<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2330</title>
    <subtitle>Add Spatial Information to Secondary Capture IOD</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2024/01/14</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/07/26</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2330</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Spatial Information to Secondary Capture IOD</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>CP 600 added the Pixel Measures, Plane Position and Plane Orientation functional group macros and the Frame of Reference Module to the Multi-frame Grayscale and True Color SC objects, for use cases that generate information as a result of processing that is not modality specific and often contains color information, but which to be useful requires preservation of spatial location information in a 3D patient-relative coordinate system. At the time, it was thought that it was not necessary for CP 600 to extend the traditional single-frame SC.</para>
                    <para>It has become common practice to use a Standard Extended form of the traditional single frame Secondary Capture SOP Class in a similar manner to the CP 600 approach, particularly for those applications that create very large individual image frames (e.g., of photographic size), so this CP proposes adding the Image Plane and Frame of Reference Modules to the SC IOD. This provides symmetry with the capabilities in the traditional single frame CT and MR image IODs.</para>
                    <para>Ideally the Frame of Reference Module would be added as conditional upon the Image Plane Module attributes being present, however this might invalidate some existing Standard Extended SOP Class uses.</para>
                    <para>Text is also added to clarify the meaning of the presence of PixelSpacing in this context.</para>
                    <para>Further, since it has proven impractical to actually retire use of the traditional single frame Secondary Capture IOD, the note deprecating it is removed.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.3 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="A.8" status="2" xml:id="sect_A.8">
            <title>Secondary Capture Image IOD</title>
            <para xml:id="para_68118ee9-6165-40d6-9a84-439cd51b353e">...</para>
            <section label="A.8.1" status="3" xml:id="sect_A.8.1">
                <title>Secondary Capture Image IOD</title>
                <section label="A.8.1.1" status="4" xml:id="sect_A.8.1.1">
                    <title>Secondary Capture Image IOD Description</title>
                    <para xml:id="para_6fe699d1-83d1-49be-b0ad-a8525c06b308">The Secondary Capture Image IOD specifies single-frame images that are converted from a non-DICOM format to a modality independent DICOM format, without any constraints on pixel data format.</para>
                    <note>
                        <para xml:id="para_696386b1-bd0c-4aa7-b8d2-1286ad70115d"><emphasis role="bold"><emphasis role="strikethrough">The use of this IOD is deprecated, and other more specific SC Image IODs should be used.</emphasis></emphasis></para>
                    </note>
                </section>
                <section label="A.8.1.3" status="4" xml:id="sect_A.8.1.3">
                    <title>Secondary Capture Image IOD Module Table</title>
                    <para xml:id="para_21d63567-d82e-46f6-8c28-cad42abb6c6c"> ...</para>
                    <table frame="box" label="A.8-1" rules="all" xml:id="table_A.8-1">
                        <caption>Secondary Capture Image IOD Modules</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_63e943e1-6db9-4448-833d-2c51d12f72b6">IE</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_df4644ac-9426-498c-bea2-0abcd54a4dc0">Module</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c0a053fa-eaae-4dc9-a74b-ccee602c4bd0">Reference</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f51956f0-5224-4b83-b064-285528936220">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_d22c10ec-08e2-444c-924b-74c119bcc99d">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_097779b7-42ea-4c65-88d0-76328abb9eef">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ff4e9be-c699-4670-a1fd-9762ed756b24">
                                        <xref linkend="sect_C.7.1.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f7705f1f-0bf9-45c7-9daf-937049e13c0b">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_882d7392-f204-4359-8f52-b1e30a49f5f7">Clinical Trial Subject</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_92acf924-f7f4-4953-b137-6b68289a49ab">
                                        <xref linkend="sect_C.7.1.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_01b069de-57c6-4867-bf59-5ddd106d1403">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="3">
                                    <para xml:id="para_38b39df6-9242-47ad-9f25-52d269fddfea">Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_438eb3b4-a5ac-4c1f-90f5-8fd8ed271dc7">General Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2b44a48a-dd8b-4b4a-ab23-8c0162c4468e">
                                        <xref linkend="sect_C.7.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_488650c6-3a6b-4697-9ed8-aec1ca514896">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d4e56f45-d8c8-4d48-be6a-bc23d8b50461">Patient Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e314b66a-ab12-4363-98c1-d0d4c6c620d1">
                                        <xref linkend="sect_C.7.2.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_adf9304f-0d11-4d6c-bbc6-17d39061f034">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cc3a40b8-ddd8-4eb3-a009-90108f68f3fe">Clinical Trial Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dd00aa11-9a8e-4576-bad1-455ffb7cd162">
                                        <xref linkend="sect_C.7.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_56f36e82-4948-429e-a2aa-6f6b37bb9521">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_073a71a6-064e-40b8-b872-7e885fcbf985">Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ed2d6d8-49f4-496e-934f-52d6e9e7253b">General Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_aa2dfec2-781a-412a-a98b-371c8cafccd9">
                                        <xref linkend="sect_C.7.3.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e47ba8fa-9925-469e-bd52-eab82b6207f8">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2a1de3b3-7369-4f0c-8d7e-cfe8b8e9fc3e">Clinical Trial Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_609995bb-3e2e-40d6-b655-9d8a35699bc8">
                                        <xref linkend="sect_C.7.3.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f1bd2599-9b9a-496d-9a66-b01d8500b110">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para><emphasis role="bold"><emphasis role="underline">Frame of Reference</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Frame of Reference</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <xref linkend="sect_C.7.4.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Synchronization</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <xref linkend="sect_C.7.4.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_ee06ccf5-efe9-45bd-8868-f1042d1c306a">Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c12d79c-326b-47bf-ada7-36ba7e91574f">General Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_107a18b1-fcc3-4c47-b7d5-cf365dcc6757">
                                        <xref linkend="sect_C.7.5.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_39ac0829-0b11-4250-8faa-0aeb0964dd15">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6b9ed7c3-6ca9-42c8-a2fb-cc2d77201f6a">SC Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5e5a9aa3-549e-453f-92bd-fc32d3327ea3">
                                        <xref linkend="sect_C.8.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6c7c9347-15b5-42a0-94d7-eb8998497864">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ed0e5cd5-5e93-4e3a-9261-1806e9c47bf5">Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9ba00ae1-4b1a-4e7d-a256-219e81dfdb71">General Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f918945d-7710-4685-902f-345138dca6c2">
                                        <xref linkend="sect_C.7.10.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64b7af2f-2529-49f2-94bd-f7001765ad23">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="13">
                                    <para xml:id="para_a90da1e5-bdc3-49db-8a3b-b7709c56492d">Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2f2fc6e0-7adb-49aa-92dd-cba38c18d502">General Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7eeaf308-16c5-45e4-a087-035cdec10b33">
                                        <xref linkend="sect_C.7.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f4689bfe-9bf8-4c62-babf-265757b6866d">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_228fd454-0ae0-4994-959c-4dc32eb266e4">General Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_79ca3745-4dc0-4a60-b344-11b6af402d2a">
                                        <xref linkend="sect_C.12.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb012cdc-237e-4233-becb-6e35c25d0eec">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">Image Plane</emphasis></emphasis></para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para>
                                        <xref linkend="sect_C.7.6.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para><emphasis role="bold"><emphasis role="underline">U</emphasis></emphasis></para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82be4f17-af80-412d-a356-45c149930886">Image Pixel</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99539d63-da6e-4f2c-8514-a0efcde4cd8b">
                                        <xref linkend="sect_C.7.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_efdf0645-b53d-43b5-8ce9-a8e7bc4b4273">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b345b2f2-6fee-4fbf-bd7c-02693e514820">Device</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_18db7738-a734-4cb6-934a-1f4ed8fe7980">
                                        <xref linkend="sect_C.7.6.12" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5db98c0c-d6e0-492a-a2e9-b9f583b04530">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_309f03aa-773f-4a59-8e4a-c5b45d61752d">Specimen</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e72e0659-25ac-451b-8095-f61ba8b591eb">
                                        <xref linkend="sect_C.7.6.22" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_40a4150a-e4fe-40ca-9960-0c8ec0876971">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_26b5d065-95c2-421a-92aa-e286af9023b9">SC Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_55a142a8-a91b-41ba-8b5a-db3d58a21748">
                                        <xref linkend="sect_C.8.6.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f3cae139-5ba0-459b-807d-c9208d8a60a1">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dd2499a8-38c4-41b7-a5e5-22d60753029b">Overlay Plane</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7c314a43-c565-4f13-8f1f-54a10962c77e">
                                        <xref linkend="sect_C.9.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_87b2707f-74f9-4ec5-bae2-0bee753be958">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71afe214-cef7-4a96-85a8-7194e8d5a459">Modality LUT</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_efb3b046-11dd-4d22-88c5-39c59804d34e">
                                        <xref linkend="sect_C.11.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_13c6e35b-f445-4252-8ab7-36f8eeb7420c">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5927cab7-f2ce-441b-b8ee-c436c4167e2f">VOI LUT</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_507bfb6e-95fe-4a96-832c-8dc2f5533682">
                                        <xref linkend="sect_C.11.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb7de1f0-d861-4054-b4c3-974d849f817f">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3a633b2e-3a56-4297-b55f-f3b4416382a7">ICC Profile</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_77940310-64d4-4115-ae60-c13947dfcf85">
                                        <xref linkend="sect_C.11.15" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_98421c02-9cd2-47c0-98c0-3ddd1e22f70c">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6be8583d-e156-49ef-96b9-e4aaf72c4f7b">SOP Common</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb78295f-2f96-4b5e-86b1-eed24d28e730">
                                        <xref linkend="sect_C.12.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1405705b-ba83-4d51-96c1-98fae005206c">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e881f951-6fff-4f9f-907a-b51ee1814430">Common Instance Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_57753d7e-5788-4808-b9e6-21e8de51e3d5">
                                        <xref linkend="sect_C.12.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e117f9f-7147-41a0-8c49-2f1615144cba">U</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <note>
                        <para><emphasis role="bold"><emphasis role="underline">If Image Position (Patient) (0020,0032) and Image Orientation (Patient) (0020,0037) (from the <xref linkend="sect_C.7.6.2" xrefstyle="select: title"/>) are present,
                            then the values of Pixel Spacing (0028,0030) (from the <xref linkend="sect_C.7.6.2" xrefstyle="select: title"/> and the <xref linkend="sect_10.7" xrefstyle="select: title"/> included from the <xref linkend="sect_C.8.6.2" xrefstyle="select: title"/>)
                            are intended to be used for 3D spatial computations, rather than any values of Nominal Scanned Pixel Spacing (0018,2010) (from the <xref linkend="sect_C.8.6.2" xrefstyle="select: title"/>), which may also be present.</emphasis></emphasis></para>
