    <title>CP-2226</title>
    <subtitle>Add Breast Segmentation Types Context Group</subtitle>
  <chapter>
    <title></title>
    <informaltable rules="all" frame="box">
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>May 2024 Voting Packet</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>2024/03/21</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
      <td rowspan="1" colspan="1" valign="top"><para>David Clunie</para><para><link
        xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:dclunie@dclunie.com"/></para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>Christopher Lew <link
            xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="mailto:christopher.lew@duke.edu"/></para>
        </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
        <td rowspan="1" colspan="1" valign="top"><para>2022/02/19</para></td>
    </tr>
  </informaltable>
    <informaltable rules="all" frame="box">
    <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2226</para></td>
    </tr>
    <tr>
        <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Add Breast Segmentation Types Context Group</para></td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Name of Standard</para>
          <para>PS3.16</para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">
        <para>Rationale for Correction:</para>
          <para>When segmenting breast tissue on MR, it was realized that there is no concept in DICOM for breast fibroglandular tissue, nor a Context Group specific to breast segmentation. Add these.</para>
          <para>Note that these concepts represent what the tissue is, not how much of the breast is composed of such tissue (such as might be used in mammography reports and CAD, where there is a concern about how much tissue is present and breast density).</para>
                    <para>Also, they are added as Anatomic Structure category (7192), not Tissue category (7191), since they are intended for use for macroscopic images, though they could probably be used for microscopic images as well; the name of the Context Group is intentionally non-specific in this respect.</para>
                    <para>Since we are adding the concept for "skin of breast", add it to the context group for Dermatology Anatomic Sites as well.</para>
                    <para><emphasis role="italic">[Ed.Note: The definition of the NCIt:C114467 is "Breast tissue that contains glandular epithelial and fibrous tissue".]</emphasis></para>
          <para><emphasis role="italic">[Ed.Note: SNOMED CRS RequestID NN1 to add existing concepts used 68192009, 314375000, 58549005, 89749009, 279009002, 82038008, and RequestID NN2 to add new concept for breast fibroglandular tissue]</emphasis></para>
      </td>
    </tr>
    <tr>
      <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
    </tr>
  </informaltable>
  </chapter>
  <chapter>
    <title></title>
    <section>
      <title></title>
        
        <informaltable rules="all" frame="box">
            <tr><td><para><emphasis role="italic">Add new Context Group to DICOM PS3.16 as follows:</emphasis></para></td></tr>
        </informaltable>
        
        
        <section label="CID ccc1" status="3" xml:id="sect_CID_ccc1">
            <title>Breast Segmentation Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_ccc1.html" xl:show="new">HTML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-ccc1-BreastTissueSegmentationTypes.json" xl:show="new">FHIR JSON</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-ccc1-BreastTissueSegmentationTypes.xml" xl:show="new">FHIR XML</link> |
                                <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.uuu1.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para>
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para>
                                <emphasis role="bold">yyyymmdd</emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para>
                                <emphasis role="bold">1.2.840.10008.6.1.uuu1</emphasis>
                            </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID ccc1" rules="all" xml:id="table_CID_ccc1">
                <caption>Breast Segmentation Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b69c4a4d-ddde-4ff8-bd48-33675677e557">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f323bf65-695a-4fdd-990e-b4402d19d7f9">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_87266596-33ab-4e1c-9ae7-855413c0017f">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6182f0a0-10ec-4c46-929e-dbfb93f09267">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e6bbf8a0-5ffa-4950-8e37-ccb4a4549765">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>NCIt</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/ConceptReport.jsp?dictionary=NCI_Thesaurus&amp;code=C114467" xl:show="new">C114467</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Breast fibroglandular tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C3831270" xl:show="new">C3831270</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/279009002" xl:show="new">279009002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Glandular structure of breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/279009002" xl:show="new">T-D05A1</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0929301" xl:show="new">C0929301</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/89749009" xl:show="new">89749009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Fatty tissue of breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/89749009" xl:show="new">T-04430</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222621" xl:show="new">C0222621</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/58549005" xl:show="new">58549005</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Interlobular mammary connective tissue</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/58549005" xl:show="new">T-04500</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222623" xl:show="new">C0222623</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/314375000" xl:show="new">314375000</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Connective tissue of breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/314375000" xl:show="new">T-D0601</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222623" xl:show="new">C0222623</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/68192009" xl:show="new">68192009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Areolar tissue of breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/68192009" xl:show="new">T-04211</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222610" xl:show="new">C0222610</link>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/82038008" xl:show="new">82038008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para>Skin of breast</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://snomed.info/id/82038008" xl:show="new">T-02430</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0149538" xl:show="new">C0149538</link>
