<book xmlns="http://docbook.org/ns/docbook" xmlns:xl="http://www.w3.org/1999/xlink" version="5.0">
    <title>CP-2213</title>
    <subtitle>Species Attributes conditions should be non-human not animal</subtitle>
    <chapter>
        <title></title>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Status</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Letter Ballot</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Date of Last Update</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2022/10/03</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Person Assigned</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>David Clunie <link
                    xl:href="mailto:dclunie@dclunie.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submitter Name</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>Carlos Anderson <link
                    xl:href="mailto:carlosjanderson@gmail.com"/></para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Submission Date</para></td>
                <td rowspan="1" colspan="1" valign="top"><para>2022/02/03</para></td>
            </tr>
        </informaltable>
        <informaltable rules="all" frame="box">
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Correction Number CP-2213</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Log Summary: Species Attributes conditions should be non-human not animal</para></td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">
                    <para>Name of Standard</para>
                    <para>PS3.3</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top"><para>Rationale for Correction:</para>
                    <para>The description for the "Patient Species Description Attribute" says "Required if the Patient is an animal..." but I think it meant to say "Required if the Patient is non-human..." since humans are animals.
                        Similar issue for the description for the "Patient Species Code Sequence Attribute".</para>
                    <para>Distinguish between requirements for any organism (species), as opposed to non-human animals (responsible people).</para>
                </td>
            </tr>
            <tr>
                <td rowspan="1" colspan="1" valign="top">Correction Wording:</td>
            </tr>
        </informaltable>
    </chapter>
    <chapter>
        <title/>
        
        <informaltable rules="all" frame="box">
            <tr>
                <td>
                    <para><emphasis role="italic">Amend PS3.3 as follows:</emphasis></para>
                </td>
            </tr>
        </informaltable>
        
        
        <section label="C.7.1.1" status="4" xml:id="sect_C.7.1.1">
                    <title>Patient Module</title>
                    <table frame="box" label="C.7-1" rules="all" xml:id="table_C.7-1">
                        <caption>Patient Module Attributes</caption>
                        <thead>
                            <tr valign="top">
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b3c32db2-8602-4023-89bb-3856b3c51c8e">Attribute Name</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2f7d731b-1fef-4474-81fb-bd2eb47efb40">Tag</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8d036e51-8ab1-43d3-8460-77d97c7a5ff9">Type</para>
                                </th>
                                <th align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_53c874ba-0179-437b-86d0-406e872b2065">Attribute Description</para>
                                </th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_76c086db-a2d6-4fc4-a972-aa17309cb654">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ecc4b464-145e-41d1-a0f7-1da3f3b132f4"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_1ce2285f-6014-4620-a482-683a4f86bc21"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f4631c33-1fec-4136-841a-72846b2899fa"/>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a3a925ed-fd7e-4205-b03b-eb9a144546d2">Patient Species Description</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_aab7ecd8-b729-4c4f-b8d3-1c617596e00c">(0010,2201)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3b26586e-e1f0-406b-a40e-d702bdf83333">1C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_357ac623-a8b0-444d-a5cc-d1e764bea6e9">The taxonomic rank value (e.g., genus, subgenus, species or subspecies) of the Patient. See <xref linkend="sect_C.7.1.1.1.3" xrefstyle="select: label"/>.</para>
                                    <para xml:id="para_b6616cf4-dd1c-4428-8996-f7ad87ff58a2">Required if the Patient is an animal and if Patient Species Code Sequence (0010,2202) is not present. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2859ee8d-20a9-4696-a2d2-5c83c3b72730">Patient Species Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_47525aba-146d-4ce4-8c05-5c966f6060a7">(0010,2202)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f1e91d2a-15ef-46c8-aa73-d60a312bb89a">1C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_78622739-5d75-4d88-84b3-9e8c21d7c7ea">The taxonomic rank value (e.g., genus, subgenus, species or subspecies) of the Patient. See <xref linkend="sect_C.7.1.1.1.3" xrefstyle="select: label"/>.</para>