                    </note>
                </section>
            </section>
                                <section label="A.8.3" status="3" xml:id="sect_A.8.3">
                <title>Multi-frame Grayscale Byte Secondary Capture Image IOD</title>
                <section label="A.8.3.3" status="4" xml:id="sect_A.8.3.3">
                    <title>Multi-frame Grayscale Byte Secondary Capture Image IOD Module Table</title>
                    <para xml:id="para_c02c9231-8199-4678-a8f0-fdcd57e7dec1"> ...</para>
                    <table frame="box" label="A.8-3" rules="all" xml:id="table_A.8-3">
                        <caption>Multi-frame Grayscale Byte Secondary Capture Image IOD Modules</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_34b720f4-aee6-4a64-a5d6-186b61f2b2a6">IE</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b4dbaed5-bd2d-4595-986e-edc364374f9b">Module</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7c540dc6-3879-4336-82d8-5f022bbc7016">Reference</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4e52dff8-85de-4b6d-b52b-96b6b29590cd">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_1e816f1c-aa89-4335-8593-087195dc6467">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_568951d3-c52c-4b37-bf0b-06f65e0fdf11">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_485c6990-ba67-4a2c-af4e-061cf1a29f38">
                                        <xref linkend="sect_C.7.1.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4d9885f0-7a13-4501-89b1-1612d2dc91d6">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bca4cd8d-6393-4d8b-884b-88cc50083704">Clinical Trial Subject</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_22472c22-6a8f-4b72-b876-4b5fe59211fe">
                                        <xref linkend="sect_C.7.1.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7d7e5ee8-d500-4fac-9730-62a585c6e408">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="3">
                                    <para xml:id="para_66505a7f-5d76-429b-9980-1f71c0f5399f">Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_25148270-8772-4c28-80d9-14c9578130b0">General Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_66b45013-570f-4234-a22e-7dad8f89c66f">
                                        <xref linkend="sect_C.7.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c4365fc8-8737-4a3c-92ac-500d8734d03b">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_beff161a-0cdc-4531-ab55-6448760244b9">Patient Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e74d8886-2c94-447f-b7a5-7979776795f4">
                                        <xref linkend="sect_C.7.2.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9c4c9675-b73b-4bcf-b0a4-1ade4bca7085">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c7bcb4e9-2394-43e5-b110-fe3ec11e30da">Clinical Trial Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ecc50a44-fbd2-4c74-a7e5-2ece04629dbb">
                                        <xref linkend="sect_C.7.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1c75c713-fbe5-46ea-bd42-f8046db94eb9">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_44460933-e5c7-4d6e-b3de-fcf31401aaa5">Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2e9ffb87-28bf-4160-b011-553b20e66e52">General Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f6da05c0-830e-44b8-9453-efb86203edee">
                                        <xref linkend="sect_C.7.3.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6b6220e8-afb1-4a07-9627-727a22f64063">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91bc7cdb-06af-4d13-a7da-2463d15217ea">Clinical Trial Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5f204ed1-16f3-42d3-aaad-598207c3940a">
                                        <xref linkend="sect_C.7.3.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fda5caea-52dd-4a88-92ae-3582e2e27b43">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_6b78aee3-af29-4e91-bed2-f4ac70ea42ca">Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d670c764-1af9-4ee4-9893-657cc2195f7b">General Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b96ae687-8e30-4749-986e-7753d1d0fd43">
                                        <xref linkend="sect_C.7.5.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_aaa8d8b6-3744-4638-bda7-a4d8507b8cce">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b2775c22-617b-408f-997b-dc8c0a46a5d8">SC Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dab5684a-1f2e-45b5-9f16-41cf29bd1f98">
                                        <xref linkend="sect_C.8.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3dc28961-4dd5-4374-b752-92400c37301d">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_eb4873e5-a6d6-4b0a-9a0e-a10844efc2cb">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7d692ab5-1f59-41e4-8078-c64d91169eef">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_63dfbfb1-8071-4cc0-9bca-ec2a136948e2">
                                        <xref linkend="sect_C.7.4.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_78428c33-2feb-4205-aa7d-37b686cf504d">C - Required if Pixel Measures or Plane Position (Patient) or Plane Orientation (Patient) Functional Group Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_df9295d6-47a9-40dd-a778-9ecd7e8d4515">Synchronization</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4c5d09d6-9ce0-4501-b80d-9778dc911691">
                                        <xref linkend="sect_C.7.4.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e3955468-d113-4609-b385-25ad102a614c">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b85043c7-fd6a-4f7a-9fe5-b7e696168883">Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_720b1186-5815-4a85-9f52-c00d81445a82">General Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_382d4b38-a18e-465a-94f9-324e5193d685">
                                        <xref linkend="sect_C.7.10.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_900df17e-f46b-421c-8c18-ca37ecbbce58">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="17">
                                    <para xml:id="para_dba25fb2-5559-4df8-aaef-8cf04c45245b">Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_57a54214-7a64-4660-9688-a47a3e87d647">General Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b95649fd-6e6c-4d38-8e06-18a62ea22a2f">
                                        <xref linkend="sect_C.7.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_858c9600-24d6-4776-87b2-992a8e4fa559">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4846231d-440b-478e-95f8-6d8d26332c1d">General Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_05627f61-da44-4d44-b9cc-a83025ec463f">
                                        <xref linkend="sect_C.12.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2efde80c-6abd-4c8b-b855-255e864ed4a3">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0b322be6-75c5-427e-b4fe-1538f352ad36">Image Pixel</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08305692-ddde-4a10-b08d-d89abf8afb7f">
                                        <xref linkend="sect_C.7.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c40ffad3-8421-4acf-b755-e7f7728811b7">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c01aa05b-8dca-43b7-9468-d5b46afccc15">Cine</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e7426826-4506-4300-af0a-f8eb4928c69b">
                                        <xref linkend="sect_C.7.6.5" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1fed3bc2-15e3-4ed9-a4c5-616cb4ed9a56">C - Required if Frame Increment Pointer (0028,0009) is Frame Time (0018,1063) or Frame Time Vector (0018,1065)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3063815d-d717-4cdc-87ec-7309764acb75">Multi-frame</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_91ff1ef5-8820-45f3-8b1b-9b2267e03ab4">
                                        <xref linkend="sect_C.7.6.6" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_852382b6-917b-48d2-a860-6a73229da94d">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bae821a9-0358-4c41-9b07-90d4c401ae5d">Frame Pointers</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9dfdbb86-68c5-4ed1-ba48-3236ca5f0966">
                                        <xref linkend="sect_C.7.6.9" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1cd16c66-1c08-4695-8433-fdc32f71a650">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4832eb31-2f0e-441a-980e-32b981d2ebf7">Device</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_96d9a9f9-2b3c-484e-aaf0-4af05363ddec">
                                        <xref linkend="sect_C.7.6.12" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b4ebaad7-4779-45bd-8065-b45a50fc6dc1">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5a952494-16d2-40e3-b037-b95023b4ad45">Multi-frame Functional Groups</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6422929a-46e6-40f1-a305-4ecc13202da3">
                                        <xref linkend="sect_C.7.6.16" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5757936a-80e1-4a1d-8570-92b314fc8cee">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_889efbb2-7463-41e9-96db-8ee2eb4e856b">Multi-frame Dimension</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b2709260-5fe7-4c9c-8d2e-514704501e11">
                                        <xref linkend="sect_C.7.6.17" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1a70a871-ee2b-4dcd-bf58-961ab1901ed2">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dbe46608-9bcf-4714-9ff8-5d943dd73513">Specimen</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82484640-d7db-4ac6-afff-9e5d2f6aead0">
                                        <xref linkend="sect_C.7.6.22" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c557ce76-f2f1-4cf9-b22f-2a1c1e5d6773">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4d6c26ed-18d4-4ce1-8702-5ba271bc5c61">SC Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0a8dca60-f790-46b4-9f0a-5dc8b796ef9e">
                                        <xref linkend="sect_C.8.6.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7e2e98f2-bf1b-419d-a906-e77c952f7e6c">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6a621630-b30c-42e8-acb1-edc433c4b715">SC Multi-frame Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d67200a7-72fb-42fa-b2ed-a70e44be57af">
                                        <xref linkend="sect_C.8.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d573b74f-5582-48da-829b-3c23676cfc3c">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3a55b8a1-eb0d-4a13-9c45-b22f341e3d58">SC Multi-frame Vector</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d61cc62d-7401-4d7d-be2c-b81419d2ad62">
                                        <xref linkend="sect_C.8.6.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a086fcf3-5064-46d7-8500-8ac694604241">C - Required if Number of Frames is greater than 1</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_36ed7a01-9350-4a02-8295-becd6f2decfe">VOI LUT</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a56b4a11-fc49-47d9-a39b-503ec0544987">
                                        <xref linkend="sect_C.11.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f93c3d3f-8bc1-4fd6-9542-4a2d35cb04c6">C - Required if the VOI LUT stage is not an identity transformation</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb8b3e79-b4d9-4132-872b-3e2e4491a09c">SOP Common</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_27f56805-fda0-4c3e-b83b-2abcecb4dc4f">
                                        <xref linkend="sect_C.12.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b8c010f2-0b79-4432-815e-f61d8c15afd2">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4b65dc79-7a49-41f4-9654-4c55ddd21cc5">Common Instance Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1a7f9eec-8cef-46d1-8d40-ab5eab50932a">
                                        <xref linkend="sect_C.12.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_12c4b8f6-f6f5-4da0-a9fc-cb029b33d665">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8c872798-bb44-49f2-b304-4d9b80cf3dff">Frame Extraction</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_71c4b6aa-4171-4e01-9196-55ee96990869">
                                        <xref linkend="sect_C.12.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a85ef795-985e-4250-adc6-e15f48b9c5e4">C - Required if the SOP Instance was created in response to a Frame-Level retrieve request</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.8.3.5" status="4" xml:id="sect_A.8.3.5">
                    <title>Multi-frame Grayscale Byte Secondary Capture Image Functional Group Macros</title>
                    <para xml:id="para_4340da03-4b86-4525-a486-86ca96bff678"> ...</para>
                    <table frame="box" label="A.8-3b" rules="all" xml:id="table_A.8-3b">
                        <caption>Multi-frame Grayscale Byte Secondary Capture Image Functional Group Macros</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8515ad50-2711-4e03-a314-34e0c24d1101">Functional Group Macro</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d84346ca-5c13-40e6-88a0-852207c6e667">Section</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d791bc21-75e3-47bd-b52d-e190440be6e4">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_18eb17a8-f562-460d-9bca-221ed736e17d">Pixel Measures</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e4ded456-c11b-47cc-8b8a-8910570f1f3f">
                                        <xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99a1a2c8-179d-4480-81c0-006fe811c4e6">C - Required if Plane Position (Patient) or Plane Orientation (Patient) Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fc83d5e-cc3b-4b53-b20c-f4181c952d0a">Plane Position (Patient)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b41bceef-7676-4ecf-9e0f-bf6941aea783">