                            </para>
                        </td>
                    </tr>
                    
                </tbody>
            </table>
        </section>
        
      <informaltable rules="all" frame="box">
        <tr><td><para><emphasis role="italic">Amend DICOM PS3.16 as follows:</emphasis></para></td></tr>
      </informaltable>
        
        <section label="CID 7192" status="3" xml:id="sect_CID_7192">
            <title>Anatomical Structure Segmentation Property Types</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_dbf185e1-8810-4bd1-854b-09f43f3346a5">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_7192.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-7192-AnatomicalStructureSegmentationPropertyTypes.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-7192-AnatomicalStructureSegmentationPropertyTypes.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1191.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_d098bbb3-5a91-4176-80b3-a1e2d03f6d8b">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_34b12ae7-7a8e-40c9-adfb-131d77e341ed">
                            <emphasis role="bold">20170914</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ab4be288-98c0-41b5-ab3d-95bd8c63217d">
                            <emphasis role="bold">1.2.840.10008.6.1.1191</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 7192" rules="all" xml:id="table_CID_7192">
                <caption>Anatomical Structure Segmentation Property Types</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_21a96aa5-0e2f-4df9-8759-28980473fae5">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a27ffb2c-bdc9-42fa-96a6-a93567b19872">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_e2c01df9-4aed-4dc6-b3f4-12786d6a1288">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_425c8ed7-ee63-4fde-a631-01e81c13b2a0">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2efbded0-c32f-458f-b901-a24673b224d3">UMLS Concept Unique ID</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para xml:id="para_14ef616a-94da-4569-88b5-d0ac1c8634d9">
                                <emphasis role="italic">...</emphasis>
                            </para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="left" colspan="5" rowspan="1">
                            <para>
                                <emphasis role="italic"><emphasis role="bold"><emphasis role="underline">Include <xref linkend="sect_CID_ccc1" xrefstyle="select: labelnumber quotedtitle nopage"/>
                                </emphasis></emphasis></emphasis>
                            </para>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
        
        <section label="CID 4029" status="3" xml:id="sect_CID_4029">
            <title>Dermatology Anatomic Sites</title>
            <variablelist spacing="compact">
                <varlistentry>
                    <term>
                        <emphasis role="bold">Resources:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_c9123ff1-9a94-4ac3-aed5-90ec49925db9">
                            <emphasis role="bold">
                                <link xl:href="http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_4029.html" xl:show="new">HTML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/json/ValueSet-dicom-cid-4029-DermatologyAnatomicSites.json" xl:show="new">FHIR JSON</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/fhir/xml/ValueSet-dicom-cid-4029-DermatologyAnatomicSites.xml" xl:show="new">FHIR XML</link> | <link xl:href="ftp://medical.nema.org/medical/dicom/resources/valuesets/ihe/svs/1.2.840.10008.6.1.1268.xml" xl:show="new">IHE SVS XML</link>
                            </emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Type:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_4305c919-79f7-4d12-b117-74cf7a509d0c">
                            <emphasis role="bold">Extensible</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">Version:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_aec1d11e-8375-4290-aed1-8d5951e19ba3">
                                <emphasis role="bold"><emphasis role="strikethrough">20200310</emphasis>yyyymmdd</emphasis>
                            </para>
                    </listitem>
                </varlistentry>
                <varlistentry>
                    <term>
                        <emphasis role="bold">UID:</emphasis>
                    </term>
                    <listitem>
                        <para xml:id="para_ee591f34-ea81-48dd-a8d4-e678c44b0107">
                            <emphasis role="bold">1.2.840.10008.6.1.1268</emphasis>
                        </para>
                    </listitem>
                </varlistentry>
            </variablelist>
            <table frame="box" label="CID 4029" rules="all" xml:id="table_4029">
                <caption>Dermatology Anatomic Sites</caption>
                <thead>
                    <tr valign="top">