                                    <para xml:id="para_3a0c09e4-57b2-4a84-9ed5-993aff8a7d1c">Only a single Item shall be included in this Sequence.</para>
                                    <para xml:id="para_3c6a4032-5bae-44a0-9b70-2b5939b11470">Required if the Patient is <emphasis role="bold"><emphasis role="strikethrough">an animal</emphasis><emphasis role="underline">an organism and not human, </emphasis></emphasis> and if Patient Species Description (0010,2201) is not present. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_25718553-4595-4d95-936c-b6628ff15f65">
                                        <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1c2a92c9-4593-4b10-8160-f59b29b601cf">
                                        <emphasis role="italic">D<olink targetdoc="PS3.16" targetptr="sect_CID_7454" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_af583421-957e-4ca5-b29d-77960e5c99ab">Patient Breed Description</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_75f78a9e-df95-4c22-86ac-3edff80d4d51">(0010,2292)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_22efdb80-10ba-41f8-9139-919acc9ea9f7">2C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7f0ac637-10dc-49c2-8be2-38db3dcf0edb">The breed of the Patient. See <xref linkend="sect_C.7.1.1.1.1" xrefstyle="select: label"/>.</para>
                                    <para xml:id="para_e62562b8-19f8-4928-9e5c-bc438bb30baf">Required if the Patient is <emphasis role="bold"><emphasis role="strikethrough">an animal</emphasis><emphasis role="underline">an organism and not human, </emphasis></emphasis> and if Patient Breed Code Sequence (0010,2293) is empty. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e4eae53a-9ad1-4fba-aaa3-684f30804492">Patient Breed Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_5885935b-132b-4239-be30-93dbccd3b57d">(0010,2293)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_23084f42-4ee8-4952-8dbb-45e7ef97bc45">2C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_1c11ed39-a047-49d6-8e95-13c14792713d">The breed of the Patient. See <xref linkend="sect_C.7.1.1.1.1" xrefstyle="select: label"/>.</para>
                                    <para xml:id="para_9acd9229-1c86-474c-b36a-adf4cbc04882">Zero or more Items shall be included in this Sequence.</para>
                                    <para xml:id="para_5c80a1b1-13b1-4018-b4fa-1ccd0d733465">Required if the Patient is <emphasis role="bold"><emphasis role="strikethrough">an animal</emphasis><emphasis role="underline">an organism and not human</emphasis></emphasis>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_ef88f1eb-9057-46af-a2d8-d55d60246827">
                                        <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_035a9a71-caa8-4b42-989b-69da6f1a56ed">
                                        <emphasis role="italic">D<olink targetdoc="PS3.16" targetptr="sect_CID_7480" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_beb77b2a-5cd3-4386-9a45-d27a28b3b8fc">Breed Registration Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_d27550da-4ba3-4f81-a79e-774595b6f4a4">(0010,2294)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_46de22ef-f77b-42e3-b570-5a8596ab15d2">2C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_6b5a3e9a-1a9f-44fe-9162-9178d2d85c53">Information identifying an animal within a breed registry.</para>
                                    <para xml:id="para_9c1ea333-7195-47ea-84fc-150e73463ac3">Zero or more Items shall be included in this Sequence.</para>
                                    <para xml:id="para_3b78ecb3-9a2a-4c21-9a5b-2a76da289fa8">Required if the Patient is <emphasis role="bold"><emphasis role="strikethrough">an animal</emphasis><emphasis role="underline">an organism and not human</emphasis></emphasis>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_a5537f46-cfa9-4a8f-8b5a-c11a2cbfb870">&gt;Breed Registration Number</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_8c767af6-0fe2-4240-ae73-bb8464a676b5">(0010,2295)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e8f57aeb-7ec7-408e-9120-7106a89f71e5">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4922a4ea-a6a4-4498-b7d8-419161bfa391">Identification number of an animal within the registry.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_7460508d-429e-4b0f-b65b-45a7f10b73e4">&gt;Breed Registry Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_4d8be9fe-7bda-4d60-8995-086724900795">(0010,2296)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a9ff7675-2757-4643-9415-c6e5bf1c8515">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8d67b5ad-f789-4e7e-9270-01ec96a7d9e2">Identification of the organization with which an animal is registered.</para>
                                    <para xml:id="para_78d96fa3-8569-4fd1-8e90-3091baa350d3">Only a single Item shall be included in this Sequence.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_39b66a48-9cc7-443e-b91d-d43810760e99">
                                        <emphasis role="italic">&gt;&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d348dcae-6ab6-4edf-aa34-013cc1eb897a">
