<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2329</title>
    <subtitle>Extend histology and microscopy imaging procedure protocol codes</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Assigned</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/09/18</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2023/07/18</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2329</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Extend histology and microscopy imaging procedure protocol codes</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.16</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>There is a need for more generic procedure protocols, and to leverage existing SNOMED CT concepts.</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>

      <informaltable rules="all" frame="box">
        <tr>
          <td>
            <para><emphasis role="italic">Amend DICOM PS3.16 as follows (changes to existing text
              are bold and <emphasis role="bold"><emphasis role="underline"
                  >underlined</emphasis></emphasis> for additions and <emphasis role="bold"
                  ><emphasis role="strikethrough">struckthrough</emphasis></emphasis> for
              removals):</emphasis></para>
          </td>
        </tr>
      </informaltable>
        
        <section label="CID 8131" status="3" xml:id="sect_CID_8131">
            <title>Pathology Imaging Protocol</title>
            <para xml:id="para_4e126767-505a-4ef5-a8e3-af666ac28775">This Context Group is intended for use in the Scheduled Protocol Code Sequence (0040,0008) and the Performed Protocol Code Sequence (0040,0260).When so used, an Item with value <link linkend="DCM_112703" xrefstyle="select: nopage">(112703, DCM, "Whole Slide Imaging")</link> may also include a Protocol Context Sequence (0040,0440) using <xref linkend="table_TID_8010" xrefstyle="select: labelnumber quotedtitle"/>.</para>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_8753e71f-36d3-4342-b016-9eda5136e784">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_8131.html" xl:show="new">HTML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-8131-PathologyImagingProtocol.json" xl:show="new">FHIR JSON</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-8131-PathologyImagingProtocol.xml" xl:show="new">FHIR XML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.948.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_6e82e0f2-af50-46fb-8628-ba628750f24d">
                            <emphasis role="bold">PathologyImagingProtocol</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">FHIR Keyword:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_380d88c3-bf6d-48c4-9afd-3697ad2fdcf6">
                            <emphasis role="bold">dicom-cid-8131-PathologyImagingProtocol</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_711c0216-a5ab-4a8a-92a1-c9bde9f8e915">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_e6342ac6-0fac-486c-badb-806067fb2ef5">
                            <emphasis role="bold"><emphasis role="strikethrough">20120605</emphasis><emphasis role="underline">yyyymmdd</emphasis></emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_21f32e88-64c4-4969-901e-39e8179e8a7d">
                            <emphasis role="bold">1.2.840.10008.6.1.948</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 8131" rules="all" xml:id="table_CID_8131">
                <caption>Pathology Imaging Protocol</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5f40d0a1-fe10-4c09-9766-54722e9a5b31">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7e0527fd-be58-4662-9e85-ca1e2a005eaa">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4d633f02-2cc4-4e40-97bf-fd9390c7b293">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para>UMLS Concept Unique ID</para>
                        </th>
                        
