579f-3dad-4b41-9f0a-b488d9a5be90">(0010,2160)</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_96279fc7-e8b4-416c-af6f-ced7cdd4a031">Ethnic Group</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1693d091-2a4b-47c9-85f6-61fb6bbdcb6f">Ethnic​Group</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_390361b5-9b5c-45d4-9004-a99dac2e2749">SH</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82f0863f-ea57-4b67-9cd3-d285d7ce67fa">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f5e29409-1c72-4a74-b8e2-82a6a7bfa68a"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">(0010,eee1)</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ethnic Group Code Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Ethnic​Group​Code​Sequence</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SQ</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">1</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline"/></emphasis></para>
                        </td>
                    </tr>
                    
                </tbody>
            </table>
        </section>
        
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text are bold and <emphasis role="bold"><emphasis role="underline">underlined</emphasis></emphasis> for additions and <emphasis role="bold"><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for removals):</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        <section label="TID 1007" status="3" xml:id="sect_TID_1007">
            <title>Subject Context, Patient</title>
            <para xml:id="para_bf468c38-5fec-4320-bd23-8840a4b99ee7">Identifies (and optionally describes) a patient who is the subject.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_60f651c1-5481-4ce9-a8a3-9bcf147ecfe3">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Order:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_fbe8f43d-9364-4b4f-9949-0b5a3110768b">
                            <emphasis role="bold">Significant</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Root:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8f9a9b30-f845-4b70-a55f-f356cf574eea">
                            <emphasis role="bold">No</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="TID 1007" rules="all" xml:id="table_TID_1007">
                <caption>Subject Context, Patient</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cbfaf626-9734-4d07-a4ac-0aa6958258c5"/>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3a036833-b7d7-41eb-917b-2ecdcf0d995d">NL</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_901af82f-5f12-455e-96dd-d7660580d658">Rel with Parent</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b7de8b7-7530-475a-87e6-8787224443c7">VT</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aea81ac1-0ded-411c-94bb-f9a48e915cd0">Concept Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9b38dad8-5e65-4e44-9911-505877fa176d">VM</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_80064aea-6c47-48ad-8ebf-a4926020a288">Req Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9af8b701-1cde-485e-9275-6909874ce303">Condition</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6162a781-0873-4597-824f-bdf777429be7">Value Set Constraint</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8019b492-1fd1-44e6-8732-c7f765778080">...</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3192be22-006e-47b0-9272-80f0d842378d"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_fb168607-e8f0-4e62-8c96-ea881d809fdd"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e45ac586-76fc-443f-87ec-7ca703334271"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_5ab0ba85-5b97-4079-8945-aac23bdf520e"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44eec935-d3b5-43ee-95ce-62dec7662df9"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d64e418-4e74-42cb-8db6-00481b9fd2bf"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bcb64d08-0f26-46fc-b46e-5b47975537db"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_cd49e539-941c-4ec0-9ca6-b4094b8e8ea5"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_244187c3-3e03-4f1c-bced-a23bf7b02956">9</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_199ae9a5-2b85-425f-a4a5-b3e5170e32da"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c8c2b899-f437-4160-a4ed-6d2b1d0fdea8"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ae38d44b-07c4-4ca7-a8d6-87dedec09304">CODE</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_001845b6-e368-4f4f-bfa6-92a8cb4ed4c8">EV <link xl:href="http://snomed.info/id/415229000" xl:show="new">(415229000, SCT, "Racial group")</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d68fd13c-389e-49f3-8a6b-0ae19e59b592">1</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2c2aa631-9941-426b-9cca-2f3473987b98">U</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bd544c37-f3b1-4262-a145-833c83ea61f0"/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2c234fea-fdfd-40c9-93a3-8b07ead0a6fe">Defaults to <emphasis role="bold"><emphasis role="underline">Value of Ethnic Group Code Sequence (0010,eee1) of the <xref linkend="sect_C.7.1.1" xrefstyle="select: title"/><!--<olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>-->, or if absent, </emphasis></emphasis>