                                        <emphasis role="italic">D<olink targetdoc="PS3.16" targetptr="sect_CID_7481" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f76feadf-d3d8-4790-b549-d1106c318766">Strain Description</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_19d46ff5-57c2-4f1b-be04-c06ace85677e">(0010,0212)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3568d9af-f5ef-4875-a5cc-26dd3df4f191">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_8421fbca-502e-4909-b03f-5789cda64935">The strain of the Patient. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_26a2a91c-73e8-427b-a75a-e750284604fe">Strain Nomenclature</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e03d56f2-9745-4e63-b31f-d63cf5e2185b">(0010,0213)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_06430dbe-fc00-40ad-808e-85771e82bd04">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_ea1c4023-3354-45aa-b770-e942796f32f3">The nomenclature used for Strain Description (0010,0212). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3b80e074-7bb6-4f12-93d0-4db8581dfa15">Strain Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_38a4541c-3bc1-4563-8dab-1d6157c4ec93">(0010,0219)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_ddaa7b36-a3d8-475d-8cad-12b7f4c1d982">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_23ef1638-a6f9-45d2-99da-4446fcd29527">A coded identification of the strain of the Patient. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                    <para xml:id="para_6189a2a0-f478-4e2b-be5a-bf7db631610e">One or more Items are permitted in this Sequence. If more than one Item is present, each Item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_8d9dff82-a4f6-4e1d-a588-f71b758874e1">
                                        <emphasis role="italic">&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f617bbdf-eca3-4513-a56f-0d14c85a1f3a">
                                        <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0c36fad4-3086-4294-a219-b747e9fcc07f">Strain Additional Information</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a7f4711e-2f08-4c88-98c3-8c61910ed838">(0010,0218)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9a53049c-a837-4885-867d-f47496336f4e">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_21b69572-0ae1-4997-87a8-9adab52f14ad">Additional information about the strain of the Patient that is not encoded in the formal nomenclature used in Strain Description (0010,0212). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4382f21f-7a26-4d99-917d-2af4196a56eb">Strain Stock Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9cd13f11-6131-481f-9408-4329c4d9f781">(0010,0216)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_42ac24e9-2d92-413a-b9e5-4a02cc7b916b">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_211fe8ce-361a-4d1d-8fa7-bb170c1beb35">Information identifying an animal within a strain stock.</para>
                                    <para xml:id="para_042b69c4-fd32-4666-b6c7-d9f608a07305">Only a single Item is permitted in this Sequence.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_d1d1ed10-da17-4a8b-afa4-7a030dffe912">&gt;Strain Stock Number</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_17d6793a-2d21-4159-bb9b-f8d81ad71429">(0010,0214)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_3f0a8d5a-d80c-4ede-8b91-c1ffc584f5eb">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_158a4687-a206-4636-b2c2-ca9ef049bd58">The stock number of the strain of the Patient issued by the organization identified by Strain Source (0010,0217). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_11252d2d-143b-42fc-b152-57902f2c2cde">&gt;Strain Source</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_659e4062-37d9-4f19-a2b1-1e07651822c9">(0010,0217)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e0170493-ae24-4349-931a-5b196e9ddf43">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e602d4a9-a774-4623-8492-6bd2c1f27825">Identification of the organization that is the source of the animal, issued by the registry identified by Strain Source Registry Code Sequence (0010,0215). See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_005c11a2-1f75-49d4-9e14-93196424aefb">&gt;Strain Source Registry Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_89b10df7-31b5-4b2f-a95b-78f8bc2f0bec">(0010,0215)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2b5e5165-9797-4db9-b5a5-e8fb514f3688">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_01c9cf7a-1c6c-44f3-a961-398645ba3789">Identification of the organization that is the registry of sources of animals. See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                    <para xml:id="para_9eed1e69-84b2-4031-aab0-a63568f737bf">Only a single Item is permitted in this Sequence.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_ab494445-9863-4318-bed3-b397066f2cbc">
                                        <emphasis role="italic">&gt;&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_78557ec3-fcee-45ae-b867-09edfd333603">
                                        <emphasis role="italic">D<olink targetdoc="PS3.16" targetptr="sect_CID_7490" xrefstyle="select: labelnumber quotedtitle"/>.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_f7ebff3a-ec62-44c7-ad52-2c840276050b">Genetic Modifications Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_e335a272-d305-4a5d-aa03-5edf4ae15674">(0010,0221)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_2975292a-0ef0-4222-95a9-4d54dd5ed028">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_3f50cb7a-cf57-4df5-b36e-218acf7a2121">The genetic modifications of the Patient.</para>