                                        <xref linkend="sect_C.7.6.16.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ab5338e0-530f-403c-b29d-70085512bda6">C - Required if Pixel Measures or Plane Orientation (Patient) Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e66bcb4a-3c07-43c2-a248-6b70d18c44cb">Plane Orientation (Patient)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_21347c32-e1e8-4d0d-bd00-4ecbeb75729d">
                                        <xref linkend="sect_C.7.6.16.2.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4f13f951-2745-485c-a921-45852cb7cbd6">C - Required if Pixel Measures or Plane Position (Patient) Macros Present</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <note>
                        <para><emphasis role="bold"><emphasis role="underline">If the <xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: title"/> is present, then the values of Pixel Spacing (0028,0030) therein are intended to be used for 3D spatial computations, rather than any values of Nominal Scanned Pixel Spacing (0018,2010) (from the <xref linkend="sect_C.8.6.3" xrefstyle="select: title"/>), which may also be present.</emphasis></emphasis></para>
                    </note>
                </section>
            </section>
            <section label="A.8.4" status="3" xml:id="sect_A.8.4">
                <title>Multi-frame Grayscale Word Secondary Capture Image IOD</title>
                <section label="A.8.4.3" status="4" xml:id="sect_A.8.4.3">
                    <title>Multi-frame Grayscale Word Secondary Capture Image IOD Module Table</title>
                    <para xml:id="para_1f5b06bc-9276-4d80-b30c-635e298f3f2f"> ...</para>
                    <table frame="box" label="A.8-4" rules="all" xml:id="table_A.8-4">
                        <caption>Multi-frame Grayscale Word Secondary Capture Image IOD Modules</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_07c7c2ea-e8c7-44b2-96f6-f106a6d9beb2">IE</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_721e2308-48c0-40d0-8552-046bb0e120a6">Module</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d937027d-167d-44d0-a031-6f68837b2767">Reference</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d645daf3-54d6-42e6-b114-f22b91321ede">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_37d2b670-a128-468f-b7d9-6bac80605959">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b8fa44b8-08f2-49bb-8fa7-f2930a23294a">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b7ea3cc1-6c84-4c32-8778-29e1ea2b116d">
                                        <xref linkend="sect_C.7.1.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a9dff492-4ea5-4d03-860b-8264995f5b2a">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7cced10e-6af4-439b-9169-529252b264ac">Clinical Trial Subject</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b4639060-9bb3-40bf-b51a-d665f5f00862">
                                        <xref linkend="sect_C.7.1.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bb8c8a66-f7e1-4568-982f-a43fc2baf744">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="3">
                                    <para xml:id="para_d1920b82-d0d2-469a-a4e8-20254cdac2b3">Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb875e28-2510-473f-85b4-e8b26bd44d84">General Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb9ddc5c-951d-4537-ac59-df7cd9a08cd6">
                                        <xref linkend="sect_C.7.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e70e63a5-c691-4c0a-89f3-f35c56ec2805">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9ec4c7fa-53b5-40b5-98c6-c6a05e2c05b0">Patient Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1fa5c668-1499-4e72-9531-09fa0a61078a">
                                        <xref linkend="sect_C.7.2.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_da4ee8a9-9d29-438f-ab62-4d8f837f6adf">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b4fa4486-0b51-49f1-8498-3b02cb2eff79">Clinical Trial Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_63b0b120-09fd-49d7-a250-8ea48b7ba2e8">
                                        <xref linkend="sect_C.7.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f92e2d92-c2c2-493c-98a0-e753b3377abb">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_0a0b6395-8b86-4284-b12a-4456a48a8d35">Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_10e0b4e9-384e-44ec-9b4b-f84421b6dea2">General Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c07155a8-ff9c-4559-a17b-a88e178982e9">
                                        <xref linkend="sect_C.7.3.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0e46d289-8f51-498f-acb9-f97a0e6019a4">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5c7718aa-a869-4603-8b01-770d0cd3de5f">Clinical Trial Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_32f55f29-21b5-441c-a58d-00cc83b69ab9">
                                        <xref linkend="sect_C.7.3.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d2d6429b-2962-4b82-8bfc-c261b1412f7d">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_b38304cf-06e7-4645-a6b8-259752d1e453">Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_449a084f-b309-4e65-a840-f03ebdafdc05">General Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6df74660-b615-49b9-8bdd-44f16310bea3">
                                        <xref linkend="sect_C.7.5.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e414bc75-c842-4d8a-866a-88c041ddba8e">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_836802e9-da70-4f5e-b78d-85e9ee77665c">SC Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b282148b-6874-41bf-84dc-a255ea1f4fda">
                                        <xref linkend="sect_C.8.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_215ed1ca-d7b9-4702-806d-c077341da51a">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_531912c5-a2c7-4da3-a4f7-951d5b7867c1">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_64ef2fa3-7c4b-48e0-86f5-940ca6143484">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3dd4d6a8-438d-4408-b41f-a76332a2272c">
                                        <xref linkend="sect_C.7.4.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_086a125c-e94f-4953-a671-8a8e589563f5">C - Required if Pixel Measures or Plane Position (Patient) or Plane Orientation (Patient) Functional Group Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_36831e66-e4d2-448c-beb8-612ce1486278">Synchronization</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_650617d6-07bb-4817-8b54-4933a950a5c4">
                                        <xref linkend="sect_C.7.4.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a371fb64-9d01-427e-a320-f99930dc9c0f">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c3a40345-6a3d-447a-86dc-4b3d726431ad">Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_22a0c2d1-43f3-4dda-8d6f-be1b5bc232f0">General Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_abb98408-8880-4f58-9c28-4ed23230f7d1">
                                        <xref linkend="sect_C.7.10.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7b960e8c-061c-44be-adb2-8cf674b21ab9">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="17">
                                    <para xml:id="para_2ffb1bfd-e35a-46ff-920b-2e3f66baff93">Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c9cbdb77-e56c-4b9c-9835-e05acf6bb23b">General Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d2c3ae4e-3fe2-4680-ae7c-c5a531e23dfd">
                                        <xref linkend="sect_C.7.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c441be40-ff83-415e-b6cc-8928af9d2011">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_925575c9-a48c-4959-9e58-33b7c0745aa8">General Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a72ffac8-b600-46a8-aeae-8db054f72b4f">
                                        <xref linkend="sect_C.12.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5a82cf2f-2854-480e-8815-87250eb0ae64">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_54aba25c-a703-450b-a717-c290052750b9">Image Pixel</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c4bcc094-1e2c-4521-9f0b-fca85fa406ee">
                                        <xref linkend="sect_C.7.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e8919e80-f61a-44c3-b38a-d3a6e540a02f">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_812e0264-1d25-4033-9330-b7990e471df7">Cine</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7ef86697-a5ac-44c4-864f-ac2f56c66670">
                                        <xref linkend="sect_C.7.6.5" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2495ee96-cc94-42f4-b381-4343b4d55f97">C - Required if Frame Increment Pointer (0028,0009) is Frame Time (0018,1063) or Frame Time Vector (0018,1065)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e056902c-ca76-4ef6-aa73-a6a463d36ae6">Multi-frame</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_806b745e-6d77-4092-9323-ce9e63e65b46">
                                        <xref linkend="sect_C.7.6.6" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_693575e7-7d1f-422a-ba20-a1acb2507000">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0860a537-737c-4a84-b104-e56e2c1d5b2e">Frame Pointers</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_216b7dd2-cbe8-4810-8d7f-f5fe0223beb2">
                                        <xref linkend="sect_C.7.6.9" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b85943ed-0253-48bd-8ece-067e10d6a3a7">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7a1bfffc-188d-4c42-9af1-d585f7317f00">Device</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_155af2bd-4d29-44a7-a161-ce0de3ab217f">
                                        <xref linkend="sect_C.7.6.12" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e16a0064-9672-4b3c-a509-1264de91d24e">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cec948d5-972f-4b91-97c4-afe09e4bbf85">Multi-frame Functional Groups</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2c5b83f1-23b5-4a5f-becc-9addb074f4e1">
                                        <xref linkend="sect_C.7.6.16" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_eb11832d-d9fe-43d3-8d1d-01322564f189">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d4fbd247-25d7-4a64-ba95-290629daec22">Multi-frame Dimension</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6fba45f1-a1c7-4123-a40c-fdaf87714167">
                                        <xref linkend="sect_C.7.6.17" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4fca3835-a42a-4555-8ba3-fda5876656d3">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_934690dd-e3ae-4920-a039-e6ce978da0f7">Specimen</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_352ede2f-4d01-46ad-9071-0df665613978">
                                        <xref linkend="sect_C.7.6.22" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb66fa17-8e58-4298-97c5-e0e2eba04e93">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_82efc9e5-f719-4fd7-add2-7b4828e91af3">SC Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0831bbaa-51c6-4fbd-9c85-136dbf862891">
                                        <xref linkend="sect_C.8.6.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1a848879-88eb-4ff1-ad79-04e76b2741fd">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_de083820-8934-4f30-9d5e-7829eaed877b">SC Multi-frame Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_70f08756-fc7e-4bfc-a04a-3b37bc344b92">
                                        <xref linkend="sect_C.8.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e1483736-4e7b-4b0f-becd-49b3f2581a55">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_af971269-8edf-4c2b-a862-39b01c215199">SC Multi-frame Vector</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0e99cde6-bf14-464b-b92e-fddacedd1742">
                                        <xref linkend="sect_C.8.6.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a7a8d83b-ceb8-4407-ae70-370db3714b05">C - Required if Number of Frames is greater than 1</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_89f0c840-cf9d-4e5a-b23d-a138685cdd69">VOI LUT</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e6d2f2b1-7a99-418a-a0bb-55ee58aec67f">
                                        <xref linkend="sect_C.11.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_704c398c-ddb5-4a47-ac35-41ddbf493c41">C - Required if the VOI LUT stage is not an identity transformation</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dbab4485-d546-4b7b-abc0-90c185b223a5">SOP Common</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c75712a5-8806-4e33-a817-b48528c2157e">
                                        <xref linkend="sect_C.12.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1ceba3f3-fbb6-4bc7-91bf-64f6de11ee4a">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_62535268-79c2-48bb-a855-30d8cb866ef2">Common Instance Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_99b4b259-dded-48d5-9190-4f595e3de4ba">
                                        <xref linkend="sect_C.12.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d0a20c52-f9f5-4f85-84a4-a53da6c16315">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e6feedc5-e5db-458d-a75f-14e249a936c6">Frame Extraction</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0fb96392-06ee-4945-8360-aa8d16f8d384">
                                        <xref linkend="sect_C.12.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2dab69c9-9b45-4364-9ba8-afa3649b0c8b">C - Required if the SOP Instance was created in response to a Frame-Level retrieve request</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.8.4.5" status="4" xml:id="sect_A.8.4.5">
                    <title>Multi-frame Grayscale Word Secondary Capture Image Functional Group Macros</title>
                    <para xml:id="para_95dd1f8b-ecec-4749-874b-4c02d24347c2"> ...</para>