                                the coded equivalent of the text Value of Ethnic Group (0010,2160) of the <xref linkend="sect_C.7.1.1" xrefstyle="select: title"/><!--<olink targetdoc="PS3.3" targetptr="sect_C.7.1.1" xrefstyle="select: title"/>-->, which is defined as "race or ethnic group"</para>
                            <para xml:id="para_296466ba-c231-41b5-8108-fba2584de6d7"><emphasis role="bold"><emphasis role="strikethrough">D</emphasis><emphasis role="underline">B</emphasis></emphasis><xref linkend="sect_CID_6099" xrefstyle="select: labelnumber quotedtitle nopage"/>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged, PS3.16:</emphasis></para>
                </td>
            </tr>
        </informaltable>        
        
        <section label="CID 6099" status="3" xml:id="sect_CID_6099">
            <title>Racial Group</title>
            <note>
                <para xml:id="para_27a9db3c-3467-4d70-a48d-946d65d581c9">This Context Group is intended to be a set of values that is the union of concepts used in various jurisdictions. It does not distinguish race from ethnic group.</para>
            </note>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_58962cb7-6c55-4636-8c1d-7514e4b4fbbe">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6099.html" xl:show="new">HTML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-6099-RacialGroup.json" xl:show="new">FHIR JSON</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-6099-RacialGroup.xml" xl:show="new">FHIR XML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1278.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_2a3cafb1-d1dd-46ea-94cd-4e50b216d9a8">
                            <emphasis role="bold">RacialGroup</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_7181b9e3-7e7a-4cd3-b8fc-adede2667c17">
                            <emphasis role="bold">dicom-cid-6099-RacialGroup</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_95a353fe-841e-4263-a40b-7f89b046d0e8">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d113e7ce-bd7a-4a30-aa23-9bea963c7e8c">
                            <emphasis role="bold">20201115</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e0dbf00f-735d-47c9-8663-de012bcb1aab">
                            <emphasis role="bold">1.2.840.10008.6.1.1278</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 6099" rules="all" xml:id="table_CID_6099">
                <caption>Racial Group</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1aa4a60c-9d65-41a4-ac82-ba82d1035833">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_147cb3d4-e22e-401c-8c9d-772024012b9a">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cf7e1edb-3356-4b77-858a-275e81d3e45a">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fef09a07-9652-4b16-925e-9e13016cf548">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_65915413-e913-438a-9319-3dafcf365832">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1b7df7ec-5bef-40db-b6dd-feb9e528756d">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_171a36c6-b841-454d-a0c3-45cfdfd6a151">
                                <link xl:href="http://snomed.info/id/413464008" xl:show="new">413464008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b97ccd0a-8a39-4410-aefc-b25c2b1052b0">African race</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_42de4af1-5319-4e28-a4d6-0f0c382c7bed">
                                <link xl:href="http://snomed.info/id/413464008" xl:show="new">S-0004E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_baff6e1c-a62f-4040-80e3-1a004e730494">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0027567" xl:show="new">C0027567</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66ce4569-1deb-45fe-b1fb-381b1f270f94">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6f2b5379-a3f6-4d92-8d60-e701ecf2f035">
                                <link xl:href="http://snomed.info/id/413582008" xl:show="new">413582008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_9f440c3d-8d11-4711-94f3-35fd64826314">Asian race</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_03480f6a-386b-46f8-ad9b-b571b2cace86">
                                <link xl:href="http://snomed.info/id/413582008" xl:show="new">S-00051</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e87bd2f6-6cd7-4554-a459-783655bef9d8">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0078988" xl:show="new">C0078988</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_20c3c10c-5db0-4046-a1d5-6b9661c08f59">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eeeda8af-eb47-473c-a618-060632098ef9">
                                <link xl:href="http://snomed.info/id/413773004" xl:show="new">413773004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_683bd777-687e-40ff-927b-648dbe1f4788">Caucasian race</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3cdba906-2bf8-4797-a33a-352dbac3f5f8">