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2ecd9918-d93d-4941-a3e7-3cd7e0d9996e">Coding Scheme Designator</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a97be458-e428-490c-a703-d45fb694f0a4">Code Value</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b47d1f00-85df-4387-b6ce-0368f7f6029a">Code Meaning</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_33cd4506-2452-4b11-954a-d84e88ca5ff8">SNOMED-RT ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cb036a8f-03e5-426e-a630-9bea797e4e88">UMLS Concept Unique ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1108663a-738a-4335-a936-e8c2a3be83e1">FMA ID</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9cdda3e8-b2e3-4636-8441-289881c96aaa">ICD-11</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a7b92a9e-6f68-43cb-bd21-2a32921c3a62">NYU Code L</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_c2524719-b6a6-4d31-bc21-83318d1d8fca">NYU Code M</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ec075349-ea23-4669-90ed-2545aaa5193a">NYU Code R</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66f333ee-fa8e-41a0-844e-4404e7744f7d">Mayo Code L</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8ff64252-f888-423d-96cc-6e4c40087f0c">Mayo Code M</para>
                        </th>
                        <th align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82f19fd3-004e-4ece-a283-6ccd314c3a37">Mayo Code R</para>
                        </th>
                    </tr>
                </thead>
                <tbody>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_96992115-a6d2-46f4-a8ce-88f2f0736514">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6171173c-b074-4573-8a8d-a49746e6971d">
                                <link xl:href="http://snomed.info/id/244106003" xl:show="new">244106003</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_206ee088-5067-4e93-a145-7e8a71e260de">Skin of anterior surface of thorax</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_2f40f29d-f40a-4633-a330-baf4b563629b">
                                <link xl:href="http://snomed.info/id/244106003" xl:show="new">T-02425</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_08d9c698-231d-4696-8384-8bebfbf926b8">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0448821" xl:show="new">C0448821</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_fa40bafb-3939-43bc-bf52-33cccd88457e"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_df9d1fe0-d12d-44bb-865b-de338898b69d"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_719ca4c0-8072-496e-b17b-2b37b1a1b22c"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_16fc84d3-753e-411a-9519-21785f4c7759"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7eadbe52-2cec-43f9-b3f4-3537ecdbb0f4"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8cc9bd10-2bde-45d5-a419-7bd9d60dca95"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ce33f25e-1352-437d-9bba-081811b09f73">521</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_451641c3-ff25-4c4a-97df-c85c1bf799bd"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_85e90390-c53a-4576-b33e-238e1a636b03">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b94e5de0-0e87-492b-8b4d-b64987b1525e">
                                <link xl:href="http://snomed.info/id/181491009" xl:show="new">181491009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_37fe5db0-1580-4050-ae6f-2442d4a34d3b">Skin of anterior trunk</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_22e22acc-8b44-41bb-b0d1-5b8bc35afa8b">
                                <link xl:href="http://snomed.info/id/181491009" xl:show="new">T-02408</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6fbcabb-ee21-4f1a-ab13-830737420d72">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C3698018" xl:show="new">C3698018</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_44518bf5-6bdc-4042-86ad-8d98077c2355"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cd519956-c627-43fc-80a9-e8ca18877eda"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_1fcb7a43-9949-4160-91de-f7fc15fc0d1b"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_70b3c6bc-3395-4f49-a554-9764f6fe31e7"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9e2fc121-f93d-475c-ad2b-25b5c86f4063"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fca0989-dcd4-4bc3-a6b7-9dd2d4ef1951"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad2ae9ad-cd4a-40b9-b595-8c60c08ccfbe">521a</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7256fbb7-1c7f-40d0-a809-6bceb5440b0c"/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b6713902-ed7f-449e-a728-f83b8ecf7fe6">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f2b63fda-07aa-4d5f-9631-db34c9e6624e">
                                <link xl:href="http://snomed.info/id/72005009" xl:show="new">72005009</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_ed6209bc-8fdc-4f8c-a273-5b981c64039c">Skin of areola</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_524e9e7d-cc63-48d6-a9b4-7e4edca9d371">
                                <link xl:href="http://snomed.info/id/72005009" xl:show="new">T-02432</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b05c551c-e0c5-45ef-89ff-0ce10b2851ed">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222151" xl:show="new">C0222151</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b64465b1-5871-4087-9411-5fd756c64c6a">
                                <link xl:href="http://purl.org/sig/ont/fma/fma50050" xl:show="new">50050</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ad2e5b61-dbd5-4297-b4d4-5955de8f2e35">
                                <link xl:href="http://id.who.int/icd/entity/1832289433" xl:show="new">XA2JK3</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_936d198b-ae20-418f-9c24-3500d4866bd5">207</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_696b15e2-d665-4f41-915a-e048b75cbbc7"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_cfcfcd6d-7af1-41b5-8414-686a133b19ba">206</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8b2e5ee2-b8b1-41f2-bcbe-8b9aa4935a9c">207</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6cb6963d-6ffa-4307-9bf7-f6915efbe3f0"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7d6300a1-efbc-4b3c-85a9-0ca6e68dfacb">206</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6c8883ee-3725-4b2c-8469-3d2bf169e19e">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_63e3dcdd-48b1-432b-9286-abc2c9704ad0">
                                <link xl:href="http://snomed.info/id/699893008" xl:show="new">699893008</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_270b496d-2602-414b-a51f-0da862fd014b">Skin of back of upper thoracic region</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0a667eb7-e008-45b8-b1d5-00046795d1ab">