                    <table frame="box" label="A.8-4b" rules="all" xml:id="table_A.8-4b">
                        <caption>Multi-frame Grayscale Word Secondary Capture Image Functional Group Macros</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c53a37d7-baae-4090-b29d-d406bd7595f2">Functional Group Macro</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_90bb3f8d-3972-42ae-81fc-5239dd9a87d3">Section</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c39589aa-330d-420a-af85-3e71ba0667e8">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b900ee3f-de0d-40f7-9dc0-091b5fb8d7a7">Pixel Measures</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e947cbcd-bb02-4012-baf7-fdec0a593324">
                                        <xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e7108540-dd26-487b-94ae-f6998fbddd80">C - Required if Plane Position (Patient) or Plane Orientation (Patient) Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ac76927-a31d-460f-880e-3ebb36f6c217">Plane Position (Patient)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f3cb06b6-2f50-463a-9ece-820ccc5e2039">
                                        <xref linkend="sect_C.7.6.16.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d74b5ba9-7635-469b-9278-af7d694d27ce">C - Required if Pixel Measures or Plane Orientation (Patient) Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_90f4c323-7c69-48f6-9344-e8c2da020d7f">Plane Orientation (Patient)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_fbd54f4c-937d-41ea-9610-97b59ce797ef">
                                        <xref linkend="sect_C.7.6.16.2.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4fa3b3d4-a61e-467e-a46f-07110dd14f48">C - Required if Pixel Measures or Plane Position (Patient) Macros Present</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <note>
                        <para><emphasis role="bold"><emphasis role="underline">If the <xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: title"/> is present, then the values of Pixel Spacing (0028,0030) therein are intended to be used for 3D spatial computations, rather than any values of Nominal Scanned Pixel Spacing (0018,2010) (from the <xref linkend="sect_C.8.6.3" xrefstyle="select: title"/>), which may also be present.</emphasis></emphasis></para>
                    </note>
                </section>
            </section>
            <section label="A.8.5" status="3" xml:id="sect_A.8.5">
                <title>Multi-frame True Color Secondary Capture Image IOD</title>
                <section label="A.8.5.3" status="4" xml:id="sect_A.8.5.3">
                    <title>Multi-frame True Color Secondary Capture Image IOD Module Table</title>
                    <para xml:id="para_6ba0bf15-2c26-44a0-be81-33681de7a4c7"> ...</para>
                    <table frame="box" label="A.8-5" rules="all" xml:id="table_A.8-5">
                        <caption>Multi-frame True Color Secondary Capture Image IOD Modules</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_946c76b1-bec0-4f7a-8e2a-6e43dfbaea72">IE</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_66dd14d6-a876-4e0f-9bd4-f872657632ce">Module</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1c22a498-9c5d-445c-b08b-51ec2a1316bf">Reference</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cef3158d-1f8f-407d-bedb-af4dbbc31d41">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_11e93b71-ad81-4b89-b0ba-ac0de9aedc5e">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e5d1bb3-388a-4bcd-859a-bc064608bfb3">Patient</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b52d6092-5a89-45b8-b021-295d12988456">
                                        <xref linkend="sect_C.7.1.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8ebb6c86-b212-44e9-baad-d4d059a349d0">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9075487a-dc8c-4f66-9c10-3c3497eac699">Clinical Trial Subject</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3262cf37-c933-449c-a919-4da1d1cc8217">
                                        <xref linkend="sect_C.7.1.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b9829a89-762d-4051-9080-80aa8fd94033">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="3">
                                    <para xml:id="para_b4c4e980-6e76-46a0-8c0d-87e5c40a5935">Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7b334402-2502-4ee2-8476-48cfd4d08700">General Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_094d4ede-6285-4fff-b9e5-da11553d4d22">
                                        <xref linkend="sect_C.7.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cb716a7f-a787-4671-89e4-81c2fbd31ae7">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d81c9497-96db-4bba-872f-3a9093a2bb28">Patient Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_962693e1-df65-495b-b632-487119419c1f">
                                        <xref linkend="sect_C.7.2.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c2bbd9c6-c46f-4acd-9c30-a06b8ab72ed3">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b514ec21-b6ec-4285-a32c-654003ebe388">Clinical Trial Study</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_96bd460d-179e-413b-9591-ccfca67bc8ea">
                                        <xref linkend="sect_C.7.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e53920e0-11bf-48e8-8632-c80d6e2f7b15">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_7e217602-ea01-423b-93a8-28f543874420">Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bd295ab4-63b3-499a-809a-1a77a404b4c8">General Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_25c5c263-8dbc-4a82-b6f4-ad19ce828dcc">
                                        <xref linkend="sect_C.7.3.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2c9147dc-ae6e-4bb9-b94c-ce4f9520e97a">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_74e38295-d1e7-406d-8ddf-d8183797cecd">Clinical Trial Series</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1205b21a-fcb4-4800-9b77-52b31356b54e">
                                        <xref linkend="sect_C.7.3.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d23ba4d7-1677-47c0-82ba-e6cd4f38a0ae">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_d90ff56d-8f0f-4022-9137-5d62768390eb">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_623c38e5-62ec-4601-a4d7-0e124e9c85a9">Frame of Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_af16e1d0-fc0e-45d3-9321-97b61d959fef">
                                        <xref linkend="sect_C.7.4.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0af2dfc3-7a7b-43c4-ad7c-8bf857058fab">C - Required if Pixel Measures or Plane Position (Patient) or Plane Orientation (Patient) Functional Group Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_514fd97b-d8ea-4030-8565-19ff5c73eb6d">Synchronization</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_481abf0b-044d-4af9-b7da-a6c324452db5">
                                        <xref linkend="sect_C.7.4.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3f76a072-f736-4ed7-9ac6-76ed54c9167a">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="2">
                                    <para xml:id="para_2a6319a9-c635-4075-a55c-af457cf70f17">Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2b30b1f8-7d81-4904-af1b-94761cd18606">General Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0ff62af8-c3b1-47c2-a225-85b7a8007c08">
                                        <xref linkend="sect_C.7.5.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0d00dcc9-cf6f-4b54-b072-ec63fa8191d7">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d34d27bc-65bc-43b0-9b80-455158ae2dc3">SC Equipment</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c1f3e492-f5c1-4267-893f-27e41d5ac5ea">
                                        <xref linkend="sect_C.8.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d27974c8-655a-4a75-b323-89dc0bb8912e">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e01c6322-12ae-4ca9-ac5f-decb3fe8a94f">Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_08586332-a1ed-4678-8c80-c346e587f17d">General Acquisition</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ce909af5-3cef-4ad8-9c5d-802e997aad4d">
                                        <xref linkend="sect_C.7.10.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_66dc7aa1-af6f-4984-a5eb-9520b17a6b8e">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="17">
                                    <para xml:id="para_77f2f6e6-c165-4b7c-861a-fd3e0092515e">Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0edd2604-952f-4e41-9644-5902c1a8f61a">General Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e72093e4-f250-4f20-b0d7-ec2ad1c54bb4">
                                        <xref linkend="sect_C.7.6.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a90ce00d-b5a9-47f3-946b-e33476ef496e">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_769d893f-4d18-4e23-bd4c-f9de4266c1b4">General Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5b498376-30eb-4a51-8cce-1f1193c8b5b8">
                                        <xref linkend="sect_C.12.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d287df18-768c-4324-a602-aee5f2a8c537">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_07782e98-606a-4745-b3dc-d3e20be162ed">Image Pixel</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2ec268f1-e13a-4ced-898c-2160ecc8a8e3">
                                        <xref linkend="sect_C.7.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d7c20862-0a09-4d4a-8a87-6ad19e6ac815">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_77299d69-6218-4658-a3fe-8b13d802d074">Cine</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_21b0a2a2-2606-43ba-a7de-25036cff2c82">
                                        <xref linkend="sect_C.7.6.5" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e600d1a7-d9a7-495e-96c5-29964a56394c">C - Required if Frame Increment Pointer (0028,0009) is Frame Time (0018,1063) or Frame Time Vector (0018,1065)</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a4cd8de4-429c-4ae1-90a7-44c70c494794">Multi-frame</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5d203ee1-22a8-4479-a2c5-b2492bfbf5bd">
                                        <xref linkend="sect_C.7.6.6" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_49ac8448-bb4b-4818-a614-13528febffb2">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_efa8f779-63aa-4ef0-b20a-f9af78c94e2f">Frame Pointers</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1219853f-37fc-4667-8be0-6528f62c1e66">
                                        <xref linkend="sect_C.7.6.9" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_33a2e60d-685b-48db-a303-65e002362613">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7f284558-7752-4284-8888-ad0aebe66317">Device</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d5ca6505-f08a-48c8-a560-6db8385fe869">
                                        <xref linkend="sect_C.7.6.12" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_33c0774f-1680-4d26-b28b-cbb6cf0016c2">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4c14860e-2131-4a46-96ac-1f2f0c16c702">Multi-frame Functional Groups</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2e800c4d-c218-482c-a11a-87304f3b5b9c">
                                        <xref linkend="sect_C.7.6.16" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9b4fe994-9476-41db-afcd-6e9418cb2f32">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e9d713ae-1056-4604-815a-9cd338e84ec3">Multi-frame Dimension</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9fbb380b-cbbc-485b-a67b-21c3febfcdaa">
                                        <xref linkend="sect_C.7.6.17" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c0597d9a-bf98-4d30-8ee4-c65a59a23168">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f174e779-94f1-411c-8fd5-fa53d9ddff2e">Specimen</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c9dda6c8-214f-4a8b-bc3a-63190c7fa5df">
                                        <xref linkend="sect_C.7.6.22" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6453f378-5163-43fa-87e2-c2dc40b4feeb">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_659cce6a-5993-47b6-ad12-379297813d3e">SC Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bc52a1dc-89a1-486d-a9e6-9714a891fc45">
                                        <xref linkend="sect_C.8.6.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_75091967-9572-408f-83fd-9347f106a2fc">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_30a28379-52fa-4a41-bf88-7a04c94f2a3f">SC Multi-frame Image</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bb0d98ed-db7f-4ed7-92e1-ff0423390285">
                                        <xref linkend="sect_C.8.6.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6136ac04-2908-48f3-b04e-65b3f470a33e">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1d28caaa-e465-4a0f-bc42-8758afeb276f">SC Multi-frame Vector</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b25c6c10-5f84-4dde-bdf8-6749de8eb2a0">
                                        <xref linkend="sect_C.8.6.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3ead2274-f114-46f6-a1ca-5f182c456e82">C - Required if Number of Frames is greater than 1</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4b70ff5e-1b11-4c34-a263-8532ea57bfaf">ICC Profile</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4dc6c010-30ba-4b9c-8d65-b080fa0676e4">
                                        <xref linkend="sect_C.11.15" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4ca927b2-5e71-4b3b-a6cc-2c0b4c1091a7">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e6d7a098-8a6f-4f5c-b12f-f526bd5ed2aa">SOP Common</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_53779fbb-bb3d-4792-b41b-714ec6c3856b">