                                    <para xml:id="para_4c4d7fba-6d24-4b90-920c-4e3db40d385d">One or more Items are permitted in this Sequence.</para>
                                    <para xml:id="para_050b28f1-3ede-4b5d-aa80-6130bf14ae68">See <xref linkend="sect_C.7.1.1.1.4" xrefstyle="select: label"/>.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_beb3af15-78d8-4a7f-8e1a-d63bb7065d7f">&gt;Genetic Modifications Description</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_74ddaa15-7774-49d1-bd95-e7bf15ca4e53">(0010,0222)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_7eb7100f-5fce-4807-8cab-267d66931a5c">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_dfac9ff6-3811-42ff-b26f-62db1987fec9">The genetic modifications of the Patient described using a specific nomenclature.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_2dc1783b-27c3-4fe6-b148-acc86307d947">&gt;Genetic Modifications Nomenclature</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_968b096a-3bd2-4955-a6cb-a7602ba14e04">(0010,0223)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_9712b77c-3af5-44d3-883c-f04fa3d706c5">1</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_0adb0f30-a48d-4a28-b94c-dd74cf00372e">The nomenclature used for Genetic Modifications Description (0010,0222).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c710f0a9-bbfe-46fa-94a2-957e059dbf71">&gt;Genetic Modifications Code Sequence</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_542befb4-1bf6-4d62-a848-a7eb0f5ec05f">(0010,0229)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_a4cffc26-e29c-4601-90c0-c1260565f3be">3</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c71e61d9-6ab0-4250-b3e8-09af0eb636f6">A coded identification of the genetic modifications of the Patient.</para>
                                    <para xml:id="para_3223a521-d824-4ec2-ac1d-e7d67faa6df4">One or more Items are permitted in this Sequence. If more than one Item is present, each Item represents the same information but encoded using a different coding scheme (rather than post-coordinated modifiers).</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="3" rowspan="1">
                                    <para xml:id="para_ac0d0742-f69e-4d04-b2d4-ecd8f2c90095">
                                        <emphasis role="italic">&gt;&gt;Include <xref linkend="table_8.8-1" xrefstyle="select: label quotedtitle"/>
                                        </emphasis>
                                    </para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c0e14ab1-cd56-416c-9e0c-120430f972db">
                                        <emphasis role="italic">No Baseline CID is defined.</emphasis>
                                    </para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_c15a4781-8cb2-422a-9c64-8b4a097f37bb">Responsible Person</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f6b3ecb9-c04b-49be-8467-50ed23f70165">(0010,2297)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_f290879b-7e71-4442-9fd0-4f867dcc1dc1">2C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_580b04f7-c155-47ec-b706-adce0b6e62df">Name of person with medical or welfare decision making authority for the Patient.</para>
                                    <para xml:id="para_e5da03bf-9169-42e0-bce6-1254942d833a">Required if the Patient is an animal<emphasis role="bold"><emphasis role="underline"> and not human</emphasis></emphasis>. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_90be565d-9cad-4150-978f-05c2b3631c21">Responsible Person Role</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_230d7c9a-177a-4c82-b674-c3026f957f21">(0010,2298)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_529e26aa-2aaf-49ad-a8b8-d67978c50fe9">1C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_04390648-2d09-42e2-8914-c73cdc9b3f13">Relationship of Responsible Person to the Patient.</para>
                                    <para xml:id="para_7c01e0ae-babd-4434-8861-5a36d2aa401e">See <xref linkend="sect_C.7.1.1.1.2" xrefstyle="select: label"/> for Defined Terms.</para>
                                    <para xml:id="para_5d90c80e-b629-45cc-86ea-faa123eaa92c">Required if Responsible Person is present and has a value.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_4e11ae6b-f9c5-47cd-a5b1-8b92143bab76">Responsible Organization</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_88db3b9b-a9a2-4a37-b0ad-0bef80db7afe">(0010,2299)</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_10fcc05e-8b66-4e63-898b-c5b6cd6e33ee">2C</para>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_cbb86474-5287-4081-8e2b-c2c4935e4be2">Name of organization with medical or welfare decision making authority for the Patient.</para>
                                    <para xml:id="para_cfec4395-e64e-490e-834d-25c529db8c86">Required if Patient is an animal<emphasis role="bold"><emphasis role="underline"> and not human</emphasis></emphasis>. May be present otherwise.</para>
                                </td>