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_774f34b6-f475-492f-b1e0-03746b561f27">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7f2eaf87-b8e7-49a3-8df9-7eec04f70d85">
                                <link linkend="DCM_112700" xrefstyle="select: nopage">112700</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_74edbd4c-84e1-4085-96c0-4871cacaa419">Peri-operative Photographic Imaging</para>
                        </td>
                        <td/>
                        <td/>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1ec56a8e-83b0-480e-b9b6-c7ff8dd6f5bb">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fb7b1d5e-5f58-412b-ac8d-348676b1709e">
                                <link linkend="DCM_112701" xrefstyle="select: nopage">112701</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2546ad25-c9d3-4d02-b78b-d4ef6d7322cf">Gross Specimen Imaging</para>
                        </td>
                        <td/>
                        <td/>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5bcdef4a-0db9-4ea7-b49d-120826457dc9">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb26d42b-4de4-4cf1-ac89-d5495074549c">
                                <link linkend="DCM_112702" xrefstyle="select: nopage">112702</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_621b64ca-2eee-4993-b723-4aed0f4af178">Slide Microscopy</para>
                        </td>
                        <td/>
                        <td/>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_abaacce2-c7fc-44aa-9a02-ef7bf3e620cd">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e7a88e7f-ae21-41ff-b58b-c98af5281528">
                                <link linkend="DCM_112703" xrefstyle="select: nopage">112703</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_bec1a06a-c971-45bd-bc46-aecc9aa9d514">Whole Slide Imaging</para>
                        </td>
                        <td/>
                        <td/>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_331b7754-9f70-4ce9-8a56-97efbbd48525">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d8321c02-34b0-4295-8f82-46ac86561bbd">
                                <link linkend="DCM_112704" xrefstyle="select: nopage">112704</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_338260b5-3ea6-4ab7-9dce-73c3fe6ce57b">WSI 20X RGB</para>
                        </td>
                        <td/>
                        <td/>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08b0649a-4a2d-43fd-a0d1-d21faa71b238">DCM</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_650fa272-ac17-4cda-8539-8cb71e2cee6f">
                                <link linkend="DCM_112705" xrefstyle="select: nopage">112705</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_2960738a-0254-4499-8357-8e42a7561ca7">WSI 40X RGB</para>
                        </td>
                        <td/>
                        <td/>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/714797009" xl:show="new"><emphasis role="bold"><emphasis role="underline">714797009</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Histology</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/714797009" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-78326</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0344441" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0344441</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/252416005" xl:show="new"><emphasis role="bold"><emphasis role="underline">252416005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Histopathology</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/252416005" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-00045</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0430445" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0430445</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/117259009" xl:show="new"><emphasis role="bold"><emphasis role="underline">117259009</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Microscopy</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/117259009" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-40155</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0026018" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0026018</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/104157003" xl:show="new"><emphasis role="bold"><emphasis role="underline">104157003</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Light microscopy</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/104157003" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-40160</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0430389" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0430389</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/60287000" xl:show="new"><emphasis role="bold"><emphasis role="underline">60287000</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Photomicrography</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/60287000" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-40150</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0031753" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0031753</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/197157006" xl:show="new"><emphasis role="bold"><emphasis role="underline">197157006</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Photography of patient</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/197157006" xl:show="new"><emphasis role="bold"><emphasis role="underline">P0-0099D</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0431056" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0431056</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/52432005" xl:show="new"><emphasis role="bold"><emphasis role="underline">52432005</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Photography of gross organ</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/52432005" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-40140</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0200720" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0200720</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/168456004" xl:show="new"><emphasis role="bold"><emphasis role="underline">168456004</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Gross pathology request</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/168456004" xl:show="new"><emphasis role="bold"><emphasis role="underline">P0-003EB</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0438646" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0438646</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/117617002" xl:show="new"><emphasis role="bold"><emphasis role="underline">117617002</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Immunohistochemistry</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/117617002" xl:show="new"><emphasis role="bold"><emphasis role="underline">P3-44150</emphasis></emphasis></link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0021044" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0021044</emphasis></emphasis></link>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">For reference unchanged:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="D" status="1" xml:id="chapter_D">
            <title>DICOM Controlled Terminology Definitions (Normative)</title>
            <table frame="box" label="D-1" rules="all" xml:id="table_D-1">
            <caption>DICOM Controlled Terminology Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01")</caption>
            <thead>
                <tr valign="top">
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_f05607a1-90fe-4408-ad56-d194c3203ae5">Code Value</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_022556ee-7c69-4138-a152-b3fa16bb86b2">Code Meaning</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_e0270183-1962-48d5-877f-b63624671b37">Definition</para>
                    </th>
                    <th align="center" colspan="1" rowspan="1">
                        <para xml:id="para_5aa10e80-ebb2-45b9-a2a9-fe4b3eb4497c">Notes</para>
                    </th>
                </tr>
            </thead>
            <tbody>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_112700">112700</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_edeae640-98fc-435f-9549-93e60513bc1f">Peri-operative Photographic Imaging</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_8f9ab758-a40e-4bb6-bde4-fc2b9e7b642c">Procedure step protocol for photographic imaging of surgical procedures, including photography of specimens collected.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_df826225-379b-4347-bc7e-b29475712d54"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_112701">112701</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ba7a5c70-4754-400d-92c7-7fa680b47e23">Gross Specimen Imaging</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_ffb93dad-0759-4fd2-bed5-839dc2afd843">Procedure step protocol for imaging gross specimens, typically with a photographic camera (modality XC), and planning further dissection.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_c76638e0-75f2-44cc-bd4b-bb0b9bb66750"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_112702">112702</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_102379c7-e9b9-4280-be5d-346baccd6498">Slide Microscopy</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_b3e7fac5-5737-4983-834c-77a0444e4e69">Procedure step protocol for imaging slide specimens.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_9f6ebc5e-9c9d-404b-8c5c-86808cee992c"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_112703">112703</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_4f2d95d2-0882-43c2-8579-521d6151e2d9">Whole Slide Imaging</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_3773b6bb-f618-41f7-896b-7fa38cc15c9d">Procedure step protocol for imaging slide specimens using a whole slide scanner.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_826d25bc-00ea-49c1-8d11-c9151b71cad0"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_112704">112704</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_90687e91-c073-444d-b23f-738ac8ecbbe3">WSI 20X RGB</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_11877dd4-d3b6-4dbb-8ae0-c21d0392a74f">Procedure step protocol for imaging slide specimens using a whole slide scanner with a 20X nominal objective lens, in full color, with a single imaging focal plane across the image.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_263cd7b9-0ce0-4a2c-b59c-16fb66d36d47"/>
            </td>
        </tr>
        <tr valign="top">
            <td align="center" colspan="1" rowspan="1">
                <para xml:id="DCM_112705">112705</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_9faf74c3-2c22-4f7d-85cc-2ee4a9cba465">WSI 40X RGB</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_e8987e5d-a977-4594-bda2-2b38a91e05b9">Procedure step protocol for imaging slide specimens using a whole slide scanner with a 40X nominal objective lens, in full color, with a single imaging focal plane across the image.</para>
            </td>
            <td align="left" colspan="1" rowspan="1">
                <para xml:id="para_12319a0e-bc60-4221-90e4-cca469854ed2"/>
            </td>
        </tr>
            </tbody>
        </table>
        </section>
        
    </chapter>
</book>