                                        <xref linkend="sect_C.12.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ad67227d-8dbd-46f9-b783-6e0849ed12f2">M</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b6b38660-64df-4204-a36d-fd75c2047ccb">Common Instance Reference</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_51e36dd1-4aa8-4cde-acb4-dda225856632">
                                        <xref linkend="sect_C.12.2" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7280ae46-64e2-4a39-afe5-45a388db2432">U</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_09819abf-f1e6-43fb-86b4-29777541d220">Frame Extraction</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e7c21138-51c2-44e2-951d-015089a61c58">
                                        <xref linkend="sect_C.12.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b60ae1fb-0887-46d9-a47e-3eb489db42ac">C - Required if the SOP Instance was created in response to a Frame-Level retrieve request</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
                <section label="A.8.5.5" status="4" xml:id="sect_A.8.5.5">
                    <title>Multi-frame True Color Secondary Capture Image Functional Group Macros</title>
                    <para xml:id="para_55f78ee3-fd05-43d8-a395-0bb378933e3a"> ...</para>
                    <table frame="box" label="A.8-5b" rules="all" xml:id="table_A.8-5b">
                        <caption>Multi-frame True Color Secondary Capture Image Functional Group Macros</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_16b1c4e0-1da7-4755-b389-6f7570428d43">Functional Group Macro</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_6351f86a-2bc6-4e55-a669-c1881997bf3c">Section</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f00c210b-ce72-4ee7-bb10-68175e9e0128">Usage</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f12e56d2-c416-4639-9177-e89d35f40696">Pixel Measures</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7569c633-de9f-4ecb-b0f1-85d5316fba5a">
                                        <xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bc30b048-f98f-459f-975c-d1ec888ea9a6">C - Required if Plane Position (Patient) or Plane Orientation (Patient) Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_058b767d-c32c-4a5d-8b0d-d11c8ada9b57">Plane Position (Patient)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_bf2aeb75-4356-4304-ab0c-17fe1e1c5c3e">
                                        <xref linkend="sect_C.7.6.16.2.3" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1cee7c42-f07d-4366-9950-4b270afc729f">C - Required if Pixel Measures or Plane Orientation (Patient) Macros Present</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a520824a-196c-4fbf-9126-2882835431ef">Plane Orientation (Patient)</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6f10166a-a22f-435e-b953-e5612d62bc6a">
                                        <xref linkend="sect_C.7.6.16.2.4" xrefstyle="select: labelnumber"/>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9bc5f29c-60b4-4982-842c-e3a5722d1c4e">C - Required if Pixel Measures or Plane Position (Patient) Macros Present</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <note>
                        <para><emphasis role="bold"><emphasis role="underline">If the <xref linkend="sect_C.7.6.16.2.1" xrefstyle="select: title"/> is present, then the values of Pixel Spacing (0028,0030) therein are intended to be used for 3D spatial computations, rather than any values of Nominal Scanned Pixel Spacing (0018,2010) (from the <xref linkend="sect_C.8.6.3" xrefstyle="select: title"/>), which may also be present.</emphasis></emphasis></para>
                    </note>
                </section>
            </section>

            
        </section>
        
        
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        
        <section label="A.3" status="2" xml:id="sect_A.3">
            <title>CT Image IOD</title>
            <section label="A.3.1" status="3" xml:id="sect_A.3.1">
                <title>CT Image IOD Description</title>
                <para xml:id="para_fb8dd083-1414-48b7-9d01-e763e2dc8732">The Computed Tomography (CT) Image IOD specifies an image that has been created by a computed tomography imaging device.</para>
            </section>
            <section label="A.3.2" status="3" xml:id="sect_A.3.2">
                <title>CT Image IOD Entity-Relationship Model</title>
                <para xml:id="para_5cf5ac0f-5a99-4cde-989c-34ceb4d0e1cd">This IOD uses the E-R Model in <xref linkend="sect_A.1.2" xrefstyle="select: label"/>, with only the Image IE below the Series IE.</para>
            </section>
            <section label="A.3.3" status="3" xml:id="sect_A.3.3">
                <title>CT Image IOD Module Table</title>
                <para xml:id="para_bfb13ffd-c2b4-4b65-b05d-f4414ce61692">
                    <xref linkend="table_A.3-1" xrefstyle="select: label"/> specifies the Modules of the CT Image IOD.</para>
                <table frame="box" label="A.3-1" rules="all" xml:id="table_A.3-1">
                    <caption>CT Image IOD Modules</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_214112ac-721f-486a-be6a-2597dcbc70bb">IE</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_302cd7d8-c30c-46a1-ad12-c3954af8ee6c">Module</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_85431da6-d428-407e-9c17-d6bb0572ed80">Reference</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_de9a329d-4d96-49ef-813b-f7ed74c4baa4">Usage</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="2">
                                <para xml:id="para_50c79060-20ed-490d-b7b8-4c0594062d1d">Patient</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_99f6501a-80db-47ee-a9c8-1fb2d7b48bec">Patient</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4e3e8104-1463-4f8f-822c-d57964e4e66d">
                                    <xref linkend="sect_C.7.1.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_86814e25-0623-44ad-8d14-cdafdcc05046">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ed3ff446-ba8c-44dc-8041-c71ef807f7bd">Clinical Trial Subject</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_68418705-1164-48e5-8c6b-aed378c06ffe">
                                    <xref linkend="sect_C.7.1.3" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1462a110-e9e7-4a25-aadb-de407d6827cf">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="3">
                                <para xml:id="para_825a7a77-fa62-4efb-afb8-40162024b7e2">Study</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e063ec3d-4f38-4c23-a1f0-636801bae138">General Study</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_73545da7-01f8-47f1-a7d8-24affa04babe">
                                    <xref linkend="sect_C.7.2.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7210f0b3-bd88-45bd-882a-d76f39d0ea0c">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d1f4c2e8-bbf6-46a3-8e2c-db24c714531f">Patient Study</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32e8ba19-4de6-4b05-93d0-afca9881a5d1">
                                    <xref linkend="sect_C.7.2.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8662a642-12f6-4bd4-845b-167f09bdbb3c">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a063f2fd-eab6-4a0e-936a-59926aee13fc">Clinical Trial Study</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3193153c-49b1-414e-9f78-69a39b4a50b6">
                                    <xref linkend="sect_C.7.2.3" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14d45998-6249-470f-ad16-cfd134ec3aed">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="2">
                                <para xml:id="para_60662264-a701-448a-b7b0-9565ac0b622d">Series</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_56324560-266b-4003-9fdd-85ce0f7953f5">General Series</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6dec30cc-0815-41a9-882d-f834f60afd14">
                                    <xref linkend="sect_C.7.3.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_718d551d-dbdb-446c-9814-4da69c7bdf05">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_792ef5c1-4160-442a-a7a2-8259e501770b">Clinical Trial Series</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5db8931-c335-4e52-9d07-f78016d24af3">
                                    <xref linkend="sect_C.7.3.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_51c26a00-6e8a-414a-8716-04b966786498">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="2">
                                <para xml:id="para_6e98e6c1-c0b0-4630-9b3e-1e959eacc74c">Frame of Reference</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b6d4bf8d-7eff-4396-9b9f-9280cfde32c8">Frame of Reference</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_32fe977e-5784-45cb-8b7f-1d1700f9cac4">
                                    <xref linkend="sect_C.7.4.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2ff96759-f17b-4f9c-9c1c-561ecccf0be4">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3691e808-449e-42d0-8329-7407034f53c4">Synchronization</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ad666280-1021-4114-b7c8-6d47c591f7a4">
                                    <xref linkend="sect_C.7.4.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e902b967-619b-4699-8a3d-ecbed6a4dff6">C - Required if time synchronization was applied.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0f272f8c-a60e-4842-877a-9f782ef822dc">Equipment</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_29a34bb3-39c4-4615-b629-5ddbdb7dc283">General Equipment</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0048dbdc-9532-4c37-a11e-283860c0f5dd">
                                    <xref linkend="sect_C.7.5.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0ca94efe-6b6a-4886-90a2-ba057dc52f8c">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_55eeccc3-6d91-4523-8262-7215ab15d62e">Acquisition</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_87d3dc60-fdde-477b-9572-6fe7a22e02fa">General Acquisition</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c83f2470-719a-438a-874f-9297fa7ef4cc">
                                    <xref linkend="sect_C.7.10.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_0523fded-a446-45b3-bf10-7d4f82f94338">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="13">
                                <para xml:id="para_19840044-9026-4bd4-bae3-5e9cfc2378ea">Image</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_2af04aba-b192-4c48-9cbc-d5f45bf86e69">General Image</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_6bf06600-6b3e-4651-8258-4c6bab4b29c8">
                                    <xref linkend="sect_C.7.6.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_21954fa8-2b32-46c6-8392-0696583b727b">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_42ce2097-71b5-4ffc-beb8-ec3fc9a1e082">General Reference</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ba04cbd7-b5c2-4115-ae0c-d53a31d5a152">
                                    <xref linkend="sect_C.12.4" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ccb5097f-5914-4926-80f9-5af8e64aa7ee">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_70203331-0955-4339-86f4-1961b8c904c7">Image Plane</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_faea233a-c49f-4da5-9d76-395ecfb4ae49">
                                    <xref linkend="sect_C.7.6.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bfb708a8-26f6-47ed-a8e5-06caa9227f89">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_9d166336-efbd-49c0-9a50-63fb55265f6e">Image Pixel</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a3b9e1bb-5113-4f5c-9c16-803d7ef5ff83">
                                    <xref linkend="sect_C.7.6.3" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_1dc4fcd7-998b-4ede-847f-a97dfa28af99">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_c53881c0-e79a-4372-9fa6-bb7a0fb0e871">Contrast/Bolus</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_50cd3187-d824-4fac-9850-c70175713bec">
                                    <xref linkend="sect_C.7.6.4" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_44130fcc-e2ac-401d-9f68-983b0927106e">C - Required if contrast media was used in this image</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_867f95b1-2af6-49cd-b418-1bca609c0c48">Device</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_dd11122a-5277-41ca-9444-a659bc9fb096">
                                    <xref linkend="sect_C.7.6.12" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f5c7c6a5-f6c4-47e4-80b5-15a44b9de3be">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_63d0232d-5539-4a2e-95a5-4f0f8ea77ade">Specimen</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ebbaec3d-585a-4427-94e5-491a9cb95d53">
                                    <xref linkend="sect_C.7.6.22" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_bb46f595-cc12-4e42-bf74-c3c62b2d0711">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_7d01cbae-952b-4e88-a7ca-bfacc748d0a9">CT Image</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_48209c8e-2c56-4fbc-b5d6-6514e0a75e51">
                                    <xref linkend="sect_C.8.2.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4cef1937-ff1d-4087-9463-726db621778e">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8f14d58d-169c-4f00-b1ea-c1de18cc8632">Multi-energy CT Image</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_4a01f8a4-6d56-4141-83a2-ebb17d1abc13">
                                    <xref linkend="sect_C.8.2.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_e86b95fc-aa8c-4d9a-9d4a-8ab664a926ca">C - Required if Multi-energy CT Acquisition (0018,9361) is YES.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_129565b4-ecb8-4200-b76f-0439966f1bc9">Overlay Plane</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_775dbb1b-6b98-4f0b-a1e4-75224c86ea3f">