                            </tr>
                            <tr valign="top">
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_60d2a75a-851b-44b8-927f-eacfa977eab2">...</para>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_371fad55-c4ed-49d9-99c5-151af19cc8d2"/>
                                </td>
                                <td align="center" colspan="1" rowspan="1">
                                    <para xml:id="para_b9919c55-fe1b-4235-af8f-d0e23bcc7b96"/>
                                </td>
                                <td align="left" colspan="1" rowspan="1">
                                    <para xml:id="para_e0dbd8c7-4850-4a0a-bb11-101618520413"/>
                                </td>
                            </tr>
                        </tbody>
                    </table>
                    <section label="C.7.1.1.1" status="5" xml:id="sect_C.7.1.1.1">
                        <title>Patient Module Attributes</title>
                        <section label="C.7.1.1.1.1" status="6" xml:id="sect_C.7.1.1.1.1">
                            <title>Patient Breed Description and Code Sequence</title>
                            <para xml:id="para_8b957edc-00bd-4a31-9bc6-babeabff822e">The breed of an animal, if known, shall be encoded in either Patient Breed Description (0010,2292) or Patient Breed Code Sequence (0010,2293) or both.</para>
                            <para xml:id="para_6099f8ea-6274-41c7-a18c-cca77c8f14fd">In the case of a mixed breed, it shall be either:</para>
                            <orderedlist>
                                <listitem>
                                    <para xml:id="para_5eac5d7f-b079-469e-a07c-7b951c215ec6">described in plain text in Patient Breed Description (0010,2292), e.g., "Border Collie American Bulldog mix", or just "Mixed", or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_b6f908b0-8c52-4ce7-bbc8-1b941fbce9e9">coded as multiple specific breeds by composing the mix as multiple Items of Patient Breed Code Sequence (0010,2293), e.g., <link xl:href="http://snomed.info/id/132561000" xl:show="new">(132561000, SCT, "Border Collie dog breed")</link> followed by <link xl:href="http://snomed.info/id/132534000" xl:show="new">(132534000, SCT, "American Bulldog breed")</link>, or</para>
                                </listitem>
                                <listitem>
                                    <para xml:id="para_e47a0fc4-a61d-43f1-a6e6-8d58fdbff60c">encoded non-specifically with a code that means "mixed breed" of the appropriate species, as defined in <olink targetdoc="PS3.16" targetptr="sect_CID_7486" xrefstyle="select: labelnumber quotedtitle"/>, which is included in <olink targetdoc="PS3.16" targetptr="sect_CID_7480" xrefstyle="select: labelnumber quotedtitle"/>, e.g., <link xl:href="http://snomed.info/id/132619000" xl:show="new">(132619000, SCT, "Mixed breed dog")</link>.</para>
                                </listitem>
                            </orderedlist>
                            <note>
                                <para xml:id="para_c8a8ba43-3d5b-4e24-87b1-6a22edd0545a">The absence of a value for both Patient Breed Description (0010,2292) and Patient Breed Code Sequence (0010,2293) implies that the breed is unknown, not that it is mixed.</para>
                            </note>
                        </section>
                        <section label="C.7.1.1.1.2" status="6" xml:id="sect_C.7.1.1.1.2">
                            <title>Responsible Person Role</title>
                            <variablelist spacing="compact">
                                <title>Defined Terms:</title>
                                <varlistentry>
                                    <term>OWNER</term>
                                    <listitem>
                                        <para xml:id="para_ba7ced2b-5c7a-4ec6-a006-50d3f7207760"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>PARENT</term>
                                    <listitem>
                                        <para xml:id="para_92ac7432-6f1a-49e1-a20a-db2b54bdc9f4"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>CHILD</term>
                                    <listitem>
                                        <para xml:id="para_38b12f28-067b-4587-a91c-8083b35be3a0"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>SPOUSE</term>
                                    <listitem>
                                        <para xml:id="para_87be8b42-f8cc-49f1-a31c-c1f4554e2627"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>SIBLING</term>
                                    <listitem>
                                        <para xml:id="para_a4dbf358-9602-4a53-b4dc-1bb0562af432"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>RELATIVE</term>
                                    <listitem>
                                        <para xml:id="para_8c9b7c44-b817-4200-9a40-d3a91d7285f5"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>GUARDIAN</term>
                                    <listitem>
                                        <para xml:id="para_7b8164e8-eb97-4410-8245-55373bf0661d"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>CUSTODIAN</term>