                                <link xl:href="http://snomed.info/id/413773004" xl:show="new">S-0003D</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d982a7ab-dd97-4f61-b3e1-617ddbbc77d5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0007457" xl:show="new">C0007457</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_13e145ea-e546-40a1-9819-3fbc189107ff">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8d0b58a5-206c-49c8-b54d-efe0e76f730c">
                                <link xl:href="http://snomed.info/id/413490006" xl:show="new">413490006</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_1670d8a4-4cb6-438d-8060-8353332f6901">American Indian or Alaska native</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ff0f7ab-58e5-446c-8c5d-11f58f5c20f6">
                                <link xl:href="http://snomed.info/id/413490006" xl:show="new">S-0004B</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cc492226-4bc7-40d1-bd43-7ba23bacfbb5">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1515945" xl:show="new">C1515945</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b8a8a629-f55a-49b3-a552-867b01e55ede">NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94eed133-0241-4b88-9594-faec9d245991">
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;ns=NCI_Thesaurus&amp;code=C41219" xl:show="new">C41219</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_762dab77-53b7-4b99-98e2-041bb88124ad">Native Hawaiian or other Pacific Islander</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_861ace95-1ad9-4ba6-bcf2-a4b813aa7b26"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4dacf13c-8f1d-4070-b58d-eb352993221e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1513907" xl:show="new">C1513907</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c1d235d-7e50-49b2-ad02-e3a9da2b6e96">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4b36765b-78fb-4e32-a767-40c96d02f217">
                                <link xl:href="http://snomed.info/id/413581001" xl:show="new">413581001</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_70084131-80f6-4b5a-8626-1252a769e3ef">Asian or Pacific Islander race</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1909f60c-4e17-434d-aa8d-a821c89dfb04">
                                <link xl:href="http://snomed.info/id/413581001" xl:show="new">S-0004C</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fc752c74-3efd-4b19-ab18-f3a9e0d8acbe">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1531604" xl:show="new">C1531604</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_110d5b8e-0733-4096-b7df-3d097cf93503">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0808d906-de10-4253-94d6-530d6fd9a8d6">
                                <link xl:href="http://snomed.info/id/413600007" xl:show="new">413600007</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_349f0c15-d549-4063-8f15-8a261773b9f3">Australian aborigine race</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_56bf2c38-154e-48ae-9ecb-cb71e4cc8461">
                                <link xl:href="http://snomed.info/id/413600007" xl:show="new">S-00052</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29b49ce9-e504-4dc7-9d8b-8010ff2f9884">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0337948" xl:show="new">C0337948</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9c1388c5-ff11-4f56-a3f2-f2ec3f259d05">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_bf9d913d-daa1-4ea0-9cd4-0f13db1500e6">
                                <link xl:href="http://snomed.info/id/414481008" xl:show="new">414481008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_8f1e7781-27ea-471d-9104-fbb42f36ed92">Indian race</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a1cf3459-1170-4f99-90da-c71cc5bb28b6">
                                <link xl:href="http://snomed.info/id/414481008" xl:show="new">S-0003E</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d06d222d-3223-4b64-9ab7-9b4476ce9f86">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C1524069" xl:show="new">C1524069</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b49de16e-7d12-4d0b-9eb3-3dcf01dd7453">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0dba2368-8d47-45af-b590-2b86b7320504">
                                <link xl:href="http://snomed.info/id/414752008" xl:show="new">414752008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_85722c9a-eafd-4727-a02c-ec235bc48bee">Mixed racial group</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66097b2b-9e18-4506-81c6-b1375e99631e">
                                <link xl:href="http://snomed.info/id/414752008" xl:show="new">S-00043</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d6c4089-de88-4c28-9d81-38314ca93d08">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0682081" xl:show="new">C0682081</link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
         
</chapter>
</book>