                                    <xref linkend="sect_C.9.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_f0377ccf-ca2c-48b6-b420-bfa60bbb8b85">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d54bb6d8-45a7-4c04-be37-e632f8a6bbcb">VOI LUT</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ea6f98b7-d652-47d4-a2ba-931e9e43ecb5">
                                    <xref linkend="sect_C.11.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d3c5bbe5-0006-4f23-a377-0b588faad6cf">U</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_311090ff-6c4d-4991-95b3-d324a173d258">SOP Common</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b7ac48a7-a585-4d9f-ad0a-20f1cf4fe565">
                                    <xref linkend="sect_C.12.1" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_8594150f-10ae-4da9-a0dd-1a6b451dc3c8">M</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_a95858cc-fd4c-4a6e-b5bf-998bb1eac2e4">Common Instance Reference</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_14d33e15-c432-4b1b-803b-cd97f2661b7e">
                                    <xref linkend="sect_C.12.2" xrefstyle="select: labelnumber"/>
                                </para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_3f229691-06dd-41c2-91a4-f8ed641e3f49">U</para>
                            </td>
                        </tr>
                    </tbody>
                </table>
            </section>
        </section>
        
        
        <section label="C.7.4" status="3" xml:id="sect_C.7.4">
                <title>Common Frame of Reference Information Entity Modules</title>
                <section label="C.7.4.1" status="4" xml:id="sect_C.7.4.1">
                    <title>Frame of Reference Module</title>
                    <para xml:id="para_8a06ca3d-dda2-4533-a66b-1f44293d2bcd"> ...</para>
                    <table frame="box" label="C.7-6" rules="all" xml:id="table_C.7-6">
                        <caption>Frame of Reference Module Attributes</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a23693d7-c7db-427d-a00b-800e33aa106a">Attribute Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_79f12b22-3cad-4e6a-a0fc-542fa964c01e">Tag</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_55652984-ada1-4891-9478-f2203b5dca6e">Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e5d51f58-5797-4eea-b9ab-f2e8e987819b">Attribute Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ae575a68-dd44-49fa-bcd3-41bede551c1e">Frame of Reference UID</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9b1908ae-6320-4499-a848-ada8df0ae656">(0020,0052)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b2811b3a-45ed-442a-84b0-7fd450a8a7d8">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ef4ebef0-bffa-4538-9315-483200f4df4d">Uniquely identifies the Frame of Reference for a Series. See <xref linkend="sect_C.7.4.1.1.1" xrefstyle="select: label"/> for further explanation.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6d4e3fcc-1f0e-43cc-8287-963a4813bca5">Position Reference Indicator</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8510f98d-1aa3-4fe3-b732-fee3b6c67749">(0020,1040)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1a14e28e-ad3b-48d4-8c95-e4a31bae2e8f">2</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cd0f70e1-e94c-457d-a514-b9797a338a06">Part of the imaging target used as a reference. See <xref linkend="sect_C.7.4.1.1.2" xrefstyle="select: label"/> for further explanation.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <section label="C.7.4.1.1" status="5" xml:id="sect_C.7.4.1.1">
                        <title>Frame of Reference Module Attribute Descriptions</title>
                        <section label="C.7.4.1.1.1" status="6" xml:id="sect_C.7.4.1.1.1">
                            <title>Frame of Reference UID</title>
                            <para xml:id="para_7f7bf0cf-a7ac-413a-b95c-e2e2b4072504">...</para>
                        </section>
                        <section label="C.7.4.1.1.2" status="6" xml:id="sect_C.7.4.1.1.2">
                            <title>Position Reference Indicator</title>
                            <para xml:id="para_2a14c7a0-39b8-492f-976f-66526365329a">...</para>
                        </section>
                    </section>
                </section>
                <section label="C.7.4.2" status="4" xml:id="sect_C.7.4.2">
                    <title>Synchronization Module</title>
                    <para xml:id="para_fbb8e2fb-e2cb-4d36-b573-4be924a8a97c"> ...</para>
                </section>
            </section>
        
        <section label="C.7.6.2" status="4" xml:id="sect_C.7.6.2">
                    <title>Image Plane Module</title>
                    <para xml:id="para_81876b9d-5726-4ab4-8b99-5c66f4d63024"> ...</para>
                    <table frame="box" label="C.7-10" rules="all" xml:id="table_C.7-10">
                        <caption>Image Plane Module Attributes</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4cb4e252-7aae-402b-9ce5-4b48608aa146">Attribute Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ef5a5a9a-c545-44ea-95c5-85d0959fcf6b">Tag</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_baf8cfc4-de88-4f88-9243-d560be4bba91">Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a62c9195-44e6-45a8-9e82-7679caf887f8">Attribute Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_09be5138-c425-4b3a-b186-4deffbb7cb52">Pixel Spacing</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5a4b15f5-db2c-47f7-8bf5-4dfeee0ac322">(0028,0030)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_dd12f3eb-e241-4f80-a323-4048687813c0">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0990d168-0f15-4a44-8425-628117447661">Physical distance in the patient between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_5c1047cf-bfee-45ae-ac55-25d4fda02a33">Image Orientation (Patient)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a4038941-73c1-48fe-bdce-a76546089564">(0020,0037)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_c0116d7d-f83a-4d4c-bb80-72a009b45edb">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c3827cd7-5ffc-4532-a3fd-ded943f68397">The direction cosines of the first row and the first column with respect to the patient. See <xref linkend="sect_C.7.6.2.1.1" xrefstyle="select: label"/> for further explanation.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4527eedd-9f70-4d9e-8b6d-1ca90e539ed3">Image Position (Patient)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7e757b55-0b83-4181-91fb-7d93c6656593">(0020,0032)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_851d362b-8df2-4bc7-bf8f-3c897b58b945">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ad2a2a3f-9c63-4aa4-aaee-4baa70930da4">The x, y, and z coordinates of the upper left hand corner (center of the first voxel transmitted) of the image, in mm. See <xref linkend="sect_C.7.6.2.1.1" xrefstyle="select: label"/> for further explanation.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7f9e1890-b7bc-4f86-bf7d-e77beea6cbfe">Slice Thickness</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aa42af64-f519-4f41-adbf-8b8dc1916b60">(0018,0050)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_11424cc2-4040-4fc8-8574-d7eba09bc376">2</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_03dd7545-36c3-4140-aef3-09a375164753">Nominal slice thickness, in mm.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_b463d699-93b3-4bd3-b362-2d109f1e5d3a">Spacing Between Slices</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4f2fbb33-e8b7-4f07-97ed-5a5a27857959">(0018,0088)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_32b3afa9-4fa1-45d4-81cc-3df730c48485">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_9f54fd0a-bef3-48a9-97f8-8bdc2a43cb56">Spacing between adjacent slices, in mm. The spacing is measured from the center-to-center of each slice.</para>
                                    <para xml:id="para_808f7f36-7db8-48d2-b9c7-a703307eadb4">If present, shall not be negative, unless specialized to define the meaning of the sign in a specialized IOD, e.g., as in the <xref linkend="sect_C.8.4.15" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2b9e9c7e-1951-4216-8da5-170999d00061">Slice Location</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a8e14a02-4112-497e-a374-0121e5f52556">(0020,1041)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d3d4848f-4063-4e8a-9d55-4715be682ffb">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f4902707-5a4a-43a9-a7de-3e43c7852e51">Relative position of the image plane expressed in mm. See <xref linkend="sect_C.7.6.2.1.2" xrefstyle="select: label"/> for further explanation.</para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <section label="C.7.6.2.1" status="5" xml:id="sect_C.7.6.2.1">
                        <title>Image Plane Module Attribute Descriptions</title>
                        <section label="C.7.6.2.1.1" status="6" xml:id="sect_C.7.6.2.1.1">
                            <title>Image Position and Image Orientation</title>
                            <para xml:id="para_98a38bd3-9b8a-40ea-9146-391989cddce0">...</para>
                        </section>
                        <section label="C.7.6.2.1.2" status="6" xml:id="sect_C.7.6.2.1.2">
                            <title>Slice Location</title>
                            <para xml:id="para_b94f410c-b405-4db9-9208-ab69ab3aeacb">...</para>
                        </section>
                    </section>
                </section>
        
        <section label="C.7.6.16.2.1" status="6" xml:id="sect_C.7.6.16.2.1">
            <title>Pixel Measures Macro</title>
            <para xml:id="para_283bbab1-a2bf-4a16-84e6-d42695ad61f6"> ...</para>
            <table frame="box" label="C.7.6.16-2" rules="all" xml:id="table_C.7.6.16-2">
                <caption>Pixel Measures Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3992f536-4458-4e2d-94b4-57afc8a475db">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_337b926f-fc29-4567-9e61-3a8b0f52be53">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0611a4b5-9e2d-45ca-97ea-4d03d4d6094f">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08b7c6a8-f3e7-4fab-bce7-cdcc7d937f78">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_56ecd3d0-ba02-47a5-8912-b235590de93b">Pixel Measures Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_051d3a9f-2d16-4272-b227-00b9cd425a74">(0028,9110)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_29b518c6-c069-4886-a7e2-1166aa6a9a27">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_d90b1b3b-3f9e-4c9f-8dae-7a0f7094df35">Identifies the physical characteristics of the pixels of this frame.</para>
                            <para xml:id="para_bf5e449f-5ea0-4966-af25-0fe69fddc0c4">Only a single Item shall be included in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2e05f4d3-26bd-47fa-9afb-a5b4fbae7212">&gt;Pixel Spacing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ce11d30-84bf-4c14-8ba3-97aa67e90836">(0028,0030)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_502fe013-a4a0-40cd-94e8-27da2139be84">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_7da3ffd0-d044-4f67-8d46-b89fa2480435">Physical distance in the imaging target (patient, specimen, or phantom) between the centers of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation of the value order.</para>
                            <note>
                                <orderedlist>
                                    <listitem>
                                        <para xml:id="para_455e363a-b31f-40c6-8e35-a278cff5c446">In the case of CT images with an Acquisition Type (0018,9302) of CONSTANT_ANGLE, the pixel spacing is that in a plane normal to the central ray of the diverging X-Ray beam as it passes through the data collection center.</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_c5f80af7-9c07-4f30-868f-3f21193de688">In the case of Enhanced RT Image ("1.2.840.10008.5.1.4.1.1.481.23") or Enhanced Continuous RT Image ("1.2.840.10008.5.1.4.1.1.481.24") the pixel spacing is defined on the x/y plane at z = 0 of the Image Receptor Coordinate System.</para>
                                    </listitem>
                                </orderedlist>
                            </note>
                            <para xml:id="para_91b814f3-4fb9-4854-b861-eae3971d5485">Required if:</para>
                            <itemizedlist>
                                <listitem>
                                    <para xml:id="para_46ca9662-60b2-4003-96a2-6ee71bd6919f">Volumetric Properties (0008,9206) is other than DISTORTED or SAMPLED, and Image Type (0008,0008) Value 3 is not LABEL or OVERVIEW, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_4f60e859-7de7-490f-9539-9699548d655e">SOP Class UID is Segmentation Storage ("1.2.840.10008.5.1.4.1.1.66.4") and Frame of Reference UID (0020,0052) is present, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_9e39180f-3d47-41ab-98fd-2cce0ccedac6">SOP Class UID is Ophthalmic Tomography Image Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.4") and Ophthalmic Volumetric Properties Flag (0022,1622) is YES, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_5e272059-3f28-466d-8527-0cb3aeff5413">SOP Class UID is Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.8"), or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_7e21bb43-146e-4c12-a1d7-69f38f9d2d23">SOP Class UID is Enhanced RT Image ("1.2.840.10008.5.1.4.1.1.481.23"), or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_eee447ae-0fbf-48f1-8a15-6efdb947c539">SOP Class UID is Enhanced Continuous RT Image ("1.2.840.10008.5.1.4.1.1.481.24").</para>
                                </listitem>
                            </itemizedlist>