                                    <listitem>
                                        <para xml:id="para_8a92efa3-4678-41e0-a90b-6235489aa314"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>AGENT</term>
                                    <listitem>
                                        <para xml:id="para_85e34e04-23cc-4a96-9470-18634a6ef9d8"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>INVESTIGATOR</term>
                                    <listitem>
                                        <para xml:id="para_b4973b61-cd28-4575-85d0-f03a3be15476"/>
                                    </listitem>
                                </varlistentry>
                                <varlistentry>
                                    <term>VETERINARIAN</term>
                                    <listitem>
                                        <para xml:id="para_2c28f0b9-56eb-4435-beae-9f7c99ecf9f9"/>
                                    </listitem>
                                </varlistentry>
                            </variablelist>
                        </section>
                        <section label="C.7.1.1.1.3" status="6" xml:id="sect_C.7.1.1.1.3">
                            <title>Patient Species (Taxonomic Rank Value)</title>
                            <para xml:id="para_7f54b0be-d5a6-4033-8c84-1507d7596b4f">If the species is not known then the Patient Species Description (0010,2201) or Patient Species Code Sequence (0010,2202) may describe a more general taxonomic rank value, such as a genus or subgenus, family or subfamily.</para>
                            <note>
                                <para xml:id="para_1500500b-963b-490c-b9ef-5b8a87fcbed1">E.g., "Mus" rather than "Mus musculus".</para>
                            </note>
                            <para xml:id="para_8282e944-2c1a-4bba-8326-64d61adc2efc">If the subspecies is known then the Patient Species Description (0010,2201) or Patient Species Code Sequence (0010,2202) may describe the subspecies.</para>
                            <note>
                                <para xml:id="para_5f57d249-89bc-4924-9bd8-621a7e7b24fa">E.g., "Canis lupus familiaris" rather than "Canis lupus".</para>
                            </note>
                        </section>
                        <section label="C.7.1.1.1.4" status="6" xml:id="sect_C.7.1.1.1.4">
                            <title>Patient Strain and Genetic Modifications</title>
                            <para xml:id="para_85d70a75-8634-4a5c-bd35-edf49db2ec03">The strain of an animal (group of animals that is genetically uniform), if known, may be encoded in Strain Description (0010,0212). The nomenclature used may be encoded in Strain Nomenclature (0010,0213). A precoordinated code identifying the strain may be encoded in Strain Code Sequence (0010,0219).</para>
                            <variablelist>
                                <title>Defined Terms for Strain Nomenclature (0010,0213) and Genetic Modifications Nomenclature (0010,0223):</title>
                                <varlistentry>
                                    <term>MGI_2013</term>
                                    <listitem>
                                        <para xml:id="para_c063adab-6f7b-4e33-bf93-8cb2e6abe8de">International Committee on Standardized Genetic Nomenclature for Mice, Rat Genome and Nomenclature Committee. MGI-Guidelines for Nomenclature of Mouse and Rat Strains. 2013/10. Available from: <link xl:href="http://www.informatics.jax.org/mgihome/nomen/strains.shtml"/>
                                        </para>
                                    </listitem>
                                </varlistentry>
                            </variablelist>
                            <note>
                                <itemizedlist>
                                    <listitem>
                                        <para xml:id="para_9e9daf70-3220-4060-b141-f3ddc06fb8a4">A pair of text and nomenclature Attributes are used, since standard nomenclatures typically define values that are constructed from multiple components, and do not distinguish between value and meaning. These are distinct from the precoordinated codes used in Strain Code Sequence (0010,0219).</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_24331c93-21a6-42d3-82ae-fcd877e900bd">Some strain and genetic modification nomenclatures make use of superscripts. To encode these superscripts consistently in an unformatted string, the convention of enclosing the superscript text in "&lt;" and "&gt;" pairs may be used. E.g., "D2.B6-Ahr<superscript>b-1</superscript>/J" would be encoded as "D2.B6-Ahr&lt;b-1&gt;/J".</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_cb2e3eea-c8eb-40fc-b5f8-ba73a9b777a1">Relevant information that is not encoded in the formal description of the strain (i.e., not defined in the nomenclature used), such as the number of transgenes, may be encoded as plain text in Strain Additional Information (0010,0218).</para>
                                    </listitem>
                                </itemizedlist>
                            </note>