                                <link xl:href="http://snomed.info/id/699893008" xl:show="new">R-FB4DA</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_061e04b4-0eb3-4b5a-ba71-9ee3a75eb4cf">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C3697168" xl:show="new">C3697168</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_6aa8e063-ba12-4ef0-881b-7d5847202156">
                                <link xl:href="http://purl.org/sig/ont/fma/fma23024" xl:show="new">23024</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f9fe2e1f-d2b8-4d16-a183-6f410b983ae9">
                                <link xl:href="http://id.who.int/icd/entity/730488167" xl:show="new">XA10L7</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_de09d563-e9d2-4493-8037-b7390e8feb94">225</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_9d4cbe18-2e2c-4306-9e08-a1407b4fb125"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_82e60c9d-6e9d-4351-93c8-1553f84b44d6">224</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_78ec6dd8-202e-4024-89fa-701581297590">225</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7ffcd06a-1f94-4184-a405-605cb7cae818"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ffd93c87-b2a7-49b2-b71d-8170ea5f959f">224</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">SCT</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://snomed.info/id/82038008" xl:show="new"><emphasis role="bold"><emphasis role="underline">82038008</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para><emphasis role="bold"><emphasis role="underline">Skin of breast</emphasis></emphasis></para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://snomed.info/id/82038008" xl:show="new"><emphasis role="bold"><emphasis role="underline">T-02430</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para>
                                    <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0149538" xl:show="new"><emphasis role="bold"><emphasis role="underline">C0149538</emphasis></emphasis></link>
                                </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4fdaa88e-0d21-4ad0-8845-4c0a3bc933fe">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8a777f5d-9139-46ad-ad79-0f9fa4f47bf7">
                                <link xl:href="http://snomed.info/id/22180002" xl:show="new">22180002</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_49414884-4c67-4af4-aeb6-31fdd5ad807a">Skin of buttock</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_088ba505-c764-4f1c-b6e0-ba19f764f457">
                                <link xl:href="http://snomed.info/id/22180002" xl:show="new">T-02471</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_942f10f5-509d-4d62-ba9c-ebde3d50f43e">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222165" xl:show="new">C0222165</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_66f34712-ea8c-497c-828e-b4a7161f504f">
                                <link xl:href="http://purl.org/sig/ont/fma/fma45285" xl:show="new">45285</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7a0c40da-977e-494b-83c9-352d4fde3cf7">
                                <link xl:href="http://id.who.int/icd/entity/1894266247" xl:show="new">XA3VA7</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d16d8d74-228a-4044-af49-b32a104971f2">231</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_7b369d9f-53c1-4e93-b14d-aa0f477b5578"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_f0995928-30a3-4734-9206-61bbf7a0d4fc">230</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0792cfda-4b81-401e-9e6c-26695d24d25b">231</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_d522e522-1451-4691-b95b-d468b70881f0">527a</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_94b61b3f-f132-46e0-a968-0716916d0fcf">230</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0bd97ef9-0a80-42de-9d67-b2c873c4f375">SCT</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_a464bbc5-87ca-41ab-b913-c912fa7b6f21">
                                <link xl:href="http://snomed.info/id/54468004" xl:show="new">54468004</link>
                            </para>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para xml:id="para_446ba674-3c7f-4620-a81f-2015f34ceb8a">Skin of nipple</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_0da3ab6d-04e2-4117-855d-2749157064e8">
                                <link xl:href="http://snomed.info/id/54468004" xl:show="new">T-02431</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_b3d32206-3853-4606-8c5f-178f894276b1">
                                <link xl:href="http://uts.nlm.nih.gov/uts/umls/concept/C0222150" xl:show="new">C0222150</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3fee896d-d14e-478c-b2ca-ae7c62dc2555">
                                <link xl:href="http://purl.org/sig/ont/fma/fma12828" xl:show="new">12828</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_3d6a5efd-2d4e-4519-afb7-43faa11abfd7">
                                <link xl:href="http://id.who.int/icd/entity/2048843865" xl:show="new">XA5MC5</link>
                            </para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_8fab5be9-03de-41db-986b-205812786902">205</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4256ee4c-71d9-48b6-afa3-0de456273029"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5b1fc2b4-e8ef-4a74-8329-982655b57f7f">204</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_4e515cff-a23e-4f61-b547-5d60a83480f1">205</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_5e334b70-3d2f-4413-96ae-222f9ef13fd2"/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para xml:id="para_ddc7f08b-6239-4d27-9252-73d6e7381b88">204</para>
                        </td>
                    </tr>
                    <tr valign="top">
                        <td align="center" colspan="1" rowspan="1">
                            <para>...</para>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="left" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                        <td align="center" colspan="1" rowspan="1">
                            <para/>
                        </td>
                    </tr>
                </tbody>
            </table>
        </section>
    </section>
  </chapter>
</book>