                            <para xml:id="para_f6668dcf-e253-4dec-a832-9204bfb4f8b8">May be present otherwise.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_e5827725-4fab-480a-9f50-85d2c7004b41">&gt;Slice Thickness</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_955c0dba-b1d5-4d61-9373-6253d97e345b">(0018,0050)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_93a4f798-6c58-4a3d-89a1-701e16cb9330">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_39b10803-3e0d-47b9-8bcc-980653f14b8d">Nominal reconstructed slice thickness (for tomographic imaging) or depth of field (for optical non-tomographic imaging), in mm.</para>
                            <para xml:id="para_3e015ab0-05b9-4a55-ad40-f08477bd4ad7">See <xref linkend="sect_C.7.6.16.2.3.1" xrefstyle="select: label"/> for further explanation.</para>
                            <note>
                                <para xml:id="para_ed492080-b894-4488-aaa2-9b2554cdcb1b">Depth of field may be an extended depth of field created by focus stacking (see <xref linkend="sect_C.8.12.4" xrefstyle="select: label"/>).</para>
                            </note>
                            <para xml:id="para_5a4e9680-d607-458f-b068-b0a1b4aa003c">Required if:</para>
                            <itemizedlist>
                                <listitem>
                                    <para xml:id="para_8e861a56-8d1d-489e-9ffb-91486caca8e3">Volumetric Properties (0008,9206) is VOLUME or SAMPLED, and Image Type (0008,0008) Value 3 is not LABEL or OVERVIEW, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_2d062c45-e834-47e3-aec8-eff93e80fbb0">SOP Class UID is Segmentation Storage ("1.2.840.10008.5.1.4.1.1.66.4") and Frame of Reference UID (0020,0052) is present, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_06408d93-de2d-4cce-b3ba-1033777db305">SOP Class UID is Ophthalmic Tomography Image Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.4") and Ophthalmic Volumetric Properties Flag (0022,1622) is YES, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_5265c600-6690-45c1-91b4-75e87c0db4f5">SOP Class UID is Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.8").</para>
                                </listitem>
                            </itemizedlist>
                            <para xml:id="para_6555345a-53b7-4e7f-8b1f-3370a2d19e61">May be present otherwise, if</para>
                            <itemizedlist>
                                <listitem>
                                    <para xml:id="para_5a5ef21e-5459-408f-a17c-05763c8be789">SOP Class UID is not Enhanced RT Image ("1.2.840.10008.5.1.4.1.1.481.23"), and</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_b07dcf46-2ebd-4929-9c9d-96535398844f">SOP Class UID is not Enhanced Continuous RT Image ("1.2.840.10008.5.1.4.1.1.481.24").</para>
                                </listitem>
                            </itemizedlist>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_6d5eed76-9ae2-4505-b13d-b4bd93b2080b">&gt;Spacing Between Slices</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0891b7bd-67fa-4963-ac40-5fea88778ee4">(0018,0088)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_65e86e48-bb45-4fdd-8624-0d7e1912ac27">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3874a405-c3b1-4f6b-a78c-8dbcbbacb876">Spacing between adjacent slices, in mm. The spacing is measured from the center-to-center of each slice, and if present shall not be negative.</para>
                            <para xml:id="para_2a27a0ca-e588-4dd3-8eec-5a225b88a3ab">Required if Dimension Organization Type (0020,9311) is TILED_FULL and Total Pixel Matrix Focal Planes (0048,0303) is greater than 1. May be present otherwise.</para>
                            <note>
                                <para xml:id="para_46d23721-f2aa-485f-a5a5-817268ce8789">In the case of Whole Slide Images, Spacing Between Slices (0018,0088) describes the spacing of focal planes separately encoded, and is distinct from Distance Between Focal Planes (0048,0014), which describes in what manner different focal planes were combined into a single encoded plane (focus stacking).</para>
                            </note>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        <section label="C.7.6.16.2.3" status="6" xml:id="sect_C.7.6.16.2.3">
            <title>Plane Position (Patient) Macro</title>
            <para xml:id="para_b82179ac-da77-42a0-8cb6-eadec5e45360"> ...</para>
            <table frame="box" label="C.7.6.16-4" rules="all" xml:id="table_C.7.6.16-4">
                <caption>Plane Position (Patient) Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_637cf64e-0b8a-47ef-bcd4-ca7e42634c91">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5dfd7dbc-fa9e-44b7-90b0-1d92649efbf8">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8c1a4ee9-e5df-49f6-bf6b-e3162d8b9cd1">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a742c75-9728-4561-a94c-e156416ea0c1">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2c06b2ff-6ef9-44df-8ccc-8e608e93fde2">Plane Position Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1471ba7c-6d18-422e-9a33-cb86b21a1be4">(0020,9113)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6b6f4e0-76a9-4db5-a659-284c99a7d7f0">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_56fc9f22-e504-4af2-bdf0-7328e12b6f61">Identifies the position of the plane of this frame.</para>
                            <para xml:id="para_5b5fae81-13fe-4b0c-b951-307365d0c16d">Only a single Item shall be included in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b0388894-c20a-488a-9971-75668bcd53a6">&gt;Image Position (Patient)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_04801b64-7750-41ae-baf3-97bd0b50ca29">(0020,0032)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0697a067-69f5-4550-9e46-5e8120ca49fe">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_aed7e3f5-bf0e-45d2-8cd9-7a4b0f30cc5d">The x, y, and z coordinates of the upper left hand corner (center of the first voxel transmitted) of the frame, in mm. See <xref linkend="sect_C.7.6.2.1.1" xrefstyle="select: label"/> and <xref linkend="sect_C.7.6.16.2.3.1" xrefstyle="select: label"/> for further explanation.</para>
                            <note>
                                <para xml:id="para_ba69d0b7-048d-4de7-bfde-b1b4100d17c8">In the case of CT images with an Acquisition Type (0018,9302) of CONSTANT_ANGLE the image plane is defined to pass through the data collection center and be normal to the central ray of the diverging X-Ray beam.</para>
                            </note>
                            <para xml:id="para_78ce9d13-b459-4402-b1fa-c36ab053ee4f">Required if:</para>
                            <itemizedlist>
                                <listitem>
                                    <para xml:id="para_d99dc091-ccbd-47f1-a3d9-0c722f1cd249">Frame Type (0008,9007) Value 1 of this frame is ORIGINAL and Volumetric Properties (0008,9206) of this frame is other than DISTORTED, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_f02e21ce-756d-407e-8825-9b4e3e9a458b">SOP Class UID is Segmentation Storage ("1.2.840.10008.5.1.4.1.1.66.4") and Frame of Reference UID (0020,0052) is present, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_c277e7b4-392d-4787-82eb-b985e627ef13">SOP Class UID is Ophthalmic Tomography Image Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.4") and Ophthalmic Volumetric Properties Flag (0022,1622) is YES, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_b116f203-fd97-459f-b53d-3199c19d449a">SOP Class UID is Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.8").</para>
                                </listitem>
                            </itemizedlist>
                            <para xml:id="para_03f651cf-c561-49ed-9703-f4589f54f7d9">May be present otherwise.</para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="C.7.6.16.2.3.1" status="7" xml:id="sect_C.7.6.16.2.3.1">
                <title>Position and Orientation for SAMPLED Frames</title>
                <para xml:id="para_01fe18a6-e095-45df-a0dd-bb0088d1a860">In the case of Volumetric Properties (0008,9206) having a value of SAMPLED, Image Position (0020,0032), Image Orientation (0020,0037) and Slice Thickness (0018,0050) shall represent the volume from which the frame was derived based on the orientation of the sampling performed.</para>
                <note>
                    <para xml:id="para_8c181c84-5184-4e34-99b2-16e8155c21f0">For example in the case of MAX_IP:</para>
                </note>
                <para xml:id="para_d4d69e19-d4c9-4906-9799-8d34eadcb1fe">The Image Orientation shall be the direction of the ray used for projection of the center of the plane.</para>
                <para xml:id="para_617e95af-623a-4e7a-b8b1-b51dea2ede94">The image position shall contain the x, y, and z coordinates of the intersection of the mid-plane of the sampled volume with the ray used to project the upper left hand corner of the frame.</para>
                <para xml:id="para_3085e963-5259-4adb-a68e-91089c143f48">The Slice Thickness shall contain the distance that the ray used for projection of the center of the plane traveled through the volume.</para>
            </section>
        </section>
        <section label="C.7.6.16.2.4" status="6" xml:id="sect_C.7.6.16.2.4">
            <title>Plane Orientation (Patient) Macro</title>
            <para xml:id="para_9c4311b2-510c-4b84-b847-76cb59380479"> ...</para>
            <table frame="box" label="C.7.6.16-5" rules="all" xml:id="table_C.7.6.16-5">
                <caption>Plane Orientation (Patient) Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a3ca5dee-ffe4-4e04-8f21-9b5517b2aa03">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_237796ac-bd86-4e10-b3a2-88145e5cbf09">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_23d4eb95-3b6b-47c2-b5b5-847391bca75f">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_18c51aed-bf5b-4ffb-93d4-c89d83e4a30c">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3033e5c2-a163-4cc0-af88-2078a74d50e8">Plane Orientation Sequence</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ba5c0d92-9ec3-4655-8d77-9502eb4de1e7">(0020,9116)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f698b59a-df11-45d4-90d3-87d158549aca">1</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_f549dfb8-5444-4505-9f0d-d32ef0edf061">Identifies orientation of the plane of this frame.</para>
                            <para xml:id="para_930cf617-7dbf-4a27-ae1b-3b59f7bf2ae2">Only a single Item shall be included in this Sequence.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3e872fe2-fa3f-47f8-9a47-ac3278d4168d">&gt;Image Orientation (Patient)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d3c33485-64af-43bc-be44-cb382e4925a3">(0020,0037)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_130f7df4-bc28-4907-b3cb-131af952b528">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_872e4c29-5e52-4cab-b59c-2cdc29aa9421">The direction cosines of the first row and the first column with respect to the patient. See <xref linkend="sect_C.7.6.2.1.1" xrefstyle="select: label"/> and <xref linkend="sect_C.7.6.16.2.3.1" xrefstyle="select: label"/> for further explanation.</para>
                            <para xml:id="para_a74162da-8b5a-4b57-8112-38a998daf489">Required if:</para>
                            <itemizedlist>
                                <listitem>
                                    <para xml:id="para_29a0ca1f-1c99-4a1e-af3e-429d63aeb43b">Frame Type (0008,9007) Value 1 of this frame is ORIGINAL and Volumetric Properties (0008,9206) of this frame is other than DISTORTED, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_bdb0a5ba-960c-48ff-9287-42036df4a13b">SOP Class UID is Segmentation Storage ("1.2.840.10008.5.1.4.1.1.66.4") and Frame of Reference UID (0020,0052) is present, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_dfc60e8b-494a-406a-9c81-e880f9745df5">SOP Class UID is Ophthalmic Tomography Image Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.4") and Ophthalmic Volumetric Properties Flag (0022,1622) is YES, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_3315744c-05ad-4e03-9e95-92d0f697f1d9">SOP Class UID is Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage ("1.2.840.10008.5.1.4.1.1.77.1.5.8"), or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_c6594e10-a639-4e2e-8c5d-8f4f128a6d17">SOP Class UID is Enhanced RT Image ("1.2.840.10008.5.1.4.1.1.481.23"), or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_4f2f42cb-6e35-4503-b715-217e7cde4ae4">SOP Class UID is Enhanced Continuous RT Image ("1.2.840.10008.5.1.4.1.1.481.24").</para>
                                </listitem>
                            </itemizedlist>
                            <para xml:id="para_3acb06e0-ff92-4477-a8fc-2f29959efa02">May be present otherwise.</para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>

        <section label="C.8.6" status="3" xml:id="sect_C.8.6">
                <title>Secondary Capture Modules</title>
                <section label="C.8.6.1" status="4" xml:id="sect_C.8.6.1">
                    <title>SC Equipment Module</title>
                    <para xml:id="para_e2441472-d19c-4521-8042-624946b7cc6e">...</para>
                </section>
                <section label="C.8.6.2" status="4" xml:id="sect_C.8.6.2">
                    <title>SC Image Module</title>
                    <para xml:id="para_b454e8cc-eef6-4647-b839-dda8a9de2cd6">...</para>
                    <table frame="box" label="C.8-25" rules="all" xml:id="table_C.8-25">