                            <para xml:id="para_d6ad9008-83de-4efa-9b51-f95f88ea0f60">The strain of an animal may be more specifically identified by the Attributes within Strain Stock Sequence (0010,0216).</para>
                            <note>
                                <itemizedlist>
                                    <listitem>
                                        <para xml:id="para_f409affe-78e3-4c74-8070-a846a734c186">The MGI-Guidelines for Nomenclature of Mouse and Rat Strains recommends the use of the laboratory codes assigned by the Institute of Laboratory Animal Research (ILAR). See the International Laboratory Code Registry (ILCR) <link xl:href="http://dels.nas.edu/global/ilar/lab-codes"/>.</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_6261cd3c-beff-4de1-b4b4-f9d1666c4b5f">Because allele names are closely tied to gene names/symbols it is necessary to have a unique and permanent code for any allele that is part of a genotype of interest. For mice, MGI is the authoritative source of the nomenclature for genes and alleles and maintains unique, permanent codes for these entities. The MGI provides a report of all precoordinated MGI codes that are assigned to specific strains at <link xl:href="http://www.informatics.jax.org/downloads/reports/MGI_Strain.rpt"/>. These may be used in Strain Code Sequence (0010,0219) and Genetic Modifications Code Sequence (0010,0229) with a coding scheme of "MGI".</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_30cc1156-109a-410f-a675-0bcb907028e3">Another source of pre-coordinated codes for strains is the NCI Thesaurus, which includes a snapshot of strains from the International Mouse Strain Resource (IMSR), as children of (C14421, NCIt, "Inbred Mouse Strains"). See <link xl:href="http://ncit.nci.nih.gov/ncitbrowser/pages/concept_details.jsf?dictionary=NCI_Thesaurus&amp;code=C14421"/>.</para>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_988a9746-b8f8-499e-bdd5-d49c342bd3fa">For example, a C57BL/6J mouse strain from The Jackson Laboratory might be identified as:</para>
                                        <itemizedlist mark="none">
                                            <listitem>
                                                <para xml:id="para_2f7d373c-a827-464b-b902-1a2a6790981e">Strain Description (0010,0212) = "C57BL/6J"</para>
                                            </listitem>
                                            <listitem>
                                                <para xml:id="para_c6bca708-6096-4264-92fa-45de6546a7d4">Strain Nomenclature (0010,0213) = "MGI_2013"</para>
                                            </listitem>
                                            <listitem>
                                                <para xml:id="para_05207449-5da6-4722-9710-c4db80c0f7c5">Strain Code Sequence (0010,0219)</para>
                                                <itemizedlist mark="none">
                                                    <listitem>
                                                        <para xml:id="para_7b4a0cea-2291-4f1e-bd96-1ebba9c43e80">&gt;Code Value (0008,0100) = "3028467"</para>
                                                    </listitem>
                                                    <listitem>
                                                        <para xml:id="para_4494416e-08de-4992-a77d-2c6187563f76">&gt;Coding Scheme Designator (0008,0102) = "MGI"</para>
                                                    </listitem>
                                                    <listitem>
                                                        <para xml:id="para_3cce13d5-d827-41bc-ad81-c561d8379da2">&gt;Code Meaning (0008,0104) = "C57BL/6J"</para>
                                                    </listitem>
                                                </itemizedlist>
                                            </listitem>
                                            <listitem>
                                                <para xml:id="para_b5577544-e85a-412f-9ec3-c96b04671b58">Strain Stock Sequence (0010,0216)</para>
                                                <itemizedlist mark="none">
                                                    <listitem>
                                                        <para xml:id="para_c36db518-148b-4f27-bc19-bd227f9caf06">&gt;Strain Stock Number (0010,0214) = "000664"</para>
                                                    </listitem>
                                                    <listitem>
                                                        <para xml:id="para_047ee409-a924-4772-ab89-45e244cb6966">&gt;Strain Source (0010,0217) = "Jrep"</para>
                                                    </listitem>
                                                    <listitem>
                                                        <para xml:id="para_8f9aa498-68c2-484d-a200-9c3ac35ffb63">&gt;Strain Source Registry Code Sequence (0010,0215)</para>
                                                        <itemizedlist mark="none">
                                                            <listitem>
                                                                <para xml:id="para_902f5f35-bf51-49c6-a3e5-ae3d68bc8e01">&gt;&gt;Code Value (0008,0100) = <olink targetdoc="PS3.16" targetptr="DCM_126850" xrefstyle="select: nopage">126850</olink>