                        <caption>SC Image Module Attributes</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_cc5b46f7-3bed-44bb-b108-f3bd22d78f81">Attribute Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9d6d5c65-9e7a-49b1-8f41-19b059ab5daf">Tag</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_02155462-cba2-49f6-8f01-b7547f050614">Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e2a78ef8-3a3d-4116-a71b-6e01c7026b98">Attribute Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">...</td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b8f55d10-f94f-44a6-8636-9233ed160f55"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a1cb9c75-bde8-46c2-895a-9b66b533f5c8"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_17a99082-56ee-4253-9a03-b90f48abf3c5"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e40b8360-07f4-4081-a6a8-697f81fbbc13">Nominal Scanned Pixel Spacing</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aa7a6726-9831-461e-af0a-061c1151d887">(0018,2010)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a7a53edf-32ad-4804-8af1-7efb7e2eefc9">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_25bfa6aa-ae21-46a2-9c87-42d58964623f">Physical distance on the media being digitized or scanned between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation of the value order.</para>
                                    <para xml:id="para_60ca8ac4-43bd-48b5-82fc-efa9c69e17bd">Shall be consistent with Pixel Aspect Ratio (0028,0034), if present.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2c1aed90-a049-408d-bbce-a05b0e5c4c82">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ace39895-1811-42a1-8403-09de2289d237"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8252fcc4-68c6-47b7-89df-3d2fa59c22e9"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_73669241-08da-4f7e-96cf-65a5d4b91ffb">...</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="4" rowspan="1">
                                    <para xml:id="para_75e2c46a-d03a-42a6-b68b-76ce2ae094a1">
                                        <emphasis role="italic">Include <xref linkend="table_10-10" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="4" rowspan="1">
                                    <para xml:id="para_e52f1bc6-a5f7-4539-a0aa-f4ed4879954a"> ... </para>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                </section>
            <section label="C.8.6.3" status="4" xml:id="sect_C.8.6.3">
                <title>SC Multi-frame Image Module</title>
                <para xml:id="para_af011e55-8e34-44ba-85fb-cf0633bebbca"> ...</para>
                <table frame="box" label="C.8-25b" rules="all" xml:id="table_C.8-25b">
                    <caption>SC Multi-frame Image Module Attributes</caption>
                    <thead>
                        <tr valign="top">
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_b49ba8d1-dd6a-43ee-b8e0-e5aeb900c512">Attribute Name</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e9803b2c-57f8-4603-a4b2-b1affba161da">Tag</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_f956a979-451f-4ac0-957a-a5bc3f24b0af">Type</para>
                            </th>
                            <th align="center" colspan="1" rowspan="1">
                                <para xml:id="para_15a85e20-2cfd-4f86-aa96-25e3922a437b">Attribute Description</para>
                            </th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_d6a71f8a-be3d-4de7-bc18-60b835f5ac77">...</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_378e23a2-0e98-4416-aa8e-36923094a011"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_0a241dff-cb87-4f32-999d-247329ba367c"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_ef1b97a0-8cc1-4658-bd5a-c0873048d3b9"/>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_b5737180-237c-4b81-9bea-2f293aa55bb5">Nominal Scanned Pixel Spacing</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_c0ac136f-0c21-4089-b20e-28500cf5b0ee">(0018,2010)</para>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_289099bf-7913-4b56-98fc-fc0154657e4c">1C</para>
                            </td>
                            <td align="left" colspan="1" rowspan="1">
                                <para xml:id="para_69dcc9cf-1f1d-4a17-a307-56ed8ca2c7d3">Physical distance on the media being digitized or scanned between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/> for further explanation of the value order.</para>
                                <para xml:id="para_a68a10db-d47a-449d-a4c3-0f274b365d3b">Required if Conversion Type (0008,0064) is DF (Digitized Film). May also be present if Conversion Type (0008,0064) is SD (Scanned Document) or SI (Scanned Image).</para>
                                <para xml:id="para_53840d9f-5ed9-479c-a8b6-914cd0d9c8ef">Shall be consistent with Pixel Aspect Ratio (0028,0034), if present.</para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="4" rowspan="1">
                                <para xml:id="para_5c2d55a9-5a48-4c81-b634-fd5bcc91eb38">
                                    <emphasis role="italic">Include <xref linkend="table_10-10" xrefstyle="select: label quotedtitle"/>
                                    </emphasis>
                                </para>
                            </td>
                        </tr>
                        <tr valign="top">
                            <td align="left" colspan="1" rowspan="1">...</td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_68d81bcd-e77c-4b11-9248-f6472c6b9be4"/>
                            </td>
                            <td align="center" colspan="1" rowspan="1">
                                <para xml:id="para_e1fee26e-e488-4935-9484-9fbbc8b0b23f"/>
                            </td>
                            <td align="left" colspan="1" rowspan="1"/>
                        </tr>
                    </tbody>
                </table>
            </section>
            </section>
        
        <section label="10.7" status="2" xml:id="sect_10.7">
            <title>Basic Pixel Spacing Calibration Macro</title>
            <para xml:id="para_df145af5-fe8b-4896-9b9c-04d3770b6cda"> ...</para>
            <table frame="box" label="10-10" rules="all" xml:id="table_10-10">
                <caption>Basic Pixel Spacing Calibration Macro Attributes</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d4d43cd-3a3d-4413-be30-8057451b2b22">Attribute Name</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5da1cce5-5412-441b-b20e-81f18165b8f7">Tag</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_aa8c1498-eecd-4bb7-9a51-e482306eab39">Type</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_01a7f228-fb28-46f1-a4ce-68a504e96c59">Attribute Description</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b947024a-7536-4a84-b6aa-38964dba6fc6">Pixel Spacing</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_814ece40-af51-4c27-9bc5-6f1e880f3fc5">(0028,0030)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_eaf107b1-1133-4720-9fd2-46c25e4eec91">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_11e7b6a7-a59c-4d71-a077-6f17a73f5e0c">Physical distance in the Patient between the center of each pixel, specified by a numeric pair - adjacent row spacing (delimiter) adjacent column spacing in mm. See <xref linkend="sect_10.7.1.1" xrefstyle="select: label"/> and <xref linkend="sect_10.7.1.3" xrefstyle="select: label"/>. Required if the image has been calibrated. May be present otherwise.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_56ddef83-22f5-48c2-8959-c71b2938f0a0">Pixel Spacing Calibration Type</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_90257137-cbba-4c07-b3a8-62079f9c58fc">(0028,0A02)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f839c4fb-0401-4bb7-a5e0-c006236bc389">3</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_c5cba6e3-2362-45f1-8004-a3abc577de36">The type of correction for the effect of geometric magnification or calibration against an object of known size, if any. See <xref linkend="sect_10.7.1.2" xrefstyle="select: label"/>.</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_b00e5fef-67e2-415e-940f-31046ee3c4fb">Pixel Spacing Calibration Description</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7111dee1-a320-4273-ac66-89c51d48ba73">(0028,0A04)</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d7ed8375-754d-40eb-b26f-c59aac2d3b44">1C</para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_3b6c9b32-173e-4b58-9c40-f56d07e51a1f">A free text description of the type of correction or calibration performed.</para>
                            <note>
                                <orderedlist numeration="arabic">
                                    <listitem>
                                        <para xml:id="para_cb0a4553-0609-49d4-aa1d-d7729e6e761b">In the case of correction, the text might include description of the assumptions made about the body part and geometry and depth within the Patient.</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_3e55ce77-b039-4a90-a885-81bf899e5d08">in the case of calibration, the text might include a description of the fiducial and where it is located (e.g., "XYZ device applied to the skin over the greater trochanter").</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_7b55048d-2d71-4d58-9f30-fe8339442849">Though it is not required, the <xref linkend="sect_C.7.6.12" xrefstyle="select: title"/> may be used to describe the specific characteristics and size of the calibration device.</para>
                                    </listitem>
                                </orderedlist>
                            </note>
                            <para xml:id="para_6464e3cc-7ba0-44b0-8e2b-b656c8a9181e">Required if Pixel Spacing Calibration Type (0028,0A02) is present.</para>
                        </td>
                    </tr>
                </tbody>
            </table>
            <section label="10.7.1" status="3" xml:id="sect_10.7.1">
                <title>Basic Pixel Spacing Calibration Macro Attribute Descriptions</title>
                <section label="10.7.1.1" status="4" xml:id="sect_10.7.1.1">
                    <title>Pixel Spacing</title>
                    <para xml:id="para_c7ccd9b5-3017-4e02-b37d-c9fe231a750b">Pixel Spacing (0028,0030) specifies the physical distance in the Patient between the center of each pixel.</para>
                    <para xml:id="para_05d5f299-b8a9-4a96-a772-8c575bcd5fb3">If Pixel Spacing (0028,0030) is present and the image has not been calibrated to correct for the effect of geometric magnification, the values of this Attribute shall be the same as in Imager Pixel Spacing (0018,1164) or Nominal Scanned Pixel Spacing (0018,2010), if either of those Attributes are present.</para>
                    <para xml:id="para_e71c265e-0949-4e5d-91ad-3127b2ad1175">If Pixel Spacing (0028,0030) is present and the values are different from those in Imager Pixel Spacing (0018,1164) or Nominal Scanned Pixel Spacing (0018,2010), then the image has been corrected for known or assumed geometric magnification or calibrated with respect to some object of known size at known depth within the Patient.</para>
                    <para xml:id="para_568172eb-40ff-43a5-8efc-3da5ca02fa38">If Pixel Spacing Calibration Type (0028,0A02) and Imager Pixel Spacing (0018,1164) and Nominal Scanned Pixel Spacing (0018,2010) are absent, then it cannot be determined whether or not correction or calibration have been performed.</para>
                    <note>
                        <orderedlist numeration="arabic">
                            <listitem>
                                <para xml:id="para_eec7fb84-b402-4e14-8ce9-8a9890642422">Imager Pixel Spacing (0018,1164) is a required Attribute in DX family IODs.</para>
                            </listitem>
                            <listitem>
                                <para xml:id="para_7deb76c4-5b2a-453c-8bdb-9d3682689d9a">Nominal Scanned Pixel Spacing (0018,2010) is a required Attribute in Multi-frame SC family IODs</para>
                            </listitem>
                        </orderedlist>
                    </note>
                </section>
                <section label="10.7.1.2" status="4" xml:id="sect_10.7.1.2">
                    <title>Pixel Spacing Calibration Type</title>
                    <para xml:id="para_f24c19e9-1cb2-45d2-bb06-cc96db32cd54">The Pixel Spacing Calibration Type (0028,0A02) Attribute specifies the type of correction for the effect of geometric magnification or calibration against an object of known size, if any.</para>
                    <variablelist spacing="compact">
                        <title>Enumerated Values:</title>
                        <varlistentry>
                            <term>GEOMETRY</term>
                            <listitem>
                                <para xml:id="para_a79e2faf-217a-4675-b16f-d5244fc6c592">The Pixel Spacing (0028,0030) values account for assumed or known geometric magnification effects and correspond to some unspecified depth within the Patient; the Pixel Spacing (0028,0030) values may thus be used for measurements of objects located close to the central ray and at the same depth.</para>
                            </listitem>
                        </varlistentry>
                        <varlistentry>
                            <term>FIDUCIAL</term>
                            <listitem>
                                <para xml:id="para_10de0799-83f5-4e03-b94e-008e14a1e670">The Pixel Spacing (0028,0030) values have been calibrated by the operator or image processing software by measurement of an object (fiducial) that is visible in the pixel data and is of known size and is located close to the central ray; the Pixel Spacing (0028,0030) values may thus be used for measurements of objects located close to the central ray and located at the same depth within the Patient as the fiducial.</para>
                            </listitem>
                        </varlistentry>
                    </variablelist>
                </section>
                <section label="10.7.1.3" status="4" xml:id="sect_10.7.1.3">
                    <title>Pixel Spacing Value Order and Valid Values</title>
                    <para xml:id="para_c345f55d-bd7f-416f-8516-e8a0573401c6">...</para>
                </section>
            </section>
        </section>
    </chapter>