                                                                </para>
                                                            </listitem>
                                                            <listitem>
                                                                <para xml:id="para_af1f9db1-b0df-4956-937a-6015b83dcf86">&gt;&gt;Coding Scheme Designator (0008,0102) = "DCM"</para>
                                                            </listitem>
                                                            <listitem>
                                                                <para xml:id="para_694605b2-836a-4a32-b08b-a58b0b58ba69">&gt;&gt;Code Meaning (0008,0104) = "ILCR"</para>
                                                            </listitem>
                                                        </itemizedlist>
                                                    </listitem>
                                                </itemizedlist>
                                            </listitem>
                                        </itemizedlist>
                                    </listitem>
                                    <listitem>
                                        <para xml:id="para_85370d9a-0604-41e5-a1d8-aab1e8c2cfe9">For example, a FVB/N mouse with a Tg(MMTV-Erbb2*)NDL2-5Mul transgene might be identified as:</para>
                                        <itemizedlist mark="none">
                                            <listitem>
                                                <para xml:id="para_d26efb2a-99de-4464-a3f6-bb33d42a809f">Strain Description (0010,0212) = "FVB/N-Tg(MMTV-Erbb2*)NDL2-5Mul"</para>
                                            </listitem>
                                            <listitem>
                                                <para xml:id="para_e3260cfb-0b40-4943-a304-695ee42fa88e">Strain Nomenclature (0010,0213) = "MGI_2013"</para>
                                            </listitem>
                                            <listitem>
                                                <para xml:id="para_eafc1487-4b33-477d-865d-7304430fc894">Genetic Modifications Sequence (0010,0221)</para>
                                                <itemizedlist mark="none">
                                                    <listitem>
                                                        <para xml:id="para_a7fe9cc5-57a5-4572-92dd-da7c403f81ce">&gt;Genetic Modifications Description (0010,0222) = "Tg(MMTV-Erbb2*)NDL2-5Mul"</para>
                                                    </listitem>
                                                    <listitem>
                                                        <para xml:id="para_42bd98fc-2c17-44fa-8421-d810c3baddbf">&gt;Genetic Modifications Nomenclature (0010,0223) = "MGI_2013"</para>
                                                    </listitem>
                                                    <listitem>
                                                        <para xml:id="para_68dd459b-7b27-4231-a9a6-5118f1d86d0d">&gt;Genetic Modifications Code Sequence (0010,0229)</para>
                                                        <itemizedlist mark="none">
                                                            <listitem>
                                                                <para xml:id="para_8a7d5c1c-81fc-4f85-a599-33010fbb905b">&gt;&gt;Code Value (0008,0100) = "3793949"</para>
                                                            </listitem>
                                                            <listitem>
                                                                <para xml:id="para_ea138826-e5f1-49af-bd26-3d044aa52993">&gt;&gt;Coding Scheme Designator (0008,0102) = "MGI"</para>
                                                            </listitem>
                                                            <listitem>
                                                                <para xml:id="para_60a257bf-830e-4f82-b78f-3128a44ff0f1">&gt;&gt;Code Meaning (0008,0104) = "Tg(MMTV-Erbb2*)NDL2-5Mul"</para>
                                                            </listitem>
                                                        </itemizedlist>
                                                    </listitem>
                                                </itemizedlist>
                                            </listitem>
                                        </itemizedlist>
                                        <para xml:id="para_06c0e903-e59a-4aa3-bbf4-8191f849c9c3">In this example, a precoordinated code for the genetic modification is defined in MGI, but not for the mouse strain.</para>
                                    </listitem>
                                </itemizedlist>
                            </note>
                        </section>
                    </section>
                </section>
        
        
        
        
        
        
        
        
        
        
        
        
        
        
        
                        
                

        
        
    
        

    </chapter>
</book>
